Power Boards / Undertakings / PSU Closing in 1 days TDR #57172047

Bids Are invited for Cylinder Mountable-Gas- Co2- Pressure Regulating Valves- Dual Stage, Make-Baldota As Per Specification , Cylinder Mountable-Gas-Helium Baldota Make Dual Stage Diaphragm Type Regulator As Per Specificatiion , Cylinder Mountable Fo

Issued by Boards / Undertakings / PSU · Tapi, Gujarat
Tender Value
Ref. Documents
Estimated cost
Bid Submission
04 Sep 2026
1 days left
EMD
38367
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tapi → Gujarat
EMD Exemption
Not Available
Quantity
42

Project Description

Bids Are invited for Cylinder Mountable-Gas- Co2- Pressure Regulating Valves- Dual Stage, Make-Baldota As Per Specification , Cylinder Mountable-Gas-Helium Baldota Make Dual Stage Diaphragm Type Regulator As Per Specificatiion , Cylinder Mountable For Oxygen Gas Prv-Baldota Make Dual Stage Diaphragm Type Regulator As Per Spec. , Cylinder Mountable- Gas- Nitrogen-Pressure Regulating Valves-Dual Stage, Make- Baldota As Per Spec. - Cylinder Mountable-Gas- Co2- Pressure Regulating Valves- Dual Stage, Make - Baldota, Inlet Pressure: Max 80 Kg/Cm2 (Co2 Cylinder Pressure), Body: Ss, Outlet Pressure: 0 - 15 Kg/Cm2, Medium: Carbon Di-Oxide, Inlet Connection: 1/2 Fnpt, Outlet Connection: 1/2 Fnpt, Inlet Entry: Left Side Of Prv Front, Inlet And Outlet Shall Be 180 Deg Opposite To Each Other, Flow: 20 M3/Hr Maximum. Inlet Pressure Gauge: 0- 100 Kg/Cm2, Outlet Pressure Gauge: 0 - 16 Kg/Cm2, With Pre Filter Of 5 Micron Relief Valve At Outlet: Set At 10 Kg/Cm2 Note: Inlet Gauge, Outlet Gauge, 5 Micron Pre-Filter & Rv Shall Not Connected To Prv & Kept Loose. + Separate Adaptor Male & Female For Standard Cylinder. , Cylinder Mountable-Gas- Helium Baldota Make Dual Stage Diaphragm Type Regulators- For Helium Service Body – Ss 316 Diaphragm- Ss 316L Inlet- 0-210 Kg/Cm22 Outlet Pressure- 0-7 Kg/Cm2 Inlet Conn : ¼ Nptf, Outlet Conn : ¼ Nptf Relief Valve At Outlet: Set At 10 Kg/Cm2 Note: Inlet Gauge, Outlet Gauge, 5 Micron Pre-Filter & Rv Shall Not Connected To Prv & Kept Loose.+ Separate Adaptor Male & Female For Standard Cylinder , Cylinder Mountable For Oxygen Gas Prv- Baldota Make Dual Stage Diaphragm Type Regulators- For Oxygen Service Body – Ss 316 Diaphragm- Ss 316L Inlet- 0-120 Kg/Cm22 Outlet Pressure- 0-7 Kg/Cm2 Inlet Conn : ¼ Nptf, Outlet Conn : ¼ Nptf Relief Valve At Outlet: Set At 10 Kg/Cm2 Note: Inlet Gauge, Outlet Gauge, 5 Micron Pre-Filter & Rv Shall Not Connected To Prv & Kept Loose. + Separate Adaptor Male & Female For Standard Cylinder. , Cylinder Mountable-Gas- Nitrogen-Pressure Regulating Valves- Dual Stage, Make - Baldota, Inlet Pressure: Max 210 Kg/Cm2 (Nitrogen Cylinder Pressure), Body: Ss, Outlet Pressure: 0 - 15 Kg/Cm2, Medium: Carbon Di-Oxide, Inlet Connection: 1/2 Fnpt, Outlet Connection: 1/2 Fnpt, Inlet Entry: Left Side Of Prv Front, Inlet And Outlet Shall Be 180 Deg Opposite To Each Other, Flow: 20 M3/Hr Maximum. Inlet Pressure Gauge: 0- 280 Kg/Cm2, Outlet Pressure Gauge: 0 - 16 Kg/Cm2, With Pre Filter Of 5 Micron Relief Valve At Outlet: Set At 12 Kg/Cm2 . Note: Inlet Gauge, Outlet Gauge, 5 Micron Pre-Filter & Rv Shall Not Connected To Prv & Kept Loose + Separate Adaptor Male & Female For Standard Cylinder.

BOQ

Sl. No. Item TitleItem Description
1Cylinder mountable-Gas- CO2- Pressure Regulating Valves- Dual Stage, Make - Baldota, Inlet Pressure: Max 80 Kg/cm2 (CO2 cylinder pressure), Body: SS, Outlet pressure: 0 - 15 Kg/cm2, Medium: Carbon Di-Oxide, Inlet connection: 1/2\\" FNPT, Outlet connection: 1/2\\" FNPT, Inlet Entry: Left side of PRV front, Inlet and outlet shall be 180 Deg Opposite to each other, Flow: 20 m3/Hr Maximum. Inlet Pressure gauge: 0- 100 kg/cm2, Outlet Pressure Gauge: 0 - 16 Kg/cm2, with pre filter of 5 Micron Relief Valve at outlet: Set at 10 Kg/cm2 Note: Inlet gauge, outlet gauge, 5 Micron pre-filter & RV shall not connected to PRV & kept loose. + Separate Adaptor Male & female for standard cylinder.Cylinder mountable-Gas- CO2- Pressure Regulating Valves- Dual Stage, Make - Baldota, Inlet Pressure: Max 80 Kg/cm2 (CO2 cylinder pressure), Body: SS, Outlet pressure: 0 - 15 Kg/cm2, Medium: Carbon Di-Oxide, Inlet connection: 1/2\\" FNPT, Outlet connection: 1/2\\" FNPT, Inlet Entry: Left side of PRV front, Inlet and outlet shall be 180 Deg Opposite to each other, Flow: 20 m3/Hr Maximum. Inlet Pressure gauge: 0- 100 kg/cm2, Outlet Pressure Gauge: 0 - 16 Kg/cm2, with pre filter of 5 Micron Relief Valve at outlet: Set at 10 Kg/cm2 Note: Inlet gauge, outlet gauge, 5 Micron pre-filter & RV shall not connected to PRV & kept loose. + Separate Adaptor Male & female for standard cylinder.
2Cylinder mountable-Gas- Helium BALDOTA make Dual Stage Diaphragm type regulators- for HELIUM SERVICE Body – SS 316 Diaphragm- SS 316L Inlet- 0-210 kg/cm22 Outlet Pressure- 0-7 kg/cm2 Inlet Conn : ¼” NPTF, Outlet Conn : ¼” NPTF Relief Valve at outlet: Set at 10 Kg/cm2 Note: Inlet gauge, outlet gauge, 5 Micron pre-filter & RV shall not connected to PRV & kept loose.+ Separate Adaptor Male & female for standard cylinderCylinder mountable-Gas- Helium BALDOTA make Dual Stage Diaphragm type regulators- for HELIUM SERVICE Body – SS 316 Diaphragm- SS 316L Inlet- 0-210 kg/cm22 Outlet Pressure- 0-7 kg/cm2 Inlet Conn : ¼” NPTF, Outlet Conn : ¼” NPTF Relief Valve at outlet: Set at 10 Kg/cm2 Note: Inlet gauge, outlet gauge, 5 Micron pre-filter & RV shall not connected to PRV & kept loose.+ Separate Adaptor Male & female for standard cylinder
3Cylinder Mountable for Oxygen Gas PRV- BALDOTA make dual Stage Diaphragm type regulators- for OXYGEN SERVICE Body – SS 316 Diaphragm- SS 316L Inlet- 0-120 kg/cm22 Outlet Pressure- 0-7 kg/cm2 Inlet Conn : ¼” NPTF, Outlet Conn : ¼” NPTF Relief Valve at outlet: Set at 10 Kg/cm2 Note: Inlet gauge, outlet gauge, 5 Micron pre-filter & RV shall not connected to PRV & kept loose. + Separate Adaptor Male & female for standard cylinder.Cylinder Mountable for Oxygen Gas PRV- BALDOTA make dual Stage Diaphragm type regulators- for OXYGEN SERVICE Body – SS 316 Diaphragm- SS 316L Inlet- 0-120 kg/cm22 Outlet Pressure- 0-7 kg/cm2 Inlet Conn : ¼” NPTF, Outlet Conn : ¼” NPTF Relief Valve at outlet: Set at 10 Kg/cm2 Note: Inlet gauge, outlet gauge, 5 Micron pre-filter & RV shall not connected to PRV & kept loose. + Separate Adaptor Male & female for standard cylinder.
4Cylinder mountable-Gas- Nitrogen-Pressure Regulating Valves- Dual Stage, Make - Baldota, Inlet Pressure: Max 210 Kg/cm2 (Nitrogen cylinder pressure), Body: SS, Outlet pressure: 0 - 15 Kg/cm2, Medium: Carbon Di-Oxide, Inlet connection: 1/2\\" FNPT, Outlet connection: 1/2\\" FNPT, Inlet Entry: Left side of PRV front, Inlet and outlet shall be 180 Deg Opposite to each other, Flow: 20 m3/Hr Maximum. Inlet Pressure gauge: 0- 280 kg/cm2, Outlet Pressure Gauge: 0 - 16 Kg/cm2, with pre filter of 5 Micron Relief Valve at outlet: Set at 12 Kg/cm2 . Note: Inlet gauge, outlet gauge, 5 Micron pre-filter & RV shall not connected to PRV & kept loose + Separate Adaptor Male & female for standard cylinder.Cylinder mountable-Gas- Nitrogen-Pressure Regulating Valves- Dual Stage, Make - Baldota, Inlet Pressure: Max 210 Kg/cm2 (Nitrogen cylinder pressure), Body: SS, Outlet pressure: 0 - 15 Kg/cm2, Medium: Carbon Di-Oxide, Inlet connection: 1/2\\" FNPT, Outlet connection: 1/2\\" FNPT, Inlet Entry: Left side of PRV front, Inlet and outlet shall be 180 Deg Opposite to each other, Flow: 20 m3/Hr Maximum. Inlet Pressure gauge: 0- 280 kg/cm2, Outlet Pressure Gauge: 0 - 16 Kg/cm2, with pre filter of 5 Micron Relief Valve at outlet: Set at 12 Kg/cm2 . Note: Inlet gauge, outlet gauge, 5 Micron pre-filter & RV shall not connected to PRV & kept loose + Separate Adaptor Male & female for standard cylinder.

AI Tender Summary

OUR REF NO 57172047
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 04-09-2026
Authority
Authority Name Nuclear Power Corporation Of India Limited
Work Description Bids Are invited for Cylinder Mountable-Gas- Co2- Pressure Regulating Valves- Dual Stage, Make-Baldota As Per Specification , Cylinder Mountable-Gas-Helium Baldota Make Dual Stage Diaphragm Type Regulator As Per Specificatiion , Cylinder Mountable For Oxygen Gas Prv-Baldota Make Dual Stage Diaphragm Type Regulator As Per Spec. , Cylinder Mountable- Gas- Nitrogen-Pressure Regulating Valves-Dual Stage, Make- Baldota As Per Spec. - Cylinder Mountable-Gas- Co2- Pressure Regulating Valves- Dual Stage, Make - Baldota, Inlet Pressure: Max 80 Kg/Cm2 (Co2 Cylinder Pressure), Body: Ss, Outlet Pressure: 0 - 15 Kg/Cm2, Medium: Carbon Di-Oxide, Inlet Connection: 1/2 Fnpt, Outlet Connection: 1/2 Fnpt, Inlet Entry: Left Side Of Prv Front, Inlet And Outlet Shall Be 180 Deg Opposite To Each Other, Flow: 20 M3/Hr Maximum. Inlet Pressure Gauge: 0- 100 Kg/Cm2, Outlet Pressure Gauge: 0 - 16 Kg/Cm2, With Pre Filter Of 5 Micron Relief Valve At Outlet: Set At 10 Kg/Cm2 Note: Inlet Gauge, Outlet Gauge, 5 Micron Pre-Filter & Rv Shall Not Connected To Prv & Kept Loose. + Separate Adaptor Male & Female For Standard Cylinder. , Cylinder Mountable-Gas- Helium Baldota Make Dual Stage Diaphragm Type Regulators- For Helium Service Body – Ss 316 Diaphragm- Ss 316L Inlet- 0-210 Kg/Cm22 Outlet Pressure- 0-7 Kg/Cm2 Inlet Conn : ¼ Nptf, Outlet Conn : ¼ Nptf Relief Valve At Outlet: Set At 10 Kg/Cm2 Note: Inlet Gauge, Outlet Gauge, 5 Micron Pre-Filter & Rv Shall Not Connected To Prv & Kept Loose.+ Separate Adaptor Male & Female For Standard Cylinder , Cylinder Mountable For Oxygen Gas Prv- Baldota Make Dual Stage Diaphragm Type Regulators- For Oxygen Service Body – Ss 316 Diaphragm- Ss 316L Inlet- 0-120 Kg/Cm22 Outlet Pressure- 0-7 Kg/Cm2 Inlet Conn : ¼ Nptf, Outlet Conn : ¼ Nptf Relief Valve At Outlet: Set At 10 Kg/Cm2 Note: Inlet Gauge, Outlet Gauge, 5 Micron Pre-Filter & Rv Shall Not Connected To Prv & Kept Loose. + Separate Adaptor Male & Female For Standard Cylinder. , Cylinder Mountable-Gas- Nitrogen-Pressure Regulating Valves- Dual Stage, Make - Baldota, Inlet Pressure: Max 210 Kg/Cm2 (Nitrogen Cylinder Pressure), Body: Ss, Outlet Pressure: 0 - 15 Kg/Cm2, Medium: Carbon Di-Oxide, Inlet Connection: 1/2 Fnpt, Outlet Connection: 1/2 Fnpt, Inlet Entry: Left Side Of Prv Front, Inlet And Outlet Shall Be 180 Deg Opposite To Each Other, Flow: 20 M3/Hr Maximum. Inlet Pressure Gauge: 0- 280 Kg/Cm2, Outlet Pressure Gauge: 0 - 16 Kg/Cm2, With Pre Filter Of 5 Micron Relief Valve At Outlet: Set At 12 Kg/Cm2 . Note: Inlet Gauge, Outlet Gauge, 5 Micron Pre-Filter & Rv Shall Not Connected To Prv & Kept Loose + Separate Adaptor Male & Female For Standard Cylinder.
Basic Detail
Tender No GEM/2026/B/7944699
Bidding Type Tender
Location
City Tapi
State Gujarat
Key Dates
Publish Date 24 Aug 2026
Submission Date 04 Sep 2026
Open Date 04 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 38367
Exemption Not Available
Document List
45e87054-3ba9-4fa8-801e-0c844ce75c02.pdf
1787286684.xlsx
spec_1_2026-08-21-09-45-08_da59b0083cf3163ae51e08f2f76e9ce1.pdf
spec_2_2026-08-21-09-48-19_9d36a1e450a75818b3d7b451e803134f.pdf
spec_3_2026-08-21-09-50-02_91ca7ad2f9a3db235a66aa7e5c52e4cc.pdf
spec_4_2026-08-21-09-51-53_c0571b66d419b160ce16afd5d0c33b6e.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Sep 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
pdf

45e87054-3ba9-4fa8-801e-0c844ce75c02.pdf

xlsx

1787286684.xlsx

pdf

spec_1_2026-08-21-09-45-08_da59b0083cf3163ae51e08f2f76e9ce1.pdf

pdf

spec_2_2026-08-21-09-48-19_9d36a1e450a75818b3d7b451e803134f.pdf

pdf

spec_3_2026-08-21-09-50-02_91ca7ad2f9a3db235a66aa7e5c52e4cc.pdf

pdf

spec_4_2026-08-21-09-51-53_c0571b66d419b160ce16afd5d0c33b6e.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders