Bids Are invited for Sitc Of Bollard Lights Boom Barrier Metal Detector And Led Neon Style Sign Board At Deep Bhavan
Tender Overview
Project Description
Bids Are invited for Sitc Of Bollard Lights Boom Barrier Metal Detector And Led Neon Style Sign Board At Deep Bhavan Earthwork Excavation And Backfilling For Cable Trenches In All Types Of Soil Incl. Dressing Ramming Watering And Disposal Of Surplus Soil Within 50M Lead. As Per Atc Clause 4.2.1 And 7.1. , Providing And Laying 1 Ratio 3 Ratio 6 Pcc Up To Plinth Using 20Mm Aggregate Incl. Material Labour Tools And Plants As Per Atc Clause 4.2.2 And 7.2. , Providing Laying 1 Ratio 2 Ratio 4 Pcc 40Mm Agg Up To Plinth For 28 Lighted Post Footings Incl Plaster Materials Labor Tools Complete As Per Atc Clause 4.2.3 And 7.3 , Applying Low Voc Water Thinnable Cement Primer On 28 Lighted Post Footings Incl. Materials Labor Tools And Plant Complete As Per Atc Clause 4.2.4 And 7.4. , Two Or More Coats Synthetic Enamel Painting On 28 Lighted Post Footings With Even Shade Incl. Materials Labor Tools And Plants Complete Per Atc Clause 4.2.5 And 7.5. , Supply Install Led Garden Bollard Pole With 15W Led Luminaire Cast Iron 0.5M Height 230-270V Ac 1Ph 50Hz Incl. Material Labour Equipment And Transport As Per Atc 4.2.6, 6.1.1, 7.6. , Supply And Installation Of 1.5 Sq.Mm X 3C Armoured Cabled For Complete Led Garden Bollard Lights Wiring. As Per Atc Clause 4.2.7 And 6.1.2 And 7.7 , Supply And Installation Of 60A 3 Way Bakelite Close Type Connector For Ug Cable And Bollard Light Connection 35Nos. As Per Atc Clause 4.2.8 And 6.1.3 And 7.8 , Supply And Installation Of 1. 5Sq.Mmx3c Pvc Insulated And Sheathed Coper Flexible Cable. As Per Atc Clause 4.2.9 And 6.1.4 And 7.9 , Supply And Installation Of 10A 2P Mcb In Pump House For 2 Loops. As Per Atc Clause 4.2.10 And 6.1.5 And 7.10 , Supply And Installation Of 4 Way Mcb Distribution Board With Phase Neutral And Ground Connection. As Per Atc Clause 4.2.11 And 6.1.6 And 7.11 , Supply And Installation Of 25 Mm Hdpe Pipe From Pump House To Security Gate With Long Bend For Laying Ug Cable On Wall And Underground. As Per Atc Clause 4.2.12 And 6.1.7 And 7.12 , Supply And Installation Of 25 Mm Pvc Pipe Each Pipe Length Of 3 Meter Along With Long Bend And Socket As Per Atc Clause 4.2.13 And 6.1.8 And 7.13 , Supply And Installation Of Digital Voltmeter Indicator Round Or Square Red Yellow And Blue With Container Box As Per Atc Clause 4.2.14 , Supply And Installation Of 63A Tpn Switch Fuse Unit With Encloser On Panel Board In Pump House Including Removal Of Existing Tpn Switch Fuse Unit. As Per Atc Clause 4.2.15 And 6.1.9 And 7.15 , Supply And Installation Of 100A 415V Four Pole Copper Bus Box In Pump House At Deep Bhavan. As Per Atc Clause 4.2.16 And 6.1.10 And 7.16 - Supply And Installation Of 100A 415V Four Pole Copper Bus Box In Pump House At Deep Bhavan. As Per Atc Clause 4.2.16 And 6.1.10 And 7.16 , Supply Installation Testing And Commissioning Of Automatic Electromechanical Boom Barrier 4 To 6M Lane With Safety Features Access Control Integration As Per Atc 4.2.17 And 6.1.12 And 7.17. , Supply And Testing Of Hand Held Metal Detector With Lithium Battery Along With Battery Charging Cable And Charger Kit. As Per Atc Clause 4.2.18 And 6.1.13 And 7.18 , Supply Install Testing Led Sign Board Deep Bhavan In Hindi English Gujarati 20X15 Ft 3 Ft Letters Acp With Gi Structure Red Yellow White Led Incl. All Charges As Per Atc 4.2.19 And 6.1.14 And 7.19. , Miscellaneous Work As Per Atc 4.2.20 And 7.20.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Earthwork excavation and backfilling for cable trenches in all types of soil incl. dressing ramming watering and disposal of surplus soil within 50m lead. As per ATC clause 4.2.1 and 7.1. | Earthwork excavation and backfilling for cable trenches in all types of soil incl. dressing ramming watering and disposal of surplus soil within 50m lead. As per ATC clause 4.2.1 and 7.1. |
| 2 | Providing and laying 1 ratio 3 ratio 6 PCC up to plinth using 20mm aggregate incl. material labour tools and plants as Per ATC clause 4.2.2 and 7.2. | Providing and laying 1 ratio 3 ratio 6 PCC up to plinth using 20mm aggregate incl. material labour tools and plants as Per ATC clause 4.2.2 and 7.2. |
| 3 | Providing laying 1 ratio 2 ratio 4 PCC 40mm agg up to plinth for 28 lighted post footings incl plaster materials labor tools complete as per ATC clause 4.2.3 and 7.3 | Providing laying 1 ratio 2 ratio 4 PCC 40mm agg up to plinth for 28 lighted post footings incl plaster materials labor tools complete as per ATC clause 4.2.3 and 7.3 |
| 4 | Applying low VOC water thinnable cement primer on 28 lighted post footings incl. materials labor tools and plant complete as per ATC clause 4.2.4 and 7.4. | Applying low VOC water thinnable cement primer on 28 lighted post footings incl. materials labor tools and plant complete as per ATC clause 4.2.4 and 7.4. |
| 5 | Two or more coats synthetic enamel painting on 28 lighted post footings with even shade incl. materials labor tools and plants complete per ATC clause 4.2.5 and 7.5. | Two or more coats synthetic enamel painting on 28 lighted post footings with even shade incl. materials labor tools and plants complete per ATC clause 4.2.5 and 7.5. |
| 6 | Supply install LED garden bollard pole with 15W LED luminaire cast iron 0.5m height 230-270V AC 1Ph 50Hz incl. material labour equipment and transport as per ATC 4.2.6, 6.1.1, 7.6. | Supply install LED garden bollard pole with 15W LED luminaire cast iron 0.5m height 230-270V AC 1Ph 50Hz incl. material labour equipment and transport as per ATC 4.2.6, 6.1.1, 7.6. |
| 7 | Supply and installation of 1.5 Sq.mm x 3C Armoured cabled for complete LED Garden Bollard lights wiring. As per ATC clause 4.2.7 and 6.1.2 and 7.7 | Supply and installation of 1.5 Sq.mm x 3C Armoured cabled for complete LED Garden Bollard lights wiring. As per ATC clause 4.2.7 and 6.1.2 and 7.7 |
| 8 | Supply and installation of 60A 3 Way Bakelite close type connector for UG cable and bollard light connection 35Nos. As per ATC clause 4.2.8 and 6.1.3 and 7.8 | Supply and installation of 60A 3 Way Bakelite close type connector for UG cable and bollard light connection 35Nos. As per ATC clause 4.2.8 and 6.1.3 and 7.8 |
| 9 | Supply and installation of 1. 5sq.mmX3C PVC insulated and sheathed coper flexible cable. As per ATC clause 4.2.9 and 6.1.4 and 7.9 | Supply and installation of 1. 5sq.mmX3C PVC insulated and sheathed coper flexible cable. As per ATC clause 4.2.9 and 6.1.4 and 7.9 |
| 10 | Supply and installation of 10A 2P MCB in Pump House for 2 loops. As per ATC clause 4.2.10 and 6.1.5 and 7.10 | Supply and installation of 10A 2P MCB in Pump House for 2 loops. As per ATC clause 4.2.10 and 6.1.5 and 7.10 |
| 11 | Supply and installation of 4 Way MCB Distribution Board with phase neutral and ground connection. As per ATC clause 4.2.11 and 6.1.6 and 7.11 | Supply and installation of 4 Way MCB Distribution Board with phase neutral and ground connection. As per ATC clause 4.2.11 and 6.1.6 and 7.11 |
| 12 | Supply and installation of 25 mm HDPE pipe from Pump house to security gate with long bend for laying UG cable on wall and underground. As per ATC clause 4.2.12 and 6.1.7 and 7.12 | Supply and installation of 25 mm HDPE pipe from Pump house to security gate with long bend for laying UG cable on wall and underground. As per ATC clause 4.2.12 and 6.1.7 and 7.12 |
| 13 | Supply and installation of 25 mm PVC Pipe each pipe length of 3 meter along with long bend and socket as per ATC clause 4.2.13 and 6.1.8 and 7.13 | Supply and installation of 25 mm PVC Pipe each pipe length of 3 meter along with long bend and socket as per ATC clause 4.2.13 and 6.1.8 and 7.13 |
| 14 | Supply and installation of Digital voltmeter indicator Round or Square Red Yellow and Blue with container box as per ATC clause 4.2.14 | Supply and installation of Digital voltmeter indicator Round or Square Red Yellow and Blue with container box as per ATC clause 4.2.14 |
| 15 | Supply and installation of 63A TPN switch fuse unit with encloser on panel board in Pump House including removal of existing TPN switch fuse unit. As per ATC clause 4.2.15 and 6.1.9 and 7.15 | Supply and installation of 63A TPN switch fuse unit with encloser on panel board in Pump House including removal of existing TPN switch fuse unit. As per ATC clause 4.2.15 and 6.1.9 and 7.15 |
| 16 | Supply and installation of 100A 415V Four Pole Copper Bus Box in Pump House at Deep Bhavan. As per ATC clause 4.2.16 and 6.1.10 and 7.16 | Supply and installation of 100A 415V Four Pole Copper Bus Box in Pump House at Deep Bhavan. As per ATC clause 4.2.16 and 6.1.10 and 7.16 |
| 17 | Supply installation testing and commissioning of automatic electromechanical boom barrier 4 to 6m lane with safety features access control integration as per ATC 4.2.17 and 6.1.12 and 7.17. | Supply installation testing and commissioning of automatic electromechanical boom barrier 4 to 6m lane with safety features access control integration as per ATC 4.2.17 and 6.1.12 and 7.17. |
| 18 | Supply and testing of Hand Held Metal Detector with Lithium battery along with battery charging cable and charger kit. As per ATC clause 4.2.18 and 6.1.13 and 7.18 | Supply and testing of Hand Held Metal Detector with Lithium battery along with battery charging cable and charger kit. As per ATC clause 4.2.18 and 6.1.13 and 7.18 |
| 19 | Supply install testing LED sign board DEEP BHAVAN in Hindi English Gujarati 20x15 ft 3 ft letters ACP with GI structure Red Yellow White LED incl. all charges as per ATC 4.2.19 and 6.1.14 and 7.19. | Supply install testing LED sign board DEEP BHAVAN in Hindi English Gujarati 20x15 ft 3 ft letters ACP with GI structure Red Yellow White LED incl. all charges as per ATC 4.2.19 and 6.1.14 and 7.19. |
| 20 | Miscellaneous work as per ATC 4.2.20 and 7.20. | Miscellaneous work as per ATC 4.2.20 and 7.20. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender