Supply Of 1) ENDOSCOPIC SUBMUCOSAL DISSECTION (ESD) CLUTCH CUTTER & 2) ENDOSCOPIC SUBMUCOSAL DISSECTION (ESD) TRACMOTION DEVICE
Tender Overview
Project Description
Supply Of 1) endoscopic submucosal dissection (esd) clutch cutter & 2) endoscopic submucosal dissection (esd) tracmotion device , srphc82336207-endoscopic submucosal dissection (esd) clutch cutter : 1) it should have s errated jaws and rotating jaws. 2) jaw size should be 5mm. 3) should have a working length of 1800mm . 2) maximum diameter of insertion portion should be 2.7mm. 4) it should have insulated outer edge to minimize the risk of damaging local tissue. 3) it should allow for incision, dissection and coagulation all by the single device, depending on the need of the user during procedure. 5) should be compatible with an endoscope having 2.8mm working channel. ] , srphc82336208-endoscopic submucosal dissection (esd) tracmotion device: 1) it should ha ve a 360 degree rotatable grasper to grasp and re-grasp tissue during esd procedures without compl icated locking mechanism. 2) it should be compatible with a dual channel scope with one channel bein g atleast 3.7mm or more 2) should have working length of 1030mm. 3) device should have maximum inse rtion portion outer diameter of 3.6mm and working length of 1240mm. ]
BOQ
| Sl. No. | Item Description |
|---|---|
| 1 | SRPHC82336207-ENDOSCOPIC SUBMUCOSAL DISSECTION (ESD) CLUTCH CUTTER : 1) IT SHOULD HAVE S ERRATED JAWS AND ROTATING JAWS. 2) JAW SIZE SHOULD BE 5MM. 3) SHOULD HAVE A WORKING LENGTH OF 1800MM . 2) MAXIMUM DIAMETER OF INSERTION PORTION SHOULD BE 2.7MM. 4) IT SHOULD HAVE INSULATED OUTER EDGE TO MINIMIZE THE RISK OF DAMAGING LOCAL TISSUE. 3) IT SHOULD ALLOW FOR INCISION, DISSECTION AND COAGULATION ALL BY THE SINGLE DEVICE, DEPENDING ON THE NEED OF THE USER DURING PROCEDURE. 5) SHOULD BE COMPATIBLE WITH AN ENDOSCOPE HAVING 2.8MM WORKING CHANNEL. ] |
| 2 | SRPHC82336208-ENDOSCOPIC SUBMUCOSAL DISSECTION (ESD) TRACMOTION DEVICE: 1) IT SHOULD HA VE A 360 DEGREE ROTATABLE GRASPER TO GRASP AND RE-GRASP TISSUE DURING ESD PROCEDURES WITHOUT COMPL ICATED LOCKING MECHANISM. 2) IT SHOULD BE COMPATIBLE WITH A DUAL CHANNEL SCOPE WITH ONE CHANNEL BEIN G ATLEAST 3.7MM OR MORE 2) SHOULD HAVE WORKING LENGTH OF 1030MM. 3) DEVICE SHOULD HAVE MAXIMUM INSE RTION PORTION OUTER DIAMETER OF 3.6MM AND WORKING LENGTH OF 1240MM. ] |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender