Tender For Construction Of 4Acr Building And Renovation Of Kitchen And Toilet Of P.S. Narodih Under Govindpur Block In Dhanbad Dist.
Tender Value
52.13 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
1 days left
EMD
1.05 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dhanbad → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of 4Acr Building And Renovation Of Kitchen And Toilet Of P.S. Narodih Under Govindpur Block In Dhanbad Dist.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation in foundation trenches in ordinary soil(vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees,Extra for earthwork in hard soil as per specification and direction of E/I. |
| 2 | FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation of trenches within 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) |
| 3 | FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) |
| 4 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building -do-. |
| 5 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 6 | Providing P.C.C. M-150 with nominal mix of (1:2:4) in Foundation with approved quality of stone metal grade III (53 to 22.4 mm size) and clean coarse sand of F.M. 2.5 to 3 including screening,mixing cement concrete in mixture, placing in position, vibration, striking, curing, taxes and royalty all complete as per building specification & direction of E/I. |
| 7 | Providing R.C.C.M 200(1:1.5:3) in foundation and plinth with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, mixing cement concrete in mixer and placing in position, vibrating -do-. |
| 8 | Providing R.C.C.M 200(1:1.5:3) in beam of all types with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, mixing cement concrete in mixer and placing in position, vibrating, str |
| 9 | Providing R.C.C.M 200(1:1.5:3) in columns with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including screening , mixing cement concrete in mixer and placing in position, vibrating, striking, -do-. |
| 10 | Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 11 | Providing 50mm thick damp proof course with cement concrete M-150 with nominal mix of (1:2:4) with approved quality of stone chips of 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including screening, and mixing cement concrete -do-. |
| 12 | Providing desination 100 A brick work with flyin ash time brick (FLAG) conforming to IS 12894 - .-.i~ 1990 (9\\" x 4.s· x 3\\") in C.M. (1 : 6) in |
| 13 | Providing 19mm thick water proof CEMENT PLASTER (1:3)on with clean coarse sand of F.M.1.5 and 5% cico including cost of screening, curing making grooves with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I .(Cost of cico will be paid separately) |
| 14 | Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scafolding taxes and royalty all complete as per buildings specificationand direction of E/I. |
| 15 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 16 | Providing 25mm thick First Class patent stone flooring (1:2:4) with stone chips with two lears bottom layers 19mm thik (1:2:4) and top layers 6mm thick(1:2) with 6mm down stone chips……do….. |
| 17 | Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flats as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, hoisting carriage of grill to work site, hoisting as per building specific-do-. |
| 18 | Supplying Fitting Fixing Collapsible Gate of Approved Size and make …do…do…as per Building Specification and Dir of E/I. |
| 19 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 20 | Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size60X60X6mm. Including oost of fabrication, providing necessary locking arrangement~S.S.29 haskal and dolmy duly fixed in P.C.C. (1 :2:4) blocks of required size applying a priming red lead paint over steel ~ taxes al complete as per draMlQ specification and direction of E/1. |
| 21 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 22 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. |
| 23 | Finishing walls with Premium Acrylic Smooth exterior paint with silicone additives \\"Snowcryl - XT\\" of M/S Snowcem India Ltd, or equivalent of required shade.New work (Two or more coats applied @1.43 ltr / 10sqm. Over and including base coat of water proofing cement paint Snowcem Plus or equivalent applied @ 2.20 kg./10 sq.m. ) |
| 24 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 25 | Providing and fixing fan hook of 16mm dia M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab beam at the time of casting all complete as per building specification and direction of E/I. |
| 26 | Providing Tor steel reinforcement of rods as per approved design and drawing including carriage of Rods (straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust,-do- TMTC-500 8mm dia @30% |
| 27 | TMTC-500 10mm dia@30% |
| 28 | TMTC-500 12,16mm dia@40% |
| 29 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter 3mtr length |
| 30 | Providing and fixing wall face upvc fittings 110mm bend |
| 31 | 110 mm shoe |
| 32 | Shuttering in Foundation |
| 33 | Shuttering in Beam |
| 34 | Shuttering in Column |
| 35 | Shuttering in DPC |
| 36 | Shuttering in Chajja |
| 37 | Shuttering in Roof Slab |
| 38 | Shuttering in Stair Case |
| 39 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 40 | Providing 150 mm wide BRICK DRAIN in cement mortar (1:6) with avarage 150mm. Clear depth and 125 mm apron including cost of earthwork involved with 75m cement concrete (1:4:3) over one brick designation 75A, flat soling in proper grade and slope at the base , the drain dully plastered in C.M.(1:3) with puning over exposed surface all complete as per building specification and direction of E/I. |
| 41 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 42 | Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 43 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 44 | Providing and laying APP (Atactic Polypropylene Polymer) modifiedprefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemicalparameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : |
| 45 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite stone slab colour black, Cherry/Ruby red |
| 46 | Providing and laying double cherge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement @3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc.,complete. Size of Tile 600x600 mm |
| 47 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement motar (1:3)and joined with grey cement slurry with \\"A\\"grade white 15 X15cm tiles. |
| 48 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 49 | Providing and fixing chlorinated polyvinyl chloride (CPVC)pipes, having trermal stability for hot & cold water supply, including all CPVC plain & brass threaded fitting,i/c fixing the pipes with clamp at1.00m spacing.This includes jointing of pipes & fittings with one steps CPVC solvent cement and the cost of cutting chases and making good the same including testing ofd joints complete as per of derection of Engineer in charge. concealed work, including cutting chases and making good the wall etc. 18.8.1 15 mm nominal outer dia pipes |
| 50 | 18.8.2 20 mm nominal outer dia pipes |
| 51 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes |
| 52 | Providing and fixing brass/C.I.Stop cock of approved quality all complete as per specification and direction of E/I. (A) BRASS STOP COCK |
| 53 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore |
| 54 | S/F Batten / Angle Holder : Supplying and fixing batten / angle holder including connections etc. as required |
| 55 | Providing, fitting, fixing & testing of (Essential) LED Lamp 15/16W LED in existing Battan / Angle Holder (Make – Philips / Bajaj / Crompton / Wipro) |
| 56 | 2x1.5 sq mm +1 x 1.5sq mm earth wire. |
| 57 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 58 | Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. Approved make supported on painted C.I. Or R.S. Bracket 32mm C.I. Brass waste, 15 mm dia C.I. Body brass spindle stop cock of approved quality of weight not less than 350 grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plunber joints etc. all complete as per specification and direction of E/I. |
| 59 | Providing and fixing male ended C.P. Brass bib cock of approved quality conforming to IS 8931, 15 mm dia nominal bore of approved brand C.P. fitting all complete as per specification and direction of E/I. |
| 60 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 gms |
| 61 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 110 mm |
| 62 | Single tee with door 110x110x110 mm |
| 63 | Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I. (c) (i) C.P. Brass towel rail 20mmX600mm with bracket container |
| 64 | (b) Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. Brass revolving fitting 3mm ply wood board and C.P. Hinges to fix with mirror. (i) 600mm X 450mm size |
| 65 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 32 mm dia |
| 66 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig, air compressure and equipments as well as fule, lubricants and cost of transportation of rig machine annd other vehical up to Site. (a) From 0.00 M to 50.00 M below G.L. |
| 67 | (b) From 51.0 M to125.00 M |
| 68 | Supplying, assembling, lowering and fixing in vertical position in bore well, un-plasticized PVC medium well casing (CM) pipe of required dia, all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia. |
| 69 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge |
| 70 | Supplying and commissionig of submersible pump set of reputed KSB/tTexmo make ISI, ISO 9001 marked or having ISO 9001-2000 submersible motor pump for HYDT & head of 100.00m having discharge 4000 l/hour and lowering mm dia PVC submersible schedule 80 pipe & 2.5 sq.mm size finolex copper cable about 80.00 m with main switch 32Amp & panel board sonsisting voltmeter ammeter, on/off switch HRC fuse unit and lighting arrangement, adobter, rope with all complete job as oer specification and direction of E/I2.0 HP |
| 71 | Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS : 2800 (part I) including necessary bolts & nuts of requried size complete. 200 mm clamp |
| 72 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittingswith one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Excluding GST) 32 mm nominal outer dia Pipes |
| 73 | Supply fitting and fixing of standered make starter pannel board with arrangement of all necessary protection including all taxes royality etc. all complete job as per direction of E/I |
| 74 | FR PVC Insulated 3 Core 4 Sqmm copper wire |
| 75 | Polythene water storage tank of ISI Mark (e.g. Sintex/Sinter/Himgir/Gangotri etc.) with cover and locking system |
| 76 | Carriage of Materials : Sand Av. Lead 15 KmP |
| 77 | Chips Av. Lead 10 KmP |
| 78 | Cement Av. Lead 05 KmP |
| 79 | Steel Av. Lead 05 KmP |
| 80 | Bricks Av. Lead 10 KmP |
| 81 | Goods & Service Tax (G.S.T.) - |
| 82 | Labour Cess - Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 daySep 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender