Tender For Supply, Installation, Commissioning Of Laboratory Items
Tender Overview
Project Description
Tender For Supply, Installation, Commissioning Of Laboratory Items , Laboratory Equipment , Fourier Transformed Infrared Spectroscopy- Attenuated Total Reflectance (Atr-Ftir) (1Ps.) Technical Specifications Optical System The Spectrometer Should Be Able To Record The Spectrum Of A Sample In The Wave Number Region Of 7900 - 350 Cm-1. The System Should Be Sealed And Desiccated. Rechargeable Desiccant Cartridges With Humidity Indicator. Continuous Electronic Monitoring Of Multiple Spectrometer Components With Temperature And Humidity Sensors. Spectrometer Must Provide A 10 Years Warranty On The Interferometer, Laser, And Source. Desiccant, Power Supply, Sample Compartment Windows, Infrared Source Must Be User Replaceable Without Opening The Cover. Interferometer Interferometer Must Be A With Dynamic Alignment To Provide High Spectral Resolution And Compensate For Tilt, Shear, Temperature Effects, And Vibrations That Alter Line Shapes And Negatively Impact Spectral Results. Spectral Resolution 0.6 Cm-1 Spectral Resolution Or Better Signal To Noise Ratio Better Than 35,000:1 (Peak-To-Peak, One Minute) Wave Number Precision Better Than 0.001 Cm-1 At 2,000 Cm-1 Wave Number Accuracy Better Than 0.05 Cm-1 At 2,000 Cm-1 Ordinate Linearity 0.15 %T Detector Deuterated Triglycine Sulfate (Dtgs) Detector Source Spectrometer Must Have A Non-Migrating Hotspot Single-Point Source With A 10-Year Warranty. Laser Solid-State, Temperature-Controlled Diode Laser With Long Lifetime With A 10-Year Warranty Smart Background Collection (Background Collected While Instrument Is Idle) Instrument Calibration/ Performance Verification The System Must Be Provided With Internal Nist-Traceable 1.5 Mil Polystyrene Film (Serialized). Accessories Spectrometer Must Accept A Wide Variety Of Third-Party Accessories To Maximize Flexibility And Minimize Future Upgrade Costs. Transmission Analysis Transmission Accessory Must Be Quoted For Liquid Sample Analysis From Oem. Atr Atr Accessary Should Include Diamond Atr Crystal With Optical Base. Both Diamond Atr Crystal And Optical Base Must Be Provided With At Least 5 Years Of Warranty. Software Instrument Should Have Mechanism To Automatic Atmospheric Suppression To Remove Moisture And Co2 Interferences. Advanced Data Processing Options Like Baseline Correction, Peak Area, Peak Height Measurements, Smoothing, Spectral Comparison Etc. Must Be Available. Software Should Have Tools For Quantification Method Development Using Beers Law, Pls, Cls Etc Additional Software Should Be Provided For Multi-Component Search Of Mixture Samples And Should Have Ir Interpretation Tools. Software Must Have The Ability To Automatically Create A Workflow Based On The Processing History Of A Spectrum. Library Ftir Spectral Libraries Must Be Available With At Least 5000 Or More Spectra. Other Requirement Branded Desktop Pc & Printer, Suitable Online One Kva Ups For Ftir System. Warranty The Complete System Should Be Covered With One Year Of Warranty Special Warranty: - • 10 Years On Laser, Source & Interferometer • 5 Years On Complete Diamond Atr Including Diamond Cystal. , Water Maker Type I (1Ps.) Technical Specification: Integrated Lab Water System That Will Deliver Type 2 And Type 1 From A Single Unit. Feed Water Specifications: Tds 500Ppm Product Water Type Ii : 10Mω Type I : 18.2 Mω Type I Toc 5Ppb Flow Rate Type Ii : 10 Liters Per Hour Type I : 1 -1.5 Liters Per Minute Type Ii Water Storage Capacity: 25 Liters Shape: Conical Bottom Vent Filter To Avoid Atmospheric Contamination Should Have In Built Uv Sanitization Module Fixed In The Tank Auto Cutoff Once The Tank Is Filled Provision To Collect Type Ii Water From The Tank Easy Single Touch Type I Water Dispensing Convenient User Interface With Minimum Display And Alarm Indication Like Product Water Resistivity, Low Feed Water Alarm And Power On Indication Purification Steps Should Involve Depth Filter To Remove Particulate Activated Carbon To Remove Chlorine And Organic Reverse Osmosis Membrane Dual Wave Length Uv To Reduce Toc Deionization Purification Pack To Produce Ultra-Pure Water Ultra Filtration For Dnase Rnase Free Water 0.2-Micron Filter At The Point Of Use To Have Particulate And Bacteria Free Ultra-Pure Water Dispensing Use Of Electrostatic Sanitization (Ess/Eps) To Avoid Chemical Sanitization Of Ro Membrane Warranty: 24 Months , Semi-Dry Electrophoretic Transfer And Power Supply (1Ps.) Technical Specifications: Fast Blotting System With Four Gel Simultaneously, 2 Different Cassettes Same Protocol At Different Time In 3 Mins. System Should Be Open For Traditional Blotting Consumables System Should Have Inbuilt Fix Electrodes Input Power: 100-240 Vac, 276 Va, 50-60 Hz, 175 W Max Usb Port: Yes, Input Only, For Firmware Updates System Should Have Cooling Fan Should Have Inbuilt Power Supply With High Current Of 2.5 A User Interface 18 Button Keypad, 128 X 64 Pixel Monochrome Display Programmable Methods: Up To 25 User-Defined Preprogrammed Methods: Standard Sd, 1.5 Mm Gels, High Mw, Low Mw, Mixed Mw, Audible Alarm: Yes User Notifications Should Have Following Features: • Power Fail During Run • No-Load Detection • No Cassette Detection • End Of Run , Optical Do Meter- Portable (1Ps.) Technical Specifications: Dissolved Oxygen Measurement Type Optical - Luminescence Dissolved Oxygen Range 0.00 To 50.00 Mg/L (Ppm); 0.0 To 500.0% Saturation Dissolved Oxygen Resolution 0.01 Mg/L (Ppm); 0.1% Saturation Dissolved Oxygen Accuracy 1.5% Of Reading ± 0.01Mg/L For 0.00-20.00Mg/L , 5% Of Reading For 20.00-50.00Mg/L , 1.5% Of Reading ±0.1% For 00-200.0%, 5% Of Reading For 200.0-500.0% Dissolved Oxygen Calibration One Or Two Points Automatic Calibration At 100% (8.26 Mg/L) And 0% (0 Mg/L); Single Point Manual Using A Value Entered By The User In % Saturation Or Mg/L. Dissolved Oxygen Temperature Compensation Automatic From -5.0 To 50.0 °C (23.0 To 122.0 °F) Barometric Pressure Compensation Automatic From 420 To 850 Mmhg Salinity Compensation Automatic From 0 To 70 G/L (Manually Set) Temperature Range -5.0 To 50.0 °C (23 To 122 °F) Temperature Resolution 0.1 °C (0.1 °F) Temperature Accuracy ±0.3 °C (±0.4 °F) Temperature Calibration Single Point Anywhere Within Temperature Range Temperature Compensation Automatic Do Probe Optical Do Probe With Protective Sleeve, Internal Temperature Sensor, Quick Connect Din Connector And 4M (13) Cable (Included) Logging Type On Demand With 4000 Records Capability Connectivity Usb-C Automatic Shut-Off User Selectable: 5, 10, 30, 60 Minutes Or Disabled Glp Yes- Includes Last 5 Calibrations Calibration Timeout Reminder Yes- User Selectable Calibration Due Warning Autoend Yes Bod/Our/Sour Yes Display Lcd (Back Lighted Display) Battery Type/Life 1.5V Aa Batteries (4 Pcs.) / Approx. 200 Hours Of Continuous Use Without Backlight (50 Hours With Backlight) Ip Protection Ip67 Environment 0 To 50 °C (32 To 122 °F) Max. Rh 100% Dimensions 185 X 93 X 35.2 Mm (7.3 X 3.6 X 1.4) Weight 450 G (15.9 Oz.) With Batteries Include Do Meter Is Supplied With Optical Do Probe, Smartcap With Rfid, Bicomponent Zero Oxygen Solution, 100 Ml Plastic Beakers (2), Micro Usb Type A To C Cable, 1.5V Aa Batteries (4), Instruction Manual, Quick Start Guide, Instrument Quality Certificate And A Rugged Carrying Case. Increased Traceabilty Ensure That Your Data Can Be Trusted With Glp Data. Accessible By A Fixed Dedicated Key, This Data Includes Date, Time, Pressure, Calibrated Value, Temperature And Salinity Value Of The Last Calibration. Versatile Data Logging The Meter Log-On-Demand Feature Allows You To Store Up To 4000 Readings. The Autoend Button Can Be Used During Measurement To Hold The First Stable Reading On The Display Automatically. Smart Cap Technology And Automatic Cap Recognition Smart Caps Feature A Built-In Rfid Reader That Is Able To Store Important Data, Including Manufacture Date And First-Use Date For Increased Traceabilty. Quick Connect Probe The Quick Connect Fitting Is Designed For Quick And Easy Installation Of The Do Probe. A Watertight Connection Without Threads Make Attaching And Removing The Probe Simple. , Autoclave (2Ps.) Technical Specification: Type: Vertical Autoclave. Size: 16X 24. 80 Lt. App. Pressure Cut Out: Automatic Temperature Cut Out: Automatic Gasket: Silicon Timer: Digital, Materials: Outer Ss, Inner Ss, Others: Safety Valve, Drain. , Vacuum Pump (1Ps.) Technical Specification: Power: 220V/50Hz Max Power (W): 80 Max Vacuum: -67Mmhg Max Flow Rate: 34Lit/Min Motor Rotation: 1450 Rpm Horse Power: 1/6 Hp Noise Level: 52 Db , Horizontal Electrophoresis System And Power Supply (1Ps.) Technical Specification: 1. A Midi Horizontal Electrophoresis System Should Be Able To Run The Gel Size Of 15 X 7Cm, 15 X 10 Cm. The System Should Be Supplied With 15 X 10 Cm Gel Trays With Gel Tank With Safety Lid. 2. The Supplied Gel Trays Should Be Uv Proof And The Trays Can Be Directly Kept On The Uv Transilluminator And Should Have A Integrated Fluorescent Ruler In The Tray. The Ruler Should Get Illuminated On Exposure To Uv Light For Easy And Safe Calculation Of The Band Movements. 3. A System Should Include Tape Free Gel Casting Module For Leak Free Operations. 4. A System Should Include Two 1.5Mm Combs, 15- & 20-Well Fixed Height Combs Each. 5. A System Should Have The Option For Adjustable Height Combs With Comb Holders. 6. Migration Rate Of Bromophenol Blue Dye Should Be Similar To 4.5Cm/Hr(At 75 V). 7. A System Should Have A Lid With The Safety Banana Jacks, Which Breaks The Circuit When The Lid Is Running. 8. Should Be Provided With A Bubble Leveler For Even Gel Casting. 9. The Gel Caster Should Have 3 Height Adjustable Screws For Balancing The Uneven Platforms For Uniform Gel Casting. 10. The Electrodes Should Be Color Coded To Remove The Confusion Of Wrong Orientation. 11. The Lid Should Have A Safety Option So That The Lid Cannot Be Closed In The Wrong Orientation. 12. The Lid Should Have Integrated Cables To Connect It To The Power Pack Directly. 13. The System Should Be Able Run 60 Analytical Samples In Single Tray Of 15X 10 Cm Power Supply Basic- Programmable Power Supply Should Be Capable To Operate Four Electrophoresis Units Simultaneously For Four Identical Runs With Graphic Led Display. The Output Range Should Be 10-300 V , 0.4-400 Ma, 1-75 W . Constant Voltage, Current Or Power With Automatic Crossover Memory Storage: 9 Programs , 9 Steps, Timer Control : 99 Hr, 59 Min Automatic Power Up After Power Failure, Safety Features: No-Load Detection; Sudden Load Change Detection. , Non-Refrigerated Centrifuge And Fixed Angle Rotor 24X2Ml (1Ps.) Technical Specification: Rotor Capacity (Max): 4 X 100 Ml 32 X 6 Ml (Swing Out) & 30 X 15 Ml (Fixed Rotor) Max Rpm / Rcf (Xg): 15000 Rpm /22388 G(Rpm And Rcf Varies As Per Rotor) Motor Type: Brushless Dc Display: Digital Display Timer Setting: 30 Sec To 999 Mins & Infinite Mode Lid Lock Safety: Yes Imbalance Detection: Yes Adjustable Ramp & Brake: Yes (Selection From 1 To 9) Rotors: Multiple Rotor Options. Fixed Angle Rotor 24 X 2 Ml (Included) Features: • Auto Rotor Detection Feature • Max Capacity 4 X 100 Ml (Swing Out & Fixed Rotor) • Maximum Tube Capacity 32 X 6 Ml (Swing Out) • Variable Speed From 500 To 15000 Rpm • Brushless Dc Motor For Maintenance-Free Long Life • Microprocessor Controlled Centrifuge With Variable Speed And Time Setting And Also With Last Run Memory Function • Single Equipment For Different Work Protocols With An Appropriate Choice Of Rotors (Swing And Fixed Angle) • Imbalance Detection And Lid Lock Safety Feature • Large Back-Lit Lcd Display For Easy Setting & Reading Of Multiple Parameters (Speed & Time) • Adjustable Ramp & Brake Speeds From (Up To 9 Speed Selection) • User-Programmable (User Can Set Up To 99 Programs With 4 Line Programs) , Thermal Cycler Thermal Cycler With High-Uv Max Transilluminator X Quantity 1 Each Technical Specification: 1. System Should Have Touch Screen Interface Anodized Aluminum Block System With Capacity To Accommodate 0.2Ml Pcr Strips, Tubes, And Semi-Skirted, Non-Skirted 96 Well Pcr Plates. 2. Heating Of The Thermocycler Block Should Be Through Six Peltier Elements. 3. Interchangeable Block Facility Should Be Available With 48X2 Well Block, 32X3 Well Block, 384 Well Block And 96-2D Well Block (2-Dimensional Gradient) Options. 4. Should Have Gradient Feature. User Can Define The In Each Zone. The Block Should Have 6 Zone. The Ramp Rates Must Be Identical In Both Gradient And Normal Operation. 5. The Temperature Of The Instrument Should Be Within The Range Of 0-100°C. 6. The System Should Have A 6°C/Sec Heating Ramp Rate And 5°C/Sec Cooling Ramp Rate. 7. Fast And Standard Temperature Control Modes Are Must. 8. Lid Temperature Range: 37 - 110 °C. 9. System Should Have Block Temperature Accuracy: ± 0.1°C; Block Homogeneity: ±0.25° C 10. Adjustable Ramp Rate Individually For Heating & Cooling From 0.1 ° C To Meet Critical Amplification Conditions. 11. Customized Programming Should Allow A Maximum Of 40 Steps And 200 Cycles. Should Be Capable Of Time Or Temperature Increment With Cycles In Pcr Program. 12. Lid Descent And Closing Pressure Must Be Flexible To Accommodate Pcr Tubes With Flat Or Domed Caps. 13. Should Have Thermal Sample Protection To Maintain The Block At Lower Sub-Optimal Temperature Until The Lid Reaches The Desired Temperature To Avoid Non-Specific Amplification. 14. System Should Have One-Click Quick Incubation Function Can Meet Experiments Needs Such As Denaturation, Enzyme Cutting/Enzyme-Link And Elisa 15. Should Have Cooling Vents At Front And Rear To Make Limited Footprint In The Compact Lab Setting. 16. Email Notification, Log Book Function For Error Messages Are Must. 17. Should Have Program Migration Feature For Easy Transfer Of Protocols From Other Thermocyclers. 18. Should Have 10.1-Inch Intuitive Larger Graphic Display, Administrator And User Login With Pin Or Password For Enhanced Security. 19. A Large Display Interface Should Be Required For Viewing The Status Of The Instrument. 20. The Instrument Should Have A Usb Flash Extension For Saving Protocols, With A Capacity Of 20000. 21. System Should Have Auto Restart Facility On The Event Of Power Failure. 22. Power Consumption Should Not Exceed 600W. 23. System Should Have Ce And Iso Certification. Hi-Uv Max Transilluminator: 1. System Must Have Uv Source Of Wavelength 312Nm (Best For Dna, Rna) 2. System Must Have 5X6W High Intensity Uv Tubes Are Used. 3. System Must Have In Built Self Timer To Prevent Overexposure Of Gel To Uv Preventing Dna Mutagenesis And Loss Of Intensity On Gel. 4. System Should Be Highly Sensitive & Able To Detect Weak Band With Low Concentration. 5. System Must Have Long-Life, Pure-Uv Quartz Filter. 6. System Should Have Highly Polished Reflectors For Uniform Illumination. 7. System Must Have High Contrast Filter To Eliminate Leakage From Fluorescent Lamp. 8. System Should Be Light In Weight. Approx. 3 Kg. 9. System Should Have View Area Is 15X15Cm So That Maximum Of 15X15Cm Gels Can Be Used. 10. System Must Resists Most Chemicals, Minor Scratches, Polarization. 11. System Should Have Instant Start, No Humming, Low Heat & Cooling Fan For Air Circulation.
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
TodayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender