Drinking Water Supply and Sanitation Government Departments Closing in 3 days TDR #57169780

Tender For Execution Of Rural Piped Water Supply Scheme To Dhonodamal In The Village Jharigaon Of G.P Jharigaon Under Jharigaon Block In Nabarangpur District Including 5 Years O&M. (New)

Issued by Government Departments · Nabarangpur, Odisha
Tender Value
1.80 Crore
Estimated cost
Bid Submission
02 Sep 2026
3 days left
EMD
1.80 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nabarangpur → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Execution Of Rural Piped Water Supply Scheme To Dhonodamal In The Village Jharigaon Of G.P Jharigaon Under Jharigaon Block In Nabarangpur District Including 5 Years O&M. (New)

BOQ

Name of Work:- EXECUTION OF RURAL PIPED WATER SUPPLY SCHEME TO DHONODAMAL IN THE VILLAGE JHARIGAON OF G.P JHARIGAON UNDER JHARIGAON BLOCK IN NABARANGPUR DISTRICT INCLUDING 5 YEARS O&M. (NEW)
Sl. No. Item Description
1RPWS TO ZONE-I VILL. JHARIGAON (DHONODAMAL) :- Head WorksSupplying all labour T&P for Construction of Platrform for Production well as per direction of Engineering In Charge.
2Approach RoadSupplying all labour T&P for Construction of Approch Road of Length 10 mtr as per direction of Engineering In Charge.
3Supplying all labour T & P for earth work for foundation and plinth / pipe line in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge .
4Supplying all labour T & P for spreading or dressing of moorum & sand.
5Moorum
6Supplying all labour T & P for cement Concrete (1:2:4) with 12mm size hard granite chips per 1cum
7Supplying all labour T & P fo Rigid and smooth centering for R.C.C works including false works and dismantling them after casting including cost of materials complete in ground floor.
8Pump HouseSupplying all labour T&P for Construction of pump house near source as per direction of Engineering In Charge.
9Supplying all labour T & P for earth work for foundation in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge.
10Supplying all materials , labour T & P for filling in foundation and plinths with sand well watered and rammed including cost,carriage & royality of all materials etc. all complete & as per direction of Engineer-In-Charge
11Supplying all labour T & P materials providing C.C (1:3:6)with 40 mm CBG metal including cost,conveyance and royality of materials etc all complete& as per direction of Engineer-In-Charge
12Supplying all labour T & P materilas providing RCC work of M-20 grade with 20 mm & down grade black hard granite crusher broken stone chips including hosting & laying cost, conveyance and royalty of materials etc. all complete as per the direction of Engineer-In-Charge
13Add 10 % extra on labour rate for slope roof quantity
14Supplying all labour T & P for solid cement concrete block machine mixed and Hydraulic compressed having crushing strength not less than 75 kg / cm² in CM (1:6) in foundation and plinth per cum.
15Supplying all labour T & P for rigid and smooth centering, shuttering for R.C.C work including false works & dismantling them after casting including cost of materials complete in ground floor.
16Foundation ,Column , Plinth Bend
17Lintel
18Roof , Chhaja
19Supplying all labour T & P for fitting & fixing uncoated HYSD Bar reinforcement including cutting, bending ,binding,shifting to site including cost of material etc complete as per the direction of Engineer-In-Charge.
20Supplying all labour T & P fo brick work in super structure with bricks 23cm X 11cm X 8cm size having crushing strength not less than 75 Kg/cm² with dimensional tolerence ±8 percent in cement motar (1:6) for superstrustructure per 1 cum
21Supplying all labour T & P for 12 mm thick in cement plaster in cement mortar (1:6) for brick work
22Supplying all labour T & P for 2.5cm artificial stone flooring with cement concrete (1:2:4) including punning using 12mm size hard broken granite chips
23Supplying all labour T & P for vitrified premium grade floor tiles of (300 mm x 300 mm) having thickness 8 mm to 10 mm confirming to IS-4457
24Supplying all labour T & P for White washing two coats with shell lime per sqm
25Supplying all labour T & P for wall painting 2 coats with plastic emulsion paint of approved shade on old work to give an even shade including cost of paint per 1 sqm
26Supplying all labour T & P for finishing wall with Weather Coat of approved shade on new work two coat to give an even shade including cost of paint.
27Supplying all labour T & P for M.S door including making, fitting , fixing and transportation to site as per direction of Engineer-In-Charge
28Pump House Door
29Toilet Door
30Window
31Supplying all labour T & P for fitting & fixing of seramic Indian pan for toilet room inluding all cost transportation etc all complete as per direction of Engineer-In-charge.(Including all fittings)
32Supplying all labour T & P for R.C.C ring for 0.9 mtr dia including transporting ,excavation, fixing and placing in position of soakpit .
33Supplying all labour T & P for R.C.C cover plate including transporting , fixing and placing in position of soakpit .
34Supplying all labour T & P for writing information and draw a logo of BASUDHA
35Internal ElectrificationSupplying all labour T&P for Internal Electrification for pump house as per direction of Engineering In Charge.
36Recessed wiring to light point with 1.5 sqmm FR PVC insulted single core multistand copper conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 5 AMP 250 V piano type switch ISI marked and ceiling rose ISI Marked mounted on MS box having front bakelite cover of suitable size,MS box with 1.00 sqm FR PVC insulted single core multistrand copper conductor and earth wire including all accessories and connection as per direction of Engineer in charge (make of wire = finollex / L &T / Anchor / Havels / V-Guard) (deducting the cost of S/F of 100 mm x 100 mm x 60 mm MS box with bakelite cover - 1 no )
37do-…………group A (1.1.1-1.24.2)
38do-…………group B (1.1.1-1.24.2)
39do-…………group C(1.1.1-1.24.2)
40Recessed wiring to Fan point in
41do-…………group C(1.1.1-1.24.2)
42S/F of 5amp switch & socket out let of ISI marked on existing board (1.25.1 &1.25.4)
43S/F of metal box 180mm x 100mm x 60mm deep (Nominal size) in recess switch suitable size of phenolic laminated sheet in front including providing and fixing 5 pin 15/16 amp. Piano type switch connection, painting etc. as required (1.27)
44Wiring for circuit / sub-main wiring along with earth wire with following size of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire-finolex/L&T/Anchor/Havels/V-Guard)
452 x 1.5 sqmm + 1 x 1.5 sqmm
462 x 4 sqmm + 1 x 1.5 sqmm
47S/F of bbattan holder BK angle holder ISI marked including connection etc. instead of ceiling rose (1.29-1.28)
48Supply,installation, testing and commision of DP main switch (IS-13940 part 3/1993) on existing surface/wall mounting & complete with H.R.C. fuse links, inter connections earthing etc. as required as per direction of engnieer in-charge (Make-Simens/HPL/Anchor/L&T) 32amp. D.P. -do-
49do- 63amp. T.P.N. Main switch with bus bar
50do- 32amp. T.P.N. Main switch on the pannel board
51S/F of 'B' series SP MCB of 6 amp. Rating 240 volt 'B' series MCB for lighting and other loads in the exiting MCB Distribution board ISI marked complete with connection, tesitng and commissioning etc. as required single pole(2.6.1)
52S/F of 4 way single pole and neutral sheet MCB distribution board 250 bolt on surface / recess complete with tinned copper bus bar, neutral bar , earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required
53S/F of 16/18 SWG metal box of following sizes (Nominal size) in recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required
54150 mm x 100 mm x 60 mm deep (1.24.4)
55180 mm x 100 mm x 60 mm deep (1.24.5)
56Earthing with G.I earth pipe 3 mtrs. Long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe with charcoal and salt as required (3.4 + 3.6 )
57Supply and laying of 6 SWG G.I wire ISI marked at 0.5 mtr. Below ground level for conductor earth electrode including soldering etc. as required (3.8)
58S / F of 1200 mm A.C ceiling fan with all accessories and connections without fan regulator (Khaitan-Magnet / Anchor - XL)
59Supply. Installation, Testing and commissioning of bulkhead fittings including fixing of 8 watt CFL lamp with die cast aluminium housing and frosted glass cover (Make-Havels )
60Supply. Installation, Testing and commissioning of 2 x 27 watt energy efficient T-5 street light fitting including fixing of 24 watt T-5 Lamps-2 nos. including fixing of bracket and all accessories as per direction of engineer. (make - Bajaj/Havels)
61S/ F of electric step type fan regulator of ISI marked
62S /F of 18 watt CFL lamp
63S /F of Fan hook \\"S\\" type made of 16 mm MS Road
64S /F of 63/ 100 A kit kat type Fuse cut out on the surface of the pannel board
65S/F of Pannel Board of 3' x 4' size (made of 6mm thick m/s sheet and 25mmx25mmx6mm m/s angle with proper pointing) on the wall surface
66Compund WallSupplying all labour T&P for Construction of 80 mtr Compound wall for Pump house & OHT as per direction of Engineering In Charge.
67Supplying all labour T & P for earth work for foundation in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge per 100 cum.
68Supplying all materials, labor, T&P for filling the foundation with sand watered and rammed with all cost, conveyance and royalities as per direction of Engineer-in-charge
69Supplying all labour T & P for cement Concrete (1:3:6) with 4cm size hard granite metal per 1cum as per direction of Engineer-in-charge
70Supplying all labour T & P for R.C.C work of M-20 grade with 20mm and down grade black hard granite(crusher broken) stone chips including hoisting and laying as per direction of Engineer-in-charge
71Supplying all labour T & P for rigid and smooth centering, shuttering for R.C.C work including false works & dismantling them after casting including cost of materials complete in ground floor as per direction of Engineer-in-charge
72Foundation Below Plinth bend
73Column & Plinth Bend
74Supplying all labour T & P for random rubble H.G stone Masonry in cement mortar (1:6) in foundation and plinth per 1 cum.
75Supplying all labour T & P for fitting & fixing uncoated HYSD Bar reinforcement including cutting, bending ,binding,shifting to site including cost of material etc complete as per the direction of Engineer-In-Charge.
76Supplying all labour T & P fo brick work in super structure with bricks 23cm X 11cm X 8cm size having crushing strength not less than 75 Kg/cm² with dimensional tolerence ±8 percent in cement motar (1:6) for superstructure per 1 cum as per direction of Engineer-in-charge
77Supplying all labour T & P for 12mm thick cement plaster (1:6) on brick work per length of 50 mtr as per direction of Engineer-in-charge
78Supplying all labour T & P for White washing two coats with shell lime per sqm as per direction of Engineer-in-charge
79Supplying all labour T & P for finishing wall with Weather Coat of approved shade on new work two coat to give an even shade including cost of paint. as per direction of Engineer-in-charge
80supply labour T & P Fitting and fixing with colour washing / painting of 4 mtr length Grill gate.
81Installation of Pump and MotorSupply, installation, testing and commissioning of variable voltage star rated, ISI/BIS and ISO certified, three phase vertical submersible 3 HP pump set of working head of 68 mtr and 1.80 lps from Source to OHT (5 nos Pump sets including 100% stand-by)
82Electric driven vertical submersible pump set(SD) of 3-phase having Head of 68 mtr & Discharge 1.80 LPS, Kirloskar,KSB,LUBI make. (3 HP)
83Supplying ,installing commissionig & testing of ISI marked Motor control panel board suitable for above pump set with suitable volt meter & Ampere meter (if not in the control pannel volt meter & Ampere meter will be fitted separately).
84Supplying ,installing commissionig & testing of ISI marked 100 AMP main switch suitable for above pump set .
8525 sq. mm Armoured 4 core Aluminium cable reputed make .
866 sq. mm copper Submersiable flat cable reputed make like .
87M.S.Angle frame with suitable nut & bolt with painting.for pannel boards.
88Double ended Flanged G.I Pipe of 50mm dia.D/F of medium quality with required nut,bolt,rubber insertion.
89Supplying all labour T&P for lowering of pump and motor into production well up to the required depth including jointing to rising main,cable jointing with required materials & cost of transportation to site etc.all complete as per direction of Engineer in charge.
9050 x 80 mm both side flanged G.I tapper of 0.40 mtr. Length..
9150 mm x 90 degree G.I Bend D/F of size ( .30 x .30 ) m
92Supplying, fabricating and fixing MS Angle Supports 50 mm × 50 mm × 6 mm, 1.0 m long, including drilling, welding, and fixing 12 SWG (2.64 mm) GI Barbed Wire over the existing 80 Meter boundary wall, including binding wire, clamps, fixing accessories
93Installation of Pump and Motor(Sump to OHT)Supply, installation, testing and commissioning of variable voltage star rated, ISI/BIS and ISO certified, three phase Horizontal submersible 5 HP pump set of working head of 36 mtr and 1.58 lps from Sump to OHT (5 nos Pump sets including 100% stand-by)
94Electric driven Horizontal submersible pump set(SD) of 3-phase having Head of 36 mtr & Discharge 1.58 LPS, Kirloskar, KSB, LUBI make. (5.00 HP)
95Supplying ,installing commissionig & testing of ISI marked Motor control panel board suitable for above pump set with suitable volt meter & Ampere meter (if not in the control pannel volt meter & Ampere meter will be fitted separately).
96Supplying ,installing commissionig & testing of ISI marked 100 AMP main switch suitable for above pump set .
9725 sq. mm Armoured 4 core Aluminium cable reputed make .
9810 sq. mm copper Submersiable flat cable reputed make like .
99M.S.Angle frame with suitable nut & bolt with painting.for pannel boards.
100Double ended Flanged G.I Pipe of 80mm dia.D/F of medium quality with required nut,bolt,rubber insertion.
101Supplying all labour T&P for lowering of pump and motor into production well up to the required depth including jointing to rising main,cable jointing with required materials & cost of transportation to site etc.all complete as per direction of Engineer in charge.
10250 x 80 mm both side flanged G.I tapper of 0.40 mtr. Length..
10350 mm x 90 degree G.I Bend D/F of size ( .30 x .30 ) m
104Supply of all labour T & P, material for soil testing, supply of design, drawing, construction, errection, testing & commissioning etc of RCC elevated storage reservoir with dome using RCC M25, 2 nos. ISI marked suitable dia sluice valve , 1No of suitable dia butter fly valve & it’s RCC valve chambers as per approved drawing , supplying fitting & fixing of suitable medium grade GI pipe make confirming to IS specification of required length from percolation well to ESR & ESR to distribution main including CI/GI for in-let, out let, over flow& washing line of ESR, RCC stair case with suitable dia structural stainless with suitable dia structural stainless steel hand rail around dome & landing etc. And stainless steel ladder outside & aluminium ladder inside, lightening arrester confirming to IS specification water level indicator. (Construction of Duck Bed above the ground level for supporting of Inlet and Outlet Pipe & Clamping of all the pipe with the Column)- (70 KL ESR OF 15 MTR STAGGING)
105Design, drawing, construction, errection, testing & commissioning etc of RCC On Ground reservoir OR Sump of different capacity with dome shape covering using RCC M25 grade by supplying all materials, labour, equipment T & P including testing of soil to ascertain the SBC & other parameters required for design etc fitting & fixing of suitable medium grade GI pipe make confirming to IS specification of required length CI/GI for in-let, out let, over flow& fixing of CI paddle collars on the wall of container etc all complete as per the direction of engineer-in-charge(50 KL SUMP)
106Raising Main & Distribution SystemSupplying of all labour T & P for Earth work excavation in trenches for DI/ HDPE pipe lines in all kinds of soils within 50 M initial lead & 1.5 M intial lift including rough dressing and breaking clods to maximum 5 cm to 7 cm & laying in layers not exceeding 0.3 m in depth etc all complete as per the direction of engineer in-charge.(160 mm HDPE pipe ,110 mm HDPE pipe ,90 mm HDPE Pipe )
107Supplying of all labour T & P for filling in foundation trenches with excavated materials as directed by the Engineer-In-Charge of earth work for cum (Ordinary Soil)
108Supplying all material labour ,T&P & laying in trenches HDPE pipes conforming to IS 4984-1995 and specials of following Out side diameter and class-1 to class-3 and jointing by fusion welding method including testingas per specification complete. and as per the direction of engineer in charge . Including all Fittings and fixing.(110 mm HDPE pipe (PN-10))
109Supplying all labour ,T&P & laying and jointing GI pipes, fittings & specials of approved make excluding earthwork in excavation & refilling of trenches & including cost of pipe as per specification,transportation,taxes, & testing of pipe etc & febrication in case of metalic pipe all complete and as per the direction of engineer in charge
110100 mm GI pipe (MEDIUM)
11180 mm GI pipe (MEDIUM)
112Supplying all material labour ,T&P & laying in trenches HDPE pipes conforming to IS 4984-1995 and specials of following Out side diameter and class-1 to class-3 and jointing by fusion welding method including testingas per specification complete. and as per the direction of engineer in charge . Including all Fittings
113160 mm HDPE Pipe (PN-6)
114110 mm HDPE Pipe (PN-6)
11590 mm HDPE Pipe (PN-6)
116Supply all labour T&P fitting and fixing of C.I sluice valves with double flanged ends in the water line for controlling purposes conforming to IS: 14846-2000 for the following rating and nominal diameters as per specifications complete of approved make with supply of all joining materials, T&P etc all complete including cost of all materials and fittings etc all complete as per direction of engineer-in-charge.
11780mm CI Sluice Valve
118100 mm CI Sluice Valve
119150 mm CI Sluice Valve
120100 mm CI NR Valve
121Supply and fitting & fixing of CI Air Valve of approved make with supply of Jointing materials T&P etc all complete as per the direction of Engineer-In-Charge.
12215mm Air Valve
123Supply all labour T&P fitting and fixing of construction of Valve Chamber for Sluice Valve & NR Valve complete as directed by the engineer in-charge..
124Supply all labour T&P fitting and fixing of construction of Valve Chamber for Air Valve complete as directed by the engineer in-charge..
125Dismantling the C.C roads and removing including stacking the useful materials for reuse and removing the debris within 50m. Lead including all labour & T&P required for the work complete as directed by the engineer in-charge. (320 mtr x 0.41 mtr x 0.20 mtr)
126Supplying all labour T&P for cement concrete (1:2:4) with 12mm size hard granite chips per 1 cum. ( ref pg no.44, SL -7, analysis of rates) (320 mtr x 0.41 mtr x 0.20 mtr)
127Supply all labour T&P fitting,fixing and Installation of Functional Household Tap Connection from the existing ferrule point to the household Premises.
128Supply all labour T&P fitting and fixing of construction of Stand alone for Govt. Institution.(1000Ltr. Storage)
129Supply all materials, labour, T& P and providing and fixing IEC hoarding board of size 1.00m (4') x 0.91m (3'). The hoarding frame 25mm x25mm x 3mm thick hollow square stainless stell bar supporting with 25mm x 25mm x 2mm size stainless steel bar in middle- 2 nos. covered with 1.6mm thick steel plate, fixing of IEC Message over teh board (Flex banner of 6' x 4' size) as per desing specification including 2 nos. 55mm dia stainless steel pipe of 2mm thickness support pillar including earthwork in excavation in foundation in all kids of soil, Cement concrete (1:2:4) with 12 mm size HG chips with cost. carriage, royality and taxes of all materials, welding, buffing, polishing and labour etc. all complete as per direction of Enginner in Charge.
130RPWS TO ZONE-II VILL: JHARIGAON (BALAJI SAHI)Head WorksSupplying all labour T&P for Construction of Platrform for Production well as per direction of Engineering In Charge.
131Approach RoadSupplying all labour T&P for Construction of Approch Road of Length 10 mtr as per direction of Engineering In Charge.
132Supplying all labour T & P for earth work for foundation and plinth / pipe line in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge .
133Supplying all labour T & P for spreading or dressing of moorum & sand .
134Moorum
135Supplying all labour T & P for cement Concrete (1:2:4) with 12mm size hard granite chips per 1cum
136Supplying all labour T & P fo Rigid and smooth centering for R.C.C works including false works and dismantling them after casting including cost of materials complete in ground floor.
137Pump HouseSupplying all labour T & P for earth work for foundation in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge.
138Supplying all materials , labour T & P for filling in foundation and plinths with sand well watered and rammed including cost,carriage & royality of all materials etc. all complete & as per direction of Engineer-In-Charge
139Supplying all labour T & P materials providing C.C (1:3:6)with 40 mm CBG metal including cost,conveyance and royality of materials etc all complete& as per direction of Engineer-In-Charge
140Supplying all labour T & P materilas providing RCC work of M-20 grade with 20 mm & down grade black hard granite crusher broken stone chips including hosting & laying cost, conveyance and royalty of materials etc. all complete as per the direction of Engineer-In-Charge
141Add 10 % extra on labour rate for slope roof quantity
142Supplying all labour T & P for solid cement concrete block machine mixed and Hydraulic compressed having crushing strength not less than 75 kg / cm² in CM (1:6) in foundation and plinth per cum.
143Supplying all labour T & P for rigid and smooth centering, shuttering for R.C.C work including false works & dismantling them after casting including cost of materials complete in ground floor.
144Foundation ,Column , Plinth Bend
145Lintel
146Roof , Chhaja
147Supplying all labour T & P for fitting & fixing uncoated HYSD Bar reinforcement including cutting, bending ,binding,shifting to site including cost of material etc complete as per the direction of Engineer-In-Charge.
148Supplying all labour T & P fo brick work in super structure with bricks 23cm X 11cm X 8cm size having crushing strength not less than 75 Kg/cm² with dimensional tolerence ±8 percent in cement motar (1:6) for superstrustructure per 1 cum
149Supplying all labour T & P for 12 mm thick in cement plaster in cement mortar (1:6) for brick work
150Supplying all labour T & P for 2.5cm artificial stone flooring with cement concrete (1:2:4) including punning using 12mm size hard broken granite chips
151Supplying all labour T & P for vitrified premium grade floor tiles of (300 mm x 300 mm) having thickness 8 mm to 10 mm confirming to IS-4457
152Supplying all labour T & P for White washing two coats with shell lime per sqm
153Supplying all labour T & P for wall painting 2 coats with plastic emulsion paint of approved shade on old work to give an even shade including cost of paint per 1 sqm
154Supplying all labour T & P for finishing wall with Weather Coat of approved shade on new work two coat to give an even shade including cost of paint.
155Supplying all labour T & P for M.S door including making, fitting , fixing and transportation to site as per direction of Engineer-In-Charge
156Pump House Door
157Toilet Door
158Window
159Supplying all labour T & P for fitting & fixing of seramic Indian pan for toilet room inluding all cost transportation etc all complete as per direction of Engineer-In-charge.(Including all fittings)
160Supplying all labour T & P for R.C.C ring for 0.9 mtr dia including transporting ,excavation, fixing and placing in position of soakpit .
161Supplying all labour T & P for R.C.C cover plate including transporting , fixing and placing in position of soakpit .
162Supplying all labour T & P for writing information and draw a logo of BASUDHA
163Internal ElectrificationSupplying all labour T&P for Internal Electrification for pump house as per direction of Engineering In Charge.
164Recessed wiring to light point with 1.5 sqmm FR PVC insulted single core multistand copper conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 5 AMP 250 V piano type switch ISI marked and ceiling rose ISI Marked mounted on MS box having front bakelite cover of suitable size,MS box with 1.00 sqm FR PVC insulted single core multistrand copper conductor and earth wire including all accessories and connection as per direction of Engineer in charge (make of wire = finollex / L &T / Anchor / Havels / V-Guard) (deducting the cost of S/F of 100 mm x 100 mm x 60 mm MS box with bakelite cover - 1 no )
165do-…………group A (1.1.1-1.24.2)
166do-…………group B (1.1.1-1.24.2)
167do-…………group C(1.1.1-1.24.2)
168Recessed wiring to Fan point in
169do-…………group C(1.1.1-1.24.2)
170S/F of 5amp switch & socket out let of ISI marked on existing board (1.25.1 &1.25.4)
171S/F of metal box 180mm x 100mm x 60mm deep (Nominal size) in recess switch suitable size of phenolic laminated sheet in front including providing and fixing 5 pin 15/16 amp. Piano type switch connection, painting etc. as required (1.27)
172Wiring for circuit / sub-main wiring along with earth wire with following size of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire-finolex/L&T/Anchor/Havels/V-Guard)
1732 x 1.5 sqmm + 1 x 1.5 sqmm
1742 x 4 sqmm + 1 x 1.5 sqmm
175S/F of bbattan holder BK angle holder ISI marked including connection etc. instead of ceiling rose (1.29-1.28)
176Supply,installation, testing and commision of DP main switch (IS-13940 part 3/1993) on existing surface/wall mounting & complete with H.R.C. fuse links, inter connections earthing etc. as required as per direction of engnieer in-charge (Make-Simens/HPL/Anchor/L&T) 32amp. D.P. -do-
177do- 63amp. T.P.N. Main switch with bus bar
178do- 32amp. T.P.N. Main switch on the pannel board
179S/F of 'B' series SP MCB of 6 amp. Rating 240 volt 'B' series MCB for lighting and other loads in the exiting MCB Distribution board ISI marked complete with connection, tesitng and commissioning etc. as required single pole(2.6.1)
180S/F of 4 way single pole and neutral sheet MCB distribution board 250 bolt on surface / recess complete with tinned copper bus bar, neutral bar , earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required
181S/F of 16/18 SWG metal box of following sizes (Nominal size) in recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required
182150 mm x 100 mm x 60 mm deep (1.24.4)
183180 mm x 100 mm x 60 mm deep (1.24.5)
184Earthing with G.I earth pipe 3 mtrs. Long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe with charcoal and salt as required (3.4 + 3.6 )
185Supply and laying of 6 SWG G.I wire ISI marked at 0.5 mtr. Below ground level for conductor earth electrode including soldering etc. as required (3.8)
186S / F of 1200 mm A.C ceiling fan with all accessories and connections without fan regulator (Khaitan-Magnet / Anchor - XL)
187Supply. Installation, Testing and commissioning of bulkhead fittings including fixing of 8 watt CFL lamp with die cast aluminium housing and frosted glass cover (Make-Havels )
188Supply. Installation, Testing and commissioning of 2 x 27 watt energy efficient T-5 street light fitting including fixing of 24 watt T-5 Lamps-2 nos. including fixing of bracket and all accessories as per direction of engineer. (make - Bajaj/Havels)
189S/ F of electric step type fan regulator of ISI marked
190S /F of 18 watt CFL lamp
191S /F of Fan hook \\"S\\" type made of 16 mm MS Road
192S /F of 63/ 100 A kit kat type Fuse cut out on the surface of the pannel board
193S/F of Pannel Board of 3' x 4' size (made of 6mm thick m/s sheet and 25mmx25mmx6mm m/s angle with proper pointing) on the wall surface
194Compound wallSupplying all labour T&P for Construction of 80 mtr Compound wall for Pump house & OHT as per direction of Engineering In Charge.
195Supplying all labour T & P for earth work for foundation in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge per 100 cum.
196Supplying all materials, labor, T&P for filling the foundation with sand watered and rammed with all cost, conveyance and royalities as per direction of Engineer-in-charge
197Supplying all labour T & P for cement Concrete (1:3:6) with 4cm size hard granite metal per 1cum as per direction of Engineer-in-charge
198Supplying all labour T & P for R.C.C work of M-20 grade with 20mm and down grade black hard granite(crusher broken) stone chips including hoisting and laying as per direction of Engineer-in-charge
199Supplying all labour T & P for rigid and smooth centering, shuttering for R.C.C work including false works & dismantling them after casting including cost of materials complete in ground floor as per direction of Engineer-in-charge
200Foundation Below Plinth bend
201Column & Plinth Bend
202Supplying all labour T & P for random rubble H.G stone Masonry in cement mortar (1:6) in foundation and plinth per 1 cum.
203Supplying all labour T & P for fitting & fixing uncoated HYSD Bar reinforcement including cutting, bending ,binding,shifting to site including cost of material etc complete as per the direction of Engineer-In-Charge.
204Supplying all labour T & P fo brick work in super structure with bricks 23cm X 11cm X 8cm size having crushing strength not less than 75 Kg/cm² with dimensional tolerence ±8 percent in cement motar (1:6) for superstructure per 1 cum as per direction of Engineer-in-charge
205Supplying all labour T & P for 12mm thick cement plaster (1:6) on brick work per length of 50 mtr as per direction of Engineer-in-charge
206Supplying all labour T & P for White washing two coats with shell lime per sqm as per direction of Engineer-in-charge
207Supplying all labour T & P for finishing wall with Weather Coat of approved shade on new work two coat to give an even shade including cost of paint. as per direction of Engineer-in-charge
208supply labour T & P Fitting and fixing with colour washing / painting of 4 mtr length Grill gate.
209Installation of Pump and MotorSupply, installation, testing and commissioning of variable voltage star rated, ISI/BIS and ISO certified, three phase vertical submersible 3 HP pump set of working head of 68 mtr and 1.80 lps from Source to OHT (4 nos Pump sets including 100% stand-by)
210Electric driven vertical submersible pump set(SD) of 3-phase having Head of 68 mtr & Discharge 1.80 LPS, Kirloskar,KSB,LUBI make. (3 HP)
211Supplying ,installing commissionig & testing of ISI marked Motor control panel board suitable for above pump set with suitable volt meter & Ampere meter (if not in the control pannel volt meter & Ampere meter will be fitted separately).
212Supplying ,installing commissionig & testing of ISI marked 100 AMP main switch suitable for above pump set .
21325 sq. mm Armoured 4 core Aluminium cable reputed make .
2146 sq. mm copper Submersiable flat cable reputed make like .
215M.S.Angle frame with suitable nut & bolt with painting.for pannel boards.
216Double ended Flanged G.I Pipe of 50mm dia.D/F of medium quality with required nut,bolt,rubber insertion.
217Supplying all labour T&P for lowering of pump and motor into production well up to the required depth including jointing to rising main,cable jointing with required materials & cost of transportation to site etc.all complete as per direction of Engineer in charge.
21850 x 80 mm both side flanged G.I tapper of 0.40 mtr. Length..
21950 mm x 90 degree G.I Bend D/F of size ( .30 x .30 ) m
220Supplying, fabricating and fixing MS Angle Supports 50 mm × 50 mm × 6 mm, 1.0 m long, including drilling, welding, and fixing 12 SWG (2.64 mm) GI Barbed Wire over the existing 80 Meter boundary wall, including binding wire, clamps, fixing accessories
221Supply of all labour T & P, material for soil testing, supply of design, drawing, construction, errection, testing & commissioning etc of RCC elevated storage reservoir with dome using RCC M25, 2 nos. ISI marked suitable dia sluice valve , 1No of suitable dia butter fly valve & it’s RCC valve chambers as per approved drawing , supplying fitting & fixing of suitable medium grade GI pipe make confirming to IS specification of required length from percolation well to ESR & ESR to distribution main including CI/GI for in-let, out let, over flow& washing line of ESR, RCC stair case with suitable dia structural stainless with suitable dia structural stainless steel hand rail around dome & landing etc. And stainless steel ladder outside & aluminium ladder inside, lightening arrester confirming to IS specification water level indicator. (Construction of Duck Bed above the ground level for supporting of Inlet and Outlet Pipe & Clamping of all the pipe with the Column)-(60 KL ESR OF 15 MTR STAGGING)
222Raising Main & Distribution SystemSupplying of all labour T & P for Earth work excavation in trenches for DI/ HDPE pipe lines in all kinds of soils within 50 M initial lead & 1.5 M intial lift including rough dressing and breaking clods to maximum 5 cm to 7 cm & laying in layers not exceeding 0.3 m in depth etc all complete as per the direction of engineer in-charge.(160 mm HDPE pipe ,110 mm HDPE pipe ,90 mm HDPE Pipe )
223Supplying of all labour T & P for filling in foundation trenches with excavated materials as directed by the Engineer-In-Charge of earth work for cum (Ordinary Soil)
224Supplying all material labour ,T&P & laying in trenches HDPE pipes conforming to IS 4984-1995 and specials of following Out side diameter and class-1 to class-3 and jointing by fusion welding method including testingas per specification complete. and as per the direction of engineer in charge . Including all Fittings and fixing.(90 mm HDPE pipe (PN-10))
225Supplying all labour ,T&P & laying and jointing GI pipes, fittings & specials of approved make excluding earthwork in excavation & refilling of trenches & including cost of pipe as per specification,transportation,taxes, & testing of pipe etc & febrication in case of metalic pipe all complete and as per the direction of engineer in charge
226100 mm GI pipe (MEDIUM)
22780 mm GI pipe (MEDIUM)
228Supplying all material labour ,T&P & laying in trenches HDPE pipes conforming to IS 4984-1995 and specials of following Out side diameter and class-1 to class-3 and jointing by fusion welding method including testingas per specification complete. and as per the direction of engineer in charge . Including all Fittings
229110 mm HDPE Pipe (PN-6)
23090 mm HDPE Pipe (PN-6)
231Supply all labour T&P fitting and fixing of C.I sluice valves with double flanged ends in the water line for controlling purposes conforming to IS: 14846-2000 for the following rating and nominal diameters as per specifications complete of approved make with supply of all joining materials, T&P etc all complete including cost of all materials and fittings etc all complete as per direction of engineer-in-charge.
23280mm CI Sluice Valve
233100 mm CI Sluice Valve
234100 mm CI NR Valve
235Supply and fitting & fixing of CI Air Valve of approved make with supply of Jointing materials T&P etc all complete as per the direction of Engineer-In-Charge.
23615mm Air Valve
237Supply all labour T&P fitting and fixing of construction of Valve Chamber for Sluice Valve & NR Valve complete as directed by the engineer in-charge..
238Supply all labour T&P fitting and fixing of construction of Valve Chamber for Air Valve complete as directed by the engineer in-charge..
239Dismantling the C.C roads and removing including stacking the useful materials for reuse and removing the debris within 50m. Lead including all labour & T&P required for the work complete as directed by the engineer in-charge. (560 mtr x 0.41 mtr x 0.20 mtr)
240Supplying all labour T&P for cement concrete (1:2:4) with 12mm size hard granite chips per 1 cum. ( ref pg no.44, SL -7, analysis of rates) (560 mtr x 0.41 mtr x 0.20 mtr)
241Supply all labour T&P fitting,fixing and Installation of Functional Household Tap Connection from the existing ferrule point to the household Premises.
242Supply all labour T&P fitting and fixing of construction of Stand alone for Govt. Institution.(1000Ltr. Storage)
243Supply all labour T&P fitting and fixing of construction of Stand post complete as directed by the engineer in-charge.
244Supply all materials, labour, T& P and providing and fixing IEC hoarding board of size 1.00m (4') x 0.91m (3'). The hoarding frame 25mm x25mm x 3mm thick hollow square stainless stell bar supporting with 25mm x 25mm x 2mm size stainless steel bar in middle- 2 nos. covered with 1.6mm thick steel plate, fixing of IEC Message over teh board (Flex banner of 6' x 4' size) as per desing specification including 2 nos. 55mm dia stainless steel pipe of 2mm thickness support pillar including earthwork in excavation in foundation in all kids of soil, Cement concrete (1:2:4) with 12 mm size HG chips with cost. carriage, royality and taxes of all materials, welding, buffing, polishing and labour etc. all complete as per direction of Enginner in Charge.
245MAINTENANCE COST FOR 5 YEAR (5% OF TOTAL CIVIL COST) RPWS TO ZONE-I VILL:JHARIGAON (DHONODAMAL)
246MAINTENANCE COST FOR 5 YEAR (5% OF TOTAL CIVIL COST)RPWS TO ZONE-II VILL:JHARIGAON ((BALAJI SAHI) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57169780
AUTHORITY Government Departments
TENDER VALUE 1.80 Crore
LAST DATE 02-09-2026
Authority
Authority Name Rural Water Supply And Sanitation Division
Work Description Tender for Execution Of Rural Piped Water Supply Scheme To Dhonodamal In The Village Jharigaon Of G.P Jharigaon Under Jharigaon Block In Nabarangpur District Including 5 Years O&M. (New)
Basic Detail
Tender No 06/ACE/RWSS/KPT/26-27/17.08.26
Bidding Type Tender
Location
City Nabarangpur
State Odisha
Key Dates
Publish Date 24 Aug 2026
Submission Date 02 Sep 2026
Open Date 03 Sep 2026
Finance
Tender Value 1.80 Crore
Tender Fee 10000
EMD 1.80 Lakhs
Exemption Available
Document List
BOQ_607060.xls
c5517ef2-cfdf-421e-8d93-6f0c6bbdfa9b.html
DHONDAMALA.pdf
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Sep 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_607060.xls

html

c5517ef2-cfdf-421e-8d93-6f0c6bbdfa9b.html

pdf

DHONDAMALA.pdf

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders