Tender For Renovation Of Electrical Installation Work At District Hospital, Dharmanagar, North Tripura. (Second Call)

Issued by Government Departments · tripura, Tripura
Tender Value
1.25 Crore
Estimated cost
Bid Submission
05 Sep 2026
10 days left
EMD
2.50 Lakhs
Bank guarantee accepted
Document Fee
4000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
tripura → Tripura
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Renovation Of Electrical Installation Work At District Hospital, Dharmanagar, North Tripura. (Second Call)

BOQ

Name of Work:- Renovation of Electrical installation work at District Hospital, Dharmanagar, North Tripura. (SECOND CALL)
Sl. No. Item Description
1Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required.
2Short Point
3Medium Point
4Long Point
5Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.
62 X 1.5 sq mm
72 X 2.5 sq mm
82 X 4 sq mm
94 X 6 sq mm
104 X 10 sq mm
114 X 16 sq mm
124 X 25 sq mm
134 X 35 sq mm
14Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required
151 X 1.5 sq mm
162 X 2.5 sq mm
172 X 4 sq mm
182 X 6 sq mm
192 X 10 sq mm
20Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:-
21Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:-
22Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required.
231-2 module plastic switch board
24Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required.
251-2 Module
26Supplying and fixing of the following modular accessories including necessary connection etc. as required.
2720/25 amps single phase motor starter switch (2M)
284 step fan regulator (1M)
293/6 pin 25 amps socket outlet (2M)
30Bell push SP (1M) :-
31Buzzer call bell (1M):-
32Providing earthing system with maintenance free earthing electrode of 50 mm dia & 3 mtr long of dual electrode technology filled with highly conductive compound and back fill compound of 2 nos. 25 kg bag, terminal size 32mmx 6mm including accessories with masonry enclosure of CI cover plate size 12\\"x 12\\" having locking arrangement including CC works etc as required.
33Supply and fixing of 25mm x 3mm Copper on walls/ floor of the building for horizontal/ vertical network including necessary spacers and porcelain insulators at regular intervals.
34Supplying, Installation of Lighting Arrestor, ESE Lightning conductor LAP CX-040 with GI mast 5.00 mtrs long with base plate 250x 250x3 mm, Bakelite Insulator, Mounting Accessories, (Stay wire-15.00 mtrs + Pin fasten -08 Hook/ Ring Fastener-3 nos, U clamp-3 nos), Lighting Counter, Test Link, Earthing(Copper Rod 3 mtrs, 25kg chemical, Polyplastic cover) and 45 m long 70 sq. mm single core flexible copper cable:-
35Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement- 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size):-
36Centering shuttering including struttings, propping etc. and removal of form work for: Foundations, footings, bases for columns etc. for mass concrete with timber plank.
37Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W)
38Supplying & installation of 300 mm sweep 900 rpm metalic body exhaust fan including connection etc as required (ISI marked)
39Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required.
40Dismantling the existing ceiling fan and making winding by (34/35/36 S.W.G) Copper wire, varnish, oiling, greasing and re-fixing the same including wiring the down rod of standard length ( up to 30 cm ) etc. as required :-
41Supplying of 400 mm sweep AC wall mounting fan with metal blade etc as required.
42Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-
43Recessed/Surface mounted 1ft x 1ft decorative 16/18 watt LED panel light with integral driver and high quality polycarbonate diffuser:-
44Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):-
45Recessed/Surface mounted 2ft x 2ft decorative 36 watt LED panel light with integral driver and high quality polycarbonate diffuser
4643pplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-
4790 watt LED street light fixture with integral driver and secondary lens (IP 66)
48Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-
4918/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):-
5012 watt LED retrofit lamp with polycarbonate body and aluminium heatsink
51Supplying, installation, testing & commissioning of powder coated prewired panel board suitable for 415 volts TP MCCB as incomer & outgoing including busbar & connection as required of the following ratings & sizes:-
524 way TP MCCB outgoing & TP MCCB incomer upto 400 amps
536 way TP MCCB outgoing & TP MCCB incomer upto 400 amps
54Supplying, installation, testing & commissioning of powder coated prewired digital meter module complete with ammeter, voltmeter, phase indicator lamp, control fuses, CTs, in the existing panel board including connection etc. as required:-
55Supplying, installation, testing & commissioning of powder coated side cable module (1 pair) in the existing panel board including connection etc. as required suitable for the following sizes and ratings:-
564/6 way outgoing and incomer upto 400 amps
57Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN /FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required.
584 way vertical TPN MCB DB suitable for FP MCCB incomer upto 125 amps (Double door):-
598 way horizontal TPN MCB DB (Double door):-
606 way horizontal TPN MCB DB (Double door):-
614 way horizental TPN MCB DB (Double door)
624 way SPN MCB DB (double door)
63Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):-
6416 to 100 amps TP MCCB, Breaking capacity 16/18KA (Thermal Magnetic)
65125 amps TP MCCB, Breaking capacity 25KA (Thermal Magnetic)
66250 amps TP MCCB, Breaking capacity 36KA (Thermal Magnetic)
6716 to 100 amps FP MCCB, Breaking capacity 16/18KA (Thermal Magnetic)
68Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:-
696 to 32 amps SP MCB
706 to 32 amps TPN MCB
7140/50/63 amps TP MCB
7240/50/63 amps TPN MCB
73Supplying & installation of following switchgear accessories including connection etc as required.
74Copper Spreader links/terminals (Set of 8) for 16A-125A FP MCCB
75Copper Spreader links/terminals (Set of 8) for 160A-250A FP MCCB.
76Supplying & installation of Digital timer Switch including necessary connection etc as required:-
77Supplying & installation of following power contactors including necessary connection etc as required:-
783 pole 9 amps (AC3) power contactors with 1NO+1NC Aux. Contact.
79Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable : -
801.5 sqmm - 4 sqmm Cable:-
81Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required.
823 core 4 Sq mm
833.5 core 50 Sq mm
843.5 core 120 Sq mm
85Supplying and fixing of aluminium terminal ends (LUGS) - long barrel of following sizes.
8650 sq mm
87120 sq mm
88Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes.
896 sq mm
9010 sq mm
9116 sq mm
9225 sq mm
9335 sq mm
94Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:-
95Drawing of armoured/un-armoured cable with proper saddling etc as required.
96Supplying, installation, testing and commissioning of following ratings online UPS with inbuilt isolation transformer, 50/60Hz (Auto sensing) frequency, P.F range 0.95-0.99, voltage regulation +/-1%, Pure sine wave form, total harmonic distortion < 5% with full load, Noise level 50db at 1m, LED indication for Normal mode/Load on battery/Load on bypass/System fault, Audible alarm for Mains failure, low battery, Overload, fault and Bypass mode complete with M. S Rack for mounting battery bank, Battery inter link cables and all other necessary accessories including connections etc. as required
971 kVA, 1 Ph input/1 Ph output Online UPS with 3024 VAH battery bank for minimum 2 hours Backup
98Supplying & installation of Surge Protection Device (SPD) of following ratings in the existing Panels/MCB DBs including necessay connections etc as required.
99Surge Protection Device (SPD, withdrawable) (Type-2) with Imax 70 KA (3P+N)
100Supplying, installation, testing & commissioning of cubical type, extensible, bolted construction TTA LT Panel as per IEC-61439-1&2 test61439-1&2 , IAC as per IEC-61641 for 50KA for 0.3 sec. Panel shall be supplied with a double door arrangement. Global Door/ glass door IK10 tested shall be provided as front door to allow maintenance staff to visually access device status, meter readings, indicating lamp status without opening the door ,IP54 ingress protection when door closed, IP20 protection in door open condition.Global door shall be provided with Ergonomic handles with locking (key RONIS n° 405). Panel shall be suitable for 415 V, 3 Phase, 4 wire 50 Hz AC supply system of suitable size fabricated in compartmentalized design from CRCA sheet steel of 2mm thick , 3mm thick for gland plates i/c cleaning & finishing complete with 9 tank process for powder coating in approved shade, having 2000 Amp capacity extensible type TPN Aluminium bus bars with colour coated heat shrinkable sleeves,moulded type busbar insulator ( FRP insulator not acceptable)with short circuit withstand capacity of 50KA for 1 Sec.,maximum height of the panel shall be limited to 2100mm bottom base channel of MS section not less than 100mm x 50mm x 3mm thick. Fabrication shall be done in trasportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AL bus bars and control wiring with .
1012.5 Sq.mm FRLS . PVC insulated copper conductor S/C cable for voltage & Current respectively, cable alleys, cable gland plates in two half, i/c providing following switch gears : (Note Panel shall be suitable to recieve busduct entry from Transformer ) Panel shall be provided with QR scanner code to log the SLD of the panel digitally and all the catalogue of the equipement installed inside the panel. Wireless Sensor to be provided to analyze gases and microparticles inside the switchboard, by concentrating air into the sensor (with the help of an aspiration fan), applying a smart algorithm to sort internal cable issues from overheating. The monitoring shall be done by a sensor that communicates both wirelessly and via Modbus RTU to a hooter/sounder.Sensor device should not replace any fire protection device of the installation.
102(I) Incomings:Incomer : 1) 433V (Uimp=12KV peak), Icu@433V=Ics=Icw for 1 sec =50KA, 2000A, modular type 4P Air Circuit breaker with break time (<40 mili sesond) , manual draw out type with microprocessor based LSIGN release having adjustable overload with alarm indicator and time delay, short circuit with time delay, Instantaneous current, Earth fault with time delay and adjustable neutral protection - N, N/2, OFF, test facility and inbuilt Metring for Current-, last 10 trip history, breaker ageing data with Spring Charge Signal Switch, comprising of at least 5 current settings in LSIG and 5 time settings in LSG,.ready to close indication shall be provided with breaker. Beaker shall be able to store last 10 fault histrory, maximum demand with date & time stamping and communicate the energy monitoring data to remote 3rd party scada /energy monitoring system. 2) 2000A 4p onload changeover shall provide in incomer section.(a) Digitsl flush pattern type Voltmeter (0-500 V) with selector switch & back up MCBs … complete 1set.(b) Digital flush pattern type Ammeter (0-2000 Amp) with selector switch and one set of 3 Nos. CTs of ratio 2000/5A class 1 accuracy and 15 VA burden - 1 set.(c) Indicating lamp On, OFF, TRIP /R/Y/B/Ready to close…complete 1setd) MFM with class 1 accuracy with Rs485 port
103Bus Bars:TPN with neutral alluminium bus bars of minimum of 2000 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 50KA for 1 Sec.Outgoing:Each set comprising of 1 no.400A Icu=Ics=36 kA FP Thermal Magnetic based double break roto operative MCCB with O/L (40%-100%),S/C release with Aux Contact for On/Off/Trip/ with extended rotary Operating Handle' & 'Door Interlock. MCCB feeder shall be equipped with 1.- Indicating lamps ON/OFF/TRIP), Set of Control MCB & accessories as required.as per Schneider Easypact CVS series .complete 4 sets. Each set comprising of 1 no.250A Icu=Ics=36 kA FP Thermal Magnetic based double break roto operative MCCB with O/L (40%-100%),S/C release with Aux Contact for On/Off/Trip/ with extended rotary Operating Handle' & 'Door Interlock. MCCB feeder shall be equipped with 1.- Indicating lamps ON/OFF/TRIP), Set of Control MCB & accessories as required.as per Schneider Easypact CVS series complete 1 sets.
104Each set comprising of 1 no.125A Icu=Ics=36 kA FP Thermal Magnetic based double break roto operative MCCB with O/L (40%-100%),S/C release with Aux Contact for On/Off/Trip/ with extended rotary Operating Handle' & 'Door Interlock. MCCB feeder shall be equipped with 1.- Indicating lamps ON/OFF/TRIP), Set of Control MCB & accessories as required.as per Schneider Easypact CVS series complete 1 sets. Each set comprising of 1 no.100A Icu=Ics=36 kA FP Thermal Magnetic based double break roto operative MCCB with O/L (40%-100%),S/C release with Aux Contact for On/Off/Trip/ with extended rotary Operating Handle' & 'Door Interlock. MCCB feeder shall be equipped with 1.- Indicating lamps ON/OFF/TRIP), Set of Control MCB & accessories as required.as per Schneider Easypact CVS series complete 3 sets. Each set comprising of 1 no 63A Icu=Ics=36 kA FP Thermal Magnetic based double break roto operative MCCB with O/L (40%-100%),S/C release with Aux Contact for On/Off/Trip/ with extended rotary Operating Handle' & 'Door Interlock. MCCB feeder shall be equipped with 1.- Indicating lamps ON/OFF/TRIP), Set of Control MCB & accessories as required.as per Schneider Easypact CVS series .complete 2 sets.
105Each set comprising of 1 no 32A Icu=Ics=36 kA FP Thermal Magnetic based double break roto operative MCCB with O/L (40%-100%),S/C release with Aux Contact for On/Off/Trip/ with extended rotary Operating Handle' & 'Door Interlock. MCCB feeder shall be equipped with 1.- Indicating lamps ON/OFF/TRIP), Set of Control MCB & accessories as required.as per Schneider Easypact CVS series .complete 1 sets. 1.- Indicating lamps ON/OFF/TRIP), Set of Control MCB & accessories as required.as per Schneider Easypact CVS series .complete 3 sets. Approximate Panel Diemension : H-2075 X W-3000 X D-1000/600 mm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57171195
AUTHORITY Government Departments
TENDER VALUE 1.25 Crore
LAST DATE 05-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for Renovation Of Electrical Installation Work At District Hospital, Dharmanagar, North Tripura. (Second Call)
Basic Detail
Tender No ACE/PU/PWD/B/E/DNIT/10/2026-27
Bidding Type Tender
Location
City tripura
State Tripura
Key Dates
Publish Date 24 Aug 2026
Submission Date 05 Sep 2026
Open Date 07 Sep 2026
Finance
Tender Value 1.25 Crore
Tender Fee 4000
EMD 2.50 Lakhs
Exemption Available
Document List
a554f8b9-7f20-496b-9df8-c1cc9f694206.html
BOQ_77616.xls
DNIeT10ACEPUSecondCall.pdf
Tendernotice_1 (21).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Sep 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days