Tender For Construction Of Sdm Office, Basantgarh. (Under Ut Capex Budget 2026-27)
Tender Value
1.86 Crore
Estimated cost
Bid Submission
11 Sep 2026
8 days left
EMD
3.73 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Udhampur → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Sdm Office, Basantgarh. (Under Ut Capex Budget 2026-27)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 31-Aug-2026 | Corrigendum | Other | 11-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth anddisposal of surplus excavated earth as directed, within a lead of 50 metres All kinds of soil : |
| 2 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material : All kinds of soil : |
| 3 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil : |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 6 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 7 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 9 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 10 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etcupto floor V level, including curing but excluding the cost of centring, shuttering and finishing with. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto / above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases of columns for mass concrete. |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form work for: Retaining walls, return walls, walls (any thickness) including attached pilasters buttresses, plinth and string course fillets, kerbs andsteps etc. |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms. |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for: Edges of slabs and breaks in floors and walls Under 20 cm wide. |
| 17 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete. |
| 18 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 19 | Providing and fixing precoated galvanized iron profile sheets for roof & ridges (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 20 | Providing and fixing roofing consist of 0.8 mm thick galvanizedsteel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like beam, column, joists etc. & concrete of different grade as per design will be paid separately). |
| 21 | Providing and fixing in position factory made non asbestos fibre reinforced aerated cement sandwich wall/roof/floor light weight solid core panels made of light weight cement concrete core composed of OPC cement, pulverized flyash, quick lime, cotton pulp & Gypsum in mortar state mixed with aeration agent in a preset mould. The outer face on both sides of the panels will be non asbestos fibre cement board confirming to IS 14862:2000. These solid wall panels are installed using Galvanized iron steel tracks/C channel of 1mm thick of required sizes as recommended by manufacturer’s and fixed to floor and RCC soffit in plumb to each other with steel screw/ fasteners. The panel shall be fixed vertically with tongue &groove joint with cement based polymer modified jointing compound. The exposed surface finished with fibre mesh/glass fibre tape with polymer based jointing compound having superior flexibility. Panels should be used as floor & roofing with additional structural support, steel or RCC depending upon the design. All the operation shall be completed in all respect as per drawings, Manufacturers specifications and under the overall direction of Engineerin- Charge (Cost of all the material is included except “tracks/C channel” which will be paid separately). Non load bearing panels 75mm thick of required size (minimum 4mm thick fibre cement board) |
| 22 | Providing and fixing, in position concealed G.I section for wall panelling using board of required thickness fixed on the ‘W’ profile (0.55mm thick) having a knurled web of 51.55mm and two flanges of 26mm each with lips of 10.55mm placed @ 610mm C/C in perimeter channel having one flange of 20mm and another flange of 30mm with thickness of 0.55mm and web of length 27mm. Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves @ 610mm C/C with fully threaded self-tapping dry w all screws. Board is fixed to the ‘W’ profile with 25mm countersunk ribbed head screws @ 200mm C/C, all complete as per the drawing and directions of engineer- in-charge. The joints of the boards are finished with specially formulated jointing compound and 48mm wide jointing tape to provide seamless finish Multipurpose cement board reinforced with suitable fibre cement screw. 8 mm thick cement fibre board as per IS : 14862 |
| 23 | Providing and fixing factory made uPVC white colour sliding glazed windowupto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 9.149D.1 Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) |
| 24 | Providing and fixing M.S tubular frames for doors, windows, ventilators and cupboard with rectangular /L-type sections, made of 1.60 mm thick M.S Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer incl. Fixing with carbon steel galvanized dash fastener of required dia and size . |
| 25 | Providing and fixing factory made flush door shutters 30 mm thick made of pre-laminated flat pressed three layer particle board conforming to IS: 12823 exterior grade (Grade I Type II) having one side decorative lamination of approved shade and other side balancing lamination including second class teak wood lipping of 25mm widex12mm thick with necessary screws and black enameled M.S. butt hinges complete as per directions of Engineer- in-charge. |
| 26 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x16 mm. |
| 27 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 150x10 mm. |
| 28 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 125 mm . |
| 29 | Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : Single rubber stopper. |
| 30 | Providing and fixing expansion hold fasteners on CC / R.C.C./brick masonry surface backing including drilling necessary holes and the cost of bolt etc. complete. Fastener with threaded dia 12mm. |
| 31 | Providing and fixing PVC internal wall panelling including all fitings and carrages all job complete |
| 32 | 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 ( 1 cement 6fine sand ) |
| 33 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick. |
| 34 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm). |
| 35 | Wall Painting with acrylic emulsion paint of approved brand andmanufacture to give an even shade. Two or more coats on new work |
| 36 | Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete. |
| 37 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size). |
| 38 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering , all works upto plinth level ( 1 : 2 : 4)1 cement 2 coasre sand 4 stone aggregate grade , with 20mm nominal size . Crushed. |
| 39 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm. |
| 40 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the anufacturer), of 1st quality conforming to IS : 15622, of approved make, laid on 20 mm thick cement mortar 1:4 (1Cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown. |
| 41 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of size 300x450mm as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 42 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 43 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm widex1.6mm thick with flanges of 27mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x40mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.5mm of required length with nuts & bolts of required size and other end of angle hanger fixed with G.I. channels 45x15x0.9 mm running at the spacing of 1200 centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diaX230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre to centre, with 25mm long drive-all screws @ 230 mm interval ,including fixing of gypsum board/calcium silicate board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the gypsum board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers’ specification and also including the cost of making openings for light fittings, grills diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer-in-Charge but excluding the cost of painting with: 8 mm thick Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. |
| 44 | Chequerred precast cement concrete tiles 22mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing, cleaning and curing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) . Dark shade using ordinary cement. |
| 45 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge. |
| 46 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 47 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete. |
| 48 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 49 | Carriage 0f material by mechanical transport including loading ,unloading and stacking completed Sand lead up to 130 km av. |
| 50 | Carriage of material by mechanical transport including loading ,unloading and stacking completed stone aggregate below 40 mm lead up to 60 km. . av. |
| 51 | Plumbing and Sanitary Parts Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid , 10 liter low level white vitreous china flushing cistern and CP flush bend with fittings and C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid. |
| 52 | Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C automatic flushing cistern, with fittings, standard size G.I./ PVC flushpipe for back and front flush with standard spreader pipes with fittings, G.I clamps and in C.P brass coupling complete, including painting offittings and cutting and making good the walls and floors etc. wherever required: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar taps. |
| 53 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 liter white P.V.C automatic flushing cistern. |
| 54 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 55 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: Flexible pipe 32 mm dia |
| 56 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: Waste coupling 31mm of 79 mm length and 62 mm breadth weighing not less than 45gms. |
| 57 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x356 mm . |
| 58 | Providing and fixing toilet paper holder with Flap made out of C.P Brass |
| 59 | Providing and fixing C.P Brass Soap Dish complete job as per direction Engineer in charge. |
| 60 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto1 metre long with S.S. triangular plate to European type W.C. ofquality and make as approved by Engineer - in - charge |
| 61 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with brackets of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.. |
| 62 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms. |
| 63 | Providing and fixing 15mm Nominal Bore C.P brass bib cock of approved quality conforming to IS:8931 |
| 64 | Providing and fixing 15 mm nominal bore C.P. brass angle valve forbasin mixer and geyser points of approved make conforming to IS : 8931 |
| 65 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls -Kitchen sink without drain board 470x420mm bowl depth 178mm. |
| 66 | Providing and fixing soil, waste and vent pipes IS 13592 & fittings (IS: 14735 ) suitable to rubber ring joints , which includes bends, rubber ring, jointing, junctions, clean out plug , cowls, offsets, collar, M.S holder-bat clamps, access pieces, trap of self cleansing design .etc. complete including jointing. 110 mm dia. PVC SWR socketed pipe with rubber ring joints as per IS:13592 Type-B |
| 67 | Providing and fixing soil, waste and vent pipes IS 13592 & fittings (IS: 14735 ) suitable to rubber ring joints , which includes bends, rubber ring, jointing, junctions, clean out plug , cowls, offsets, collar, M.S holder-bat clamps, access pieces, trap of self cleansing design .etc. complete including jointing. 75 mm dia. PVC SWR socketed pipe with rubber ring joints as per IS:13592 Type-B |
| 68 | Providing and fixing of floor Traps 110 mm with double chrome plated cover one Granted and one closed and all other fittins required. |
| 69 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. |
| 70 | Supply, Installation of PVC Gully Trap of Size 110 mm. |
| 71 | Providing & Installation of 1.5 H.P. three phase water pump of make Crompton with all fittings, connecting inlet & outlet, fixtures, electrical connection and starter all complete:- (incl. all carriages). |
| 72 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank lSI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank [Sintex, Electroplast, Star, Lotus or equivalent having valid lSI license] (incl. cost / carriage of material upto roof top). |
| 73 | Providing and fixing CP Brass Single lever telephonic wall mixer ofquality & make as approved by Engineer in charge. 15mm dia |
| 74 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work-exposed on wall with clamps at 1.00 meter spacing 15mm nominal outer dia pipes. |
| 75 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work-exposed on wall with clamps at 1.00 meter spacing 20mm nominal outer dia pipes. |
| 76 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. External work incl. trenching , refilling 32mm nominal outer dia pipes. |
| 77 | Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 16 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 25 mm Diameter |
| 78 | Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 16 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 32 mm Diameter |
| 79 | Supply & fixing CI cover with frame for manhole in sump / septic Tank 455 x 610 mm rectangular CI cover ( light duty ) the weight of the cover to be not less than 23 kg. |
| 80 | Electrical Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-A. |
| 81 | Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 16 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. |
| 82 | 2 X 2.5 SQ.MM + 1 X 2.5 SQ.MM Earth Wire |
| 83 | 2 X 4.0 SQ.MM + 1 X 4.0 SQ.MM Earth Wire |
| 84 | 4 X 6.0 SQ.MM + 2 X 6.0 SQ.MM Earth Wire |
| 85 | 4 X 10.0 SQ.MM + 2 X 6.0 SQ.MM Earth Wire |
| 86 | 4 X 16.0 SQ.MM + 2 X 6.0 SQ.MM Earth Wire |
| 87 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1 x 1.5 sq. mm |
| 88 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 89 | 5/6 amps switch |
| 90 | 3 pin 5/6 amp socket outlet |
| 91 | 15/16 amp switch |
| 92 | 6 pin 15/16 socket outlet |
| 93 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 94 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 95 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 96 | 1 or 2 Module (75mmX75mm) |
| 97 | 3 Module (100mmX75mm) |
| 98 | 4 Module (125mmX75mm) |
| 99 | 6 Module (200mmX75mm) |
| 100 | 8 Module (125mmX125mm) |
| 101 | 12 Module (200mmX150mm) |
| 102 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 103 | Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required. |
| 104 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings |
| 105 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 106 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular DP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 107 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 108 | 4 way (4 + 12), Double door |
| 109 | 6 way (4 + 18), Double door |
| 110 | 8 way (4 + 24), Double door |
| 111 | Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 112 | Single Pole 6 to 32 Amp |
| 113 | Single pole and neutral 6 to 32 Amp |
| 114 | Triple pole and neutral 6 to 32 Amp |
| 115 | Supplying and fixing following rating, Four pole, 415 V, 10 Ka M.C.B in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 116 | Triple pole and neutral 40 Amp |
| 117 | Triple pole and neutral 63 Amp |
| 118 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 119 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 120 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 121 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 122 | Earthing with Copper. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 123 | Providing and fixing 25 mm X 5 mm copper. strip on surface or in recess for connections etc. as required. |
| 124 | Providing and fixing 6 SWG dia copper. wire on surface or in recess for loop earthing as required. |
| 125 | LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 40 watt |
| 126 | Supply installation testing and commissioning of Ceiling Fan 3 Star Rated with Voltage Range 90 V to 300 V,Min. Air Delivery 212 CMM,Service Value 5.3 Cu.m/min/watt,Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required. 1200 mm |
| 127 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 100 Watt |
| 128 | LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . 18 Watt |
| 129 | Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire. 300mm/12\\" sweep exhust fan. |
| 130 | Supply installation testing and commissioning of IP:20 Aluminium Batten 10W-12 W +- 1 W LED Surface Mounted 2 ft. with system lumen efficacy of 100 lm/W and P.F >0.9 THD <20% CCT 6500K,CRI 80 .The LED should have life of 50000 Burning Hours at L70.The input voltage shall be 150 V to 270 V.The fixture should have inbuit surge protection of 2KV. Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab. |
| 131 | SITC of Raw Power Distribution Panel Indoor (IP:42) free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. |
| 132 | SITC of Raw Power Distribution Panel Indoor (IP:42) free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. |
| 133 | INCOMER 100 A,36KA,FPMCCB |
| 134 | Aluminium Bus Bar 200 Amp set of 4 strips 18\\" |
| 135 | Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. |
| 136 | OUTGOINGS Triple pole and neutral 40 Amp |
| 137 | Triple pole and neutral 63 Amp |
| 138 | SITC of DG Power Distribution Panel Indoor (IP:42) free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. |
| 139 | INCOMER 63 A,30KA,FPMCCB |
| 140 | Aluminium Bus Bar 100 Amp set of 4 strips 18\\" |
| 141 | Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. |
| 142 | OUTGOINGS Triple pole and neutral 40 Amp |
| 143 | Triple pole and neutral 32 Amp |
| 144 | SITC of Outdoor Main LT Panel (IP:55) free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/ switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. |
| 145 | INCOMER 160A, 30 KA,FP MCCB |
| 146 | 100A,30 KA,FPMCCB |
| 147 | ON Load Change Over Switch FP 160 amp. (Front operated) |
| 148 | Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set and other necessary relays Required to make it Functional as mentioned in the SLD |
| 149 | 300 A,415 Volts 50Hz Aluminium Busbar set of 4 strips |
| 150 | 200 A,415 Volts 50Hz Aluminium Busbar set of 4 strips |
| 151 | OUTGOINGS 125 A,30 KA,FPMCCB |
| 152 | 100 A,30KA,FPMCCB |
| 153 | 160 A,30KA,FPMCCB |
| 154 | 63 A,30KA,FPMCCB |
| 155 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 156 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 157 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 158 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 159 | 3.5 C X 185 Sq.mm A2XFY |
| 160 | 3.5 C X 95 Sq.mm A2XFY |
| 161 | 3.5 C X 70 Sq.mm A2XFY |
| 162 | 3.5 C X 25 Sq.mm A2XFY |
| 163 | Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required (Comet) |
| 164 | 3½ X 185 sq. mm (57mm) |
| 165 | 3½ X 95 sq. mm (45mm) |
| 166 | 3½ X 70 sq. mm (38mm) |
| 167 | 3½ X 25 sq. mm (28mm) |
| 168 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 m m dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 169 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run). |
| 170 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run). |
| 171 | Supply installation testing and commissioning of 2.2 KVA Sine Wave Inverter , Input 1 Phase 3 wire and output 1 phase 3 wire with 2 Nos of 12 V 200 aH Battery. |
| 172 | Sub Head -I (Wiring) Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) |
| 173 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 174 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet. |
| 175 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required RJ-45 socket outlet. |
| 176 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair. |
| 177 | Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required. 1 run of cable. |
| 178 | Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 6U Rack. |
| 179 | Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. |
| 180 | Copper Patch Cords of length 1m (3ft) |
| 181 | Copper Patch Cords of length 3m (10ft) |
| 182 | Supplying of LED TV(Smart TV) UHD 4K 55\\" |
| 183 | 4MP IP IR Outdoor Bullet Camera Supplying Installation Testing and commissioning of 4MP IP IR Outdoor Bullet Camera having following specifications and features cic 11 Signal System PAL/NTSC, Signal to Noise Ratio: > 50 dB, Camera should display Camera title, Date & Time in live & recorded video 2)image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition(Minimum lumination 0.006 Lus FI 4, AGC ON, 0 lux with IR or bettern True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)-Inbuih IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control, White Balance-Auto, Rack Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking 3) Compression (Minimum); Video: H.265 or better, Audio-G.711U/A, G.711M G.726, AAC. G. 723 4) Wide Dynamic Range:-WDIR (120dB or more) 5) Digital Noise Reduction: DNR (JD) On/Off 6) Video treaming & Frame Rates Triple streaming, configurable Main stream: 4MP (2560×1440) 25/30fps Sub streams minimum: 720P 25/30 fps 7) Image Setting Route Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser. Edge Analytics: Tripwire, Intrusion, Motion Detection 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering. HTTPS, trusted upgrade. |
| 184 | 9) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GR. It should be supplied with minimum 128GB memory Card. 10) Recording Management, Format SD, overwrite, storage management, video to NAS device, 11) Alarm Trigger Motion/tampering detection; network disconnection detection, IP conflict detection, memory card state detection, memory space detection 12) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP. NTP, RTP, HTTP, HTTPS, SNMP TCPAP, PPPOE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 13) System Capability: ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio: It should support 1 x Built-In Mic and 1/1 Alarm In/Out for External Mic. and Speakers as per site requirement, 163 Power Input: The camera should support simultaneous dual power input-12 VDC (via power adapter) and PoE (802.3af)to ensure ontinuo operation in the event of a failure in one power source. 17) Power Requireinent: 12VDC/24 VDC/PoE (802.3af/ePoE 15) Housing/ Enclosure: IP67 weather proof, IK 10, Metallic body 40.4.1 40.4.2 19) Operating Conddition:- Ambient Temperature:-(105°C to 50°C, humidity 95% (max) (non-condensing) 203 IR life: 40000 hours or higher 21) Vidco Bit rate: 32 KBPS-8 MBPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoffS 4MP 25/30fps/@1440P (2560x1440) Outdoor Bullet Camera with 2.7 to 4 mm -12 to 13.5mn or better Varifocal Motorized lens. |
| 185 | Supplying Installation Testing and Commissioning of 2 MP IP IR Dome Camera having following specifications, type of lens and features etc 1) Signal System: PAL/NTSC. Signal to Noise Ratio: >50 dB, Camera should display Camera title, Date & Time se live & recorded viden 2) image Sensor 1/2.8\\" or better progressive Scan CMOS to get color inage even at night condition(Minimum Illumination: 0.006 Lux@ F1.4. AGC ON, 0 lux with IR or better) Truc Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or bester and 30 meter for colour view in might, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control, White Balance Auto, Back Light Compensation, Multi zone Privacy Masking, IILC, Digital Watermarking 3) Compression (Minimuan) -Video: H.265 or better, H.264H, H.264, Audio:-G.711U/A, G.711M. G.726. AAC, G 723 4) Wide Dynamic Range: WDR (120db or more) 5) Digital Noise Reduction - DNR (3D) On/Off 6) Video Streaming & Frame Rates Triple streaming, configurable (Main stream: 2MP 1920×1080),25/30 fps.Sub streams minnar: 720P@25/30 fps). 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser. Edge Analytics: Tripwire, intrusion, Motion Detection 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution. Digest, security logs, account lockout, syslog, video encryption, IP/MAC filtering, HTTPS, uusted upgrade, trusted hoot, 12) Network Protocol SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPOE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSP'S.unicast131 System Capability, ONVIF, Camera shall support open source VMS14) Ethernet: 1 RJ45 10/100 Ethernet port15) Audio: It should support is Built-In Mic and 11 Alarm In' Out for External Mic. and Speakers as per site requirement16) Power Input The camera should support smukancous dual power input-12 VDC (via power adapter) and Pol (802.3af) to ensure continuous operation in the event of a failure in one power source17) Power Requirement 12VDC/24 VAC/PoE (802.3af)/PoE18) Housing Enclosure:-IP67 weather proof, IK10, Metallic body19) Operating Condition: Ansbient Temperature (-105°C to 50°C, humidity 95% (max) (non-condensing)20) IR life: 40000 hours or higher21) Video Bit rate: 32 KBPS-8 MRPS or better221 Standards: BIS with ER, STQC Certified, CE, FCC and RoitS |
| 186 | 9) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memoryn Card 10) Recording Management: Format SD, overwrite, storage management, video to NAS device 11) Alarm Trigger: Motion/tampering detection, audio detection, network disconnection detection, IP conflict detection; memory card state detection, memory space detection space detection 12) Network Protocol SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPOE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSP'S. unicast 13) System Capability, ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ45 10/100 Ethernet port 15) Audio: It should support is Built-In Mic and 11 Alarm In' Out for External Mic. and Speakers as per site requirement 16) Power Input The camera should support smukancous dual power input-12 VDC (via power adapter) and Pol (802.3af) to ensure continuous operation in the event of a failure in one power source 17) Power Requirement 12VDC/24 VAC/PoE (802.3af)/PoE 18) Housing Enclosure:-IP67 weather proof, IK10, Metallic body 19) Operating Condition: Ansbient Temperature (-105°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS-8 MRPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS. |
| 187 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licences to record for all channels having specifications and features etc as mentioned below: 1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses for number of channels of NVR to record per NVR and to provide a live view, storage and simultancously Multi-channel playback of all IP, IR camera or more and must be ONVIF with minimum support of 256Mbps incoming Bandwidth. 2) NVR should support H.265 or better, H.264, MJPEG, MPEG4 support 3) Must support I channel Input, 1 channel Output, RCA for Two-way Talk 4) Intelligent audo power on when power resumes afier power outage. 5) Storage. It should support 5) Connectivity Interface 1 minimum 2 SATA Slots with 20TH capacity/ Slot,Nos x 10/100/1000 Mbps Ethernet Ports, 1x R5485, 1x RS232 7) Backup Interface. Its should have 2. Nosx USB port 1x USB3.0, 1xUSB2.8) Video Output Ports: 1x HDMI and I VGA 9) Alarm Ports. It should have 4/1 Ch In/ Out ports to connect various type of external sensors and output devices like hooter 10) Email & siren cic. SMS Altert options Option for SMS/ Enail Alerts to minimum 5 designated mobile number for power failure, IDD failure, vandalism, tempring, network disconnection and paruc 11) Web & Mobile Application: Web, Mobile app For iPhone, iPad, Android Phone) for alerts and viewing. 12) Protocols: HTTP, HTTPS, TCPAP, IPv4, UDP, NTP, DHCP, DNS, SMTP, UPnP, DDNS, Alarm Server, IP Scarch, Multicast, Auto Registration, ONVIF (Profile T. Profile 5. Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public II need. |
| 188 | 13) Standards: CE, FCC, Rolls and BIS Certifiol Amp of AC100-240V, 50/60Hz Power supply. 14) Power Supply: Should support 12VDC, 15) Operating Condition: Ambient Temperature (-5°C to 50°C), humidity 90% (max) (non-condensing)14) Power Supply: Should support 12VDC, 15) Operating Condition: Ambient Temperature (-5°C to 50°C), humidity 90% (max) (non-condensing) 16) The VMS, NVR application shall support all the features & functionalities of the offered cameras 17) VMS should consist of Base license and Channel Licemes. VMS should be provided with camera Licenses, with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality, (18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage. 19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet 7680x4320 (KK), 3840*2160, 1920×1080, 1280-1024,1280-720, 1024-768 21) Must support recording resolution apto 32MP 22) Must support Continuous, Aların, Motion, Instant, Punic Recording Mode 203 Must support Resolution: 23) When alarm recording is enabled and an event occurs, you can click the alarms icon on morutoring page to view the alert details. The snapshot function is supported on monitoring and playback page. |
| 189 | 24) The Network Vateo Recorder (NVR) shall be configured to send email whenever a system message is created or an alarra event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarin occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm 25) It should support Network Support: HTTP, TCPMP, SMTP, DHCP, DNS, DDNS, FTP, NTP, Convert multiple recording files to one avi/MP4 file UPal, Mulu IP Setting. Search Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection. 26) General Al Based 27) Alarmt otifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd dottribution, heat map, Disk Fuli, Storage Ertor, IP Conflict and almsormal behavior of fan 28) Alarm Noofication should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. 29) Bush-le Artificial Intelligence: NVR should have built-in Al-2 Channel face detection and recognition, Minimum 4 Channel perimeter protection, Minimum & Channel Somart Motion Detection. |
| 190 | 30) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces of more with Face Detection. speed of 12 face images/sec 31) Face & Human Attributes Search: Search Pictures/Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella 32) ANPR Capability: It should support ANPR Camera with Liceuse plate, plate color, vehicle body, vehicle model, vehicle loga, calling, seatbelt, vehicle registration location etc vehicle attributes. 33) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map. Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception 34) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. 35) General Al Based Scarch: Search Pictures by channel, tene, eveni type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection. 36) Smart playback function. Should support smart search for the selected area in the video and smart playback to improve the playback efficiency 37) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics. 16 Channel Network Video Revorder (NVR) having display split-Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16 |
| 191 | Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, ROM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications 6TB (Terabytes) |
| 192 | Supplying and Laying of 20 Mir HDMI Optical Fiber Cable ADC 20, 4K with Randwidth 18Gbps |
| 193 | Supplying and Fixing of S.D Card 256 G.B in the Existing Camera |
| 194 | Supplying and Fixing of SD Card 256 GB in the Existing Camera |
| 195 | Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimaite 20Gbps and packet forwarding rate of 14Mpps or higher. SK MAC table. Internal dual AC Power supply with operating temperature of -5 DC to 50 GC. Juntha frame. 10KB or higher, IGMP Stomping, IGMP Groping qacrict and support fou IGMP Snooping Fast Leave, Should create 250 or mote MLD groups, MLD Snooping, Per VLAN MLD Snooping CMLD Snooping Fast Leave, STP, RSTP. MSTP, Loopback detection, Multicast filtering, VLAN Tagging, QOS: Que per port, WRR, IPv4/IPv6 Interface: minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries, 700 Acess Control entries, SSH CSSL for IPv4 and IPv6, 802.1x, ARP Spoofing, DHCP Snooping and server screening. IP-MAC+Port Binding. Per Port Bandwidth Control 802.1X Authentication (Supports local/RADIUS database, Porn-based Access Control and EAP, OTP TLS. TTLS, PEAP Support) Cable Diagnostic feature, LLDP, LLDP-MED, SNTP/NTP, RMON, SNMP v1,v20 v3 and SNMP Traps, Certifications: UL, CE, FCC, Rats, MTCTE, OEM/Product mast be on Trusted Telecom Pornal of Department of Telecommunication, Cinvernment of India ete, complete as required. 8 port Pol Layer 2 Network Switch with Pot. Support of 130W or higher with each copper port supporting 802.3at PoE+. |
| 196 | Supply Installation, Testing and Commissioning of Media Converter. |
| 197 | Supply & Erection of Termination Box complete as per specification and as desired by EIC. |
| 198 | Supplying and drawing 20 Pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface recessed steel PVC Conduit ete complete as required. |
| 199 | Supplying and drawing following core Multi mode Fiber Optic Cable having corrugated steel armoring, leser optimize 50/125 um with HDPE jacket, LSZH (Low smoke Zero Halogen), Tight-buffered or loose tube, maximum attenuation: <3.5 dB/km at 850 nm, 1.5 dB/km at 1300 rim, bandwidth 2000 MIlz-km at 850 nm, 500 Mitz-km at 1300 nm compliance and certifications: ISO/IEC 11801 Ed. 2.2, ANSI/TIA-568-C3, ITU-T G.651.1 RoHS compliant. Multi Mode Fiber shall be Central-loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS) and HDPE-Sheath, Operating anmbient Temperature should be-50C to +50 OC and Storage Temperature should be-50C to +50 DC, Maximum Atenuation ± 3.5 dB/km at Operational Wavelength 850 nm and ± 1.5 dB/km at Operational Wavelength 1300 nm, type of fiber should be 50/125/G652D & Refractive Index should be 1-483/1 478, The value for Mode-filed.Cladding Diameter 50 2.5 µm and 125 & 1um correspondingly ve splicing & marking ete complete as required. 12 Core Multi Mode Optical Fiber Cable Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 31, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Sep 11, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 8 daysSep 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender