Tender For Providing Of Certain Rev And Minor Work At Various Location At Vsn Chiloda Under Ge(Af) Chiloda
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation and testing of pressure pump 0.75 HP with copper wounded motor 50 Hz, voltage range 180V-260V, SS shaft,water tank as per capacity of pump, including pressure gauge ,NRV and Y strainer complete all as specified and directed |
| 2 | Supply, installation and testing of Open well submersible pump of capacity 3 HP, three phase, 380v-415v, 50Hz, AC, copper winding, Cast iron body, delivery size 50mm complete all as specified and directed . |
| 3 | Supply, installation and testing of Openwell submersible pump of capacity 1 hp, single phase, 240, 50Hz, AC, copper winding, stainless steel body, delivery size 25 mm with control panel complete all as specified and directed |
| 4 | Supply, installtion and testing of 3-Phase Squirrel cage induction motor Foot-Mounted, 2.23 kW (3 HP), 415 V, 50Hz, 710 RPM, 4-Pole, voltage range 373V-456V, IP 55 (For small cooling tower) complete all as specified and directed. |
| 5 | Supply, installtion and testing of 3-Phase Squirrel cage induction motor Foot-Mounted, 3.7 kW (5 HP), 415 V, 50Hz,1430 RPM, 4-Pole, voltage range 373V-456V, IP 55 (For AHU) complete all as specified and directed |
| 6 | Supply,installtion and testing of 3-Phase Squirrel cage induction motor Foot-Mounted, 7.5 kW (10 HP), 415 V, 50Hz, 1450 RPM, 4-Pole, voltage range 373V-456V, IP 55 (For AHU) complete all as specified and directed. |
| 7 | Supply,installtion and testing of 3-Phase Squirrel cage induction motor Foot-Mounted, 9.3 kW (12.5 HP), 415 V, 50Hz, 570 RPM, 4-Pole, voltage range 373V-456V, IP 55 (for Cooling Tower) complete all as specified and directed. |
| 8 | Supply, lowering, installation and testing of openwell submersible pump 30HP/22KW, suction size 100mm, delivery size 80mm, Head range 33-60mtr, Horizontal type, 2200-1100 LPH complete all as specified and directed. |
| 9 | S&F Warm white PAR light, 4 eyes, 240 Volt, 50Hz Ac. 50x4=200 Watt, suitable to operate in Auto/Manual mode complete all as specified and directed. |
| 10 | S&F Warm white Profile spot light, 240 Volt, 50Hz Ac, 200 Watt, suitable to operate in Auto/Manual mode complete all as specified and directed. |
| 11 | M&L for DMX XLR cable 1.2 mtr length 3 pin XLR male to female connector for stage lighting complete all as specified and directed. |
| 12 | M&L for copper control cable 2.5 sqmm 3 core, PVC sheathed, flexible complete all as specified and directed. |
| 13 | Supply and fix UPS for 7-10 min back up single phase AC input 160 to 260 V and out put 230 ± 1% of capacity 6 KVA complete all as specified and directed. |
| 14 | Supply, installation and testing of Split type Airconditioner, 2 Ton, BEE 5 star rated, Inverter type, Variable speed compresor, Copper condenser and evaporator, operating voltage 155V-280V, Noise level 31 db(A) complete all with standared accessories complete all as specified and directed. |
| 15 | Supply, installation, testing and commissioning of Tower type AC, 2 Ton, 230V, 50 Hz, Rated EER 3.31 W/W, Noise level less than 43 db(A), rotary burst proof compressor, Airflow 1000 CMH including copper pipe,drain pipe and ziri work upto 15 feet complete all as specified and directed. |
| 16 | Supply, installation, testing and commissioning of Tower type AC, 3 Ton, 415V, 50 Hz, Rated EER 2.80 W/W, Noise level less than 55 db(A), rotary burst proof compressor, Airflow 1500 CMH including copper pipe,drain pipe and ziri work upto 15 feet complete all as specified and directed. |
| 17 | Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) ,complete all as specified and directed. |
| 18 | M&L for Wiring circuit/ submain along with earth wire with 4 X 6 sq. mm + 2 X 6 sq. mm earth wire sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required ,complete all as specified and directed.(a) ,complete all as specified and directed. |
| 19 | M&L for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade Upto 35 sq. mm size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 20 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. complete all as specified and directed. |
| 21 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Double poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. complete all as specified and directed. |
| 22 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Triple poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. complete all as specified and directed. |
| 23 | Supplying and fixingv 63 amps rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. complete all as specified and directed. |
| 24 | Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 amps 415 volts \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required.complete all as specified and directed. |
| 25 | Supply & fix Air Circulator (Wall mounted) fans 230 volts single phase oscillating, silent operation, 400 mm sweep BLDC Fan with remote suitable for wall mounting complete all as specified and directed. |
| 26 | Supply&fixed Pedstal fans 230 volts single phase oscillating, silent operation, 450 mm sweep, strong and stable base, Jerk free operation, smooth swing operation, 3 speed control complete all as specified and directed. |
| 27 | M&L Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc as required.complete all as specified and directed. Please Enable Macros to View BoQ information |
| 28 | M&L Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc as required.complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysSep 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender