Defence Statutory Bodies & Commissions/Committees Closing in 10 days TDR #57157489

Tender For special Repairs/ Replacement Of Lt Cable And Panel From Chanakya Colony To Soi At Mil Stn Dhrangadhra

Issued by Statutory Bodies & Commissions/Committees · Surendranagar, Gujarat
Tender Value
Ref. Documents
Estimated cost
Bid Submission
12 Sep 2026
10 days left
EMD
32000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Surendranagar → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repairs/ Replacement Of Lt Cable And Panel From Chanakya Colony To Soi At Mil Stn Dhrangadhra

BOQ

Name of Work:- SPL REPAIRS/ REPLACEMENT OF LT CABLE AND PANEL FROM CHANAKYA COLONY TO SOI AT MIL STN DHRANGADHRA
Sl. No. Item Description
1Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation of pole,laying of cables etc in Hard and dense soil and getting out complete all as specified and directed.
2Excavating in trenches not exceeding 1.5m wide and exceeding 1.5 m but not exceeding 3.00m in depth for foundation of pole, laying of cables etc in hard/dense soil and getting out complete all as specified and directed.
3Returning filling in including spreading, leveling, watering and well ramming in layer not exc 25 cm complete all as specified and directed.
4Removing excavated material not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
5M&L for providing dry river sand as in sand cushioning to UG cable including punning gently all as directed. Note : Depth after punning shall be measured and paid complete all as specified and directed.
6Dismantling old unserviceable Steel poles/Rcc poles/struts, any size complete all as specified and directed.
7M&L for plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundtion of PCC poles/struts all as specified and directed.
8M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundtion of pole/stay/PCC of road cutting assembly etc including necessary form work, all as specified and directed.
9M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for padestal/coping around poles, including necessary form work, finishing even and smooth without using extra cement, all as specified and directed.
10Taking out sub class burnt bricks from the trenches and stacking at site serviceable /unserviceable bricks for reuse complete all as specified and directed.
11Laying only sub class brunt bricks as cable protection cover all as directed.
12Supply and laying sub class old 'B' burnt bricks laid as cable protection cover complete all as specified and directed.
13M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws, type410 SP-22 (8.5 Mtr long) including two coats of bituminous paint internally and externally for the portion embedded in concrete and two coats of aluminium paint over one coat of red oxide primer to external/exposed surfaces complete all as specified and directed . Note:- (i) Excavation/PCC will be measured and paid separately under relevant items (ii) writing letters pole no and figures in white enamel of black Roman, Italic or Indian of 10 cm height including circular back ground with black enamel paint of two coats incl white circular border over steel
14S&F, in repairs, bracket made out of light grade, Galvanised steel tube, 35mm bore, 1.2 Mtr length, bent to 120 degree for fixing street light fitting at the top, fixed to pole with necessary clamps made out of FI 40mm x 4mm with nuts & bolts including preparation of steel surfaces & apply two coat of synthetic enamel paint over red oxide prime rincluding taking dowo old complete all as specified and directed.
15Supply and fix LT junction box for street light, FRP type with hinged type door and locking arrangement, off white colour, of size 300 x 200 x 105mm (internal) comprising of suitable size Aluminium busbar 3 rows with terminals,1 No bakelite base neutral link and 01 No earthing terminal bolt and nut and connecting up cables with aluminium terminal lugs all as specified and as directed .
16Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant including taking dowo old complete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete withIP 66 protection complete
17Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 6 sqmm x 2 core with glands, cable protection pipes etc., complete from the trenches/fixed on wall removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items all as per existing make
18Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 16 sqmm x 4 core with glands, cable protection pipes etc., complete from the trenches/fixed on wall removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items all as per existing make
19Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 50 sqmm x 3.5 core with glands, cable protection pipes etc., complete from the trenches/fixed on wall removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items all as per existing make
20Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 70 sqmm x 3.5 core with glands, cable protection pipes etc., complete from the trenches/fixed on wall removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items all as per existing make
21Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 95 sqmm x 3.5 core with glands, cable protection pipes etc., complete from the trenches/fixed on wall removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items all as per existing make
22Supplying & laying, XLPE insulated PVC inner sheathed, 6 Sqmm, 2 core, armoured with galvanised steel strip heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed.
23Supplying & laying, XLPE insulated PVC inner sheathed, 16 Sqmm, 4 core, armoured with galvanised steel strip heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed.
24Supplying & laying, XLPE insulated PVC inner sheathed, 50 Sqmm, 3.5 core, armoured with galvanised steel strip heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed.
25Supplying & laying, XLPE insulated PVC inner sheathed, 70 Sqmm, 3.5 core, armoured with galvanised steel strip heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed.
26Supplying & laying, XLPE insulated PVC inner sheathed, 95 Sqmm, 3.5 core, armoured with galvanised steel strip heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed.
27M&L, in repairs, earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth strip of 25X4 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I connected to earth test point using earth strip of 25x4mm as earth lead all as specified and testing on completion including provision of earth lead protected by 40 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions;-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M.[ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 40 mm bore light grade 7.5m.
28Disconnecting the existing Unserviceable MCCB, taking out from the panel board and replace by S&F new MCCB 4 pole, 200 Amps, 35/36 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, thermal & adjustable magnetic setting, fixed in existing panel and connecting with existing cable, including nuts bolts and washer etc complete all as specified and directed.
29Supply, installation, commissoning and testing, in repair, feeder pillar board, Kiosk type, LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) plinth mounted, factory made, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 50m x 50mm x 5mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enemell gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron 0.45 mtr in ground and 0.3 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete comprising of the followings:- (a) Incoming supply:- (i) Aluminium bus bar 300 amps rating of 04 strip having suitable whole with nuts and bolts (ii) on load change over switch front handle operated, 4 pole, 415 volts, 50 Hz, AC supply of 250 Amps cofirming-01 No (iii) MCCB, thermal and meganitic setting, 4 pole AC 415volts, 250 Amp rating, 35 KA rupturing capacity - 01 No (iv) Digital type voltmenter 0-500 V with selector switches - 01No (v) Digital type Amp meter 0-300A with selecter switch with CT ratio 300/5 - 01 No (vi) Indicatiing lamp Neon type for R-Y-B - 3 Nos (b) Outgoing supply:- (i) MCCB, thermal and meganitic setting, 4 pole AC 415volts, 160 Amp rating, 36 KA rupturing capacity - 02 No (ii) MCCB, thermal and meganitic setting, 4 pole AC 415volts, 125 Amp rating, 25 KA rupturing capacity - 02 No. (iii) MCCB, thermal and meganitic setting, 4 pole AC 415volts, 63 Amp rating, 16 KA rupturing capacity - 02 No. (iv) MCB SPN, C-curve, 32 Amps, AC 230 Volt - 03 No including internal connections
30Supply, installation, commissioning and testing, feeder piller board, Kiosk type , LT (415 Volts, 50 Hz , 3-phase, 4 wire supply), plinth mounted, factory made, outdoor type, weather and vermin proof made out of angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron, 0.2 mtr in ground and 0.30 mtr over the ground including excavation & earth work in any type of soil and PCC complete comprising of the followings:- (a) Incoming supply:- (i) Aluminium bus bar 250 amps rating of 04 strip having suitable whole with nuts and bolts (ii) MCCB 200 Amps, 04 pole 415 Volt-01 No, (b) Outgoing supply:- (i)MCCB, thermal and meganitic setting, 4 pole AC 415volts, 125 Amp rating, 25 KA rupturing capacity - 02 No.(v), (ii) MCCB, thermal and meganitic setting, 4 pole AC 415volts, 63 Amp rating, 16 KA rupturing capacity - 02 No Digital type multifunctional meter showing A, V, Hz etc with suitable CT ratio -1No (vi) Indicating lamp Neon type for R-Y-B - 3 Nos.
31M&L for horinzontal borring under the road with trenchless in soft/loose strata for insertion of GI tube up to 80mm bore all as directed. Note:- GI Pipe shall measured separately.
32S&F, in repair, FRP insulated and PVC sheathed copper conductor cable of size 1.5 Sqmm, 3 core, 1100 volts grade, multistranded, passing throuth PVC pipe, fixed on pole/wall from juntion box to street light fitting including taking down old cable complete all as specified and directed.
33S&F, in repair, GI pipe, 40mm bore, light grade, laid below road/fixed along the poles / walls with necessary clamping,including taking down old etc complete all as per specified and directed.
34S&F, in repair, GI pipe, 50mm bore, light grade, laid below road/fixed along the poles / walls with necessary clamping,,including taking down old etc complete all as per specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57157489
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 12-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repairs/ Replacement Of Lt Cable And Panel From Chanakya Colony To Soi At Mil Stn Dhrangadhra
Basic Detail
Tender No GE(A)/GNR/TOKEN/80 of 2026-27
Bidding Type Tender
Location
City Surendranagar
State Gujarat
Key Dates
Publish Date 22 Aug 2026
Submission Date 12 Sep 2026
Open Date 14 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 32000
Exemption Available
Document List
79db0058-021d-4015-a5a5-58550ed3740c.html
BOQ_880736.xls
TenderDocuments.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Sep 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

79db0058-021d-4015-a5a5-58550ed3740c.html

xls

BOQ_880736.xls

pdf

TenderDocuments.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders