Public Administrative Department Local Bodies Closing in 6 days TDR #57171289

Tender For Repair & Maintenance Of Street Light System In Ward No. 25&27 In 2026 Under Electrical Sub Division No. 3, Chandigarh.

Issued by Local Bodies · Chandigarh, Chandigarh
Tender Value
4.99 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
6 days left
EMD
9992
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair & Maintenance Of Street Light System In Ward No. 25&27 In 2026 Under Electrical Sub Division No. 3, Chandigarh.

BOQ

Name of Work:- Repair & Maintenance of street light system in Ward No. 25&27 in 2026 under Electrical Sub Division No. 3, Chandigarh.
Sl. No. Item Description
1S/E of Collars of CC Collars including following:- a) The box shall be enclosed in a cement collar made form cement concrete 1:2:4 with outside dia. 16”.b) The collar shall be embedded in the ground up to 6” shall stand 9” above ground shall have housed 10” high SMC Box and 6” top over the box.c) The collar shall be provided with 2 PVC Pipes of 40mm dia. and 45cm long to facilitate entry of cables in the Jn.Box.d)n The collar shall be plastered properly finished, curing and painted with 2 coats of snowcem of superior quality. (e) Providing and Fing Junction box of size 250x200x100mm inside dimensions of thermosetting sheet moulding compound material of robust construction with double hinge, side clamp locking arrangement, provision for MCB/Kit installatin provision alongwith connector strip of 30 amps rating suitable for minimum 4x16 sq.mm aluminium cable termination. The junction box should have two numbers PVC Glands with sufficient space for cable entry and loose wires complete in all respect to the best satisfaction of Engg.in.charge.
2S/E of CC Collars including following:- a) The box shall be enclosed in a cement collar made from cement concrete 1:2:4 with outside dia. 20”.b) The collar shall be embedded in the ground up to 6” shall stand 9” above ground shall have housed junction Box and 6” top over the box.c) The collar shall be provided with 2 GI Pipe of 40mm dia. and 45cm long to facilitate entry of cables in the Jn.Box.d)n The collar shall be plastered properly finished, curing and painted with 2 coats of snowcem of superior quality. (e) Providing and Fixing Junction box of size 250x200x100mm inside dimensions of thermosetting sheet moulding compound material of robust construction with double hinge, side clamp locking arrangement, provision for MCB/Kit installation provision alongwith connector strip of 30 amps rating suitable for minimum 4x16 sq.mm aluminium cable termination. The junction box should have two/three numbers PVC Glands with sufficient space for cable entry and loose wires.(f) The job includes making the holes at the bottom of pole using gas cutting for cable & wire entry.
3G.I. Earth pipe electrode with salt/ Charcoal:-Supply and laying of earth electrode made out of ISI marked 'B' class G.I. pipe 4.5 Mtr. long 40 mm dia including accessories. GI pipe electrode shall be cut tapered at the bottom, and provided with holes of 12mm dia, drilled not less than 7.5 cm from each other upto 2 Mtr. of length from bottom. The earth electode shall be laid in ground after boring as per CPWD specifications complete in all respect and to the entire satisfaction of the engineer-in-charge.
4P/F 6 SWG GI earth wire : Providing & laying earth connection from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G.I. pipe from earth electrode, as required.
5Supply & laying of ISI marked 4 core 16 mm sq PVC INSULATED Aluminium armoured cable loose in trench/ pipe:-Supply & laying of ISI marked 4 core 16 mm sq Aluminum conductor armoured cable of make Havell's/ Finolex/ Ecko/ Lapp/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable shall be laid as per DSR Code 7.5.1 . The job included all Connections, Commissioning and testing of phase. Supply complete in all respective to the entire satisfaction of the Engineer in charge.
6Supply & Laying of DWC pipe 50/63mm with hand bockey:-Supply and laying of 50/63 mm (I/D& O/D) Double Wall Corrugated (DWC) High Density Polyethylene pipe (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm conforming to IS 14930 (P-II) and PSEN-50086 (P-I & II) of Make Duraline/Rex/Zen duct/Gemini. The pipe should be laid 3 feet below ground/road level with hand bockey without cutting of road for laying cables etc. including cost of digging and refilling of pits complete in all respects to the entire satisfaction of Engineer-in-Charge.
7Supply & Laying of DWC pipe 50/63mm with out hand bockey:-Supply and laying of 50/63 mm (I/D& O/D) Double Wall Corrugated (DWC) High Density Polyethylene pipe (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm conforming to IS 14930 (P-II) and PSEN-50086 (P-I & II) of Make Duraline/Rex/Zen duct /Gemini. The pipe should be laid 75 cm below ground/road level by digging the ground or cutting the road/paver blocks upto required level & laying of DWC pipe for laying L.T. (up to 1.1 KV grade) cables etc. including cost of digging and refilling of pits/Trench complete in all respects to the entire satisfaction of Engineer-in-Charge of work.
8Dismantling of old broken CC Collar and junction box and Digging of Existing Loops Upto 1 Mtr Below in Kutcha/Pakka Floor, Cutting, Dressing and Reconnections with Thimbles /Nuts &Bolts Complete in the Jn.Box And Lifting Any Malba From Site And Dumping at the C&D plant Industrial Area Phase-I.
9Painting and Numbering of 7.5/10 mtr long existing street light pole above ground level with two coats of Al. paint of superior quality alongwith single/ double/ triple arm/ round bracket. The pole surface should be cleaned well by removing dust/rust & other depositions .The job includes cost of labour required for holding the ladder and controlling the traffic while using crane/ boom.Numbering on the pole be done on two sides on each pole by painting 4\\" dia round with yellow paint and make number with black paint. The Cement collar around the pole should be painted with two coats of good quality white colored snowcem. The job includes the cost of paint of existing Junction box cover with Red paint and any other petty material require to complete the job to the entire satisfaction of Engineer-in-charge
10Supply & Laying of flexible PVC insulated FR PVC sheathed 3 Core 2.5 mm2 aluminium Cable conforming to IS -694:2010 of make KEI,Havells ,Cirtina / finolex , Polycab within the9 mtr Steel tubular / Octagonal pole and within bracket fitted on pole.The job include the cost of other petty material required to complete the job to the entire satisfaction of engineer –in – change precautions of the work.
11Providing and fixing of Pedestal Cover of size 1200x900x350 mm (16 SWG Sheet) with hinges, Red Paint 2 coat after red oxide primer , Fabrication, Welding & labour at site All T&P as required to the best satisfaction to the Engineer in-Charge.
12Providing and fixing of Pedestal Cover of size 900x600x350 mm (16 SWG Sheet) with hinges, Red Paint 2 coat after red oxide primer , Fabrication, Welding & labour at site All T&P as required to the best satisfaction to the Engineer in-Charge.
13Supply and erection of Junction Box cover of fibre sheet of 20\\"X5\\"/suitable size on existing octagonal pole. The fibre cover shall be installed on existing junction box with the help of screw. The job includes the cost of all labour charges and other petty material,nut & bolts required to complete the job upto entire satisfaction of Engineer-in-Charge.
14Providing and fixing of CCMS Cover of size 622x546 mm with hinges, Grey Paint 2 coat after red oxide primer, Fabrication, Welding & labour at site All T&P and Knob for door as required to the best satisfaction to the Engineer in-Charge.
15Painting of pedestal size 1200x900x350mm/900x600x350mm with P.O. red paint complete in all respect and bonding to the existing earth etc. and platform of cement concrete 1:2:4 around the pillar box of size 3’x2’x0’-4”. The work shall be executed to the entire satisfaction of Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57171289
AUTHORITY Local Bodies
TENDER VALUE 4.99 Lakhs
LAST DATE 31-08-2026
Authority
Authority Name Municipal Corporation
Work Description Tender for Repair & Maintenance Of Street Light System In Ward No. 25&27 In 2026 Under Electrical Sub Division No. 3, Chandigarh.
Basic Detail
Tender No 152/E/MCC/2026
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 24 Aug 2026
Submission Date 31 Aug 2026
Open Date 31 Aug 2026
Finance
Tender Value 4.99 Lakhs
Tender Fee Ref. Documents
EMD 9992
Exemption Not Available
Document List
6f74ba98-6f14-4b8e-8164-bd82f62465c3.html
BOQ_116582.xls
Tendernotice_1 (21).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Aug 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

6f74ba98-6f14-4b8e-8164-bd82f62465c3.html

xls

BOQ_116582.xls

pdf

Tendernotice_1 (21).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders