Tender For Replacement Of Existing Fire Alarm System And Provision Of Pa System In Auditorium Hall At Post Graduate Govt. College For Girls, Sector-42, Chandigarh.
Tender Value
17.08 Lakhs
Estimated cost
Bid Submission
02 Sep 2026
8 days left
EMD
34175
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Replacement Of Existing Fire Alarm System And Provision Of Pa System In Auditorium Hall At Post Graduate Govt. College For Girls, Sector-42, Chandigarh.
BOQ
| Sl. No. | Item Description |
| 1 | DSR item No. 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 2 | 20 mm |
| 3 | DSR item No. 28.2.1 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. (Please refer DNIT for complete specification of item no.2) |
| 4 | Two Loop Panel. |
| 5 | DSR item No. 28.2.4 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 6 | DSR item No. 28.2.6 Supplying, installation, testing & commissioning of intelligent addressable programmable sounder complete as required. |
| 7 | DSR item No. 28.2.12 Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or separate) complete with emitter and receiver including connections with remote test features etc complete as required. |
| 8 | DSR item No. 28.2.14 Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 9 | DSR item No. 28.3.3 Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. |
| 10 | DSR item No. 28.5.1 Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. |
| 11 | DSR item No. 28.5.3 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. |
| 12 | speaker cable Single pair, 2-core, 1.5 sqmm |
| 13 | DSR item No. 39.23 Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. |
| 14 | 15U Rack |
| 15 | Supply and installation of Red/ Green LED Laser etched emergency exit signage‘s double sided pendant type made out of powder coated MS housing and etched acrylic sheet indicator with reflective light source> 2W LED, Emergency Backup of minimum 4 hours, 6V 3.2 AH SMF/ SLA battery, SMPS Power supply suitable for operation on 230 AV 50 Hz AC supply as per the requirement at all prominent locations to guide the way out of the building to the building users in case of fire. The size of the letter should be sufficient for visibility of the people as per NBC-2016. The exit sign board should be of THORN/ PROLITE/ AUTO GLOW/ AUTOLITE/ GLOWLITE/ HONEYWELL make only. |
| 16 | Supplying, installation, testing & commissioning of 240 Watts Mixer amplifier, Inbuilt Bluetooth for audio streaming, Supports audio playback from USB pen drive, 4 microphone/line inputs, plus music source input, Insert feature to use as a pre/power amplifier, Optional 2 tone chime generation for input 1, Frequency response 80 Hz to 18 kHz (+1/3 dB @ 10 dB ref. rated output), Distorsion- <1% @ rated output power, 1 kHz, Bass Control - Max. + 8 dB, Treble Control - Max. ± 8 dB Connector - Cinch, stereo converted to mono, Sensitivity - 200 mV to 300 mV, Impedance - 22 kohm, S/N (flat at max. volume) - ≥70 dB, Headroom ->25 dB Make: Bosch / Crown /Honeywell/ Bose only. |
| 17 | Supply, installation, testing and commissioning of 2x10 watt wall/ceiling mounted industrial Double Beam emergency LED light with exit sign board. The fitting should have CRCA steel housing, 5700K color Temperature, 50000 burning hours, minimum emergency backup of 4 to 5 hours. The fitting should be fully automatic i.e. automatic on in case of normal supply failure and automatic off as power resumes. The battery should have inbuilt protection for over, under charge and short circuit protection. The job also includes the cost of testing commissioning and making connections with 3x1.5 copper conductor from adjacent light point, other petty material and labour etc. as required to complete the job to be entire satisfaction of Engineer-in-Charge. Make: Mr. Lite/ Agni/ Edvent only. |
| 18 | Supplying, Installation, Testing & Commissioning of Tabletop Unidirectional Condenser Microphone Voltage range 12 to 48 V Current consumption <8 mA sensitivity 0.7 dB SPL, distortion <0.6% (maximum input) Input noise (equiv.) 28 dB SPLA (S/N 66 dBA ref. 1 Pa), Frequency response 100 Hz to 16 kHz output impedance 200 ohm Make: Bosch/Sennheiser/Shure only. |
| 19 | The Annual Maintenance Contract (AMC) for complete fire alarm system shall be on a comprehensive basis, including maintenance of the complete system along with all necessary spare parts, and no additional or hidden charges shall be payable during the contract period. Preventive maintenance of the system shall be carried out once every fortnight to ensure proper functioning. The supplier shall attend all service/repair calls within two (2) hours from the time of lodging the complaint, and all defective equipment shall be repaired on the same day at the purchaser’s site. (Please refer DNIT for complete specification of item no.15) |
| 20 | 2nd year |
| 21 | 3rd year |
| 22 | 4th year |
| 23 | 5th year Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysSep 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender