Tender For Comprehensive Maintenance Of Internal Wiring And Fiting Fixtures At Pocket No 2 (Units) To 4 And 16 To 21 Under Ge (A) Jaisalmer
Tender Overview
Project Description
Tender for Comprehensive Maintenance Of Internal Wiring And Fiting Fixtures At Pocket No 2 (Units) To 4 And 16 To 21 Under Ge (A) Jaisalmer
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Sep-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 28-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully aluminium point wiring (light, fan socket or power) complete including PVC Casing Capping/concealed conduit, fixture and fitting such as switches, ceiling roses, pendents, regulators, sockets , light fitting etc removing materials for taking credit and making good disturbed surface of walls,floors etc all as directed. |
| 2 | Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes all as specified. |
| 3 | Taking down the existing unserviceable MCBs/MCCBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes all as specified. |
| 4 | M&L for point wiring using approved colour coding as per IS with multistranded copper conductor 1.5 sq mm nominal cross-sectional area (two runs i:e phase and nuetral) , single core, PVC insulated and unsheathed FRLSH cable 1100 Volts grade, ISI-694 ,with medium grade PVC casing caping/surface conduit and accessories on wall/roof/floor etc, ISI marked with mild steel/pressed steel modular metal flush box thickness as per OEM standard (with earth dolly) duly painted with two coats of anti corrosive paint/galvanised paint,covered modular cover plate for fixing of switches, socket and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-charge for One light or fan point, controlled by one, one way switch 5 Amps. |
| 5 | All as per Item No .04 here-in-before but for one bell/buzzer point controlled by one push botton. |
| 6 | All as per Item No. 4.00 here-in-before but for one light point controlled by two, 2 way switches. |
| 7 | All as per Item No 4.00 here-in-before but for one socket out let 3 pin 5 Amps on the same board. |
| 8 | All as per Item No. 4.00 here-in-before but for one socket outlet of 3 pin 5 Amp on independent board. |
| 9 | All as per Item No 4.00 here-in-before but for one socket outlet of 15 Amps fixed on independent board with 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated and 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated as earth wire complete all as specified. |
| 10 | M&L for point wiring using approved colour coding as per IS,with two runs (Phase and nuetral) of multistranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 Volts grade, ISI-694 through existing PVC Concealed conduit of suitable size with accessories in wall floor etc with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-charge for One light or fan point, controlled by one, one way switch 5 Amps. |
| 11 | All as per Item No 10.00 here-in-before but for one bell/buzzer point controlled by one push botton. |
| 12 | All as per Item No. 10.00 here-in-before but for one light point controlled by two, 2 way switches. |
| 13 | all as per Item No 10.00 here-in-before but for one socket out let 3 pin 5 Amps on the same board. |
| 14 | all as per Item No. 10.00 here-in-before but for one socket outlet of 3 pin 5 Amp on independent board. |
| 15 | All as per Item No 10.00 here-in-before but for one socket outlet of 15 Amps fixed on independent board with 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated and 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated as earth wire complete all as specified and directed by Engineer-in-charge. |
| 16 | M&L Point wiring used approved colour coding as per IS , with two runs (phase and nuetral) of multi-stranded copper conductor 1.5 sqmm nominal cross -sectional area, single core, PVC insulated and unsheated FRLSH cable 1100 volts grade, ISI 694 and medium grade PVC Concealed conduit & necessary wall cutting including medium grade PVC concealed conduit MMS, ISI marked of dia not less than 20 mm and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No. (IS-9537 - 1983 for condits and IS : 3419 - 1976 for conduit accessories) with terminated to new pressed flush metal boxes readily available cover with outer plates inner plates et, suitable for mounting modular type switches, socket fan regulator etc , PVC insulated multistanded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engr in charge for the light/fan point, controlled by one way switch 5 amps.Note : Modular switch and socket shall be measured and paid separately. |
| 17 | All as per Item No 16.00 here-in-before but for one bell/buzzer point controlled by one push botton. |
| 18 | All as per Item No. 16.00 here-in-before but for one light point controlled by two, 2 way switches. |
| 19 | All as per Item No 16.00 here-in-before but for one socket out let 3 pin 5 Amps on the same board. |
| 20 | All as per Item No. 16.00 here-in-before but for one socket outlet of 3 pin 5 Amp on independent board. |
| 21 | All as per Item No 16.00 here-in-before but for one socket outlet of 15 Amps fixed on independent board with 4.0 Sq mm multistranded copper conductor wire FRLSH PVC insulated and 4.0 Sq mm multistranded copper conductor wire FRLSH PVC insulated as earth wire complete all as specified and directed by Engineer-in-charge. |
| 22 | S&F in repair of Switch modular 06 A 01 module , one way as per existing pattern complete all as specified and directed by Engr-In-Charge. |
| 23 | S&F in repair of modular Bell push 06 Amps 1 module as per existing pattern complete all as specified and directed by Engr-In-Charge. |
| 24 | S&F in repair of of modular Socket outlet, multi purpose, 06 Amps 3 pin combined 2 module as per existing pattern complete all as specified and directed by Engr-In-Charge. |
| 25 | S&F ir repair of modular Switch 16 Amps one way 1 module as per existing pattern complete all as specified and directed by Engr-In-Charge. |
| 26 | S&F in repair of modular Socket 16 Amps, 5 pin combined 2 module as per existing pattern complete all as specified and directed by Engr-In-Charge. |
| 27 | S&F in repair of Switch modular 06 Amps two way, 1 module as per existing pattern complete all as specified and directed by Engr-In-Charge. |
| 28 | S&F in repair of modular fan regulator 5 step type, 2 module, 120watt as per existing pattern complete all as specified and directed by Engr-In-Charge. |
| 29 | M&L in repair of lamp holder, PVC/ polycarbonate type with back plate suitable for batten fittings including taking down unserviceable lamp holder of any description complete all as specified. |
| 30 | S&F of ceiling rose, PVC of size 65 mm x 18 mm two to three terminals (ISI marked) all as specified. |
| 31 | S&F in repair of bell AC single pole Ding Dong type 230 volt all as specified. |
| 32 | M&L for submain wiring with approved colour code/as per IS with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 Sq mm (FRLSH) in and including PVC casing & caping/Conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 6.0 Sq mm (FRLSH) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. (NOTE: Three runs of 6.0 sqmm cable & One run of medium grade PVC casing & caping/Conduit shall be paid as one unit length.) |
| 33 | M&L for submain wiring with approved colour code/as per IS circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 Sqmm (FRLSH) in existing concealed /surface conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 6.0 Sqmm (FRLSH) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge.(NOTE: Three runs of 6.0 Sqmm cable shall be paid as one unit length.) |
| 34 | M&L for submain wiring with approved colour code/as per IS with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 Sqmm (FRLSH) in through incl concealed conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 6.0 Sqmm (FRLSH) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge.(NOTE: Three runs of 6.0 Sqmm cable , one run of medium grade PVC conduit and necessary wall cutting/making good surface after wall cutting shall be paid as one unit length.) |
| 35 | M&L for submain wiring with approved colour code/as per IS with four single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 Sq mm (FRLSH) including surface/ concealed PVC conduit non metallic and wall cutting including one run of PVC insulated multistranded copper conductor nominal cross section area of 6.0 Sq mm (FRLSH) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. (NOTE: Five runs of 6.0 sqmm cable ,One run of PVC conduit & necessary wall cutting shall be paid as one unit length.) |
| 36 | M&L for submain wiring with approved colour code/as per IS with four single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 Sq mm (FRLSH) in existing PVC concealed conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 6.0 Sq mm (FRLSH) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. (NOTE: Five runs of 6.0 sqmm cable shall be paid as one unit length.) |
| 37 | M&L for submain wiring with approved colour code/as per IS with four single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 10.0 Sq mm (FRLSH) including surface/ concealed PVC conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 10.0 Sq mm (FRLSH) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. (NOTE: Five runs of 10.0 sqmm cable , One run of medium grade PVC conduit & necessary wall cutting shall be paid as one unit length.) |
| 38 | Supply and fixing of LED box type Integrated Batten Wattage 20 watt having Aluminum Extruded housing in white powder coated Finish with high translucent PC Cover, Dimension of the Fixture Must not be less Then Length 1170 MM (± 5 MM ), Elegant Design, IP 20 Protection. Minimum Lumens output of the fitting shall be 2500 Lumens With Efficacy of 125 lm/W, CCT 5700 – 6500K, Surge Protector 4 KV, PF>= 0.95 , Necessary mounting arrangements. The Manufacturer of the fixture shall have in house NABL Accredited Lab and must produce certificate of the same along with LM-79 / LM-80 / Test Report. |
| 39 | Supply and fixing of LED box type Integrated Batten 40 watt having Aluminum Extruded housing in white powder coated Finish with high translucent PC Cover, Elegant Design, IP 20 Protection. Dimensions of the Fitting Shall be Not less then 1200 MM ( Length) X 40 MM ( Width ) X 63 MM ( Height ). Lumens output of the fitting shall be not less then 4400 lm, CCT 5700 – 6500K, buring hours 50,000 Surge Protector 4 KV, PF>= 0.95 , Separate detachable type Electronic constant current drivers for easy replacement and maintenance, THD < 10% , Necessary mounting arrangements .The fixture shall be suitable for wall mounting /suspension mounting as per site requirement . The Manufacturer of the fixture shall have in house NABL Accredited Lab and must produce certificate of the same along with LM-79 / LM80 / Test Report . |
| 40 | S & F for LED tube light fitting 10 Watt, 2 Feet length, IP 20 Protection, wall mounted type, Slim LED Batten with extruded aluminium housing and polycarbonate diffuser, elegant design with end caps, having excellent thermally managed polycarbonate extrution, LM 80 Certified LED having Integral Electronic Constant Current Driver, IP 20 Protection, Opreating voltage 240 V , 50Hz AC Supply and Operating tempraeture 0 to 50 C, Power factor ≥ 0.9, Lumen output ≥ 1000, necessary mounting arrangements on PVC Square box 2 Nos, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white color flexible pipe complete all as specified. |
| 41 | Supply and fixing of recessed/ceiling/surface/POP mounted down lighter with high bright LED,idealy suited for low ceiling areas 36 watt LED (100 Lumen/watt or higher) , size 2ft x 2ft, 4500 K to 6500 K, necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white color flexible pipe complete all as specified. |
| 42 | S & F for LED downlight recessed/ceiling/surface/POP mounted luminare round type 18 watts with inbult driver and aluminium pressure die -cast housing with heat dissipating fins for larger surface area finished in epoxy powder coated white to driver high efficiancy light output and uniformity ,utilising edge lit technology and white finish operating voltage 230V AC, 50 Hz all as directed by Engineer- in-charge. |
| 43 | S&F in repair/replacement wall mounted decoration lights ,01 light opal glasswith chrome finish wall lamp,E14 LED 4.5WX1, including driling of wall ,fitting of light on the wall with necessary accessories all as specified and directed by engr in charge . |
| 44 | S&F in repair/replacement wall mounted decoration lights ,02 light opal glasswith chrome finish wall lamp,E14 LED 4.5WX 2, including driling of wall ,fitting of light on the wall with necessary accessories all as specified and directed by engr in charge .Make :-Make:- Philips/Havells/Bajaj |
| 45 | Supply & fixing in replacement of 05 mtr,2 Amp LED flexible strip use high brightness SMD LED as light source and high quality temp. resistant FPCB, Voltage DC 12 V color R/Y/B/G/P/W/WW including suitable electronic driver 2 amp complete all as specified and directed by Engr in Charge.. Make:- Philips/Havells/Bajaj |
| 46 | Supply and fixing LED building security light fitting 15 Watt (or above) 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with electronic driver including thermal management in multiple optics complete with IP 65/66 protection complete with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as directed by Engineer-in-Charge. |
| 47 | S&F Integral decorative LED bollard with polycarbonate diffuser square shaped with IP 65 protection suitable for 10 watts LED & height of light 0.6 M ,with necessary MS base box made out of MS sheet of 2 mm thick of suitable size abbended in PCC 1:2:4 base, elecrical connections with adequate size including removal of old unserviceable one complete as all specified and as directed. |
| 48 | S & F for LED post top lantern/gate Light 40 watt light fitting made of die cast top housing must also be dia cast aluminium spigot housing with decarative acrylic diffuser with IP 65 protection complete with all accessories including removal of old unserviceable complete all as specified and directed. |
| 49 | S & F in repair of LED Bulb white E-27 , 9 Watt of complete all as specified and directed by Engg-in-charge. |
| 50 | S & F for Decorative wall mounted luminaire made out of polycarbonate with unbreakable globe suitable for LED bulb and including of LED bulb 15 watts complete all as specified and as directed. |
| 51 | S & F for MCCB DB VTPN 4 way 415 V double door IP 43 with provision for FP MCCB/Isolator/RCCB etc as incommer and SP/TP MCBs as out going complete prewired including Bus Bar etc suitable for operation on 415 volt 50 Hz AC supply complete all as specified and as directed. |
| 52 | S & F for sheet metal enclosure MCB DB TPN 4 way double door IP 43 with 200 Amps rated bus bar 415 volts double door with magnitic locking system complete all as specified and as directed. |
| 53 | S & F for sheet metal enclosure MCB SPN DB 12 way with 200 Amps rated bus bar 240 volts double door IP 43 with magnitic locking system complete all as specified and as directed. |
| 54 | S & F for sheet metal enclosure MCB SPN DB 8 way with 200 Amps rated bus bar 240 volts double door IP 43 with magnitic locking system complete all as specified and as directed. |
| 55 | S&F Sheet metal and neutral enclosure single pole with two pin and earth plug and socket single pole MCB 20 Amps 240 volts fixed complete all as specified and directed by Engg-in-charge. |
| 56 | S & F MCCB with microprocesssor release 4P 415 volts 16 KA suitable for fixing on VTPN DB of capacity 125 Amps,ICS=ICU with extended terminals complete all as specified. Note:- Suitable size and frame of MCCB required as per existing DBs at site. |
| 57 | S & F MCCB with microprocesssor release 4P 415 volts 16 KA suitable for fixing on VTPN DB of capacity 100 Amps,ICS=ICU with extended terminals complete all as specified. Note:- Suitable size and frame of MCCB required as per existing DBs at site. |
| 58 | Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of tripple pole and neutral rated capacity TPN 63 Amps to 100 Amp current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed. |
| 59 | Supply and fixing miniature circuit breaker (MCB) of single pole and neutral SPN 40 AMP to 63 AMP 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and as directed. |
| 60 | Supply and fixing miniature circuit breaker (MCB) of single pole SP 10-32 AMP 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and as directed. |
| 61 | Supply and laying of 1100 volts grade heavy duty service cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq.mm 2 Core including PVC conduit pipe nominal cross section in service connections Complete all as specified by Engineer-in-Charge. |
| 62 | M/L of PVC casing & caping of any type, size by means of saddles, clamps screwes to existing wall/ceiling and making good in all respect incl wiring inside all as shown specified and directed by Engr-in-Charge. |
| 63 | S&F in repair of modular white cover plate with frame inner and outer plates including the taking out and refixing of existing/new switches and sockets,regulators etc. for following sizes:- |
| 64 | 1 Module |
| 65 | (a) 2 modules |
| 66 | (b) 3 modules |
| 67 | (c) 4 modules |
| 68 | (d) 6 modules |
| 69 | (e) 8 modules |
| 70 | (f) 12 modules |
| 71 | S&F in repair of modular metal flush boxes including the taking out and refixing of existing/new switches and sockets,regulators etc.and inner and outer plates for following sizes:- |
| 72 | (a) 1/2 modules |
| 73 | (b) 3 modules |
| 74 | (c) 4 modules |
| 75 | (d) 6 modules |
| 76 | (e) 8 modules |
| 77 | (f) 12 modules |
| 78 | S&F of in repair plastic laminated bakelite sheet cover of hylem 2.8 mm thick including cutting holes for switches, sockets etc as pre requirement including fixing with brass machine screws and washer complete of following sizes:- |
| 79 | (a) 10\\" x 12\\" size |
| 80 | (b) 8\\" x 10\\" size |
| 81 | (c) 8\\" x 6\\" size |
| 82 | (d) 7\\" x 4\\" size |
| 83 | (e) 4\\" x 4\\" size |
| 84 | Supply and fix energy saving, environment friendly & robust Highbay/Mediumbay roof truss light LED for covered shed 150 W IP66 luminaire with high efficacy with fixing arrangement such as bracket,MS clamp,Nut bolts etc and connecting completed as specified and directed. Note:- Fixing of light at any height arrangement of ladder should be provided by contractor. |
| 85 | Supply and fix energy saving, environment friendly & robust integrated well glass luminarie with die cast canopy&gear housing for covered shed 70 W IP66 luminaire with high efficacy with fixing arrangement such as bracket,MS clamp,Nut bolts etc and connecting completed as specified and directed. Note:- Fixing of light at any height arrangement of ladder should be provided by contractor. |
| 86 | M & L repair of bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to 4.00 mm dia GI wire as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 15 mm dia light grade pipe for earth lead protection connected to electrical equipment and earthing test point , earth dolly and earth chamber as shown in elect plate No 2 of SSR Pt-I including all necessary earth work, excavation, earth chamber with PCC 1:3:6, Type C1 and RCC chamber cover of PCC 1:2:4 with handle , funnel and wire mesh etc and testing on complete all as specified and directed Engr-in-Charge. |
| 87 | M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to DBs or any other indicated situation for loop earthing with 4.00 mm dia GI wire size complete all as specified and directed Engg-in-Charge. |
| 88 | M&L for GI Tubing light grade 15 mm dia.for cable protection complete all as specified and directed Engg-in-Charge. |
| 89 | M&L for rectification of No light for LT single / Three phase electric supply complaint in Main SPN /TPN/VTPN DB's & LT Bus Bar / junction Boxes in Zone-I under GE(A) Jaisalmerby by identifying the defects with required all Tools and safety gears & restore the continuity of supply within 3 hours from handing over the complaints & submit complaint slip duly signed by user rep not less than NCO rank & after rectifying the defects, the complaint slip handover to JE E/M. Note- (i) Complaints of No light must be attend in round the clock including Sundays & holidays. ii) Necessary transport or moving charges with T&P rates deemed to be included in quoted rates.iii) Contractor will arrange electrical tools, folding ladder, misc item like insulation tape, screws, nuts and bolts for repair work.(iv) In case the defect is not rectified within the given time, an amount of Rs 500/- per complaint shall be recovered from the contractor during RAR / Final Bill.(v) Register of repair should be prepared by the contractor and details of repair to be updated in the register after completion of every work duly signed by user and JE E/M for payment purpose. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender