Power Boards / Undertakings / PSU Closing in 3 days TDR #57164179

Tender For Mini Mast Light Installation At Aruvikkara Lac Adv. Stephen Mla

Issued by Boards / Undertakings / PSU · Thiruvananthapuram, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
01 Sep 2026
3 days left
EMD
50000
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Mini Mast Light Installation At Aruvikkara Lac Adv. Stephen Mla

BOQ

Name of Work:- MINI MAST LIGHT INSTALLATION AT ARUVIKKARA LAC Adv. Stephen MLA
Sl. No. Item Description
1CIVIL WORKS-MINI MAST-STADIUM
2Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
4Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
6Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
7Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
8Fabrication ,supply, conveyance and installation of Granite name board indicating the cost involved, the commencement, completion and inauguration date etc
9ELECTRICAL WORKS-MINI MAST-STADIUM
10Supply, installation, testing and commissioning of Outdoor Floor / Wall Mounting Cubical Type KSEBL Metering Panel with Double Door and Canopy suitable for 240 V, Single Phase, 2 Wire 50 Hz AC supply system having sufficient front surface area fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame works and covers, 2 mm thick for gland plates, cleaning and finishing complete with 7 tank process for Powder Coating in approved shade and then provided with Clear Coating, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 12 mm x 3 mm at the rear with 2 Nos. earth stud and control wiring with 2.5 / 1.5 Sq.mm FRLS (Flame Retardant Low Smoke) or HRFR (Heat Resistant Flame Retardant) PVC insulated single core copper conductor cables, cable alleys etc. complete as required. The panel shall conform to the Electrical Inspectorate and KSEBL standards and it shall only be manufactured after getting approval from the Engineer-in-charge and the Consultant. INCOMER: 1 Nos- Provision for Fixing Single Phase Energy Meter 1 Nos - 32A Bakelite Fuse Units with HRC Fuse of Suitable Rating 1 Nos - 32A Neutral Link 1 Nos - 25A DP Isolator There shall be Separate Compartment for Energy Meter and Fuse Units/Neutral Link with KSEBL Sealing Provision OUTGOING: 1 Nos - Outdoor / Street Light Compartment with 25A 10kA DP C Curve MCB, 25A 30mA DP RCCB, 9A/12A TP AC3 Duty Contactor with Auxiliary Contacts, 24Hour Digital Timer Switch, Auto - Manual Selector Switch (2 Pole 2 Way), ON (Red), OFF (Green) Push Buttons and ON (Red), OFF (Red) Indication lamps with Control MCBs
11Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
12Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98,RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartmentshould be seperatly accessible for maintenance (LM 79&80 certificates fromNABL accredited Third party lab to be produced mentioning chip manufacturer)
13Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
14Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
15Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
16Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
17Supply and laying of XLPE insulated and PVC sheathed armoured Aluminium power cable of 1.1 kV grade of the following sizes in the existing excavated trenches, built up trenches and pulling through existing pipes including all minor civil works etc. complete as required 2 Core 10 Sq.mm
18Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp
19Supply and laying of XLPE insulated and PVC sheathed armoured Aluminium power cable of 1.1 kV grade of the following sizes in the existing excavated trenches, built up trenches and pulling through existing pipes including all minor civil works etc. complete as required 2 Core 6 Sq.mm
20Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp
21Supply and laying of 1.5 Sq.mm 1.1kV Grade Three Core Round Insulated Copper Conductor and Sheathed Flexible cable with compact construction and high insulation resistance. The cable shall have the specifications of Standard FRLS PVC Insulation, FRLS Sheathing in accordance with IS 694, BS 6500, IEC 60227, DIN VDE-0281, IEC 60754-I IEC, 60332-I, BS 4066-I, ASTMD 2843, ASTMD 2863, Conductor Class 5, Number of Conductor Strands 30, Nominal Diameter of Conductor Strands 0.25mm, Nominal Thickness of Insulation 0.6mm, Nominal Thickness of Sheath 0.9mm, Approximate Overall Diameter 8.2mm, AC Current Rating of 18A, Voltage Drop/Amp/Metre for Single Phase AC 31mV, Maximum Conductor Resistance at 20 Deg.C 13.3 Ohms/Km etc. complete as required
22Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
23Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
24Supply and providing gland earthing using Gland Earthing Clips / Clamps for following size of PVC insulated and PVC sheathed / XLPE Aluminium conductor cable of 1.1 kV grade etc. complete as required 2 X 6 Sq.mm
25Supply and providing gland earthing using Gland Earthing Clips / Clamps forfollowing size of PVC insulated and PVC sheathed / XLPE Aluminium conductorcable of 1.1 kV grade etc. complete as required 2 X 10 Sq.mm
26Excavation of all types of soils for the laying of PVC insulated and PVC sheathed / XLPE Aluminium or Copper conductor cable, GI / DWC HDPE / RCC / PVC / Conduit Pipes, Earthing conductors to the required width and depth up to and including 1.2m and back filling etc. complete as required. (The trench dimensions and specifications shall conform to CPWD / PWD, Electrical Inspectorate and KSEBL Standards)
27Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal/ coke and salt) as required
28Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.06 mm GI conductor (8 SWG)
29Supply and installation of 10 kg/cm2 PVC Pipes of the following sizes with all necessary accessories and laying in existing excavated trenches, built up trenches, clamping in built up trenches / walls / MS supports using Stainless Steel saddles and screws of which spacing between 30cm to 60cm including all minor civil works etc. complete as required Up to and including 40mm
30Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
31Supply, fabrication and installation of Outdoor Floor / Wall Mounting Cubical Type KSEBL Metering Panel / PVC Pipe / Cable supports etc. using MS Angles, Flats and C Channels of adequate size painted with two coats of epoxy primer and two coats of black / grey / other approved shade epoxy paint. The scope also the includes the supply and installation of necessary rectangular / square plates, anchor fasteners, bolts, nuts, round and spring washers or screws etc. complete as required
32Preparation and submission of application for Single Phase Connection along withdrawings, detailed load schedule etc. and co-ordination with KSEBL for energizationetc. complete as required. (*All Statutory fees for getting connection shall also comewithin the scope of the Contractor). This scope also includes any additional chargesfor getting connection like two electric posts and overhead lines etc.
33KSEB Connection Charges
34CIVIL WORKS-HIGH MAST
35Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
36Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
37Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
38Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
39Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
40Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
41Fabrication ,supply, conveyance and installation of Granite name board indicating the cost involved, the commencement, completion and inauguration date etc
42ELECTRICAL WORK-MINI MAST
43Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
44Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
45Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
46Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
47Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
48Supply and fixing of 25A 2 Pole AC 1 rated power contactor, 25A Connector, Digital timer, Suitable Copper socket, 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable, 1.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable
49Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable
50Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
51Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm
52Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size (SWG)
53Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm GI strip
54Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
55Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
56Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
57Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
58Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
59Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
60Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
61KSEB Connection Charges Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57164179
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 01-09-2026
Authority
Authority Name United Electrical Industries Limited
Work Description Tender for Mini Mast Light Installation At Aruvikkara Lac Adv. Stephen Mla
Basic Detail
Tender No PMC/MARKETING/046/2026-2027 DT-22.08.2026
Bidding Type Tender
Location
City Thiruvananthapuram
State Kerala
Key Dates
Publish Date 24 Aug 2026
Submission Date 01 Sep 2026
Open Date 02 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 2950
EMD 50000
Exemption Available
Document List
BOQ_1466420.xls
c286167b-1695-4ccd-a6f8-47bcf41d368e.html
GCC046.pdf
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Sep 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1466420.xls

html

c286167b-1695-4ccd-a6f8-47bcf41d368e.html

pdf

GCC046.pdf

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders