Project Description

Tender for Renovation Of M.S. Srir Ur Under Topchanchi Block, Dist. Dhanbad.

BOQ

Name of Work:- Renovation of M.S. Srir ur Under Topchanchi Block, Dist. Dhanbad.
Sl. No. Item Description
1Earth work in excavation in foundation trenches in ordinary soil(vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, Extra for earthwork in hard soil as per specification and direction of E/I.
2Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
3Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
4Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I.
5Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building -do-.
6Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
7Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)
8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)
9Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level.1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
10Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
11Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
12Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
13Reinforded cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:15:3 cement: 1.5 coarsesand(zone-l):3 graded stone aggregate 20 mmnominal size).
14Reinforded cement concrete work in wals (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, Columns pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering& finishing and reinforcement : 1:1.5:3cement: 1.5
15Providing designation 75B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15 mm depth curing -do-.
16Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes -do-.
17Providing 12 mm thick water proof CEMENT PLASTER (1:3)on with clean coarse sand of F.M.1.5 and 5% cico including cost of screening, curing making grooves with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I .(Cost of cico will be paid separately)
18Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scafolding taxes and royalty all complete as per buildings specification and direction of E/I.
19Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I
20Providing 12mm, cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening , curing with all leads and lifts of water , scaffholding taxes and all complete as per building specification and direction of E/I & Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I.
21Providing 12mm thick cement plaster (1:4) with clean coarse sand of F.M 1.5 including screening curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.+Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I.
22Providing 1.5mm thick cement punning including curing, etc. complete job as per specification and direction of E/I.
23Providing and laying 6mm precast white glazed glazed tiles in wall over 12mm cement motar (1:3) and jointed with grey cement slurry flushed pointed with a grade white 15x15 cm TILES
24Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips do…………. Do…….. All complete job
25Supply XLPE/PVC insulated aluminium conductor armoured cable 1100 V grade with ISI Mark three core solid/ standard aluminium conductor with 6mm thick 25 mm width ms spacer with GI earth wire 6 sqmm complete in approved manner as per IS 7098 3.5 core 25 sqmm
26Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
27Providing 150 mm wide BRICK DRAIN in cement mortar (1:6) with avarage 150mm. Clear depth and 125 mm apron including cost of earthwork involved with 75m cement concrete (1:4:3) over one brick designation 75A, flat soling in proper grade and slope at the base , the drain dully plastered in C.M.(1:3) with puning over exposed surface all complete as per building specification and direction of E/I.
28Providing and laying polished VITRIFIED FLOOR TILES in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and confirming to IS : 15622 of approved make in all colors and shades laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand) including grouting the joints with cement and matching pigments etc. complete.Size of Tile 600 x 600 mm
29Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flats as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, hoisting carriage of grill to work site, hoisting as per building specific-do-.
30Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite stone slab colour black, Cherry/Ruby red
31Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners,all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angles 40x40x6 mm for diagonal braces
32providing and fixing hand rail of approved size by welding etc. to steel lader railing balcony railing ,staircase railing and similar work including applying prime coat of approved steel primer.
33Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete
34Providing and fixing pressed steel door frames conferming to IS 4351 menufactured from merical mild steel sheet of 1.60mm thick, including inges jamb,bead and if required angle thresold of mild steel angle of section 25mm or base tie of 1.60mm pressed mild steel welded or rigidly fixed together by mechanical eans ---do ---do --- all complete as per approved drawing, DSR specification and direction of E/I.
35Supplying Fitting Fixing Collapsible Gate of Approved Size and make …do…do…as per Building Specification and Dir of E/I.
36Supplying fitting and fixing 20 gauge G.C.I. Sheet gate fitted on M.S. Angle frame of size 60x60x6mm. Including cost of fabrication providing necessary locking arrangement with Haskell and downy duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction E/I.
37Labour for fabricating erecting hoisting and fixing in position structural steel work in RS Joist channel angel tee flat plate latice member built up to compound section do……..do……. All complete jobMS Angel 50x50x4
38Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete.
39Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.
40Providing two Coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new suface including preparing plastered sufaçe by rubbing smoóth with pumsicestone or fine sand papér, applying puty wherever required scaffolding washing of fobt and taxes all complete as per building specification anddieotion of E/I.
41Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/l.
42Supply of 50x50x6mm size angle for choukhat inwindow
43Finishing wall with acrylic smooth exterior paint of requird shade :13.46.1 new work (Tow of more coat applied @1.67/ltr/10sqm over and including priming coat of exterior primer applied @2.20kg/10sqm
44Providing and laying APP (Atactic Polypropylene Polymer) modifiedprefabricated five layer 3 mm thick water proofing membrane, black finishedreinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemicalparameters of the membrane shall be as under : Joint strength in longitudinaland transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinaland transverse direction as 300/250N. Softening point of membrane not lessthan 150°C. Cold flexibility shall be upto -2°C when tested in accordance withASTM, D - 5147. The laying of membrane shall be got done through the authorisedapplicator of the manufacturer of membrane :
45Providing two coat of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface throughly, scaffolding and taxes all complete as per specification and direction of E/I and Providing primer one coat or red lead paint of approved makeover new steel surface -do--
46Providing two coat of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface throughly, scaffolding and taxes all complete as per specification and direction of E/I and Providing primer one coat or red lead paint of approved makeover new steel surface -do--
47Providing and fixing fan hook of 16mm dia M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab beam at the time of casting all complete as per building specification and direction of E/I.
48providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL)
49Providing Tor steel reinforcement of rods as per approved design and drawing including carriage of Rods (straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust,-do-
50Providing Tor steel reinforcement of rods as per approved design and drawing including carriage of Rods (straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust,-do-
51Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittingswith one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Excluding GST) 15 mm nominal outer dia Pipes
52Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
53Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
54Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers
55Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
56Weather shade, Chajjas, corbels etc., including edges
57Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'p' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S equivalent make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixed a pair of vitreous white glazed earthenware ware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450 mm. long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I. 580 mm. long With 10 lit. low level PVC Cistem
58Supplying, fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S approved make supported on painted C.I. or R.S. brackets 32mm C.I. brass waste, 15mm dia C.I. body spindle stop cock of approved quality of weight not less than 350grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
59Making hole in wall of 250mm and rescoring the same 12mm dia.
60Providing and fixing C.P. brass bib cock of approved conforming to IS 8931.
61Providing And fixing 32 mm waste pipe for sink or wash basin including P.V.C. waste fittings complete.
62Providing and fixing C.P brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
63Providing and fixing C.P. brass Stop Cock (concealed) of standard designand of approved make conforming to IS 8931 15mm nominal bore, approved brand C.P. fittings.
64Providing and fixing C.P Soap Dish Holder having length of 138 mm breadth 102 mm, height of 75mm with concealed fitting arrangements, weighing not less than 110 gms.
65Providing and fixing PTMT extension nipple for water tank pipe,fitting or approved quality and colour. 15 mm nominal bore weighing not less than 32 gms
66Supplying and fixing of following way three pole & neutral, sheet steel , MCB distribution board 240 volts, on surface /recess , complete with tinned copper bushbars ,neutral busbar, earth bar , din bar ,detachable gland plate , interconnections ,phosphatized and powder painted including earthing etc. as requried. (but without MCB/RCCB/ISOLATOR) 4 way (4+12), single door horizontal type
67S-F- C series MCB 6/32/Amps single pole
68Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
69Providing & Fixing Brass /CI Stop Cork Of approved quality (d) 32 mm Dia
70Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
71Providing and fixing CPVC pipes do……..do…… all complete job. Exposed on Wall20 mm nominal outer dia Pipes
7232 mm nominal outer dia Pipes
73Conselled 15mm dia
74Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
75Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single pushfit Coupler 110 mm
76Single tee with door 110x110x110 mm
77Bend 87.5° 110 mm bend
78Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI :12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
79FR PVC Insulated 3 Core 4 Sqmm copper wire
80Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion(75 mm diameter)
81Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion(110 mm diameter)
82Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
83Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.Group C
84Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
85Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
86Supplying of Fan
87Wiring for light/point/Exhaust fan point/call bell point with 1.5 sq.mm FRPVC insulated copper conductor cable in surface/recessed PVC conducit as required. With piano type switch phenolic laminated sheet MS Box earthing the point PVC insulated copper 1.5 Sq.mm FR PVC insulated copper conductor single core cable etc. at required.1.1.3 Group C
88Supplying and fixing kfollowing piano tpe switch/socket on the existing switch box/cover including connections etc as required 1.23.4:- 5/6 amps soclet outlet
89Supplying and fixing kfollowing piano tpe switch/socket on the existing switch box/cover including connections etc as required 1.23.4:- 5/6 amps soclet outlet
90Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor single core cable in surface/racessed PVC conduit as required.1.7.2 :- 2x2.5 sqmm+1x2.5sqmm earth wire
91Supplying and fixing PVC/G.I. box of 210mm x206 mmx48mm deep on (nominal size (10''x12'')) surface/recessed with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 amp and 15/16 ampsocket outlet and 15/16 amp piano type switch connection etc as required.
92S/F Modular boxes, base & cover plate :-Supplying and fixing following size / modules , GI box along with modularbase & cover plate for modular switches in recess etc as required. I or 2 module (78mmx 78mmx 45mm)
93S/F Modular boxes, base & cover plate :-Supplying and fixing following size / modules , GI box along with modularbase & cover plate for modular switches in recess etc as required. 8/9 module (78mm x 230mm x 60mm)
94S/F Modular boxes, base & cover plate :-Supplying and fixing following size / modules , GI box along with modularbase & cover plate for modular switches in recess etc as required.l2 module (l35mm x 205mm x 60mm)
95S/F Panel mounted TP & N in cubical panel board -Providing and fixing 100 amp TP & N disconnector fuse switch unit inside the existing panel board.
96S/F 3 pin, 5Amp celling rose on the existing junction Box/wooden block including connection etc as required.
97S/F Bitten Holder encluding connection Do - -do-
98ITC exhaust fan upto 450mm sweep
99Providing and fixing following capacity 2 pole/ 4 pole ON/OFF-Load change over switches with side handle operation , in sheet enclosure in existing metal board including drilling holes in metal board , making connection, earthing the body etc. as required.32 amps,2pole
100S/F Panel mounted changeover :-Providing and fixing following capacity 4 pole ONJoad panel mountedchangeover switches in existing cubical panel board, making connection,earthing the body etc. as required.100 amps, 4 pole
101S/F S.P MCB DB:-Supplying and fixing following way single pole and neutral sheet steel MCB DB 240 volts on surface/recess complete with tinned copper bus bar neutral bus bar, earth bar, din bar including powder painted including earthing etc. as required.
102S/F 10/12 watt LED tubelight
103S.I.T.C of following raiting surface mounted LED tube light fitting suitable for 230 V50 Hz,single phase supply etc.complete as required. 20/22 W LED Tube light
104S/F Modular type switch/ socket :-Supplying and fixing of following modular switch / soket on the existingmodular plate & switch box including connections but excluding modularplate etc. as required.5/6 amps, one way switch
105S/F Modular type switch/ socket :-Supplying and fixing of following modular switch / soket on the existingmodular plate & switch box including connections but excluding modularplate etc. as required. 5/6 amps, three pin socket outlet
106S/F Modular type electronic fan regulator :-Supplying and fixing stepped type electronic fan regulator on the existingmodular plate & switch box including connections but excluding modularplate etc. as required.
107Supplying LED 10 Watt
108Supplying LED 15/16 Watt
109Supplying Exhaust Fan (15\\")
110Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig, air compressure and equipments as well as fule, lubricants and cost of transportation of rig machine annd other vehical up to Site. (a) From 0.00 M to 50.00 M below G.L.
111(b) From 51.0 M to125.00 M
112Supplying, assembling, lowering and fixing in vertical position in bore well, un-plasticized PVC medium well casing (CM) pipe of required dia, all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia.
113Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
114Supplying and commissionig of submersible pump set of reputed KSB/tTexmo make ISI, ISO 9001 marked or having ISO 9001-2000 submersible motor pump for HYDT & head of 100.00m having discharge 4000 l/hour and lowering mm dia PVC submersible schedule 80 pipe & 2.5 sq.mm size finolex copper cable about 80.00 m with main switch 32Amp & panel board sonsisting voltmeter ammeter, on/off switch HRC fuse unit and lighting arrangement, adobter, rope with all complete job as oer specification and direction of E/I1.5 HP
115Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS : 2800 (part I) including necessary bolts & nuts of requried size complete. 200 mm clamp
116Supply fitting and fixing of standered make starter pannel board with arrangement of all necessary protection including all taxes royality etc. all complete job as per direction of E/I
117Supplying fitting and fizing 3 crore 4 sqmm flat copper submemersible cable Finolex/Hevels make including all taxes royality etc. al complete job as per direction of E/I
118CARRIAGE Cement
119Steel
120Stone Chips
121Stone Metal
122Bricks
123Goods & Service Tax (G.S.T.) -
124Labour Cess - Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57158866
AUTHORITY Government Departments
TENDER VALUE 68.80 Lakhs
LAST DATE 31-08-2026
Authority
Authority Name Rural Development Department
Work Description Tender for Renovation Of M.S. Srir Ur Under Topchanchi Block, Dist. Dhanbad.
Basic Detail
Tender No 24/2026-27/RDSD/EE/Dhanbad/Gr. 32
Bidding Type Tender
Location
City Dhanbad
State Jharkhand
Key Dates
Publish Date 24 Aug 2026
Submission Date 31 Aug 2026
Open Date 02 Sep 2026
Finance
Tender Value 68.80 Lakhs
Tender Fee 10000
EMD 1.38 Lakhs
Exemption Not Available
Document List
BOQ_159226.xls
fe8516b0-d6b0-4572-81c6-bc7cb5a00545.html
SBDNit24Gr32DoubelBid.pdf
Tendernotice_1 (19).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Sep 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_159226.xls

html

fe8516b0-d6b0-4572-81c6-bc7cb5a00545.html

pdf

SBDNit24Gr32DoubelBid.pdf

pdf

Tendernotice_1 (19).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders