Rural Development Government Departments Closing in 1 days TDR #57165622

Tender For Construction Of Boundry Wall With Gate, Deep Boaring, Reinforced Cement Concrete Basin With Open Dining Shed, Parking Shed, Toilet Unit, R And Renovation Of Old Building 8 Kitchen A Primary School, Nero Under Govindpur Block In Dhanbad Dis

Issued by Government Departments · Dhanbad, Jharkhand
Tender Value
56.15 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
1 days left
EMD
1.13 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dhanbad → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Boundry Wall With Gate, Deep Boaring, Reinforced Cement Concrete Basin With Open Dining Shed, Parking Shed, Toilet Unit, R And Renovation Of Old Building 8 Kitchen A Primary School, Nero Under Govindpur Block In Dhanbad District

BOQ

Name of Work:- Construction of Boundry Wall with Gate, Deep Boaring, RCC Basin with Open Dining shed, Parking Shed, Toilet Unit, R and Renovation of Old Building 8 Kitchen a primary School, Nero under Govindpur Block in Dhanbad District
Sl. No. Item Description
1Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I.
2Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
3Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layers 19mm. Thick (1:2:4)with 12mm to 6mm. Size graded stone chips and top layer 6mm. Thicks (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I.
4Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.
5Providing 12 mm Thk. cement plaster(1:6) on inside walls with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I.
6Providing 6 mm thick Cement plaster in (1:4) in Ceiling with clean course sand of F.M. 1.5 including the cost of screening, curring with all leads & lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I
7Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete
8Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.
9Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
10Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
11Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane anufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :
12Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
13Providing 150 mm wide BRICK DRAIN in cement mortar (1:6) with avarage 150mm. Clear depth and 125 mm apron including cost of earthwork involved with 75m cement concrete (1:4:3) over one brick designation 75A, flat soling in proper grade and slope at the base , the drain dully plastered in C.M.(1:3) with puning over exposed surface all complete as per building specification and direction of E/I.
14Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
15Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite stone slab colour black, Cherry/Ruby red
16Earth work excavation of foundation in hard or gravelly soil within initial lead of 50m and initial lift of 1.5m including dressing the sides, leveling the bed and depositing the excavated materials away from the work site, shoring etc if required, complete the item of work in all respect as per direction of the Engineer-in-charge.
17Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50M and lift of 1.5 M all complete as per building specification direction of E/I. (Mode of measurement compacted volume)
18Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
19Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I.
20Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
21Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
22Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
23Centring and shuttering including strutting, propping etc. and removal of form for foundation, footings, bases of columns etc. for mass concrete.
24Centring and shuttering including strutting, propping etc. and removal of form for lintel, beams, plinth beams, griders, bressumers and contilevers.
25Centring and shuttering including strutting, propping etc. and removal of form for columns, pillars, piers, abutments, posts and struts
26Weather shade, Chajjas, corbels etc., including edges
27Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick
28Providing Tor steel reinforcement of rods as per approved design and drawing including carriage of Rods (straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust,-do- TMTC-500 8mm dia @30%
29TMTC-500 10mm dia@30%
30TMTC-500 12,16mm dia@40%
31Providing designation 75 A brick work in C.M.(1 :6) in superstructure with approved quality of clean coarse sand of F.M. 2 to2.5 including providing 10 mm thick mortar joints cost of screening materials , scafolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l.
32Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper scaffolding , curing and taxes all complete as per building specification and direction of E/I.Extra each coat of cement wash ,distemper
33Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level:1:4:8 (1 cement: 4 coarse sand (zone-III) :8 graded stone aggregate 40 mm nominal size)
34Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
35Supplying, fitting and fixing M.S. grill gate with M.S. grill made of 20X6mm M.S. flats or 16mm M.S. square bars fitted on 25X25X6mm M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.
36Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig, air compressure and equipments as well as fule, lubricants and cost of transportation of rig machine annd other vehical up to Site. (a) From 0.00 M to 50.00 M below G.L.
37(b) From 51.0 M to125.00 M
38Supplying, assembling, lowering and fixing in vertical position in bore well, un-plasticized PVC medium well casing (CM) pipe of required dia, all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia.
39Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
40Supplying and commissionig of submersible pump set of reputed KSB/tTexmo make ISI, ISO 9001 marked or having ISO 9001-2000 submersible motor pump for HYDT & head of 100.00m having discharge 4000 l/hour and lowering mm dia PVC submersible schedule 80 pipe & 2.5 sq.mm size finolex copper cable about 80.00 m with main switch 32Amp & panel board sonsisting voltmeter ammeter, on/off switch HRC fuse unit and lighting arrangement, adobter, rope with all complete job as oer specification and direction of E/I2.0 HP
41Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS : 2800 (part I) including necessary bolts & nuts of requried size complete. 200 mm clamp
42Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittingswith one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Excluding GST) 32 mm nominal outer dia Pipes
43Supply fitting and fixing of standered make starter pannel board with arrangement of all necessary protection including all taxes royality etc. all complete job as per direction of E/I
44FR PVC Insulated 3 Core 4 Sqmm copper wire
45Polythene water storage tank of ISI Mark (e.g. Sintex/Sinter/Himgir/Gangotri etc.) with cover and locking system
46Providing designation 75 B Brick work in CM(1:6) In foundation and plinth do-do-E/I
47Providing P.C.C.M20 with nominal mix of (1:1.5:3) in foundation with approved quality of stone metal grade-III (50 mm to25mm size)clean coarse sand of F.M. 2.5 to 3including screening,shuttering,mixing cement concrete in mixer and placing in sition,vibrating,striking,curing taxes and royalty all complete. as per building specification and direction of E/I.
48Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
49Providing 12 mm thick cement plaster(1:4) with clean coarse sand of FM1.5including screening,curing,with all leads and lifts of water,scaffolding,taxes and royalty all complete as per specification and direction of E/I.
50Providing 1.5 mm thick cement punning including screening, curing,with all leads and lifts of water, scaffolding, royalty all complete as per pecification and direction of E/I.
51Providing and fixing chlorinated polyvinyl chloride (CPVC)pipes, having trermal stability for hot & cold water supply, including all CPVC plain & brass threaded fitting,i/c fixing the pipes with clamp at1.00m spacing.This includes jointing of pipes & fittings with one steps CPVC solvent cement and the cost of cutting chases and making good the same including testing ofd joints complete as per of derection of Engineer in charge. concealed work, including cutting chases and making good the wall etc. 18.8.1 15 mm nominal outer dia pipes
52Providing and fixing P.T.M.T. / C.P. extentsion Nipples 15mm size with 12” BSP threads, 70mm length and 30 mm bredth and weight not less than 18gms
53Providing And fixing 32 mm waste pipe for sink or wash basin including P.V.C. waste fittings complete.
54Providing and fixing C.P. brass Stop Cock (concealed) of standard designand of approved make conforming to IS 8931 15mm nominal bore, approved brand C.P. fittings.
55Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore
56Providing and laying DAMP PROOF COURSE 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse (zone-III): 4 graded stone aggregate 20 mm nominal size).
57Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
58Providing 125 mm thick REINFORCED DESIGNATION 75 A BRICK WORK in C.M. (1:4) in SUPERSTRUCTURE with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, cost of materials, racking out joints to 15 mm depth, carriage, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
59Providing structural steel galvanised tubular hollow section work in trusses, other similar trussed purlins and members with all bracing ,gusset plates etc as per detailed design and drawing or as directed by Engineer- in-charge,including cutting fabricating ,hoisting , erecting and fixing in position , making riveted/bolted /welded connections and one coat of anticorrosive paint and over it two coat of all oil painting & For Structure(PLUS) Providing and applying materials &labour for hot dip galvanizing of above structure including transportation for galvanizing minimum thickness 80microns (Net wt. of omponents to be Galv) preferably TATA structural section etc complete.
60Proving corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers field with white lead, including a coat of approved steel primer and two coats of approved paint on over apping of sheets complete up to any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cuting to size and shape wherever required. 0.80mm thick with zinc coating not less than 275gm m2
61Providing welder Grade-II for fixing the G.I. and placing in position all complete job.
62Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M 1.5 with 5 % cico or any approved water proofing compound including-----do-----
63Providing and laying double cherge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement @3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc.,complete. Size of Tile 600x600 mm
64Providing and laying 6mm precast white glazed tiles in walls over 12mm cement motar (1:3)and joined with grey cement slurry with \\"A\\"grade white 15 X15cm tiles.
65Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete
66Supplying, fitting and fixing fully glazed steel door, window or ventilations of standard rolled 'Z' and mullion steel sections and size as per IS-1038 joints met and welded with 100X16X3mm M.S. lugs fixed in cement concrete (1:2:4) block 15X10X10cm, size including cost of oxidised iron fittings, with hinges, handle per steps, catch springs, 3mm thick plain glass panes with Aluminimum beads and inner frame fixed with lugs with 20mm long 6.3mm G.I. counter sunk machine screw and nuts and applying a coat of red lead paint carriage to work site hoisting and placing in position in all storys and taxes all complete as per building specification and direction of E/I.
67Supplying,fitting and fixing M.S.grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage og grill to work site, hoisting as per building specification and direction of E/I.(where materials is not supplied by the deptt.)
68Making Soak Pit 2.5 m diameter 3.0 meter deep with 45x45cm dry briick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standerd design .
69Supllying and matarials with lobour for construction inspection chamber of designation class 75b brick deep 600x450 internal diamention having 250mm wall thickness in cement morter(1:6)including 12mm cement plaster (1:4)with punning on inside and cement plaster (1:6)with 600x450mm G.I. cover with frame (weight not less than 36k.g)in foundation and refilling all complete as per specification and direction of E/I.
70Providing 250 mm wide BRICK DRAIN in cement mortar (1:6) with avarage 150mm. Clear depth and 250 mm apron including cost of earthwork involved with 75m cement concrete (1:4:3) over one brick designation 75A, flat soling in proper grade and slope at the base, the drain dully plastered in C.M.(1:3) with puning over exposed surface all complete as per building specification and direction of E/I.
71Providing and fixing water closet squatting pan (Indian type W.C. pan ) with100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
72Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. Approved make supported on painted C.I. Or R.S. Bracket 32mm C.I. Brass waste, 15 mm dia C.I. Body brass spindle stop cock of approved quality of weight not less than 350 grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plunber joints etc. all complete as per specification and direction of E/I.
7320 mm nominal outer dia pipes
7432 mm dia.
75Providing and fixing PTMT / C.P Soap Dish Holder having length of 138 mm breadth 102 mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms
76Providing And fixing 32 mm waste pipe for sink or wash basin including P.V.C. waste fittings complete.
77Providing and fixing brass/C.I.Stop cock of approved quality all complete as per specification and direction of E/I. (A) BRASS STOP COCK
78Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
79Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. ( Single tee Without Door 110 mm)
8012.42.5Bend 87.5°
81Wiring for light point/ fan point/exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular switch ,modular plate, suitable GI box and earthing the point with 1.5sq mm FR PVC insulated copper conductor single core cable etc as required.
82S/F Batten / Angle Holder : Supplying and fixing batten / angle holder including connections etc. as required
83Providing, fitting, fixing & testing of (Essential) LED Lamp 15/16W LED in existing Battan / Angle Holder (Make – Philips / Bajaj / Crompton / Wipro)
8412\\" 300mm metal exaust fan
85S/F S.P. MCB DB 6 way , Single door
86Supplying and fixing 6 amps to 32 amps, rating, 240 volts, 'B' series, maniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required .
87s/f sheet metal on/off load changeover 32amps 2pole
88Wiring for circuit / sub main wiring alongwith earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/ recessed PVC coduit as required. (2x1.5 sq mm +1 x 1.5sq mm earth wire.)
89Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
90Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 gms
91Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter 3mtr length
92Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 110 mm
93Shoe (Plain) 110 mm Shoe
94Providing and fixing brass/C.I.Stop cock of approved quality all complete as per specification and direction of E/I. (A) BRASS STOP COCK
95Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I. (c) (i) C.P. Brass towel rail 20mmX600mm with bracket container
96(b) Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. Brass revolving fitting 3mm ply wood board and C.P. Hinges to fix with mirror. (i) 600mm X 450mm size
97Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 32 mm dia
98Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes
99Point wiring in PVC conduit, with modular type switch - Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box etc. as required. Group B
100Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 A socket outlet Each
1015/6 amps switch
102Circuit/submain wiring in PVC conduit - Wiring for Circuit/submain wiring along with earth wire the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required. 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire
1032 x 10.0 sq.mm. + 1 x 10.0 sq.mm. earth wire
104TPN MCB DB - Supplying and fixing following way, single pole and netural, steel sheet, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (vertical type MCB TPDB is MCB and incomer) 8 way, double door
105Providing 6A to 32 A, 3 P M.C.B. all complete with as per direction of E/I
106Providing T.P. & N isolator 415 volts suitable size all complete 63 amps
10715/16 Watt Led Bulb
108Supply Installation, testing and commissioning of follwing size ceiling fan 3 Blades confirming to13:374,.2019 including wiring the down rods of Standard length (upto 30cm) with l.Ssq.mm. FR PVC insulated, copper wire uitable for 230V 50H2, single phase supply etc. complete as required.
109Earthing with copper earth plate 600mrn x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) asrequt
110Providing and fixing 4 mm (8 SWG) dia copper wire on surface or in recess or loop earthing as required. (SOR)
111Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item - A0 and disposal of excavated earth as obtained to a distance upto 50M including all lifts levelling, ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I.
112Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B) TAKE 50% OF EXCAVATION
113Suspended floors, roofs, landings, balconies and access platform
114Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia
115Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
116Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge
117Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
118Excavating trenches of required width for pipes, cables etc. Including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5M including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering, etc. And disposing of surplus excavated soil as directed within a lead of 50 m Hard/dense soil. Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
119Providing and laying Non pressure NP2 class (light duty)RCC Pipes with collars jointed with stiff mixture of cement mortar in the propoertion of 1:2 (1 cement : 2 fine sand) including testing and jointing etc complete.
120Providing and fixing P.T.M.T. / C.P. extentsion Nipples 15mm size with 12” BSP threads, 70mm length and 30 mm bredth and weight not less than 18gms
121FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
122Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing therailing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc.,of required size, on the top of the floor or the side of waist slab with suitable arrangementas per approval of Engineer-in-charge, (for payment purpose only weight of stainless steelmembers shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
123Carraige of Materials : Sand Av. Lead 15 KmP
124Chips Av. Lead 10 KmP
125Cement Av. Lead 10 KmP
126Steel Av. Lead 10 KmP
127Bricks Av. Lead 15 KmP
128Goods & Service Tax (G.S.T.) -
129Labour Cess - Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57165622
AUTHORITY Government Departments
TENDER VALUE 56.15 Lakhs
LAST DATE 31-08-2026
Authority
Authority Name Rural Development Department
Work Description Tender for Construction Of Boundry Wall With Gate, Deep Boaring, Reinforced Cement Concrete Basin With Open Dining Shed, Parking Shed, Toilet Unit, R And Renovation Of Old Building 8 Kitchen A Primary School, Nero Under Govindpur Block In Dhanbad District
Basic Detail
Tender No 25/2026-27/RDSD/EE/Dhanbad/Gr. 07
Bidding Type Tender
Location
City Dhanbad
State Jharkhand
Key Dates
Publish Date 24 Aug 2026
Submission Date 31 Aug 2026
Open Date 02 Sep 2026
Finance
Tender Value 56.15 Lakhs
Tender Fee 10000
EMD 1.13 Lakhs
Exemption Not Available
Document List
1f1225e1-359b-4707-86bd-45d5868a2170.html
BOQ_159272.xls
SBDNit25Gr07DoubelBid.pdf
Tendernotice_1 (21).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Sep 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

1f1225e1-359b-4707-86bd-45d5868a2170.html

xls

BOQ_159272.xls

pdf

SBDNit25Gr07DoubelBid.pdf

pdf

Tendernotice_1 (21).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders