Tender For Comprehensive Maintenance Of 33 Kv Substation Yards At Mrs & Stn Hq Including 33 Kv Oh Line From 132 To 33 Kv Stn Hq At Mil Stn Jaisalmer
Tender Value
60 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
27 days left
EMD
1.15 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jaisalmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Comprehensive Maintenance Of 33 Kv Substation Yards At Mrs & Stn Hq Including 33 Kv Oh Line From 132 To 33 Kv Stn Hq At Mil Stn Jaisalmer
BOQ
| Sl. No. | Item Description |
| 1 | Supply & fix in repair insulator, disc type Polymer series in three with hardware, vitreous,white, brown or green of suitable size socket type, single disc assembly for tension clamp for conductor working pressure 33000 Volt complete including necessary hardware of washers,nut,bolts etc all as specified and directed. |
| 2 | Supply & fix in repair insulator, pin type,polymer vitreous,white, brown or green of suitable size with clamp for conductor working pressure 33000 Volt complete including necessary hardware of washers,nut,bolts etc all as specified and directed. |
| 3 | Supply & fix in repair disc/suspension insulators for suspension strings on poles of suitable size with clamp for conductor working pressure 33000 Volt complete all as specified and directed. |
| 4 | Supply & fix in repair strain insulators at sharp curves,high tension araes on poles of suitable size with clamp for conductor working pressure 33000 Volt complete all as specified and directed. |
| 5 | Supply & Fixing in repair lightening arrestors 33 KV, 10 KA station type Class including all clamps, nuts, bolts and washers and connection to earth with 32x6mm GI strip complete and including taking down old unsv LA complete all as specified & directed by Engr-in-Charge. |
| 6 | Material and labour in repair for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (9 insulators type & 6 insulators for DO with horizontal operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 400 Amps 33000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type/horngap type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including applying petroleum jelly at contact area and taking down old switch air break gang operated complete all as specified. (stack for fixing with poles shall be measure and paid separately). |
| 7 | Material and labour in repair for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (9 insulators type & 6 insulators for DO with horizontal operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 400 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type/horngap type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including applying petroleum jelly at contact area and taking down old switch air break gang operated complete all as specified. (stack for fixing with poles shall be measure and paid separately). |
| 8 | Material and labour in repair for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (9 insulators Vertical type operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 400 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type/horngap type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including applying petroleum jelly at contact area and taking down old switch air break gang operated complete all as specified. (stack for fixing with poles shall be measure and paid separately). |
| 9 | M&L in replacement of cable Jointing kit for 33 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sqmm complete all as specified and as directed by Engineer-in-Charge. Make:Raychem RPG/3M |
| 10 | M&L in replacement of cable Jointing kit for 33 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sqmm complete all as specified and as directed by Engineer-in-Charge.Make:Raychem RPG/3M |
| 11 | Supply, Jointing and testing in replacement of out door type cable termination heat shrinkable joint kit suitable for size 95 Sq mm 3 core 11KV (Earthed cable) under ground XLPE cable and including taking down old unsv joint complete all as directed by Engr-in-Charge.Make:Raychem RPG/3M |
| 12 | --- ditto --- all as per item No 11 above but size of 185 Sqmm 3 Core.Make:Raychem RPG/3M |
| 13 | Supply, Jointing and testing in replacement of in door type cable termination heat shrinkable joint kit suitable for 95 Sq mm 3 core 11 KV (Earthed cable) under ground XLPE cable all as directed by Engr-in-Charge.Make:Raychem RPG/3M |
| 14 | --- ditto --- all as per item No 13 above but size of 185 Sqmm 3 Core .Make:Raychem RPG/3M |
| 15 | Supply jointing and testing in replacement of straight through heat shrinkable joint kit suitable for 95 Sq mm 3 core 11 KV (Earthed cable) under ground XLPE cable complete and including taking down old unsv joint complete all as directed by Engr-in-Charge. Make:Raychem RPG/3M |
| 16 | --- ditto --- all as per item No 15 above but size of 185 Sqmm 3 Core .Make:Raychem RPG/3M |
| 17 | S&F in repair fuse wire suitable for horn gap fuse units at various locations of following capacity/size :- |
| 18 | (d) 40 Amp |
| 19 | (e) 50 Amp |
| 20 | (f) 60 Amp |
| 21 | Supply, laying & testing in replacement of XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 185 sqmm, 3 core specification as per IS:7098 Part-2 incl taking down unsv one complete. all as specified and as directed by Engr -in- Charge. |
| 22 | Supply, laying & testing in replacement of XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 120 sqmm, 3 core as per IS:7098 Part-2 and incl taking down unsv cable complete all as specified and as directed by Engr -in- Charge. |
| 23 | Supply, laying & testing in replacement of XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 95 sqmm, 3 core as per IS:7098 Part-2 incl taking down unsv cable complete.all as specified and as directed by Engr -in- Charge. |
| 24 | Supply and lay in repair cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 33000 Volt grade with stranded aluminium conductor of size 185 Sqmm 3.0 Core as per IS:7098 Part-2 complete all as specified and directed. |
| 25 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc not exceeding 10 sqm on plan and getting out in Soft/disintegrated rock complete all as specified & directed by Engineer-in-Charge. |
| 26 | Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.00m depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge. |
| 27 | Returning, filling in, including, spreading, levelling, watering and well ramming excavated Soft/Disintegrated rock in layers all as specified & directed at site. |
| 28 | Removing excavated Soft/Disintegrated rock to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed by Engineer-in-Charge. |
| 29 | Supply, laying in repair and Jointing 150mmX130 mm outer dia and inner dia , HDPE double walled corrugated (DWC) pipe conforming to IS-16205 with antirodent and non flame propogating properties of approved colour including necessay fittings like bend, tee, elbow,socket etc. for cable protection complete all as specified and as directed.Note :- Joints are designed to be watertight and moisture proof. |
| 30 | Material and labour for cutting the existing bituminous road / hard standing to size not exceeding 45cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete 1:3:6, type C1 using 20mm graded aggregate complete all as specified and directed by Engineer-in-Charge. |
| 31 | S&F in repair GI pipe light grade of dia 150 mm laying in road and along with poles for cable protection complete and including taking down old unsv pipe of 80mm dia complete all as directed by Engr-in-Charge. |
| 32 | M & L for cement concrete (1:3:6) type C-1 using 20mm grade stone aggregate for foundation of stay assembly struts or pole etc complete all as directed. |
| 33 | M & L for cement concrete (1:2:4) type B-1 using 20mm grade stone aggregate for coping around poles including necessary form work finishing even and smoth with out using extra cement complete all as directed. |
| 34 | M & L for cement concrete (1:4:8) type D-2 using 40mm grade stone aggregate in foundation of PCC pole/struts as specified including necessary form work finishing even and smoth with out using extra cement complete all as directed. |
| 35 | M&L for Removing grass and bushes including its roots growing at Substation yard and keep the sub station yard neat and cleanat an interval of 1 month time and thrown at prescribed location complete all as specified and as directed. |
| 36 | Material and labour for substation yard spreading levelling with 40 mm graded coarse aggregate / gravells laid approximately 75 mm thick layers near VCB/Transformer /2/4 pole structure and plateform etc all as directed. |
| 37 | Material and labour for substation yard spreading levelling with 20 mm graded coarse aggregate / gravells laid approximately 75 mm thick layers near VCB/Transformer /2/4 pole structure and plateform etc all as directed. |
| 38 | M&L for Cuttting / trimming of tree branches at elevated height in close proximity to over head lines to maintain a clearance of 2.0 meters from the over head line to nearby trees complete all as specified. Note :- Only effected area between two poles of over head conductor shall be measured as one pan |
| 39 | M&L in replacement of for aluminium conductor steel reinforced (ACSR) for jumpering and incl taking down unsv conductor complete all as specified and as directed by Engr-in- Charge. |
| 40 | M& L for removing of damaged 11 meter PCC/RCC poles with necessary gurad wire,bracket,overhead mounting bracket with insulators including reconnect the existing OH Conductor in original position complete all as directed.Note: (i)Necessary hydra/crane/JCB to carryout the work is deemed to be inclusive.(ii) Old unsv insulators,guard wire,cross arms and new steel poles will be measured and paid separately if required on ground.(iii)Old unsv PCC/RCC poles will be deposited/dumped all as directed by Engr-In-Charge |
| 41 | M &L steel tubular swaged poles and complete with cast iron / M.S base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 mtrs long) including painting with one coat of aluminium paint over a coat of red oxide metal primer before erection and 2nd coat of aluminium paint after erection complete all as specified and directed by Engr-in-Charge. The pole shall conform to IS 2713:1980 and each component pipe shall be ISI marked and conform to IS 1161 and including taking down old unsv pole and PCC/RCC debris from site complete all as specified and directed by Engr-in Charge. |
| 42 | S&F in repair mild steel Chequered Plate upto 6mm thick Square cut to required size for cable duct cover , inclusive of one primer coat of red oxide zinc chrome primer and two coats of black paint complete and including taking down old rusted unsv plate complete all as specified and as directed by Engr-in-Charge. |
| 43 | M&L for providing technical staff with equpiment to finding cable fault with electronic fault detector in LT/HT UG cable of any size complete including earthwork and jointing cable on priority with in short duration from cable fault complete all as specified and directed by Engineer-in-Charge.Note: Jointing cable item rates to be paid separately. |
| 44 | Supply and fixing in replacement of HT feeder Piller Box outdoor type double door front openable in two half not less than 1.20mx1.20mx1.00m made out of 3.15 mm thick CRCA sheet podwer coated paint in heat process of sheet, supported on angle iron frame 50x50x6mm having legs 1.2,mtr long grouted in PCC upto 60cm, aluminium bus bar 03 Nos rated capacity 200A (HT) duly insulated 11000 Volt grade for phases supported on HT polymer insulator and having red colour danger notice plate with skull symbol duly riveted PCC foundation 1:2:4 completed including provn of Al drop locking arrangement on front and bcak side all as specified and as directed by Engr in Charge. Please Enable Macros to View BoQ information |
| 45 | Supply and fixing in replacement of HT feeder Piller Box outdoor type double door front openable in two half not less than 1.20mx1.20mx1.00m made out of 3.15 mm thick CRCA sheet podwer coated paint in heat process of sheet, supported on angle iron frame 50x50x6mm having legs 1.2,mtr long grouted in PCC upto 60cm, aluminium bus bar 03 Nos rated capacity 200A (HT) duly insulated 11000 Volt grade for phases supported on HT polymer insulator and having red colour danger notice plate with skull symbol duly riveted PCC foundation 1:2:4 completed including provn of Al drop locking arrangement on front and bcak side all as specified and as directed by Engr in Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 27 daysSep 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 28 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender