Tender For Water Proofing To Iq Terrace , Miscellaneous Civil Repairing To Water Supply & Sanitary Fittings & Painting Works In Iq Suites At Telephone Bhawan, Sri Vijayapuram
Tender Value
3.45 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
6 days left
EMD
6920
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
South Andamans → Andaman And Nicobar Islands
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Water Proofing To Iq Terrace , Miscellaneous Civil Repairing To Water Supply & Sanitary Fittings & Painting Works In Iq Suites At Telephone Bhawan, Sri Vijayapuram
BOQ
| Sl. No. | Item Description |
| 1 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge. a)With cement mortar 1:4 (1 cement : 4 fine sand). |
| 2 | Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineerin-Charge. a)Internal Work- Exposed on wall |
| 3 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. a)Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 4 | 20 mm cement plaster of mix : a)1:4 (1 cement: 4 fine sand) |
| 5 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 6 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 7 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : a)Water thinnable cement primer. |
| 8 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. |
| 9 | One coat. |
| 10 | Two coats. |
| 11 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : a)One or more coats on old work. |
| 12 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : a)Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface. |
| 13 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
| 14 | 20 mm nominal outer dia. Pipes. |
| 15 | 25 mm nominal outer dia .Pipes. |
| 16 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 : a)15mm nominal bore |
| 17 | Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : a)White solid plastic seat with lid |
| 18 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. a)Semi rigid pipe 32 mm dia |
| 19 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. a)15 mm nominal bore with 45 cm length. |
| 20 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 21 | Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete.a)205 x 19 mm |
| 22 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. |
| 23 | Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : a)3 mm thick |
| 24 | Cleaning of toilet Fittings, wall and floor with detergent/acid to make it clean and applying grouts where ever required including cleaning of floor traps for any chokage and smooth flowing of waste water as per direction of the Engineer-in-charge |
| 25 | Providing and fixing PTMT health faucet of approved brand and manufacture.i) 15mm nominal bore |
| 26 | Collection of garbage dumped at third floor terrace and carriage of same by head load for loading in truck for disposal to municipal dumping yard by mechanical transport as per direction of the Engineer-in-charge. |
| 27 | Supplying Fosroc Nitobond SBR latex in sealed container and applying the same mixed with cement slurry in the propertion 1 part of Fosroc Notobond SBR latex : 1 part of water : 3 parts of cement by volume for creating bond between old and new concrete as per direction of the Engineer-in-charge. |
| 28 | Repair to aluminium framed glazed windows by removing from existing position, straighten the bends, make good the joints andjunctions including replacing of hinges, beading etc. if required, tightening the joints , oiling and refixing to work perfectly as per direction of Engineer in charge.(New materials, fittings to be paid separately)a)Double leaf shutter shall be considered as one job Credit for available dimantled unserviciable materials to agency (a) Old rusted MS/GI sheet, angle, flat, Tee and the like Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysSep 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender