Tender For Repair And Maintenance Of Dg Sets , Cranes And Stp, Swimming Pool Including Connected Works Under Ge Golconda
Tender Value
45 Lakhs
Estimated cost
Bid Submission
15 Sep 2026
11 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of Dg Sets , Cranes And Stp, Swimming Pool Including Connected Works Under Ge Golconda
BOQ
| Sl. No. | Item Description |
| 1 | BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) File No 8155/E8 Tender Inviting Authority: GARRISON ENGINEER GOLCONDA Name of Work: REPAIR AND MAINT OF DG SETS , CRANES AND STP, SWIMMING POOL INCLUDING CONNECTED WORKS UNDER GE GOLCONDA Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of work Item Code / Make No or Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder including all TaxesRs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc. Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | Carrying out of `B' check as specified by respective manufactures of existing DG set including replacement of `B' check kit, filters, such as oil fitters, by pass filter, fuel filter, lubricant oil filter, air filter and rubber gasket for filters complete with `O' rings including testing for 250 KVA DG SET complete all as specified and as directed.Note : Engine oil, required for `B' check shall be measured and paid separately under relevant items of this schedule. |
| 3 | All as per item No.1 above but 200 KVA DG SET |
| 4 | All as per item No.1 above but 160 KVA DG SET |
| 5 | All as per item No.1 above but 125 KVA DG SET |
| 6 | All as per item No.1 above but 100 KVA DG SET |
| 7 | All as per item No.1 above but 82.5 KVA DG SET |
| 8 | All as per item No.1 above but 40 KVA DG SET |
| 9 | All as per item No.1 above but 35 KVA DG SET |
| 10 | All as per item No.1 above but 30 KVA DG SET |
| 11 | All as per item No.1 above but 25 KVA DG SET |
| 12 | All as per item No.1 above but 15 KVA DG SET |
| 13 | Replacement of existing unserviceable automatic voltage regulator with new one for the alternator of DG Set suitable for 250 KVA as that of existing make and model complete all as specified and as directed. |
| 14 | All as per item No.12 above but 200 KVA DG SET |
| 15 | All as per item No.12 above but 160 KVA DG SET |
| 16 | All as per item No.12 above but 125 KVA DG SET |
| 17 | All as per item No.12 above but 100 KVA DG SET |
| 18 | All as per item No.12 above but 82.5 KVA DG SET |
| 19 | All as per item No.12 above but 40 KVA DG SET |
| 20 | All as per item No.12 above but 15 to 35 KVA DG SET |
| 21 | Disconnecting all electrical cable connections from the dynamo assembly and taking down the dynamo assembly for carrying out repairs and complete overhauling the system including replacing the unserviceable parts like carbon brushes, bearings armature, burnt out coils etc. reassembling and re-fixing the dynamo assembly to its original position and reconnect all disconnected cable connections including testing complete for 250 KVA capacity DG set complete all as specified and as directed. |
| 22 | All as per item No.20 above but 200 KVA DG SET |
| 23 | All as per item No.20 above but 160 KVA DG SET |
| 24 | All as per item No.20 above but 100 KVA DG SET |
| 25 | All as per item No.20 above but 82.5 KVA DG SET |
| 26 | All as per item No.20 above but 40 KVA DG SET |
| 27 | All as per item No.20 above but 15 to 35 KVA DG SET |
| 28 | Disconnecting all electrical connections from the self starter assembly of existing make and model and various capacity 24 volts, 180 AH and taking down the self starter for carrying out repairs and complete overhauling the system including replacing the unserviceable parts like carbon brushes, bearings armature , burnt out coils etc. reassembling and refixing the self starter to its original position and reconnect the 250 KVA DG Set capacity complete all as specified and as directed. |
| 29 | All as per item No.27 above but 200 KVA DG SET |
| 30 | All as per item No.27 above but 160 KVA DG SET |
| 31 | All as per item No.27 above but 100 KVA DG SET |
| 32 | All as per item No.27 above but 82.5 KVA DG SET |
| 33 | All as per item No.27 above but 40 KVA DG SET |
| 34 | All as per item No.27 above but 15 to 35 KVA DG SET |
| 35 | Drain out the old used engine oil from the sump and cleaning the sump including supply and filling the same with new engine oil (20W -40 or 15W - 40) up to the required level complete all as specified and as directed. |
| 36 | S&F change over switch of 63 Amps with sheet steel enclosure 4 pole 415Volts, On load type with side handle type complete after disconnecting and reconnecting of incoming and out going connections with necessary nuts, bolts washers and lugs including taking down of old unserviceable change over switch complete all as specified and as directed.Make- HPL/Standard/Havells / L&T / GEC |
| 37 | All as per item No.35 here in before but 100 Amps. |
| 38 | All as per item No.35 here in before but 200 Amps. |
| 39 | All as per item No.35 here in before but 300/ 320 Amps. |
| 40 | Disconnecting and dismantling the fuel injection pump of any make and model for 250 KVA DG Set capacities duly isolating the fuel lines, opening and checking the pump, examining the delivery of fuel through fuel lines including replacing of pump repair kit and serviceability of FIP, complete servicing and calibrations and testing complete all as specified and as directed. |
| 41 | All as per item No.39 above but 200 KVA DG SET |
| 42 | All as per item No.39 above but 160 KVA DG SET |
| 43 | All as per item No.39 above but 100 KVA DG SET |
| 44 | Supply and filling in replacement of pre mixed coolant Ethylene Glycol based coolant (Complete EG)/DCA-2 suitable of DG sets of any Capacities complete all as specified and as directed. |
| 45 | Supply and fill Distilled water for batteries complete all as specified and as directed. |
| 46 | M & L for MCCB 3 pole, 415 Volts, adjustable type, 100 Amps with breaking capacity 16 KA complete with all connected accessories including taking out old unserviceable one all as specified and directed by Engr-in-charge. Make- Havells/Standard/L&T. |
| 47 | All as per Item No.45 above but 125 Amps 16 KA. |
| 48 | All as per Item No.45 above but 160 Amps 36 KA. |
| 49 | M & L for MCCB 4 pole, 415 Volts, adjustable type, 160 Amps with breaking capacity 36 KA complete with all connected accessories including taking out old unserviceable one complete all as specified and as directed. Make- Havells/Standard/L&T. |
| 50 | All as per Item No.48 above but 200 Amps 36 KA |
| 51 | All as per Item No.48 above but 250 Amps 36 KA |
| 52 | All as per Item No.48 above but 400 Amps 36 KA |
| 53 | M & L earth continuity conductor GI of 32x6 mm of GI strip fixed by means of bolts, nuts, check nuts and GI washers complete all as specified and directed. |
| 54 | M & L Synthetic insulating mat (rubber matting), ISI Marked suitable for 11kv electrical grade 2m X 1m X 2.5mm thick chequered top, ISI marked to be laid in front of LT panel board complete all as specified and directed. |
| 55 | Supply and replace existing unserviceable Digital Ammeter including suitable CTs as that of existing range complete all as specified and as directed. |
| 56 | Supply and replace existing unserviceable Digital Voltmeter 96 x 96 mm as that of existing range complete all as specified and as directed. |
| 57 | Supply and replace existing unserviceable selector switch for voltmeter complete all as specified and as directed. |
| 58 | Supply and replace existing unserviceable selector switch for Ammeter complete all as specified and as directed. |
| 59 | Supply and replace existing unserviceable indicating lamp LED type suitable to operate on 230 volts AC Supply of R/Y/B colour as per site requirement complete all as specified and as directed. |
| 60 | M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and moorum filling including excavation for laying of cable/pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc., required to match with the existing surface complete all as specified and directed. |
| 61 | Supply & Replacement of on load change over switch of capacity 100A front operated 415 Volts, 50Hz conforms to IS 13947-3 complete all as specified and as directed. |
| 62 | All as per Item No.60 above but for 160A capacity complete all as specified and as directed. |
| 63 | All as per Item No.60 above but for 250A capacity complete all as specified and as directed. |
| 64 | All as per Item No.60 above but for 320A capacity complete all as specified and as directed. |
| 65 | M & L Galvanised iron tubing 100 mm dia light grade laid in trenches/floors/walls for earth lead protection and cables at road crossing etc. complete including taking out rusted unserviceable one complete all as specified and as directed. |
| 66 | All as per item No.64 above but 80mm GI pipe light grade. |
| 67 | All as per item No.64 above but 50mm GI pipe light grade. |
| 68 | Supply and Laying or fixing or passing through pipe, 1100 Volts heavy duty cable, with XLPE insulated, aluminium conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed including connecting testing and commissioning complete with necessary lugs nuts, bolts, washers and glands all as specified and directed for 240 Sqmm 3.5 Core complete all as specified and as directed. |
| 69 | All as per item No.67 above but 185 Sqmm 3.5 Core |
| 70 | All as per item No.67 above but 150 Sqmm 3.5 Core |
| 71 | All as per item No.67 above but 120 Sqmm 3.5 Core |
| 72 | All as per item No.67 above but 95 Sqmm 3.5 Core |
| 73 | All as per item No.67 above but 50 Sqmm 3.5 Core |
| 74 | All as per item No.67 above but 35 Sqmm 3.5 Core |
| 75 | Disconnecting all the incoming and outgoing rubber hoses and draining out the water from the choked radiator assembly of the existing make and model and various capacities of DG sets of above 100KVA to 250KVA and taking down the radiator assembly by unscrewing all mechanical connections from the existing mounting, transporting the same to civil workshop for carrying out servicing, opening the top and bottom covers of radiator assembly cleaning thoroughly the chocked pipe of the radiator by using detergent, lime caustic soda, cotton etc., cleaning of all the deposited sediments in the pipes/tubes including arresting of leakage by means of soldering, brazing and transporting back to site and refixing the same in its original position with suitable size nuts, bolts and washers etc., complete all as specified and directed. |
| 76 | Disconnecting all the incoming and outgoing rubber hoses and draining out the water from the choked radiator assembly of the existing make and model and various capacities of DG sets of up to 100KVA and taking down the radiator assembly by unscrewing all mechanical connections from the existing mounting, transporting the same to civil workshop for carrying out servicing, opening the top and bottom covers of radiator assembly cleaning thoroughly the chocked pipe of the radiator by using detergent, lime caustic soda, cotton etc., cleaning of all the deposited sediments in the pipes/tubes including arresting of leakage by means of soldering, brazing and transporting back to site and refixing the same in its original position with suitable size nuts, bolts and washers etc., complete all as specified and directed. |
| 77 | Disconnecting defective exciter from the alternator of 250 KVA DG Set and taking out burnt out exciter to the work site for rewinding as per the existing gauge and size and refixing the same after duly repaired in alternator and testing complete all as specified and directed. Note : The rate quoted includes complete rewinding and necessary repairs. |
| 78 | Disconnecting defective exciter from the alternator of 200 KVA DG Set and taking out burnt out exciter to the work site for rewinding as per the existing gauge and size and refixing the same after duly repaired in alternator and testing complete all as specified and directed. Note : The rate quoted includes complete rewinding and necessary repairs. |
| 79 | M&L for Repair & cleaning thoroughly MILD Steel MS Industrial Boiler Smoke distribution chimney of any height and any description (Maximum 15to 20 Mtr long) with necessary cleaning agent including scrapping of old corroded paint dirt/ rust carefully and applying two coats aluminium paint including colour washing of Chimney complete all as specified and as directed. |
| 80 | M&L for Repair & Servicing of INCINERATOR Capacity(10 KG /Hrs) including Motor,Oil Fire injector, Tank Cleaning and Boiler complete all as specified and as directed. |
| 81 | Drain out the fuel from the fuel tank of DG set of capacity up to 600 Ltrs and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt / sediment, leak testing the tank and welding / brazing including refixing the tank in its original position, replacing the drain plug and PVC pipe, calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements complete all as specified and directed. |
| 82 | All as per item No.80 but of fuel tank capacity above 600 ltrs to 1000 ltrs complete all as specified and as directed. |
| 83 | Supply and replace of unserviceable Radiator Rubber Hose pipes up to 1.5 Mtr length complete all as specified and as directed. |
| 84 | Supply and replace hose clamps of DG set complete all as specified and as directed. |
| 85 | Replacement of existing unserviceable Engine Top Overhauling kit, thermostat housing, oil pressure gauge, oil pressure pipe, Amp meter, Volt meter, Frequency meter, door hinge, diesel flexible hoses, fan belt, oil filling cup, ball valve, diesel pipe clamps, radiator hose etc. with new one including servicing of FIP, Radiator, Cyl Head, Self Motor, CH Dynamo and welding of Silencer pipe including Nozzle Calibration for the DG Set suitable for 25 KVA as that of existing make and model complete all as specified and as directed. |
| 86 | Alignment of HOT crane Tracks an both sides including gas cutting and welding and grinding for smooth functioning of crane travel complete all as specified and directed. |
| 87 | Taking down and overhauling of chain pulley block of capacity 2 Ton cross travel unit of HOT crane by applying suitable oils and greases wherever required and applying cadmium compound to wire ropes including supplying and replacing unserviceable bolts and nuts complete all as specified and as directed. |
| 88 | Material & labour for painting all parts of HOT cranes with one coat of synthetic enamel paint including filling cavities enamel paint including letter and figures complete all as specified and as directed. |
| 89 | Dismantling of 5 HP capacity motor from HOT crane taking down and carry to work shop for rewinding and bringing back and refixing on crane with proper alignment with gear boxes etc. complete all as specified and as directed. |
| 90 | Earthing complete with galvanised steel earth plate electrode of size 60cm X 60cm X 6.3mm buried directly in ground (earth pit not less than 2.25 metres deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected to GI earth strip 32mm x 6 mm by means of GI bolts, nuts, check nuts and washers and earth strip protected by 40 mm dia GI pipe medium grade and connected to main distribution board/earthing test point all as shown on electrical plate No.3 of SSR Part I and all as specified including testing on completion. Notes: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 mix, Cement Earth pit and pit cover, GI funnel with watering pipe, wire mesh, protection pipe for earth lead up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II and also refer Plate No-03. Earth strip and protection pipe beyond 7.5m shall be measured and paid separately complete all as specified and as directed. Note :- Earthing will be redone if desired earth result not found during testing of the same at site. |
| 91 | Excavation in trenches not exc 1.5 mtr wide and n.exc 1.5 mtr in deep and getting out in Hard/Dense soil laying of cables etc complete all as specified and as directed. |
| 92 | Returning filling in including spreading, levelling watering and well ramming in layers n.exc 25cm thick using excavated soil complete all as specified and directed |
| 93 | Removing excavated surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5mtr above from the starting point complete all as specified and as directed. |
| 94 | M&L brick protection with common burnt bricks sub class ‘B’ of size 230 x 113 x 75mm for cable protection complete all as specified and directed. |
| 95 | Supply and spreading river sand/m sand in trenches for cables cushioning on top and bottom of cables complete all as specified and directed |
| 96 | M&L for Cleaning of BAR screen chamber, oil and grease trap , holding tank tube settler complete FRP /steel package tank complete all as specified and directed |
| 97 | M&L for Replacement of tube settler 20 Nos complete all as specified and directed |
| 98 | M&L paint of one coat of primer and two coats of synthetic enamel paint for various STP plant like pumps, motors, pipe lines of any size, MS covers , Fencing and gate etc. complete all as specified and as directed. |
| 99 | M&L for servicing of main roller shaft and chain coupling and replace of bearing 6307 SKF (4 Nos) complete all as specified and directed. |
| 100 | M&L for taking out the unserviceable cast iron Butter fly valve for size 80 mm bore, supply and fixing Butter fly valve for size 80 mm bore including jointing materials, nuts, bolts and gasket complete all as specified and directed. |
| 101 | M&L for repair of mud pump 2/3 hp electric motor including rewinding varnishing and replacing of both bearing with alteration at site including taking to the work shop and bring back and refixing complete all as specified and directed |
| 102 | M&L for taking down electric motor 1.5 HP capacity carrying out workshop in repair complete rewinding and change of bearing and back cover of NRV complete all as specified and directed .the following item change complete all as specified and as directed. 1) Impeller -01 2) Bearing -02 3) Mechanical seal -01 4) NRV -01 5) Rewinding complete -01 |
| 103 | Cleaning of main collection sewage well (Over all size of Sump 4.80 x 2.5 x 4.50 Mtr) of STP plant by taking out all sludge in liquid/ semi liquid /hardened stage as per actual site condition by sewerage extraction pumps of suitable capacity /appropriate mechanical means, removing and depositing in a pit, sprinkling of bleaching powder and covering with earth to a depth not less than 30 cm after complete setting of sludge content/rubbish/debris including necessary excavation and earthwork to a distance complete all as specified and as directed. Note: Contractor shall ensure that proper hygienic condition is maintained during operation of this item to avoid any health hazards. |
| 104 | Supply and fixing in replacement of Battery of capacity 12 Volts, 180 AH capacity complete all as specified and as directed. Make: Exide/Farukawa or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 105 | Supply and fixing in replacement of Battery of capacity 12 Volts, 150 AH capacity complete all as specified and as directed. Make: Exide/Farukawa or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 106 | Supply & Fix in repairs control wiring of LT AMF panel including CTs to Ammeter, Selector switches and Push buttons with 1.5 Sqmm copper wiring including carrying out following repairs:-(a) replacement of unserviceable CRCA sheet doors of 3.15mm on front side and backside including nuts,bolts, hinges, welding wherever necessary.(b) Painting the entire LT panel of any size with spray paint.(c) Removing the LT cables from the LT Panel board and from ground, removing the Panel from foundation and increase the height of PCC foundation by 30cm and reconnecting the cables of panel and restore the supply complete all as specified and directed. |
| 107 | S&F MIDI AMF VMR 3P Panel (Model PR-07)Controller 200 KVA, 1.5 sq. mm Copper wiring, Testing and including all service charges . |
| 108 | Servicing, overhauling of centrifugal pump, monoblock motor pump set of capacity 30 HP, 3 phase induction motor including carrying out maintenance check along including transportation with following repairs complete all as specified and as directed.:(a) Dismantling of monoblock motor pump set in presence of MES representative and display all the parts without damage any portion for inspection of Engineer in Charge to ascertain the serviceability of existing parts.(b) Heating, varnishing to stator, rotor with super quality varnish and drying out properly with external heat.(c) Cleaning, washing of bearing and use right quantity of ball bearing grease for bearing.(d) Checking play of impeller and bushing of pump.(e) Assembling of motor with old serviceable parts and replacement of unserviceable parts with new as ordered where necessary. (f) Installation of motor by making connections as per existing and testing on load. |
| 109 | All as per item No. 107 above but for centrifugal pump, monoblock motor pump set of capacity 12.5 HP complete all as specified and as directed. |
| 110 | Supply only the following items to incorporate against centrifugal monoblock motor pump set of capacity varying from 12.5 HP as required at site complete all as specified and directed:-Cast iron impeller |
| 111 | All as per item No.109 above but Ball/Thrust bearing suitable for different motor capacity as per existing. |
| 112 | All as per item No.109 above but Gland cup gun metal heavy duty. |
| 113 | All as per item No.109 above but Neck ring bush |
| 114 | All as per item No.109 above but Body bush |
| 115 | All as per item No.109 above but Thrust plate |
| 116 | Supply only the following items to incorporate against centrifugal monoblock motor pump set of capacity varying from 30 HP as required at site complete all as specified and directed:-Cast iron impeller |
| 117 | All as per item No.115 above but Ball/Thrust bearing suitable for different motor capacity as per existing. |
| 118 | All as per item No.115 above but Gland cup gun metal heavy duty. |
| 119 | All as per item No.115 above but Neck ring bush |
| 120 | All as per item No.115 above but Body bush |
| 121 | All as per item No.115 above but Thrust plate |
| 122 | Supply and fixing new CI sluice valves PN 1.6 confirming to ISI with flanged ends, SS spindle, round wheel including jointing materials,PCC work, nuts, bolts and gasket including taking out the unserviceable cast iron sluice valve for size 80 mm bore complete all as specified and directed MAKE : DURGA/KIRLOSKER/LEADER |
| 123 | (a) All as per item no.121 above but 100mm bore |
| 124 | (b) All as per item no.121 above but 150mm bore |
| 125 | (c) All as per item no.121 above but 200mm bore |
| 126 | S & F panel mounting type battery charger with transformer diode operated, 24/12Volts, 10 Amps, input range 170V to 270V including taking down old unserviceable one complete all as specified and as directed.Make: NHP/ELAK or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 127 | S & F in Repair ,Door lock of any capacity of DG Sets as suitable for existing one complete all as specified and as directed. |
| 128 | M & L PCC Base/using MS angel, channel, nut,bolt,washer etc. suitable for Pump set any Capacity up to 40 HP as suitable for existing one complete all as specified and as directed. |
| 129 | S&F radiator fan plastic material for DG Set including taking out old unserviceable one complete all as specified and as directed. |
| 130 | S&F 24 volts Starter Motor Assembly for DG sets including taking out old unserviceable one complete all as specified and as directed. |
| 131 | M&L for Renewal/replacement of 'V' belts for 100KVA to 1010KVA capacity DG sets as per existing size and model complete all as directed and specified. Make: FENNER/ DUNLOP or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 132 | M&L for Renewal/replacement of fan belts for 100KVA to 1010KVA capacity DG sets as per existing size and model complete all as directed and specified. Make: FENNER/ DUNLOP or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 133 | M&L for Renewal/replacement of Dynamo belts for 100KVA to 1010KVA capacity DG sets as per existing size and model complete all as directed and specified. |
| 134 | S&F fuel feed pump for DG including taking out old unserviceable one complete all as specified and as directed. |
| 135 | S&F oil pressure transducer suitable up to 250 KVA DG set including taking out old unserviceable one complete all as specified and as directed. |
| 136 | S&F battery terminal cable of size 50 Sqmm single core, multi stranded copper conductor including taking out old unserviceable one complete all as specified and as directed. |
| 137 | S&F brass/ copper lugs, open type, heavy duty, suitable for 50 Sqmm cable including taking out old unserviceable one complete all as specified and as directed. |
| 138 | S&F brass/ copper battery terminal, heavy duty, suitable for 180 AH, 12/24 Volts lead acid battery including taking out old unserviceable one complete all as specified and as directed. |
| 139 | S&F Stop solenoid 12 Volts for DG Set including taking out old unserviceable one complete all as specified and as directed. |
| 140 | S&F Stop solenoid 24 Volts for DG Set including taking out old unserviceable one complete all as specified and as directed. |
| 141 | S&F digital panel meter, multi function having the parameters of voltage, current, frequency, power factor, operated in 3 phase 415 volts AC with CTs including taking out old unserviceable one complete all as specified and as directed. Make: L&T/C&S or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 142 | M&L in repair Exhaust pipe of DG set of any capacity by unscrewing nuts and bolts and taking down the pipe with muffler removing the burnt out asbestos rope and well wrapping with new aluminium metal cladding with glass wool including cleaning the silencer, and fixing the same in its original position including taking down old unserviceable one complete all as specified and directed |
| 143 | Supply & Replacement of relays 24/12 volts for AMF panels complete all as specified and as directed. MAKE: L&T/SIEMENS/INDO ASIAN |
| 144 | Supply & Replacement of relays 12/12 volts for AMF panels complete all as specified and as directed. MAKE:L&T/SIEMENS/INDO ASIAN |
| 145 | Supply & Replacement of relays auxiliary contactors with logic units complete all as specified and as directed. MAKE:L&T/SIEMENS/HAVELLS |
| 146 | Supply & Replacement of Single phase preventer as per existing one complete all as specified and as directed. Make: Minilec/GIC or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 147 | Supply & Replacement of PLC based AMF relay unit as per existing one. Make: L&T or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 148 | ML for removing and shifting Fresh Water Pump up to 250 KVA DG to Workshop for repairs and calibration by replacement of necessary spare parts and reconditioning. refixing back in its original position and testing complete all as specified and as directed |
| 149 | ML for disconnecting all connections & removing the PT pump from engine 100 KVA to 250 KVA DG set and transporting to OEM authorised service centre and calibration of PT pump for maximum efficiency by replacement of PT Pump kit, gear gasket etc., refixing and connecting back in its original position and testing complete all as specified and as directed |
| 150 | Supply & Replacement of Barrel and Plunger for DG set of capacity 200 KVA to 750 KVA as per existing make and model complete all as specified and as directed. |
| 151 | Supply & Replacement of FIP bearing for DG set of capacity 100 KVA to 250 KVA as per existing make and model complete all as specified and as directed. |
| 152 | S&F self starter motor, 24 volts of make LUCAS or its equivalent approved by OEM suitable for DG set of capacity 200 KVA to 250 KVA including connecting electrically/mechanically as per recommendations of OEM including taking out old unserviceable one complete all as specified and directed. |
| 153 | S&F self starter motor, 12 volts of make LUCAS or its equivalent approved by OEM suitable for DG set of capacity up to 200 KVA including connecting electrically/ mechanically as per recommendations of OEM including taking out old unserviceable one complete all as specified and directed |
| 154 | S&F Speed Controller (Governor card) suitable for 100 KVA to 750KVA DG sets including taking down old unserviceable one complete all as specified and directed. |
| 155 | S&F Actuator suitable for 100 KVA to 250KVA DG sets including taking down old unserviceable one complete all as specified and directed. |
| 156 | S&F Fuel Sensor suitable for 100 KVA to 250KVA DG sets including taking down old unserviceable one complete all as specified and directed. |
| 157 | S&F in replacement of microprocessor based control unit suitable to DG set of any capacity with all listed parameters as per recommendation including testing complete all as specified and directed. |
| 158 | S &F in repair, Door hinges of any capacity of DG Sets as suitable for existing one complete all as specified and as directed. Make Kirloskar or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 159 | S &F in repair, Door lock of any capacity of DG Sets as suitable for existing one complete all as specified and as directed. Make Kirloskar or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 160 | Material and labour Bacteria culture for STP for developing MLSS and control odour complete all as specified and as directed.. Make: Organic plus or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 161 | Supply, Installation, Testing & Commissioning of 1 HP (0.75 kW) single phase booster pump, 230V, 50Hz, suitable for water pressure boosting application, complete with motor, mounting arrangement, accessories, testing and commissioning as required, complete all as specified and as directed. |
| 162 | Supply of ALUM (Aluminium Sulphate) water treatment chemical suitable for coagulation and flocculation process in WTP/ETP/STP systems, complete as specified and directed. |
| 163 | Supply and delivery of Calcium Hypochlorite Granules having available chlorine content of 65%–70%, suitable for water disinfection and chlorination in WTP/ETP/STP, overhead tanks, utility water systems and industrial/domestic water treatment applications, complete with packing, transportation and all incidental charges as required, complete all as specified and directed. |
| 164 | Supply and fixing LED BLDG Security Light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection including connection with twin twisted unsheathed PVC copper cable of suitable size along with suitable brackets with clamps, nuts and bolts Including taking down old unserviceable LED BLDG Security Light fitting complete all as specified and directed. |
| 165 | S&F GI tubing medium grade ISI marked including all fittings laid in trenches / fixed on wall of size 50mm bore complete all as specified and as directed. |
| 166 | All as per Item No. 164 above but of size 80 mm bore |
| 167 | S&F in repair 20W Coral LED Post Top gate light, spun aluminium landscape luminaire, IP 65 suitable for pole dia 76mm Including taking down old unserviceable LED Post Top gate light, complete all as specified and directed at site.Make : Havells Cat No. RUBYGENXPT40WLED730PSYMTOPC or CBP-610-40-57-SL-CA-NBK Of Crompton or techno commercially equivalent make in Wipro / Philips/makes listed in list of makes as approved by GE. |
| 168 | Submit STP Test Reports on Every Month as per ISO 9001 Certification for STP Plants at certain Units mentioned below STP PLANTS complete all as specified and as directed:-i) 20 BIHAR, ii) 4 Madras, iii) 9MT |
| 169 | Painting of DG Sets up to 250kva at various locations complete all as specified and as directed. |
| 170 | Supply and Replacement of 1.5 sqmm FRLSH copper cable complete all as specified and as directed. |
| 171 | Supply and Replacement of 2.5 sqmm FRLSH copper cable complete all as specified and as directed. |
| 172 | Supply and Replacement of 4 sqmm FRLSH copper cable complete all as specified and as directed. |
| 173 | Supply and Replacement of 6 sqmm FRLSH copper cable complete all as specified and as directed. |
| 174 | Supply and Replacement of pressure gauges of 20mm for swimming pool complete all as specified and as directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysSep 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender