Drinking Water Supply and Sanitation Government Departments Closing in 3 days TDR #57169779

Tender For Execution Of Rural Piped Water Supply Scheme To Lendibeda In Village Naktisemoda Of Naktisemoda G.P Under Raighar Block In Nabarangpur District Including 5 Years O&M. (New)

Issued by Government Departments · Nabarangpur, Odisha
Tender Value
3.54 Crore
Estimated cost
Bid Submission
02 Sep 2026
3 days left
EMD
3.54 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nabarangpur → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Execution Of Rural Piped Water Supply Scheme To Lendibeda In Village Naktisemoda Of Naktisemoda G.P Under Raighar Block In Nabarangpur District Including 5 Years O&M. (New)

BOQ

Name of Work:- EXECUTION OF RURAL PIPED WATER SUPPLY SCHEME TO LENDIBEDA IN VILLAGE NAKTISEMODA OF NAKTISEMODA G.P UNDER RAIGHAR BLOCK IN NABARANGPUR DISTRICT INCLUDING 5 YEARS O&M. (NEW)
Sl. No. Item Description
1RPWS TO ZONE-I VILL:DEOBHARANDI (GARANJI) :- Head WorksSupplying all labour T&P for Construction of Platrform for Production well as per direction of Engineering In Charge.
2Approach RoadSupplying all labour T&P for Construction of Approch Road of Length 10 mtr as per direction of Engineering In Charge.
3Supplying all labour T & P for earth work for foundation and plinth / pipe line in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge .
4Supplying all labour T & P for spreading or dressing of moorum & sand.
5Moorum
6Supplying all labour T & P for cement Concrete (1:2:4) with 12mm size hard granite chips per 1cum
7Supplying all labour T & P fo Rigid and smooth centering for R.C.C works including false works and dismantling them after casting including cost of materials complete in ground floor.
8Pump HouseSupplying all labour T&P for Construction of pump house near source as per direction of Engineering In Charge.
9Supplying all labour T & P for earth work for foundation in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge.
10Supplying all materials , labour T & P for filling in foundation and plinths with sand well watered and rammed including cost,carriage & royality of all materials etc. all complete & as per direction of Engineer-In-Charge
11Supplying all labour T & P materials providing C.C (1:3:6)with 40 mm CBG metal including cost,conveyance and royality of materials etc all complete& as per direction of Engineer-In-Charge
12Supplying all labour T & P materilas providing RCC work of M-20 grade with 20 mm & down grade black hard granite crusher broken stone chips including hosting & laying cost, conveyance and royalty of materials etc. all complete as per the direction of Engineer-In-Charge
13Add 10 % extra on labour rate for slope roof quantity
14Supplying all labour T & P for solid cement concrete block machine mixed and Hydraulic compressed having crushing strength not less than 75 kg / cm² in CM (1:6) in foundation and plinth per cum.
15Supplying all labour T & P for rigid and smooth centering, shuttering for R.C.C work including false works & dismantling them after casting including cost of materials complete in ground floor.
16Foundation ,Column , Plinth Bend
17Lintel
18Roof , Chhaja
19Supplying all labour T & P for fitting & fixing uncoated HYSD Bar reinforcement including cutting, bending ,binding,shifting to site including cost of material etc complete as per the direction of Engineer-In-Charge.
20Supplying all labour T & P fo brick work in super structure with bricks 23cm X 11cm X 8cm size having crushing strength not less than 75 Kg/cm² with dimensional tolerence ±8 percent in cement motar (1:6) for superstrustructure per 1 cum
21Supplying all labour T & P for 12 mm thick in cement plaster in cement mortar (1:6) for brick work
22Supplying all labour T & P for 2.5cm artificial stone flooring with cement concrete (1:2:4) including punning using 12mm size hard broken granite chips
23Supplying all labour T & P for vitrified premium grade floor tiles of (300 mm x 300 mm) having thickness 8 mm to 10 mm confirming to IS-4457
24Supplying all labour T & P for White washing two coats with shell lime per sqm
25Supplying all labour T & P for wall painting 2 coats with plastic emulsion paint of approved shade on old work to give an even shade including cost of paint per 1 sqm
26Supplying all labour T & P for finishing wall with Weather Coat of approved shade on new work two coat to give an even shade including cost of paint.
27Supplying all labour T & P for M.S door including making, fitting , fixing and transportation to site as per direction of Engineer-In-Charge
28Pump House Door
29Toilet Door
30Window
31Supplying all labour T & P for fitting & fixing of seramic Indian pan for toilet room inluding all cost transportation etc all complete as per direction of Engineer-In-charge.(Including all fittings)
32Supplying all labour T & P for R.C.C ring for 0.9 mtr dia including transporting ,excavation, fixing and placing in position of soakpit .
33Supplying all labour T & P for R.C.C cover plate including transporting , fixing and placing in position of soakpit .
34Supplying all labour T & P for writing information and draw a logo of BASUDHA
35Internal ElectrificationSupplying all labour T&P for Internal Electrification for pump house as per direction of Engineering In Charge.
36Recessed wiring to light point with 1.5 sqmm FR PVC insulted single core multistand copper conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 5 AMP 250 V piano type switch ISI marked and ceiling rose ISI Marked mounted on MS box having front bakelite cover of suitable size,MS box with 1.00 sqm FR PVC insulted single core multistrand copper conductor and earth wire including all accessories and connection as per direction of Engineer in charge (make of wire = finollex / L &T / Anchor / Havels / V-Guard) (deducting the cost of S/F of 100 mm x 100 mm x 60 mm MS box with bakelite cover - 1 no )
37do-…………group A (1.1.1-1.24.2)
38do-…………group B (1.1.1-1.24.2)
39do-…………group C(1.1.1-1.24.2)
40Recessed wiring to Fan point in
41do-…………group C(1.1.1-1.24.2)
42S/F of 5amp switch & socket out let of ISI marked on existing board (1.25.1 &1.25.4)
43S/F of metal box 180mm x 100mm x 60mm deep (Nominal size) in recess switch suitable size of phenolic laminated sheet in front including providing and fixing 5 pin 15/16 amp. Piano type switch connection, painting etc. as required (1.27)
44Wiring for circuit / sub-main wiring along with earth wire with following size of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire-finolex/L&T/Anchor/Havels/V-Guard)
452 x 1.5 sqmm + 1 x 1.5 sqmm
462 x 4 sqmm + 1 x 1.5 sqmm
47S/F of bbattan holder BK angle holder ISI marked including connection etc. instead of ceiling rose (1.29-1.28)
48Supply,installation, testing and commision of DP main switch (IS-13940 part 3/1993) on existing surface/wall mounting & complete with H.R.C. fuse links, inter connections earthing etc. as required as per direction of engnieer in-charge (Make-Simens/HPL/Anchor/L&T) 32amp. D.P. -do-
49do- 63amp. T.P.N. Main switch with bus bar
50do- 32amp. T.P.N. Main switch on the pannel board
51S/F of 'B' series SP MCB of 6 amp. Rating 240 volt 'B' series MCB for lighting and other loads in the exiting MCB Distribution board ISI marked complete with connection, tesitng and commissioning etc. as required single pole(2.6.1)
52S/F of 4 way single pole and neutral sheet MCB distribution board 250 bolt on surface / recess complete with tinned copper bus bar, neutral bar , earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required
53S/F of 16/18 SWG metal box of following sizes (Nominal size) in recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required
54150 mm x 100 mm x 60 mm deep (1.24.4)
55180 mm x 100 mm x 60 mm deep (1.24.5)
56Earthing with G.I earth pipe 3 mtrs. Long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe with charcoal and salt as required (3.4 + 3.6 )
57Supply and laying of 6 SWG G.I wire ISI marked at 0.5 mtr. Below ground level for conductor earth electrode including soldering etc. as required (3.8)
58S / F of 1200 mm A.C ceiling fan with all accessories and connections without fan regulator (Khaitan-Magnet / Anchor - XL)
59Supply. Installation, Testing and commissioning of bulkhead fittings including fixing of 8 watt CFL lamp with die cast aluminium housing and frosted glass cover (Make-Havels )
60Supply. Installation, Testing and commissioning of 2 x 27 watt energy efficient T-5 street light fitting including fixing of 24 watt T-5 Lamps-2 nos. including fixing of bracket and all accessories as per direction of engineer. (make - Bajaj/Havels)
61S/ F of electric step type fan regulator of ISI marked
62S /F of 18 watt CFL lamp
63S /F of Fan hook \\"S\\" type made of 16 mm MS Road
64S /F of 63/ 100 A kit kat type Fuse cut out on the surface of the pannel board
65S/F of Pannel Board of 3' x 4' size (made of 6mm thick m/s sheet and 25mmx25mmx6mm m/s angle with proper pointing) on the wall surface
66Compund WallSupplying all labour T&P for Construction of 80 mtr Compound wall for Pump house & OHT as per direction of Engineering In Charge.
67Supplying all labour T & P for earth work for foundation in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge per 100 cum.
68Supplying all materials, labor, T&P for filling the foundation with sand watered and rammed with all cost, conveyance and royalities as per direction of Engineer-in-charge
69Supplying all labour T & P for cement Concrete (1:3:6) with 4cm size hard granite metal per 1cum as per direction of Engineer-in-charge
70Supplying all labour T & P for R.C.C work of M-20 grade with 20mm and down grade black hard granite(crusher broken) stone chips including hoisting and laying as per direction of Engineer-in-charge
71Supplying all labour T & P for rigid and smooth centering, shuttering for R.C.C work including false works & dismantling them after casting including cost of materials complete in ground floor as per direction of Engineer-in-charge
72Foundation Below Plinth bend
73Column & Plinth Bend
74Supplying all labour T & P for random rubble H.G stone Masonry in cement mortar (1:6) in foundation and plinth per 1 cum.
75Supplying all labour T & P for fitting & fixing uncoated HYSD Bar reinforcement including cutting, bending ,binding,shifting to site including cost of material etc complete as per the direction of Engineer-In-Charge.
76Supplying all labour T & P fo brick work in super structure with bricks 23cm X 11cm X 8cm size having crushing strength not less than 75 Kg/cm² with dimensional tolerence ±8 percent in cement motar (1:6) for superstructure per 1 cum as per direction of Engineer-in-charge
77Supplying all labour T & P for 12mm thick cement plaster (1:6) on brick work per length of 50 mtr as per direction of Engineer-in-charge
78Supplying all labour T & P for White washing two coats with shell lime per sqm as per direction of Engineer-in-charge
79Supplying all labour T & P for finishing wall with Weather Coat of approved shade on new work two coat to give an even shade including cost of paint. as per direction of Engineer-in-charge
80supply labour T & P Fitting and fixing with colour washing / painting of 4 mtr length Grill gate.
81Installation of Pump and MotorSupply, installation, testing and commissioning of variable voltage star rated, ISI/BIS and ISO certified, three phase vertical submersible 3 HP pump set of working head of 68 mtr and 1.80 lps from Source to OHT (5 nos Pump sets including 100% stand-by)
82Electric driven vertical submersible pump set(SD) of 3-phase having Head of 68 mtr & Discharge 1.80 LPS, Kirloskar,KSB,LUBI make. (3 HP)
83Supplying ,installing commissionig & testing of ISI marked Motor control panel board suitable for above pump set with suitable volt meter & Ampere meter (if not in the control pannel volt meter & Ampere meter will be fitted separately).
84Supplying ,installing commissionig & testing of ISI marked 100 AMP main switch suitable for above pump set .
8525 sq. mm Armoured 4 core Aluminium cable reputed make .
866 sq. mm copper Submersiable flat cable reputed make like .
87M.S.Angle frame with suitable nut & bolt with painting.for pannel boards.
88Double ended Flanged G.I Pipe of 50mm dia.D/F of medium quality with required nut,bolt,rubber insertion.
89Supplying all labour T&P for lowering of pump and motor into production well up to the required depth including jointing to rising main,cable jointing with required materials & cost of transportation to site etc.all complete as per direction of Engineer in charge.
9050 x 80 mm both side flanged G.I tapper of 0.40 mtr. Length..
9150 mm x 90 degree G.I Bend D/F of size ( .30 x .30 ) m
92Supplying, fabricating and fixing MS Angle Supports 50 mm × 50 mm × 6 mm, 1.0 m long, including drilling, welding, and fixing 12 SWG (2.64 mm) GI Barbed Wire over the existing 80 Meter boundary wall, including binding wire, clamps, fixing accessories
93Supply of all labour T & P, material for soil testing, supply of design, drawing, construction, errection, testing & commissioning etc of RCC elevated storage reservoir with dome using RCC M25, 2 nos. ISI marked suitable dia sluice valve , 1No of suitable dia butter fly valve & it’s RCC valve chambers as per approved drawing , supplying fitting & fixing of suitable medium grade GI pipe make confirming to IS specification of required length from percolation well to ESR & ESR to distribution main including CI/GI for in-let, out let, over flow& washing line of ESR, RCC stair case with suitable dia structural stainless with suitable dia structural stainless steel hand rail around dome & landing etc. And stainless steel ladder outside & aluminium ladder inside, lightening arrester confirming to IS specification water level indicator. (Construction of Duck Bed above the ground level for supporting of Inlet and Outlet Pipe & Clamping of all the pipe with the Column)- (30 KL ESR OF 15 MTR STAGGING)
94Raising Main & Distribution SystemSupplying of all labour T & P for Earth work excavation in trenches for DI/ HDPE pipe lines in all kinds of soils within 50 M initial lead & 1.5 M intial lift including rough dressing and breaking clods to maximum 5 cm to 7 cm & laying in layers not exceeding 0.3 m in depth etc all complete as per the direction of engineer in-charge.(160 mm HDPE pipe ,110 mm HDPE pipe ,90 mm HDPE Pipe )
95Supplying of all labour T & P for filling in foundation trenches with excavated materials as directed by the Engineer-In-Charge of earth work for cum (Ordinary Soil)
96Supplying all material labour ,T&P & laying in trenches HDPE pipes conforming to IS 4984-1995 and specials of following Out side diameter and class-1 to class-3 and jointing by fusion welding method including testingas per specification complete. and as per the direction of engineer in charge . Including all Fittings and fixing.(90 mm HDPE pipe (PN-10))
97Supplying all labour ,T&P & laying and jointing GI pipes, fittings & specials of approved make excluding earthwork in excavation & refilling of trenches & including cost of pipe as per specification,transportation,taxes, & testing of pipe etc & febrication in case of metalic pipe all complete and as per the direction of engineer in charge
98100 mm GI pipe (MEDIUM)
9980 mm GI pipe (MEDIUM)
100Supplying all material labour ,T&P & laying in trenches HDPE pipes conforming to IS 4984-1995 and specials of following Out side diameter and class-1 to class-3 and jointing by fusion welding method including testingas per specification complete. and as per the direction of engineer in charge . Including all Fittings
101110 mm HDPE Pipe (PN-6)
10290 mm HDPE Pipe (PN-6)
103Supply all labour T&P fitting and fixing of C.I sluice valves with double flanged ends in the water line for controlling purposes conforming to IS: 14846-2000 for the following rating and nominal diameters as per specifications complete of approved make with supply of all joining materials, T&P etc all complete including cost of all materials and fittings etc all complete as per direction of engineer-in-charge.
10480mm CI Sluice Valve
105100 mm CI Sluice Valve
106100 mm CI NR Valve
10780 mm CI NR Valve
108Supply and fitting & fixing of CI Air Valve of approved make with supply of Jointing materials T&P etc all complete as per the direction of Engineer-In-Charge.
10925mm Air Valve
110Supply all labour T&P fitting and fixing of construction of Valve Chamber for Sluice Valve & NR Valve complete as directed by the engineer in-charge..
111Supply all labour T&P fitting and fixing of construction of Valve Chamber for Air Valve complete as directed by the engineer in-charge..
112Dismantling the C.C roads and removing including stacking the useful materials for reuse and removing the debris within 50m. Lead including all labour & T&P required for the work complete as directed by the engineer in-charge. (560 mtr x 0.41 mtr x 0.20 mtr)
113Supplying all labour T&P for cement concrete (1:2:4) with 12mm size hard granite chips per 1 cum. ( ref pg no.44, SL -7, analysis of rates) (560 mtr x 0.41 mtr x 0.20 mtr)
114Supply all labour T&P fitting,fixing and Installation of Functional Household Tap Connection from the existing ferrule point to the household Premises.
115Supply all labour T&P fitting and fixing of construction of Stand alone for Govt. Institution.(1000Ltr. Storage)
116Supply all materials, labour, T& P and providing and fixing IEC hoarding board of size 1.00m (4') x 0.91m (3'). The hoarding frame 25mm x25mm x 3mm thick hollow square stainless stell bar supporting with 25mm x 25mm x 2mm size stainless steel bar in middle- 2 nos. covered with 1.6mm thick steel plate, fixing of IEC Message over teh board (Flex banner of 6' x 4' size) as per desing specification including 2 nos. 55mm dia stainless steel pipe of 2mm thickness support pillar including earthwork in excavation in foundation in all kids of soil, Cement concrete (1:2:4) with 12 mm size HG chips with cost. carriage, royality and taxes of all materials, welding, buffing, polishing and labour etc. all complete as per direction of Enginner in Charge.
117RPWS TO ZONE-II VILL:NAKTISEMODA (KAHAKAMATA)Head WorksSupplying all labour T&P for Construction of Platrform for Production well as per direction of Engineering In Charge.
118Approach RoadSupplying all labour T&P for Construction of Approch Road of Length 10 mtr as per direction of Engineering In Charge.
119Supplying all labour T & P for earth work for foundation and plinth / pipe line in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge .
120Supplying all labour T & P for spreading or dressing of moorum & sand .
121Moorum
122Supplying all labour T & P for cement Concrete (1:2:4) with 12mm size hard granite chips per 1cum
123Supplying all labour T & P fo Rigid and smooth centering for R.C.C works including false works and dismantling them after casting including cost of materials complete in ground floor.
124Pump HouseSupplying all labour T & P for earth work for foundation in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge.
125Supplying all materials , labour T & P for filling in foundation and plinths with sand well watered and rammed including cost,carriage & royality of all materials etc. all complete & as per direction of Engineer-In-Charge
126Supplying all labour T & P materials providing C.C (1:3:6)with 40 mm CBG metal including cost,conveyance and royality of materials etc all complete& as per direction of Engineer-In-Charge
127Supplying all labour T & P materilas providing RCC work of M-20 grade with 20 mm & down grade black hard granite crusher broken stone chips including hosting & laying cost, conveyance and royalty of materials etc. all complete as per the direction of Engineer-In-Charge
128Add 10 % extra on labour rate for slope roof quantity
129Supplying all labour T & P for solid cement concrete block machine mixed and Hydraulic compressed having crushing strength not less than 75 kg / cm² in CM (1:6) in foundation and plinth per cum.
130Supplying all labour T & P for rigid and smooth centering, shuttering for R.C.C work including false works & dismantling them after casting including cost of materials complete in ground floor.
131Foundation ,Column , Plinth Bend
132Lintel
133Roof , Chhaja
134Supplying all labour T & P for fitting & fixing uncoated HYSD Bar reinforcement including cutting, bending ,binding,shifting to site including cost of material etc complete as per the direction of Engineer-In-Charge.
135Supplying all labour T & P fo brick work in super structure with bricks 23cm X 11cm X 8cm size having crushing strength not less than 75 Kg/cm² with dimensional tolerence ±8 percent in cement motar (1:6) for superstrustructure per 1 cum
136Supplying all labour T & P for 12 mm thick in cement plaster in cement mortar (1:6) for brick work
137Supplying all labour T & P for 2.5cm artificial stone flooring with cement concrete (1:2:4) including punning using 12mm size hard broken granite chips
138Supplying all labour T & P for vitrified premium grade floor tiles of (300 mm x 300 mm) having thickness 8 mm to 10 mm confirming to IS-4457
139Supplying all labour T & P for White washing two coats with shell lime per sqm
140Supplying all labour T & P for wall painting 2 coats with plastic emulsion paint of approved shade on old work to give an even shade including cost of paint per 1 sqm
141Supplying all labour T & P for finishing wall with Weather Coat of approved shade on new work two coat to give an even shade including cost of paint.
142Supplying all labour T & P for M.S door including making, fitting , fixing and transportation to site as per direction of Engineer-In-Charge
143Pump House Door
144Toilet Door
145Window
146Supplying all labour T & P for fitting & fixing of seramic Indian pan for toilet room inluding all cost transportation etc all complete as per direction of Engineer-In-charge.(Including all fittings)
147Supplying all labour T & P for R.C.C ring for 0.9 mtr dia including transporting ,excavation, fixing and placing in position of soakpit .
148Supplying all labour T & P for R.C.C cover plate including transporting , fixing and placing in position of soakpit .
149Supplying all labour T & P for writing information and draw a logo of BASUDHA
150Internal ElectrificationSupplying all labour T&P for Internal Electrification for pump house as per direction of Engineering In Charge.
151Recessed wiring to light point with 1.5 sqmm FR PVC insulted single core multistand copper conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 5 AMP 250 V piano type switch ISI marked and ceiling rose ISI Marked mounted on MS box having front bakelite cover of suitable size,MS box with 1.00 sqm FR PVC insulted single core multistrand copper conductor and earth wire including all accessories and connection as per direction of Engineer in charge (make of wire = finollex / L &T / Anchor / Havels / V-Guard) (deducting the cost of S/F of 100 mm x 100 mm x 60 mm MS box with bakelite cover - 1 no )
152do-…………group A (1.1.1-1.24.2)
153do-…………group B (1.1.1-1.24.2)
154do-…………group C(1.1.1-1.24.2)
155Recessed wiring to Fan point in
156do-…………group C(1.1.1-1.24.2)
157S/F of 5amp switch & socket out let of ISI marked on existing board (1.25.1 &1.25.4)
158S/F of metal box 180mm x 100mm x 60mm deep (Nominal size) in recess switch suitable size of phenolic laminated sheet in front including providing and fixing 5 pin 15/16 amp. Piano type switch connection, painting etc. as required (1.27)
159Wiring for circuit / sub-main wiring along with earth wire with following size of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire-finolex/L&T/Anchor/Havels/V-Guard)
1602 x 1.5 sqmm + 1 x 1.5 sqmm
1612 x 4 sqmm + 1 x 1.5 sqmm
162S/F of bbattan holder BK angle holder ISI marked including connection etc. instead of ceiling rose (1.29-1.28)
163Supply,installation, testing and commision of DP main switch (IS-13940 part 3/1993) on existing surface/wall mounting & complete with H.R.C. fuse links, inter connections earthing etc. as required as per direction of engnieer in-charge (Make-Simens/HPL/Anchor/L&T) 32amp. D.P. -do-
164do- 63amp. T.P.N. Main switch with bus bar
165do- 32amp. T.P.N. Main switch on the pannel board
166S/F of 'B' series SP MCB of 6 amp. Rating 240 volt 'B' series MCB for lighting and other loads in the exiting MCB Distribution board ISI marked complete with connection, tesitng and commissioning etc. as required single pole(2.6.1)
167S/F of 4 way single pole and neutral sheet MCB distribution board 250 bolt on surface / recess complete with tinned copper bus bar, neutral bar , earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required
168S/F of 16/18 SWG metal box of following sizes (Nominal size) in recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required
169150 mm x 100 mm x 60 mm deep (1.24.4)
170180 mm x 100 mm x 60 mm deep (1.24.5)
171Earthing with G.I earth pipe 3 mtrs. Long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe with charcoal and salt as required (3.4 + 3.6 )
172Supply and laying of 6 SWG G.I wire ISI marked at 0.5 mtr. Below ground level for conductor earth electrode including soldering etc. as required (3.8)
173S / F of 1200 mm A.C ceiling fan with all accessories and connections without fan regulator (Khaitan-Magnet / Anchor - XL)
174Supply. Installation, Testing and commissioning of bulkhead fittings including fixing of 8 watt CFL lamp with die cast aluminium housing and frosted glass cover (Make-Havels )
175Supply. Installation, Testing and commissioning of 2 x 27 watt energy efficient T-5 street light fitting including fixing of 24 watt T-5 Lamps-2 nos. including fixing of bracket and all accessories as per direction of engineer. (make - Bajaj/Havels)
176S/ F of electric step type fan regulator of ISI marked
177S /F of 18 watt CFL lamp
178S /F of Fan hook \\"S\\" type made of 16 mm MS Road
179S /F of 63/ 100 A kit kat type Fuse cut out on the surface of the pannel board
180S/F of Pannel Board of 3' x 4' size (made of 6mm thick m/s sheet and 25mmx25mmx6mm m/s angle with proper pointing) on the wall surface
181Compound wallSupplying all labour T&P for Construction of 80 mtr Compound wall for Pump house & OHT as per direction of Engineering In Charge.
182Supplying all labour T & P for earth work for foundation in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge per 100 cum.
183Supplying all materials, labor, T&P for filling the foundation with sand watered and rammed with all cost, conveyance and royalities as per direction of Engineer-in-charge
184Supplying all labour T & P for cement Concrete (1:3:6) with 4cm size hard granite metal per 1cum as per direction of Engineer-in-charge
185Supplying all labour T & P for R.C.C work of M-20 grade with 20mm and down grade black hard granite(crusher broken) stone chips including hoisting and laying as per direction of Engineer-in-charge
186Supplying all labour T & P for rigid and smooth centering, shuttering for R.C.C work including false works & dismantling them after casting including cost of materials complete in ground floor as per direction of Engineer-in-charge
187Foundation Below Plinth bend
188Column & Plinth Bend
189Supplying all labour T & P for random rubble H.G stone Masonry in cement mortar (1:6) in foundation and plinth per 1 cum.
190Supplying all labour T & P for fitting & fixing uncoated HYSD Bar reinforcement including cutting, bending ,binding,shifting to site including cost of material etc complete as per the direction of Engineer-In-Charge.
191Supplying all labour T & P fo brick work in super structure with bricks 23cm X 11cm X 8cm size having crushing strength not less than 75 Kg/cm² with dimensional tolerence ±8 percent in cement motar (1:6) for superstructure per 1 cum as per direction of Engineer-in-charge
192Supplying all labour T & P for 12mm thick cement plaster (1:6) on brick work per length of 50 mtr as per direction of Engineer-in-charge
193Supplying all labour T & P for White washing two coats with shell lime per sqm as per direction of Engineer-in-charge
194Supplying all labour T & P for finishing wall with Weather Coat of approved shade on new work two coat to give an even shade including cost of paint. as per direction of Engineer-in-charge
195supply labour T & P Fitting and fixing with colour washing / painting of 4 mtr length Grill gate.
196Installation of Pump and MotorSupply, installation, testing and commissioning of variable voltage star rated, ISI/BIS and ISO certified, three phase vertical submersible 3 HP pump set of working head of 68 mtr and 1.80 lps from Source to OHT (5 nos Pump sets including 100% stand-by)
197Electric driven vertical submersible pump set(SD) of 3-phase having Head of 68 mtr & Discharge 1.80 LPS, Kirloskar,KSB,LUBI make. (3 HP)
198Supplying ,installing commissionig & testing of ISI marked Motor control panel board suitable for above pump set with suitable volt meter & Ampere meter (if not in the control pannel volt meter & Ampere meter will be fitted separately).
199Supplying ,installing commissionig & testing of ISI marked 100 AMP main switch suitable for above pump set .
20025 sq. mm Armoured 4 core Aluminium cable reputed make .
2016 sq. mm copper Submersiable flat cable reputed make like .
202M.S.Angle frame with suitable nut & bolt with painting.for pannel boards.
203Double ended Flanged G.I Pipe of 50mm dia.D/F of medium quality with required nut,bolt,rubber insertion.
204Supplying all labour T&P for lowering of pump and motor into production well up to the required depth including jointing to rising main,cable jointing with required materials & cost of transportation to site etc.all complete as per direction of Engineer in charge.
20550 x 80 mm both side flanged G.I tapper of 0.40 mtr. Length..
20650 mm x 90 degree G.I Bend D/F of size ( .30 x .30 ) m
207Supplying, fabricating and fixing MS Angle Supports 50 mm × 50 mm × 6 mm, 1.0 m long, including drilling, welding, and fixing 12 SWG (2.64 mm) GI Barbed Wire over the existing 80 Meter boundary wall, including binding wire, clamps, fixing accessories
208Supply of all labour T & P, material for soil testing, supply of design, drawing, construction, errection, testing & commissioning etc of RCC elevated storage reservoir with dome using RCC M25, 2 nos. ISI marked suitable dia sluice valve , 1No of suitable dia butter fly valve & it’s RCC valve chambers as per approved drawing , supplying fitting & fixing of suitable medium grade GI pipe make confirming to IS specification of required length from percolation well to ESR & ESR to distribution main including CI/GI for in-let, out let, over flow& washing line of ESR, RCC stair case with suitable dia structural stainless with suitable dia structural stainless steel hand rail around dome & landing etc. And stainless steel ladder outside & aluminium ladder inside, lightening arrester confirming to IS specification water level indicator. (Construction of Duck Bed above the ground level for supporting of Inlet and Outlet Pipe & Clamping of all the pipe with the Column)-50 KL ESR OF 15 MTR STAGGING
209Raising Main & Distribution SystemSupplying of all labour T & P for Earth work excavation in trenches for DI/ HDPE pipe lines in all kinds of soils within 50 M initial lead & 1.5 M intial lift including rough dressing and breaking clods to maximum 5 cm to 7 cm & laying in layers not exceeding 0.3 m in depth etc all complete as per the direction of engineer in-charge.(160 mm HDPE pipe ,110 mm HDPE pipe ,90 mm HDPE Pipe )
210Supplying of all labour T & P for filling in foundation trenches with excavated materials as directed by the Engineer-In-Charge of earth work for cum (Ordinary Soil)
211Supplying all material labour ,T&P & laying in trenches HDPE pipes conforming to IS 4984-1995 and specials of following Out side diameter and class-1 to class-3 and jointing by fusion welding method including testingas per specification complete. and as per the direction of engineer in charge . Including all Fittings and fixing.(90 mm HDPE pipe (PN-10))
212Supplying all labour ,T&P & laying and jointing GI pipes, fittings & specials of approved make excluding earthwork in excavation & refilling of trenches & including cost of pipe as per specification,transportation,taxes, & testing of pipe etc & febrication in case of metalic pipe all complete and as per the direction of engineer in charge
213100 mm GI pipe (MEDIUM)
21480 mm GI pipe (MEDIUM)
215Supplying all material labour ,T&P & laying in trenches HDPE pipes conforming to IS 4984-1995 and specials of following Out side diameter and class-1 to class-3 and jointing by fusion welding method including testingas per specification complete. and as per the direction of engineer in charge . Including all Fittings
216110 mm HDPE Pipe (PN-6)
21790 mm HDPE Pipe (PN-6)
218Supply all labour T&P fitting and fixing of C.I sluice valves with double flanged ends in the water line for controlling purposes conforming to IS: 14846-2000 for the following rating and nominal diameters as per specifications complete of approved make with supply of all joining materials, T&P etc all complete including cost of all materials and fittings etc all complete as per direction of engineer-in-charge.
21980mm CI Sluice Valve
220100 mm CI Sluice Valve
22180 mm CI NR Valve
222Supply and fitting & fixing of CI Air Valve of approved make with supply of Jointing materials T&P etc all complete as per the direction of Engineer-In-Charge.
22315mm Air Valve
224Supply all labour T&P fitting and fixing of construction of Valve Chamber for Sluice Valve & NR Valve complete as directed by the engineer in-charge..
225Supply all labour T&P fitting and fixing of construction of Valve Chamber for Air Valve complete as directed by the engineer in-charge..
226Dismantling the C.C roads and removing including stacking the useful materials for reuse and removing the debris within 50m. Lead including all labour & T&P required for the work complete as directed by the engineer in-charge. (945 mtr x 0.41 mtr x 0.20 mtr)
227Supplying all labour T&P for cement concrete (1:2:4) with 12mm size hard granite chips per 1 cum. ( ref pg no.44, SL -7, analysis of rates) (945 mtr x 0.41 mtr x 0.20 mtr)
228Supply all labour T&P fitting,fixing and Installation of Functional Household Tap Connection from the existing ferrule point to the household Premises.
229Supply all labour T&P fitting and fixing of construction of Stand alone for Govt. Institution.(1000Ltr. Storage)
230Supply all materials, labour, T& P and providing and fixing IEC hoarding board of size 1.00m (4') x 0.91m (3'). The hoarding frame 25mm x25mm x 3mm thick hollow square stainless stell bar supporting with 25mm x 25mm x 2mm size stainless steel bar in middle- 2 nos. covered with 1.6mm thick steel plate, fixing of IEC Message over teh board (Flex banner of 6' x 4' size) as per desing specification including 2 nos. 55mm dia stainless steel pipe of 2mm thickness support pillar including earthwork in excavation in foundation in all kids of soil, Cement concrete (1:2:4) with 12 mm size HG chips with cost. carriage, royality and taxes of all materials, welding, buffing, polishing and labour etc. all complete as per direction of Enginner in Charge.
231RPWS TO ZONE-III VILL:NAKTISEMODA (KANAKAKA)Head WorksSupplying all labour T&P for Construction of Platrform for Production well as per direction of Engineering In Charge.
232Approach RoadSupplying all labour T&P for Construction of Approch Road of Length 10 mtr as per direction of Engineering In Charge.
233Supplying all labour T & P for earth work for foundation and plinth / pipe line in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge .
234Supplying all labour T & P for spreading or dressing of moorum & sand .
235Moorum
236Supplying all labour T & P for cement Concrete (1:2:4) with 12mm size hard granite chips per 1cum
237Supplying all labour T & P fo Rigid and smooth centering for R.C.C works including false works and dismantling them after casting including cost of materials complete in ground floor.
238Pump HouseSupplying all labour T & P for earth work for foundation in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge.
239Supplying all materials , labour T & P for filling in foundation and plinths with sand well watered and rammed including cost,carriage & royality of all materials etc. all complete & as per direction of Engineer-In-Charge
240Supplying all labour T & P materials providing C.C (1:3:6)with 40 mm CBG metal including cost,conveyance and royality of materials etc all complete& as per direction of Engineer-In-Charge
241Supplying all labour T & P materilas providing RCC work of M-20 grade with 20 mm & down grade black hard granite crusher broken stone chips including hosting & laying cost, conveyance and royalty of materials etc. all complete as per the direction of Engineer-In-Charge
242Add 10 % extra on labour rate for slope roof quantity
243Supplying all labour T & P for solid cement concrete block machine mixed and Hydraulic compressed having crushing strength not less than 75 kg / cm² in CM (1:6) in foundation and plinth per cum.
244Supplying all labour T & P for rigid and smooth centering, shuttering for R.C.C work including false works & dismantling them after casting including cost of materials complete in ground floor.
245Foundation ,Column , Plinth Bend
246Lintel
247Roof , Chhaja
248Supplying all labour T & P for fitting & fixing uncoated HYSD Bar reinforcement including cutting, bending ,binding,shifting to site including cost of material etc complete as per the direction of Engineer-In-Charge.
249Supplying all labour T & P fo brick work in super structure with bricks 23cm X 11cm X 8cm size having crushing strength not less than 75 Kg/cm² with dimensional tolerence ±8 percent in cement motar (1:6) for superstrustructure per 1 cum
250Supplying all labour T & P for 12 mm thick in cement plaster in cement mortar (1:6) for brick work
251Supplying all labour T & P for 2.5cm artificial stone flooring with cement concrete (1:2:4) including punning using 12mm size hard broken granite chips
252Supplying all labour T & P for vitrified premium grade floor tiles of (300 mm x 300 mm) having thickness 8 mm to 10 mm confirming to IS-4457
253Supplying all labour T & P for White washing two coats with shell lime per sqm
254Supplying all labour T & P for wall painting 2 coats with plastic emulsion paint of approved shade on old work to give an even shade including cost of paint per 1 sqm
255Supplying all labour T & P for finishing wall with Weather Coat of approved shade on new work two coat to give an even shade including cost of paint.
256Supplying all labour T & P for M.S door including making, fitting , fixing and transportation to site as per direction of Engineer-In-Charge
257Pump House Door
258Toilet Door
259Window
260Supplying all labour T & P for fitting & fixing of seramic Indian pan for toilet room inluding all cost transportation etc all complete as per direction of Engineer-In-charge.(Including all fittings)
261Supplying all labour T & P for R.C.C ring for 0.9 mtr dia including transporting ,excavation, fixing and placing in position of soakpit .
262Supplying all labour T & P for R.C.C cover plate including transporting , fixing and placing in position of soakpit .
263Supplying all labour T & P for writing information and draw a logo of BASUDHA
264Internal ElectrificationSupplying all labour T&P for Internal Electrification for pump house as per direction of Engineering In Charge.
265Recessed wiring to light point with 1.5 sqmm FR PVC insulted single core multistand copper conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 5 AMP 250 V piano type switch ISI marked and ceiling rose ISI Marked mounted on MS box having front bakelite cover of suitable size,MS box with 1.00 sqm FR PVC insulted single core multistrand copper conductor and earth wire including all accessories and connection as per direction of Engineer in charge (make of wire = finollex / L &T / Anchor / Havels / V-Guard) (deducting the cost of S/F of 100 mm x 100 mm x 60 mm MS box with bakelite cover - 1 no )
266do-…………group A (1.1.1-1.24.2)
267do-…………group B (1.1.1-1.24.2)
268do-…………group C(1.1.1-1.24.2)
269Recessed wiring to Fan point in
270do-…………group C(1.1.1-1.24.2)
271S/F of 5amp switch & socket out let of ISI marked on existing board (1.25.1 &1.25.4)
272S/F of metal box 180mm x 100mm x 60mm deep (Nominal size) in recess switch suitable size of phenolic laminated sheet in front including providing and fixing 5 pin 15/16 amp. Piano type switch connection, painting etc. as required (1.27)
273Wiring for circuit / sub-main wiring along with earth wire with following size of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire-finolex/L&T/Anchor/Havels/V-Guard)
2742 x 1.5 sqmm + 1 x 1.5 sqmm
2752 x 4 sqmm + 1 x 1.5 sqmm
276S/F of bbattan holder BK angle holder ISI marked including connection etc. instead of ceiling rose (1.29-1.28)
277Supply,installation, testing and commision of DP main switch (IS-13940 part 3/1993) on existing surface/wall mounting & complete with H.R.C. fuse links, inter connections earthing etc. as required as per direction of engnieer in-charge (Make-Simens/HPL/Anchor/L&T) 32amp. D.P. -do-
278do- 63amp. T.P.N. Main switch with bus bar
279do- 32amp. T.P.N. Main switch on the pannel board
280S/F of 'B' series SP MCB of 6 amp. Rating 240 volt 'B' series MCB for lighting and other loads in the exiting MCB Distribution board ISI marked complete with connection, tesitng and commissioning etc. as required single pole(2.6.1)
281S/F of 4 way single pole and neutral sheet MCB distribution board 250 bolt on surface / recess complete with tinned copper bus bar, neutral bar , earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required
282S/F of 16/18 SWG metal box of following sizes (Nominal size) in recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required
283150 mm x 100 mm x 60 mm deep (1.24.4)
284180 mm x 100 mm x 60 mm deep (1.24.5)
285Earthing with G.I earth pipe 3 mtrs. Long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe with charcoal and salt as required (3.4 + 3.6 )
286Supply and laying of 6 SWG G.I wire ISI marked at 0.5 mtr. Below ground level for conductor earth electrode including soldering etc. as required (3.8)
287S / F of 1200 mm A.C ceiling fan with all accessories and connections without fan regulator (Khaitan-Magnet / Anchor - XL)
288Supply. Installation, Testing and commissioning of bulkhead fittings including fixing of 8 watt CFL lamp with die cast aluminium housing and frosted glass cover (Make-Havels )
289Supply. Installation, Testing and commissioning of 2 x 27 watt energy efficient T-5 street light fitting including fixing of 24 watt T-5 Lamps-2 nos. including fixing of bracket and all accessories as per direction of engineer. (make - Bajaj/Havels)
290S/ F of electric step type fan regulator of ISI marked
291S /F of 18 watt CFL lamp
292S /F of Fan hook \\"S\\" type made of 16 mm MS Road
293S /F of 63/ 100 A kit kat type Fuse cut out on the surface of the pannel board
294S/F of Pannel Board of 3' x 4' size (made of 6mm thick m/s sheet and 25mmx25mmx6mm m/s angle with proper pointing) on the wall surface
295Compound wallSupplying all labour T&P for Construction of 80 mtr Compound wall for Pump house & OHT as per direction of Engineering In Charge.
296Supplying all labour T & P for earth work for foundation in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge per 100 cum.
297Supplying all materials, labor, T&P for filling the foundation with sand watered and rammed with all cost, conveyance and royalities as per direction of Engineer-in-charge
298Supplying all labour T & P for cement Concrete (1:3:6) with 4cm size hard granite metal per 1cum as per direction of Engineer-in-charge
299Supplying all labour T & P for R.C.C work of M-20 grade with 20mm and down grade black hard granite(crusher broken) stone chips including hoisting and laying as per direction of Engineer-in-charge
300Supplying all labour T & P for rigid and smooth centering, shuttering for R.C.C work including false works & dismantling them after casting including cost of materials complete in ground floor as per direction of Engineer-in-charge
301Foundation Below Plinth bend
302Column & Plinth Bend
303Supplying all labour T & P for random rubble H.G stone Masonry in cement mortar (1:6) in foundation and plinth per 1 cum.
304Supplying all labour T & P for fitting & fixing uncoated HYSD Bar reinforcement including cutting, bending ,binding,shifting to site including cost of material etc complete as per the direction of Engineer-In-Charge.
305Supplying all labour T & P fo brick work in super structure with bricks 23cm X 11cm X 8cm size having crushing strength not less than 75 Kg/cm² with dimensional tolerence ±8 percent in cement motar (1:6) for superstructure per 1 cum as per direction of Engineer-in-charge
306Supplying all labour T & P for 12mm thick cement plaster (1:6) on brick work per length of 50 mtr as per direction of Engineer-in-charge
307Supplying all labour T & P for White washing two coats with shell lime per sqm as per direction of Engineer-in-charge
308Supplying all labour T & P for finishing wall with Weather Coat of approved shade on new work two coat to give an even shade including cost of paint. as per direction of Engineer-in-charge
309supply labour T & P Fitting and fixing with colour washing / painting of 4 mtr length Grill gate.
310Installation of Pump and MotorSupply, installation, testing and commissioning of variable voltage star rated, ISI/BIS and ISO certified, three phase vertical submersible 3 HP pump set of working head of 68 mtr and 1.80 lps from Source to OHT (5 nos Pump sets including 100% stand-by)
311Electric driven vertical submersible pump set(SD) of 3-phase having Head of 68 mtr & Discharge 1.80 LPS, Kirloskar,KSB,LUBI make. (3 HP)
312Supplying ,installing commissionig & testing of ISI marked Motor control panel board suitable for above pump set with suitable volt meter & Ampere meter (if not in the control pannel volt meter & Ampere meter will be fitted separately).
313Supplying ,installing commissionig & testing of ISI marked 100 AMP main switch suitable for above pump set .
31425 sq. mm Armoured 4 core Aluminium cable reputed make .
3156 sq. mm copper Submersiable flat cable reputed make like .
316M.S.Angle frame with suitable nut & bolt with painting.for pannel boards.
317Double ended Flanged G.I Pipe of 50mm dia.D/F of medium quality with required nut,bolt,rubber insertion.
318Supplying all labour T&P for lowering of pump and motor into production well up to the required depth including jointing to rising main,cable jointing with required materials & cost of transportation to site etc.all complete as per direction of Engineer in charge.
31950 x 80 mm both side flanged G.I tapper of 0.40 mtr. Length..
32050 mm x 90 degree G.I Bend D/F of size ( .30 x .30 ) m
321Supplying, fabricating and fixing MS Angle Supports 50 mm × 50 mm × 6 mm, 1.0 m long, including drilling, welding, and fixing 12 SWG (2.64 mm) GI Barbed Wire over the existing 80 Meter boundary wall, including binding wire, clamps, fixing accessories
322Supply of all labour T & P, material for soil testing, supply of design, drawing, construction, errection, testing & commissioning etc of RCC elevated storage reservoir with dome using RCC M25, 2 nos. ISI marked suitable dia sluice valve , 1No of suitable dia butter fly valve & it’s RCC valve chambers as per approved drawing , supplying fitting & fixing of suitable medium grade GI pipe make confirming to IS specification of required length from percolation well to ESR & ESR to distribution main including CI/GI for in-let, out let, over flow& washing line of ESR, RCC stair case with suitable dia structural stainless with suitable dia structural stainless steel hand rail around dome & landing etc. And stainless steel ladder outside & aluminium ladder inside, lightening arrester confirming to IS specification water level indicator. (Construction of Duck Bed above the ground level for supporting of Inlet and Outlet Pipe & Clamping of all the pipe with the Column)-(30 KL ESR OF 15 MTR STAGGING)
323Raising Main & Distribution SystemSupplying of all labour T & P for Earth work excavation in trenches for DI/ HDPE pipe lines in all kinds of soils within 50 M initial lead & 1.5 M intial lift including rough dressing and breaking clods to maximum 5 cm to 7 cm & laying in layers not exceeding 0.3 m in depth etc all complete as per the direction of engineer in-charge.(160 mm HDPE pipe ,110 mm HDPE pipe ,90 mm HDPE Pipe )
324Supplying of all labour T & P for filling in foundation trenches with excavated materials as directed by the Engineer-In-Charge of earth work for cum (Ordinary Soil)
325Supplying all material labour ,T&P & laying in trenches HDPE pipes conforming to IS 4984-1995 and specials of following Out side diameter and class-1 to class-3 and jointing by fusion welding method including testingas per specification complete. and as per the direction of engineer in charge . Including all Fittings and fixing.(90 mm HDPE pipe (PN-10))
326Supplying all labour ,T&P & laying and jointing GI pipes, fittings & specials of approved make excluding earthwork in excavation & refilling of trenches & including cost of pipe as per specification,transportation,taxes, & testing of pipe etc & febrication in case of metalic pipe all complete and as per the direction of engineer in charge
327100 mm GI pipe (MEDIUM)
32880 mm GI pipe (MEDIUM)
329Supplying all material labour ,T&P & laying in trenches HDPE pipes conforming to IS 4984-1995 and specials of following Out side diameter and class-1 to class-3 and jointing by fusion welding method including testingas per specification complete. and as per the direction of engineer in charge . Including all Fittings
330110 mm HDPE Pipe (PN-6)
33190 mm HDPE Pipe (PN-6)
332Supply all labour T&P fitting and fixing of C.I sluice valves with double flanged ends in the water line for controlling purposes conforming to IS: 14846-2000 for the following rating and nominal diameters as per specifications complete of approved make with supply of all joining materials, T&P etc all complete including cost of all materials and fittings etc all complete as per direction of engineer-in-charge.
33380mm CI Sluice Valve
334100 mm CI Sluice Valve
33580 mm CI NR Valve
336Supply and fitting & fixing of CI Air Valve of approved make with supply of Jointing materials T&P etc all complete as per the direction of Engineer-In-Charge.
33715mm Air Valve
338Supply all labour T&P fitting and fixing of construction of Valve Chamber for Sluice Valve & NR Valve complete as directed by the engineer in-charge..
339Supply all labour T&P fitting and fixing of construction of Valve Chamber for Air Valve complete as directed by the engineer in-charge..
340Dismantling the C.C roads and removing including stacking the useful materials for reuse and removing the debris within 50m. Lead including all labour & T&P required for the work complete as directed by the engineer in-charge. (820 mtr x 0.41 mtr x 0.20 mtr)
341Supplying all labour T&P for cement concrete (1:2:4) with 12mm size hard granite chips per 1 cum. ( ref pg no.44, SL -7, analysis of rates) (820 mtr x 0.41 mtr x 0.20 mtr)
342Supply all labour T&P fitting,fixing and Installation of Functional Household Tap Connection from the existing ferrule point to the household Premises.
343Supply all labour T&P fitting and fixing of construction of Stand alone for Govt. Institution.(1000Ltr. Storage)
344Supply all materials, labour, T& P and providing and fixing IEC hoarding board of size 1.00m (4') x 0.91m (3'). The hoarding frame 25mm x25mm x 3mm thick hollow square stainless stell bar supporting with 25mm x 25mm x 2mm size stainless steel bar in middle- 2 nos. covered with 1.6mm thick steel plate, fixing of IEC Message over teh board (Flex banner of 6' x 4' size) as per desing specification including 2 nos. 55mm dia stainless steel pipe of 2mm thickness support pillar including earthwork in excavation in foundation in all kids of soil, Cement concrete (1:2:4) with 12 mm size HG chips with cost. carriage, royality and taxes of all materials, welding, buffing, polishing and labour etc. all complete as per direction of Enginner in Charge.
345RPWS TO ZONE-IV VILL:NAKTISEMODA (LENDIBEDA)Head WorksSupplying all labour T&P for Construction of Platrform for Production well as per direction of Engineering In Charge.
346Approach RoadSupplying all labour T&P for Construction of Approch Road of Length 10 mtr as per direction of Engineering In Charge.
347Supplying all labour T & P for earth work for foundation and plinth / pipe line in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge .
348Supplying all labour T & P for spreading or dressing of moorum & sand .
349Moorum
350Supplying all labour T & P for cement Concrete (1:2:4) with 12mm size hard granite chips per 1cum
351Supplying all labour T & P fo Rigid and smooth centering for R.C.C works including false works and dismantling them after casting including cost of materials complete in ground floor.
352Pump HouseSupplying all labour T & P for earth work for foundation in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge.
353Supplying all materials , labour T & P for filling in foundation and plinths with sand well watered and rammed including cost,carriage & royality of all materials etc. all complete & as per direction of Engineer-In-Charge
354Supplying all labour T & P materials providing C.C (1:3:6)with 40 mm CBG metal including cost,conveyance and royality of materials etc all complete& as per direction of Engineer-In-Charge
355Supplying all labour T & P materilas providing RCC work of M-20 grade with 20 mm & down grade black hard granite crusher broken stone chips including hosting & laying cost, conveyance and royalty of materials etc. all complete as per the direction of Engineer-In-Charge
356Add 10 % extra on labour rate for slope roof quantity
357Supplying all labour T & P for solid cement concrete block machine mixed and Hydraulic compressed having crushing strength not less than 75 kg / cm² in CM (1:6) in foundation and plinth per cum.
358Supplying all labour T & P for rigid and smooth centering, shuttering for R.C.C work including false works & dismantling them after casting including cost of materials complete in ground floor.
359Foundation ,Column , Plinth Bend
360Lintel
361Roof , Chhaja
362Supplying all labour T & P for fitting & fixing uncoated HYSD Bar reinforcement including cutting, bending ,binding,shifting to site including cost of material etc complete as per the direction of Engineer-In-Charge.
363Supplying all labour T & P fo brick work in super structure with bricks 23cm X 11cm X 8cm size having crushing strength not less than 75 Kg/cm² with dimensional tolerence ±8 percent in cement motar (1:6) for superstrustructure per 1 cum
364Supplying all labour T & P for 12 mm thick in cement plaster in cement mortar (1:6) for brick work
365Supplying all labour T & P for 2.5cm artificial stone flooring with cement concrete (1:2:4) including punning using 12mm size hard broken granite chips
366Supplying all labour T & P for vitrified premium grade floor tiles of (300 mm x 300 mm) having thickness 8 mm to 10 mm confirming to IS-4457
367Supplying all labour T & P for White washing two coats with shell lime per sqm
368Supplying all labour T & P for wall painting 2 coats with plastic emulsion paint of approved shade on old work to give an even shade including cost of paint per 1 sqm
369Supplying all labour T & P for finishing wall with Weather Coat of approved shade on new work two coat to give an even shade including cost of paint.
370Supplying all labour T & P for M.S door including making, fitting , fixing and transportation to site as per direction of Engineer-In-Charge
371Pump House Door
372Toilet Door
373Window
374Supplying all labour T & P for fitting & fixing of seramic Indian pan for toilet room inluding all cost transportation etc all complete as per direction of Engineer-In-charge.(Including all fittings)
375Supplying all labour T & P for R.C.C ring for 0.9 mtr dia including transporting ,excavation, fixing and placing in position of soakpit .
376Supplying all labour T & P for R.C.C cover plate including transporting , fixing and placing in position of soakpit .
377Supplying all labour T & P for writing information and draw a logo of BASUDHA
378Internal ElectrificationSupplying all labour T&P for Internal Electrification for pump house as per direction of Engineering In Charge.
379Recessed wiring to light point with 1.5 sqmm FR PVC insulted single core multistand copper conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 5 AMP 250 V piano type switch ISI marked and ceiling rose ISI Marked mounted on MS box having front bakelite cover of suitable size,MS box with 1.00 sqm FR PVC insulted single core multistrand copper conductor and earth wire including all accessories and connection as per direction of Engineer in charge (make of wire = finollex / L &T / Anchor / Havels / V-Guard) (deducting the cost of S/F of 100 mm x 100 mm x 60 mm MS box with bakelite cover - 1 no )
380do-…………group A (1.1.1-1.24.2)
381do-…………group B (1.1.1-1.24.2)
382do-…………group C(1.1.1-1.24.2)
383Recessed wiring to Fan point in
384do-…………group C(1.1.1-1.24.2)
385S/F of 5amp switch & socket out let of ISI marked on existing board (1.25.1 &1.25.4)
386S/F of metal box 180mm x 100mm x 60mm deep (Nominal size) in recess switch suitable size of phenolic laminated sheet in front including providing and fixing 5 pin 15/16 amp. Piano type switch connection, painting etc. as required (1.27)
387Wiring for circuit / sub-main wiring along with earth wire with following size of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire-finolex/L&T/Anchor/Havels/V-Guard)
3882 x 1.5 sqmm + 1 x 1.5 sqmm
3892 x 4 sqmm + 1 x 1.5 sqmm
390S/F of bbattan holder BK angle holder ISI marked including connection etc. instead of ceiling rose (1.29-1.28)
391Supply,installation, testing and commision of DP main switch (IS-13940 part 3/1993) on existing surface/wall mounting & complete with H.R.C. fuse links, inter connections earthing etc. as required as per direction of engnieer in-charge (Make-Simens/HPL/Anchor/L&T) 32amp. D.P. -do-
392do- 63amp. T.P.N. Main switch with bus bar
393do- 32amp. T.P.N. Main switch on the pannel board
394S/F of 'B' series SP MCB of 6 amp. Rating 240 volt 'B' series MCB for lighting and other loads in the exiting MCB Distribution board ISI marked complete with connection, tesitng and commissioning etc. as required single pole(2.6.1)
395S/F of 4 way single pole and neutral sheet MCB distribution board 250 bolt on surface / recess complete with tinned copper bus bar, neutral bar , earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required
396S/F of 16/18 SWG metal box of following sizes (Nominal size) in recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same case of recessed conduit as required
397150 mm x 100 mm x 60 mm deep (1.24.4)
398180 mm x 100 mm x 60 mm deep (1.24.5)
399Earthing with G.I earth pipe 3 mtrs. Long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe with charcoal and salt as required (3.4 + 3.6 )
400Supply and laying of 6 SWG G.I wire ISI marked at 0.5 mtr. Below ground level for conductor earth electrode including soldering etc. as required (3.8)
401S / F of 1200 mm A.C ceiling fan with all accessories and connections without fan regulator (Khaitan-Magnet / Anchor - XL)
402Supply. Installation, Testing and commissioning of bulkhead fittings including fixing of 8 watt CFL lamp with die cast aluminium housing and frosted glass cover (Make-Havels )
403Supply. Installation, Testing and commissioning of 2 x 27 watt energy efficient T-5 street light fitting including fixing of 24 watt T-5 Lamps-2 nos. including fixing of bracket and all accessories as per direction of engineer. (make - Bajaj/Havels)
404S/ F of electric step type fan regulator of ISI marked
405S /F of 18 watt CFL lamp
406S /F of Fan hook \\"S\\" type made of 16 mm MS Road
407S /F of 63/ 100 A kit kat type Fuse cut out on the surface of the pannel board
408S/F of Pannel Board of 3' x 4' size (made of 6mm thick m/s sheet and 25mmx25mmx6mm m/s angle with proper pointing) on the wall surface
409Compound wallSupplying all labour T&P for Construction of 80 mtr Compound wall for Pump house & OHT as per direction of Engineering In Charge.
410Supplying all labour T & P for earth work for foundation in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of Engineer-in-charge per 100 cum.
411Supplying all materials, labor, T&P for filling the foundation with sand watered and rammed with all cost, conveyance and royalities as per direction of Engineer-in-charge
412Supplying all labour T & P for cement Concrete (1:3:6) with 4cm size hard granite metal per 1cum as per direction of Engineer-in-charge
413Supplying all labour T & P for R.C.C work of M-20 grade with 20mm and down grade black hard granite(crusher broken) stone chips including hoisting and laying as per direction of Engineer-in-charge
414Supplying all labour T & P for rigid and smooth centering, shuttering for R.C.C work including false works & dismantling them after casting including cost of materials complete in ground floor as per direction of Engineer-in-charge
415Foundation Below Plinth bend
416Column & Plinth Bend
417Supplying all labour T & P for random rubble H.G stone Masonry in cement mortar (1:6) in foundation and plinth per 1 cum.
418Supplying all labour T & P for fitting & fixing uncoated HYSD Bar reinforcement including cutting, bending ,binding,shifting to site including cost of material etc complete as per the direction of Engineer-In-Charge.
419Supplying all labour T & P fo brick work in super structure with bricks 23cm X 11cm X 8cm size having crushing strength not less than 75 Kg/cm² with dimensional tolerence ±8 percent in cement motar (1:6) for superstructure per 1 cum as per direction of Engineer-in-charge
420Supplying all labour T & P for 12mm thick cement plaster (1:6) on brick work per length of 50 mtr as per direction of Engineer-in-charge
421Supplying all labour T & P for White washing two coats with shell lime per sqm as per direction of Engineer-in-charge
422Supplying all labour T & P for finishing wall with Weather Coat of approved shade on new work two coat to give an even shade including cost of paint. as per direction of Engineer-in-charge
423supply labour T & P Fitting and fixing with colour washing / painting of 4 mtr length Grill gate.
424Installation of Pump and MotorSupply, installation, testing and commissioning of variable voltage star rated, ISI/BIS and ISO certified, three phase vertical submersible 3 HP pump set of working head of 68 mtr and 1.80 lps from Source to OHT (5 nos Pump sets including 100% stand-by)
425Electric driven vertical submersible pump set(SD) of 3-phase having Head of 68 mtr & Discharge 1.80 LPS, Kirloskar,KSB,LUBI make. (3 HP)
426Supplying ,installing commissionig & testing of ISI marked Motor control panel board suitable for above pump set with suitable volt meter & Ampere meter (if not in the control pannel volt meter & Ampere meter will be fitted separately).
427Supplying ,installing commissionig & testing of ISI marked 100 AMP main switch suitable for above pump set .
42825 sq. mm Armoured 4 core Aluminium cable reputed make .
4296 sq. mm copper Submersiable flat cable reputed make like .
430M.S.Angle frame with suitable nut & bolt with painting.for pannel boards.
431Double ended Flanged G.I Pipe of 50mm dia.D/F of medium quality with required nut,bolt,rubber insertion.
432Supplying all labour T&P for lowering of pump and motor into production well up to the required depth including jointing to rising main,cable jointing with required materials & cost of transportation to site etc.all complete as per direction of Engineer in charge.
43350 x 80 mm both side flanged G.I tapper of 0.40 mtr. Length..
43450 mm x 90 degree G.I Bend D/F of size ( .30 x .30 ) m
435Supplying, fabricating and fixing MS Angle Supports 50 mm × 50 mm × 6 mm, 1.0 m long, including drilling, welding, and fixing 12 SWG (2.64 mm) GI Barbed Wire over the existing 80 Meter boundary wall, including binding wire, clamps, fixing accessories
436SUMP TO OHTElectric driven Horizontal submersible pump set(SD) of 3-phase having Head of 36 mtr & Discharge 1.58 LPS, Kirloskar, KSB, LUBI make. (5.00 HP)
437Supplying ,installing commissionig & testing of ISI marked Motor control panel board suitable for above pump set with suitable volt meter & Ampere meter (if not in the control pannel volt meter & Ampere meter will be fitted separately).
438Supplying ,installing commissionig & testing of ISI marked 100 AMP main switch suitable for above pump set .
43925 sq. mm Armoured 4 core Aluminium cable reputed make .
44010 sq. mm copper Submersiable flat cable reputed make like .
441M.S.Angle frame with suitable nut & bolt with painting.for pannel boards.
442Double ended Flanged G.I Pipe of 80 mm dia.D/F of medium quality with required nut,bolt,rubber insertion.
44350 mm x 900 G.I bend D/F of size (0.30x0.30)m
44450 x 80 mm both side flanged G.I tapper of 0.40 mtr. Length..
445Supplying all labour T&P for lowering of pump and motor into sump up to the required depth including jointing to rising main,cable jointing with required materials & cost of transportation to site etc.all complete as per direction of Engineer in charge.
446Supply of all labour T & P, material for soil testing, supply of design, drawing, construction, errection, testing & commissioning etc of RCC elevated storage reservoir with dome using RCC M25, 2 nos. ISI marked suitable dia sluice valve , 1No of suitable dia butter fly valve & it’s RCC valve chambers as per approved drawing , supplying fitting & fixing of suitable medium grade GI pipe make confirming to IS specification of required length from percolation well to ESR & ESR to distribution main including CI/GI for in-let, out let, over flow& washing line of ESR, RCC stair case with suitable dia structural stainless with suitable dia structural stainless steel hand rail around dome & landing etc. And stainless steel ladder outside & aluminium ladder inside, lightening arrester confirming to IS specification water level indicator. (Construction of Duck Bed above the ground level for supporting of Inlet and Outlet Pipe & Clamping of all the pipe with the Column)-(70 KL ESR OF 15 MTR STAGGING)
447Design, drawing, construction, errection, testing & commissioning etc of RCC On Ground reservoir OR Sump of different capacity with dome shape covering using RCC M25 grade by supplying all materials, labour, equipment T & P including testing of soil to ascertain the SBC & other parameters required for design etc fitting & fixing of suitable medium grade GI pipe make confirming to IS specification of required length CI/GI for in-let, out let, over flow& fixing of CI paddle collars on the wall of container etc all complete as per the direction of engineer-in-charge. (50KL UGR)
448Raising Main & Distribution SystemSupplying of all labour T & P for Earth work excavation in trenches for DI/ HDPE pipe lines in all kinds of soils within 50 M initial lead & 1.5 M intial lift including rough dressing and breaking clods to maximum 5 cm to 7 cm & laying in layers not exceeding 0.3 m in depth etc all complete as per the direction of engineer in-charge.(160 mm HDPE pipe ,110 mm HDPE pipe ,90 mm HDPE Pipe )
449Supplying of all labour T & P for filling in foundation trenches with excavated materials as directed by the Engineer-In-Charge of earth work for cum (Ordinary Soil)
450Supplying all material labour ,T&P & laying in trenches HDPE pipes conforming to IS 4984-1995 and specials of following Out side diameter and class-1 to class-3 and jointing by fusion welding method including testingas per specification complete. and as per the direction of engineer in charge . Including all Fittings and fixing.(90 mm HDPE pipe (PN-10))
451Supplying all labour ,T&P & laying and jointing GI pipes, fittings & specials of approved make excluding earthwork in excavation & refilling of trenches & including cost of pipe as per specification,transportation,taxes, & testing of pipe etc & febrication in case of metalic pipe all complete and as per the direction of engineer in charge
452150 mm GI pipe (MEDIUM)
453100 mm GI pipe (MEDIUM)
45480 mm GI pipe (MEDIUM)
455Supplying all material labour ,T&P & laying in trenches HDPE pipes conforming to IS 4984-1995 and specials of following Out side diameter and class-1 to class-3 and jointing by fusion welding method including testingas per specification complete. and as per the direction of engineer in charge . Including all Fittings
456160 mm HDPE Pipe (PN-6)
457110 mm HDPE Pipe (PN-6)
45890 mm HDPE Pipe (PN-6)
459Supply all labour T&P fitting and fixing of C.I sluice valves with double flanged ends in the water line for controlling purposes conforming to IS: 14846-2000 for the following rating and nominal diameters as per specifications complete of approved make with supply of all joining materials, T&P etc all complete including cost of all materials and fittings etc all complete as per direction of engineer-in-charge.
46080mm CI Sluice Valve
461100 mm CI Sluice Valve
462150 mm CI Sluice Valve
463100 mm CI NR Valve
464Supply and fitting & fixing of CI Air Valve of approved make with supply of Jointing materials T&P etc all complete as per the direction of Engineer-In-Charge.
46515mm Air Valve
466Supply all labour T&P fitting and fixing of construction of Valve Chamber for Sluice Valve & NR Valve complete as directed by the engineer in-charge..
467Supply all labour T&P fitting and fixing of construction of Valve Chamber for Air Valve complete as directed by the engineer in-charge..
468Dismantling the C.C roads and removing including stacking the useful materials for reuse and removing the debris within 50m. Lead including all labour & T&P required for the work complete as directed by the engineer in-charge. (300 mtr x 0.41 mtr x 0.20 mtr)
469Supplying all labour T&P for cement concrete (1:2:4) with 12mm size hard granite chips per 1 cum. ( ref pg no.44, SL -7, analysis of rates) (300 mtr x 0.41 mtr x 0.20 mtr)
470Supply all labour T&P fitting,fixing and Installation of Functional Household Tap Connection from the existing ferrule point to the household Premises.
471Supply all labour T&P fitting and fixing of construction of Stand alone for Govt. Institution.(1000Ltr. Storage)
472Supply all materials, labour, T& P and providing and fixing IEC hoarding board of size 1.00m (4') x 0.91m (3'). The hoarding frame 25mm x25mm x 3mm thick hollow square stainless stell bar supporting with 25mm x 25mm x 2mm size stainless steel bar in middle- 2 nos. covered with 1.6mm thick steel plate, fixing of IEC Message over teh board (Flex banner of 6' x 4' size) as per desing specification including 2 nos. 55mm dia stainless steel pipe of 2mm thickness support pillar including earthwork in excavation in foundation in all kids of soil, Cement concrete (1:2:4) with 12 mm size HG chips with cost. carriage, royality and taxes of all materials, welding, buffing, polishing and labour etc. all complete as per direction of Enginner in Charge.
473MAINTENANCE COST FOR 5 YEAR (5% OF TOTAL CIVIL COST) RPWS TO ZONE-I VILL:DEOBHARANDI (GARANJI)
474MAINTENANCE COST FOR 5 YEAR (5% OF TOTAL CIVIL COST)RPWS TO ZONE-II VILL:NAKTISEMODA (KAHAKAMATA)
475MAINTENANCE COST FOR 5 YEAR (5% OF TOTAL CIVIL COST)RPWS TO ZONE-III VILL:NAKTISEMODA (KANAKAKA)
476MAINTENANCE COST FOR 5 YEAR (5% OF TOTAL CIVIL COST)RPWS TO ZONE-IV VILL:NAKTISEMODA (LENDIBEDA) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57169779
AUTHORITY Government Departments
TENDER VALUE 3.54 Crore
LAST DATE 02-09-2026
Authority
Authority Name Rural Water Supply And Sanitation Division
Work Description Tender for Execution Of Rural Piped Water Supply Scheme To Lendibeda In Village Naktisemoda Of Naktisemoda G.P Under Raighar Block In Nabarangpur District Including 5 Years O&M. (New)
Basic Detail
Tender No 06/ACE/RWSS/KPT/26-27/17.08.26
Bidding Type Tender
Location
City Nabarangpur
State Odisha
Key Dates
Publish Date 24 Aug 2026
Submission Date 02 Sep 2026
Open Date 03 Sep 2026
Finance
Tender Value 3.54 Crore
Tender Fee 10000
EMD 3.54 Lakhs
Exemption Available
Document List
2e870276-41d1-4a1d-9331-d96f17829560.html
BOQ_607065.xls
LENDIBEDA.pdf
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Sep 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

2e870276-41d1-4a1d-9331-d96f17829560.html

xls

BOQ_607065.xls

pdf

LENDIBEDA.pdf

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders