Communications and Information Technology Government Departments Closing in 7 days TDR #57168484

Tender For Construction Of Gate House At Infopark Phase 1 C Us

Issued by Government Departments · Ernakulam, Kerala
Tender Value
38.13 Lakhs
Estimated cost
Bid Submission
07 Sep 2026
7 days left
EMD
50000
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Gate House At Infopark Phase 1 C Us

BOQ

Name of Work:- Construction of gate house at Infopark Phase 1 c us
Sl. No. Item Description
1Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared as per CPWD Specifications
2Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concert laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000 m.
3Earth work in excavation in all kinds of soil by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
4Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 as per CPWD Specifications.
5Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion): Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.
6Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering 1:4:8 (1 cement : 4 Msand : 8 graded stone aggregate 40 mm nominal size)
7Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
8Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
9Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
10Centering and shuttering including strutting, propping etc. and removal of form as per CPWD Specifications for :Foundations, footings, bases of columns, etc.
11Centering and shuttering including strutting, propping etc. and removal of form as per CPWD Specifications for :Suspended floors, roofs, landings, balconies and access platform
12Centering and shuttering including strutting, propping etc. and removal of form as per CPWD Specifications for :Lintels, beams, plinth beams, girders, bressumers and cantilevers
13Centering and shuttering including strutting, propping etc. and removal of form as per CPWD Specifications for :Columns, Pillars, Piers, Abutments, Posts and Struts
14Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level as per CPWD Specifications Thermo-Mechanically Treated bars
15Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
16Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half brick masonry.
1712 mm cement plaster of mix:1:4 (1 cement : 4 Msand) for External walls as per CPWD Specifications .Up to 10m ht
189 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
19Raised band for water cutting with CM 1:4 (1 cement : 4 Msand), 2.5cm wide, 12mm thick plain cement morter bands etc. complete as per the direction of Engineer in charge.
20Providing and laying water proofing treatment on roofs of slabs, sunshades etc.by applying cement slurry mixed with water proofing cement compound consisting of applying: a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. b) laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/ sqm and M sand @ 1.289 kg/ sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours .The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured). as per CPWD Specifications
21Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
22For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
23Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness
24Providing and fixing ISI marked oxidised M.S. handles conforming to IS : 4992 with necessary screws etc. complete: as per CPWD Specifications.100 mm
25Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. as per CPWD Specifications
26Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete:150x10 mm
27Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
28Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
29Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. (basic tile rate shall not exceed Rs 1200/m2)
30Providing and fixing brick cladding of size 9.5x2.5cm sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, for cladding over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with Grouting joints 3mm width epoxy grout with matching colur of tile etc. complete.
31Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
32Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer
33Wall painting two coats with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
34Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
35Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm after scraping and cleaning the surface including cost and conveyance of all materials, primer, labour charges, scaffolding, etc. complete as per manufacturer's specifications and as directed by Engineer-in-charge at all levels
36Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
37Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
38Providing and laying factory made chamfered edge Cement Concrete paver blocks 80 mm thick CC pave block of M30 grade with approved colour, design and pattern, in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.
39Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
40Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes
41Providing & fixing Poly carbonate corrugated sheet 2 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling / self tapping screw of size (5.5x55 mm) with EPDM seal complete upto any pitch in horizontal/ vertical/ curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size shapes where ever required.
42Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand). Light shade pigment using white cement Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57168484
AUTHORITY Government Departments
TENDER VALUE 38.13 Lakhs
LAST DATE 07-09-2026
Authority
Authority Name Infopark Smart Space Kochi
Work Description Tender for Construction Of Gate House At Infopark Phase 1 C Us
Basic Detail
Tender No Infopark/ e-Tender /012/2026-27
Bidding Type Tender
Location
City Ernakulam
State Kerala
Key Dates
Publish Date 24 Aug 2026
Submission Date 07 Sep 2026
Open Date 09 Sep 2026
Finance
Tender Value 38.13 Lakhs
Tender Fee 2950
EMD 50000
Exemption Not Available
Document List
99b94ec7-a755-4587-bb61-7055058991ba.html
Bidform.pdf
BOQ_1466809.xls
COC.pdf
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Sep 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

99b94ec7-a755-4587-bb61-7055058991ba.html

pdf

Bidform.pdf

xls

BOQ_1466809.xls

pdf

COC.pdf

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders