Water Resources and Irrigation Government Departments Closing in 2 days TDR #57167408

Tender For Project For The Construction Work Of 6 Units Of Type-3 (G+2) Residential Quarters For Junior Engineers Of The Irrigation Workshop Division In Jhansi District.

Issued by Government Departments · Jhansi, Uttar Pradesh
Tender Value
3.40 Crore
Estimated cost
Bid Submission
17 Sep 2026
2 days left
EMD
6.80 Lakhs
Bank guarantee accepted
Document Fee
6400
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jhansi → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Project For The Construction Work Of 6 Units Of Type-3 (G+2) Residential Quarters For Junior Engineers Of The Irrigation Workshop Division In Jhansi District.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 14-Sep-2026 date corrigendum Date 17-Sep-2026

BOQ

Name of Work:- Project for the construction work of 6 units of Type-3 (G+2) residential quarters for Junior Engineers of the Irrigation Workshop Division in Jhansi District.
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
2Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors.
4Making apron(with Drain & other )
5Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floorWith Chlorpyriphos/Lindane E.C. 20% with 1% concentration
6Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (Zone III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources).
7Providing and applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
8As in item No.7 above but in R.C.C. Raft foundation and footing with approved stone ballast. (Using 1:1.5:3 Mix concrete)
9R.c.c. work with cement approved coarse sand and 2 cm. (3/4\\") guage approved stone ballast in the proportion 1:1.5:3,(1cement :1.5corse sand 3 grit) in Lintel excluding supply of reinforcement and its fixing and bending but including its fixing and binding the same necessary with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works.
10As in item above for the lighter beams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete)
11As in item above but for slabs (Using 1:1.5:3 Mix concrete)
12As in item above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20.
13Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in .foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand)
14Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
15Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
16Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
17Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Second class teak wood
1819.0 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
19DOUBLE LEAF
20Providing and fixing ISI marked 35 mm flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters with one side decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick
21Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
22Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. Using R2 series with frame (70mm & above) x (40mm & above) & both glazed and fly screen sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 meter).
23Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 35 mm thick shutters With ISI marked stainless steel butt hinges of required sizeSecond class teak wood
24Mild steel or iron work of small sizes and sections such and holding down bolts, hold fast tierods, gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. 23.0 Fabrication of hold fast for door chaukhats and windows.
25Fabrication of Grill and Staircase Railling.
26Providing and fixing fly and Mosquito proof stainless steel grade 304 wire mesh gauge with 0.5 mm dia wire and 1.4 mm wire aperture
27Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :25 mm dia
28Fixing of M.S. Chaukhats26.0 Door chaukhats
29Window chaukhats up to 1.5 sqm
30Ventilator chaukhats
31Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
3215mm thick plaster with cement mortar in proportion of 1:4 cement & Coarse sand)
3312 mm cement plaster in single coat on FAIR side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 C. sand
3415 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 C. sand
3525 mm thick Cement concrete floor with cement approved coarse sand and 2cm. Graded approved stone ballast laid in planels finished with 3mm (1/8\\") floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified over and including 8 cm. (3\\") local sand and brick ballast 4 cm. gause in proportion of 1:4:8 and removing any giving then a uniform finish,including supply of all materials, labour, T&P etc. required for proper completion of the work. But without base concrete.
36Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [IN FLOORING]
37Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [IN SKIRTING]
38Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :. [IN FLOORING]
39Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. [IN SKIRTING]
40Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levelsGranite of any colour and shade Area of slab upto 0.50 sqm
41Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing he joints with white cement and matching pigment etc., complete
42Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing he joints with white cement and matching pigment etc., complete
43Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
44Two coat Wax or French polishing new wood work with approved ready made wax polish or approved French polish after rubbing down with sand paper, including supply of all material, labour and tools & plants etc required for proper completion of the work.
45Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
46Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
47Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre .
48Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
49Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes
50Providing & fixing stainless steel sliding door bolts ISI marked required colour or shade with nuts and screws etc complete.250x16 mm
51P/Fixing stainless steel tower bolts ISI marked to required colour or shade with necessary screws etc complete.250x10 mm
52Providing and fixing Stainless Steel handles ISI marked to required colour or shade with necessary screws etc complete. 150mm
53Providing and fixing stainless steel hanging floor door stopper with necessary screws etc. complete. Twin rubber stoper
54Providing and Fixing of Door slincer including necessary screws etc complete
55Providing & fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing & making curvature (wherever required) & fitting the same with necessary stainless steel nuts & bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Eng-in-charge. (weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
56Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
57Supply and filling of cinder in sunken in portion of building including breaking into required sizes including supply of all material, labour T&P required for proper completion of the work.
58Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.)
59Detailed quotation with description, specifications, entrance pergola using the specified dimensions—7.40 m length × 2.70 m width—constructing the frame with MS (Mild Steel) square hollow pipe, and roofing with polycarbonate sheet. The pricing is based on current market rates in India, specifically your region.
60Centering and shuttering including strutting, propping etc. and removal of form for :56.0 Suspended floors, roofs, landings, balconies and access platform
61Lintels, beams, plinth beams, girders, bressumers and cantilevers
62Foundations, footings, bases of columns, etc. for mass concrete
63Columns, Pillars, Piers, Abutments, Posts and Struts
64Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal sizelaid in onelayer neat cement(40 mm thick floor).
65Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality EHD – 35 Circular shape 560 mm internal dia
66Making soak pit 2.5 m diameter 3.0 m deep ith 45x45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter 1.8 m long complete as per standard design
67Construction Of Boundry Wall with 2.10 m Height above Plinth level ,3 m c/c 1:6 Brick masonry Panal and 1:1.5:3 R.C.C. column i/c 1.25 m depth of coulum & Footing from plinth Level and Providing & fixing OF Y ANGLE FRAME and concertina coil fencing with Finishing of wall with plaster ,putty and penting i/c steel work . i/c all Materials Labour T&P etc. reqired For Proper Completion Of Work as direction of Engineer -in -Charge.
68Supply and fixing M.S. Work in gate 'including all necessary for proper 'completion of the work.
69Providing and laying 80mm thick factory made inter locking C.C. paver Block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
70Construction of Roof Top Rain water harvesting for under ground water Recharging in Proposed Building
71supply and fixing of off grid roof top solar panal including batterey and invertor etc as per direction of engineer in charge for proper completion of work.
72Providing and chemical for pre-injecting constructional anti-termite treatment and creating and chemical barrier under and around the coloumn pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the external per meter of binding expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured as per I.S 6313(part 2013) IMIDACLOPRID SC 30.5 concentrate or any other approved material such as Hepthachlor of Chlordane will be used. The rate of application of chemical emulsion shall be as follows. :-Treatment for masonry and foundation 5 liters per Sq.MBack fill in immediate contact with foundation 7.5 liters per Sq.MTreatment of top surface of plinth filling 5 liters per Sq.MTreatment of soil along external per meter of Building 7.50 liters per Sq.MTreatment of soil under apron along external per meter 5 liters per Sq.M
73Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
74Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
75Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.68.0 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
762 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
772 X 4 sq. mm + 1 X 4 sq. mm earth wire
782 X 6 sq. mm + 1 X 6 sq. mm earth wire
794 X 10 sq. mm + 2 X 6 sq. mm earth wire
80Providing and fixing circular/ Hexagonal GI box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick GI sheet with its top surface hacked for proper bonding, top lid shall be screwed into the GI box by means of 3.3 mm dia round headed screws, one lock at the corners, clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
81Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
82Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 71.0 5/6 A switch
832 way 5/6 A switch
843 pin 5/6 A socket outlet
85TV antenna socket outlet
86Bell push
87Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.72.0 1 or 2 Module (75 mmX75 mm)
886 Module (200 mmX75 mm)
89Supply & fixing of single wall bracket on matching M.D.F.E.G. board base etc. complete in all required. Cat. AAA
90Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect.CAT AAA
91Supply, Installation, Testing & commissioning of mirror light 10W LED min. 350 Lumens, 1 feet or higher length as required, 6500K complete with electronic driver, lockable holders and led lamp including connection etc. as required.
92LED Down lighter (SMD Type) (System lumen efficacy ≥120 <135 lm/Watt )Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 ,UGR (Unified Glare Rating) < 19, Flicker free (flicker should 1.22 be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \\"complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminum Body including trim . 18Watt
93Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum
94Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
95Supply & erection of A.C 230/250 Volts,50 Hz exhaust fans including providing m.S bolts, mounting frame and other accessories including connections etc. complete as required 300mm sweep as per direction of E/I Make bajaj, Cromption or Equivalent.
96Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.80.0 5 to 32 Amp. Single pole
9763 Amp. Double pole
9863 Amp. Four pole
99Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.81.0 25A
100Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.82.0 4 way (4 + 12), Double door
1016 way (4 + 18), Double door
102Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). (DSR 2018 I.No. 1.56)
103Supply and fixing of power plug with 15 Amp./250 Volt flush type universal switch and 5 pin 15 A/250 V flush type universal socket switch on concealed M.S. box including supply of all material, labour T&P etc. required for proper completion of work.
104Supplying & fixing suitable size Gl box with modular plate and cover in fronton surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. (DSR 2018 I.No. 1.57)
105Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
106Supplying & Laying of 25mmx5mm G.I. Strip for earthing purpose as required complete in all respects.
107Supply & fixing of two number 8 SWG G.I. wire for earthing purpose as required complete in all respects.
108Supply, installation, testing and commissioning of electrical pane, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. The panel sheet structure shall undergo seven tank pre-treatment process before painting. The sheet steel shall be all of 2.2mm thick CRCA sheet. All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers. The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm. The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters. The minimum clearances between bus bars shall be as follows :Phase to phase - minimum 20mmPhase to neutral-minimum 15mmMain L.T. PanelIncoming : One (1) No 125A 4 pole MCCBMetering : One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch.One (1) No. (0-200A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc.One (1) Set of Phase Indication Lamp.Bus Bar : One (1) No.200 A, TPN aluminium bus bar of suitable length.Outgoing : Phase indication lamps on each outgoing to be provided.63Amps TPN - 8 NosOutgoing : 63 AMP TNP-2 NOS.OR outgoing as per site requirment
109S/F of 100 mm dia G.I pipe \\"B\\" class for cable completed with support's by 3 nos. clamp made for 20x30 mm MS flat and suitable size of nutbolt & washer required for proper completion of worh as per direction of E/I.
110Supply and laying of aluminium conducter PVC insulated armoured served sheathed cables 1100 volts grate at a depth of below ground lvl over a cusion of 75 mm thick sand alround and protected with burnt on side and on top ,On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by E/I complete in all respects,The armouring of the cable shall be properly connected with the earth conductor by clamps atc.91.0 10 Sq. mm 2core
111120 Sq. mm 3.5 core
112Supply 7 fixing of plain or pin type copper tin plated cable socket to the cable leads, insulated with tape and making connection etc. complete in all respect as per direction of E/I 92.0 10 Sq. mm
113120 Sq. mm
114Supplying, installation & testing of 7.0 m high Octagonal pole with single arm as per approved sample made from 3 mm sheet steel (Grade S 355 J0) with top diameter as 75mm and bottom dia as 130mm and base plate of 240x240x16 mm with suitable slot shaped holes for mounting the same on a shallow foundation, GI weather proof junction box with 16A SP MCB, loop-in-loop out terminals for 2nos. 4Cx16 sq.mm YWY cables and 3x2.5 sq.mm copper conductor from junction box to fitting and connected accessories as required etc. Contractor to include the cost of RCC foundation for pole as per structural detail. PWD SOR 2018 SI NO. 641
115Supply and fixing of LED Street light Fitting having die cast aluminum body and diffuser with driver set suitable for 20Watt. to 25 Watt. Confirming to IP 65 and above protection complete in all respect.. PWD SOR 2018 SI NO. 1419 CAT-AAA
116Supply and fixing of LED Street light Fitting having die cast aluminum body and diffuser with driver set suitable for 110 to 130 Watt. Confirming to IP 66 Protection complete in all respect PWD SOR 2018 SI NO. 1424
117Supply and laying of aluminum conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. PWD SOR 2018 SI No 50116 Sq mm x 4 Core PWD SOR 2018 SI No 501(i)
118Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. 16 Sq mm x 4 Core PWD SOR 2018 SI No 503 (i)
119Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respects as per direction of the Engineer incharge.16 Sq mm PWD SOR 2018 SI No 504 (d)
120Providing and fixing water closet squatting pan with 100mm sand cast iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fitting and fixtures completed including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests
121Providing & fixing white viterous china wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fitting and brackets, cutting & making good the walls wherever required . Flat back Wash Basin size 550X400 mm with single 15mm C. P. brass pillar tap
122Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 32 mm dia (for wash basin)
123Providing & fixing stainless steel AISI 304 (18/8) kitchen sink with drain board as per IS :13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets cutting and making good the walls wherever required. 510x1040 mm bowl depth 200 mm
124Providing & Fixing 600 X 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
125Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms
126Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
127Providing and fixing PTMT grating of approved quality and colour. Circular type:125 mm nominal dia with 25 mm waste hole
128Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter
129Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
130Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes.109.0 110mm dia P.V.C. pipe
13190mm dia P.V.C. pipe
132Providing & fixing UPVC Floor trap of self cleansing design with CP Jali complete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 90 mm
133Providing and fixing terminal guard. 110mm
134Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.112.0 110mm bend
13590 mm bend
136Coupler 110mm
137Coupler 90mm
138Single tee with door 90x90x90 mm
139Single tee with door 110x110x110 mm
140Providing and fixing C.P. brass Two-way angle valve for EWC points & for fixing Ablution Health Fauct of approved quality conforming to15 mm nominal bore
141Providing and fixing clean out plug 110 mm dia.
142Providing and fixing on wall face unplasticised-Rigid PVC pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 160mm dia Under floor
143Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
144Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. 117.0 Bend 87.5 degree 110 mm Bend
145Shoe (Plain) 110 mm Shoe
146Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
147Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm
148Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, punning, rounding the edges and making and finishing the outlet complete.
149\\"Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.’’121.0 Internal work-Exposed on wall 15mm dia nominal bore
150Internal work-Exposed on wall 25mm dia nominal bore
151Internal work-Exposed on wall 32mm dia nominal bore
152Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 122.0 Exposed on wall 15mm dia nominal outer dia pipes
153Exposed on wall 20mm dia nominal outer dia pipes
154Providing & fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)123.0 25 mm nominal bore
15532 mm nominal bore
156Providing and fixing ball valve (brass) of approved quality complete. (High or low pressure with plastic floats). 25 mm nominal bore
157Providing & fixing 15 mm nominal bore 45 cm long unplasticised PVC connection pipe with brass unions.
158Providing & fixing 15 mm nominal bore CP brass bib cock of approved quality conforming to IS 8931.
159Providing and fixing 15 mm nominal bore C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
160Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931.
161Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fitting and base support for tank. 18000 litres capacity
162SITC of Singal Headed Hydrant Landing Valve comprising of 80 mm dia flanged Bend 63 mm dia, with cap and chain conforming to IS:5290 (Make : Newage/Minimax/Safex/ Firex) DSR-18.9.1
163SITC of RRL Hose Pipe 63 mm dia × 15 Mtr. Long with GM Coupling conforming to IS : 636(Make - Newage/Jayshree/CRC) DSR- 18.16.1
164SITC of Short Branch Pipe as per IS:903(Make : Newage/Safex/Firex) DSR-18.18.1
165SITC of Hose Cabinet Box of 18 SWG M.S.Sheet with glass to accommodate Hose Reel Drum with Ruber Pipe with Nozzle. 2 Nos. RRL Hose and 1 No. Branch Pipe with Nozzle MR
166Providing and fixing MS Pipes conforming to IS:1239 (Medium- B class) including all fittings like anchor fasteners, brick masonry supports, couplings, bends, elbows, tees and flanges etc. welded or screwed joints as required, cutting holes and chases in brick or RCC walls and making good complete. (For Riser) MR 100mm dia
167Supply, installation, testing and commissioning of Manual Swing Type First aid Fire Hose Reel conforming to IS: 444 complete with all other necessary fixing accessories. DSR -18.17.2
168Supply of Fire Man Axe.
169\\"Providing and fixing weather proof standard Fire Duct Door complete in all respect for internal.
170SITC of Air cushion Tank (2000x1000)mm.
171SITC of Air Release Valve.
172Supply, Installation, Testing & Commissioning of NRV complete with flanges, gasket and nut bolts. DSR -16.11.2.2 150 mm
173SITC of Butterfly Valve complete with all respect. DSR-16.11.1.2 150 mm
174Supply, Installation, Testing & Commissioning of Pressure Gauge with gauge cock DSR-16.8
175Supply, Installation, Testing & Commissioning of Fire brigade inlet with 63 MM dia instantaneous inlet complete with all necessary fittings and MS enclosure with glass door made of 18/16 SWG sheet.MR 2 way
176Supply, fixing , testing & commissioning of electrical motor driven fire pump suitable for automatic operation consisting of following : (Terrace Pump) (Make : Kirloskar/Mather+Platt)(a) Horozontally mounted, split casing, Centrifugal fire pump complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 30 meter at the highest and farthest outlet at the specified flow cmplete with necessary strainers, pressure gauge including bypass arrangement for periodic testing of the working of the pumpset with required length and size of medium class GI pipe and control valves for proper completion of work. The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head. The pump shall be provided with Mechanical seals. The impeller shall be enclosed type and accurately blanced dynamically. The pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel.(b) Squirrel cage, TEFC induction motor suitable for 415 V, 3 phase having IP 55 protection and class 'B' insulation for the above pump and flexible coupling with the pump. The motor shall b rated for continuous duty and shall have HP rating necessary to drive th pump at 150% of it's rated discharge at 65% of rated head.(C) Common bed plate of fabricated mild steel channel or cast iron type.(d) Suitable cement concrete pump foundation and vibration clamping arrangement as required with foundation bolts, anti vibration pads, washers etc.(e) Pressure switch for automatic operation of motor including necessary wiring upto control panel.(f) Electrical Control panel with starter, 3 Pole motor protection category current limiting type MCCB, indicating light, ammeter, voltmeter, selector switches, CT's protective fuses, single phasing protection, dry suction cut off etc as requrd as per standard details.Discharge :450 liter per minuteHead : 35 meter
177Supply and fixing of ABC type (4 kg.) ISI Marked 1131
178Supply and fixing of CO2 gas type (4.5 kg.) ISI Marked 1132
179Supply and fixing of self glow type exit signage
180Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. DSR - 18.48 Per liters capcity.
181Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by fillin
182Supplying and stacking of good earth at site including royalty but including carriage 1km (earth measusred in stacks will be reduced by 20% for payment).
183Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 16 mm
184Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge..
185Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
186Rough dressing the trenched ground including breaking the clods.
187Fine dressing the ground
188Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and the good earth shall be paid for separately).
189Uprooting weeds from the trenched area after 10 to 15 days after flooding with water including disposal of uprooted vegetation.
190Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge With grass Turf
191Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Off Engineer -in-charge. Note- Rate to be quoted exclusive of G.S.T. which will be paid extra at the prevailing rate. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57167408
AUTHORITY Government Departments
TENDER VALUE 3.40 Crore
LAST DATE 17-09-2026
Authority
Authority Name Irrigation Department
Work Description Tender for Project For The Construction Work Of 6 Units Of Type-3 (G+2) Residential Quarters For Junior Engineers Of The Irrigation Workshop Division In Jhansi District.
Basic Detail
Tender No 04/SE/2026-27
Bidding Type Tender
Location
City Jhansi
State Uttar Pradesh
Key Dates
Publish Date 14 Sep 2026
Submission Date 17 Sep 2026
Open Date 17 Sep 2026
Finance
Tender Value 3.40 Crore
Tender Fee 6400
EMD 6.80 Lakhs
Exemption Not Available
Document List
888a89c0-b58d-4cfb-8ebb-c851df83681c.html
BOQ_2216759.xls
DocumentsLot03.pdf
Tendernotice_1 (62).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 17, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 2 days
Sep 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Sep 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

888a89c0-b58d-4cfb-8ebb-c851df83681c.html

xls

BOQ_2216759.xls

pdf

DocumentsLot03.pdf

pdf

Tendernotice_1 (62).pdf

Disclaimer