Tender For Construction Of 20M 2-Lane Reinforced Cement Concrete T Beam Motor Bridge At Km70, 30M 2-Lane Psc Girder Motor Bridge At Km72 And 20M 2-Lane Steel Plate Girder Motor Bridge At Km90 Of Tehri Hindolakhal Devprayag Vyasghat Bilkhet Motor Road (Sh-
Tender Overview
Project Description
Tender For Construction Of 20M 2-Lane Reinforced Cement Concrete T Beam Motor Bridge At Km70, 30M 2-Lane Psc Girder Motor Bridge At Km72 And 20M 2-Lane Steel Plate Girder Motor Bridge At Km90 Of Tehri Hindolakhal Devprayag Vyasghat Bilkhet Motor Road (Sh-49) In District Pauri.
BOQ
| Sl. No. | Item Description |
| 1 | Construction of 30 m Span double lane PSC Girder Motor Bridge at Km 72 of SH-49 (Bridge ID 1742) |
| 2 | Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royalties etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction. |
| 3 | Hand Packed stone filling in back of wallls including cost of all materials, royality, T&P etc. complete as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications) |
| 4 | Providing and fixing of retro - reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. For 900 mm equilateral triangle. |
| 5 | Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. |
| 6 | For 600 mm circular. |
| 7 | 800 mm x 600 mm rectangular |
| 8 | Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads , transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Cl ause 303.1. |
| 9 | Construction of Embankment with Material Obtained from Borrow with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 |
| 10 | By Mix in Place Method Construction of granular sub-base by providing well graded material , spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. For Grading I Material. |
| 11 | WBM Grading 2Providing , laying , spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate watering and compacting to the required density. Grading 2 as per Technical Specification Clause 405.By Manual Means. |
| 12 | WBM Grading 3Providing, laying, spreading and compacting stoneaggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill- up the interstices of coarse aggregate, watering and compacting to the required density. Grading 3 as per Technical Specification Clause 405. By Manual Means. |
| 13 | Type - A, \\"W\\" : Metal Beam Crash Barrier Providing and erecting a \\"W\\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/ road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810 (if Concrete Required for Vertical post Fixing will be paid extra) |
| 14 | Prime Coat, Medium porosityProviding and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90 - 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. |
| 15 | Providing and laying of hot applied thermoplastic compound of ISI Mark Approved Quality of 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. |
| 16 | AFP (Aluminum - backedflexible prismatic sheeting) Hazard Marker: Providing and fixing Aluminum-backed flexible prismatic sheeting consisting of Yellow colored flexible prismatic sheeting with non- metallic prismatic lens as retro reflective elements and conforming to ASTM D 4956-09 Type VI specification values for reboundable sheeting. AFP sheeting shall be of 1ft width and laminated at the back with a 50 micron thick Aluminum (Al) foil with pressure sensitive adhesive and liner. AFP sheeting shall have screen printed arrow/slant line pattern in black color on top & shall not crack when tested for flexibility as per section S 2 . 2 . 2 of ASTM D 4956-09. The AFP sheeting shall be applied with a neoprene contact adhesive with Polychloroprene as base & the edges of the product shall be sealed all around with a two-part epoxy based structural adhesive and shall be extremely resistant to peel - off & product specification shall confirm to IRC Accreditation. |
| 17 | Road Studs / Cat Eye: Providing and fixing of single mould twin shank reflective road studs of ‘category A’ Raised pavement markers made out of poly carbonate/ ABS moulded body and reflective panels with microprismatic lens capable of providing total internal reflection of the light entering the lens face with retro reflectance and chromaticity values shall be as given in the detailed specifications and the product shall conform to ASTM D4280. The raised pavement marker shall also meet all the testing conditions of ASTM D4280 and fixed to the road surface using the adhesive recommended by the manufacturer. Two cylindrical Polymer Shanks of not less than 20 mm diameter and not less than 30 mm length shall be molded in the RPM body. The reflective raised pavement markers shall also confirm to the MORTH circular No RW / NH. 33023/10/ 97-DO.III and the length ,height and width of the body shall not be less than 100 mm, 15 mm and 90 mm and base of marker shall be flat within 1.3 mm and outermost faces of configuration of marker shall not deviate more than 1.3 mm from a flat surface. The marker shall support a load of 13635 133 tested in accordance with ASTM D4280. The marker shall withstand flexural strength of 909 133f force in accordance with ASTM D4280. Marker lenses shall be moulded of Polycarbonate or methyl methecrylate conforming to ASTM D788. The area of each retro reflectory surface shall not be less than 13.0 sq.cm. The slope or retro – reflectory surface shall be 35 + 5 degree to base. Each reflector shall have a CIL not less than values specified in table 1 of MORTH Section 8 0 0 pageno . 3 5 3 and should accompany two year warranty for satisfactory field performance from the manufacturer. |
| 18 | Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510By Manual MeansCase - I : Type A Bitumen (VG-30). |
| 19 | Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. |
| 20 | 20 mm thick Open - Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder. Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 k N static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case - I, By Manual Means, Bitumen (VG-30). |
| 21 | Excavation for structure: Earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of ides and bottom and backfilling in trenches with excavated suitable material. |
| 22 | Plain cement concrete in open foundation complete as per drawing and technical specifications PCC Grade M15 using concrete mixer. Including all royalty, formwork, curing etc. |
| 23 | Plain cement concrete in open foundation complete as per drawing and technical specifications PCC Grade M20 using concrete mixer. Including all royalty, formwork, curing etc. |
| 24 | Providing weepholes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100mm dia AC Pipe extending through the full width of the structures with slope of 1 ( V): 20 ( H) towards drawing face complete as per drawing and technical specification clauses 614,709,1204.3.7 |
| 25 | Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and back filling with approved material.) Ordinary soil Mechanical Means Depth upto 3 m. |
| 26 | Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and back filling with approved material.) Hard rock (blasting prohibited) Mechanical Means. |
| 27 | Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. PCC Grade M15 With Batching Plant, Transit Mixer and Manual placing. Including all royalty, formwork, curing etc. |
| 28 | Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications RCC Grade M30 With Batching Plant, Transit Mixer and Manual placing Including all royalty, formwork, curing etc. |
| 29 | Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications.(Fe grade 500 D) |
| 30 | Plain/ Reinforced cement concrete in sub-structure complete as per drawing and technical specifications RCC Grade M30 Height upto 5m With Batching Plant, Transit Mixer and Concrete Pump. Including all royalty, formwork, curing etc. |
| 31 | Plain/ Reinforced cement concrete in sub-structure complete as per drawing and technical specifications RCC Grade M30 Height 5m to 10m With Batching Plant, Transit Mixer and Concrete Pump. Including all royalty, formwork, curing etc. |
| 32 | Plain/ Reinforced cement concrete in sub-structure complete as per drawing and technical specifications RCC Grade M30 Height above 10m With Batching Plant, Transit Mixer and Concrete Pump. Including all royalty, formwork, curing etc. |
| 33 | Supplying, fitting and placing HYSD bar reinforcement in sub - structure complete as per drawing and technical specifications. (Fe grade 500 D) |
| 34 | Providing weep holes in Brick masonry / Plain / Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications. |
| 35 | Providing and laying of Filter media with granular materials / stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification. |
| 36 | Furnishing and Placing Reinforced / Prestressed cement concrete in super- structure as per drawing and Technical Specification RCC/PSC Grade M-40. For solid slab super-structure, Height above 10m. |
| 37 | Furnishing and Placing Reinforced / Prestressed cement concrete in super- structure as per drawing and Technical Specification RCC/PSC Grade M-45. For I-beam & slab including launching of precast girders by launching truss upto 40 m span, Height above 10m. |
| 38 | Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications. (Fe grade 500 D) |
| 39 | High tensile steelwires / strands including all accessories for stressing, stressing operations and grouting complete as per drawing and Technical Specifications. |
| 40 | Providing and laying Cement concrete wearing coat M- 30 grade including reinforcement complete as per drawing and Technical Specifications. Including all royalty, formwork, curing etc. |
| 41 | Drainage Spouts complete as per drawing and Technical specification. |
| 42 | PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification With Batching Plant, Transit Mixer and Manual placing. |
| 43 | Reinforced cement concrete (M30) approach slab including reinforcement and formwork complete as per drawing and Technical specification. Including all royalty, formwork, curing etc. |
| 44 | Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.). |
| 45 | Strip Seal Expansion Joint(Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer / supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.) |
| 46 | Painting Two Coats on New Concrete Surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces) |
| 47 | Provision of an Reinforced cement concrete new jersey crash barrier at the medians, constructed with Reinforced Cement Concrete with HYSD reinforcement conforming to conforming MoRT&H Specification and as per details given IRC - 119 ( Fig . - 26 ) including dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board etc.., as per approved drawing and at locations directed by the Engineer, all as specified. (Area-0.261 Sqm. /Meter, Double Face) M 30 grade concrete- M 30 grade concrete & HYSD steel reinforcement. |
| 48 | Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, complete assembly to be of cast steel/fabricated structural steel, metal and elastomer elements to be as per IRC: 83 part-I & II respectively and other parts conforming to BS: 5400 , section 9.1 & 9.2 and clause 2006 of MoRTH specifications complete as per drawing and approved Technical specifications. (Including the cost of bearing assembly). (Load capacity of Bearing shall be considered in MT) |
| 49 | Doing load test on bridge span as per IRC code provision, inclusiveof mobilization, loading , field measurement & submission of report complete in all aspect. |
| 50 | Providing & fixing 25 mm dia. 1.80m long rock anchoring including supply of all materials T& P etc complete in all aspects. |
| 51 | Conformatory detailed soil investigation : Detailed soil investigation in all type of soil & rock by drilling Nx size Bore Holes (preserving cores in core box for RQD and compressive strength) for at least per abutment up to depth 5m continuous in rock, maximum 10m or upto redusal, SPT at every metres, collection of UDS / D S, determining shear strength, rock strength, soil parameters, analysis and to conclude the SBC com, submission of comprehensive report with interpretation / suggestion / recommendation. |
| 52 | Environmental Monitoring.Testing of ambient air quality, water quality noise levels and soil near the construction site, preconstruction, during construction and post construction, with no. of samples as per mentioned in EMP and submitting the report in specified formats and intervals as required, including water sprinkling at site to supress dust to minimise the dust pollution at site during construction period, including shrub and grass plantation on/ near site, including EMP training at site and EMP report preparation, all as per direction of Engineer-in-charge. |
| 53 | Air Quality test (samples) |
| 54 | Water Quality test (samples) |
| 55 | Noise Levels test (samples) |
| 56 | Soil test (Samples) |
| 57 | Water sprinkling at site. |
| 58 | Shrub and grass plantation on/ near site. |
| 59 | EMP training at site and EMP report preparation. |
| 60 | Construction of 20 m Span double lane Steel Plate Girder Motor Bridge at Km 90 of SH-49 (Bridge ID 1749) |
| 61 | Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction. |
| 62 | Hand Packed stone filling in back of wallls including cost of all materials, royality, T&P etc. complete as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications) |
| 63 | Road Studs / Cat Eye: Providing and fixing of single mould twin shank reflective road studs of ‘category A’ Raised pavement markers made out of poly carbonate/ ABS moulded body and reflective panels with microprismatic lens capable of providing total internal reflection of the light entering the lens face with retro reflectance and chromaticity values shall be as given in the detailed specifications and the product shall conform to ASTM D4280. The raised pavement marker shall also meet all the testing conditions of ASTM D4280 and fixed to the road surface using the adhesive recommended by the manufacturer. Two cylindrical Polymer Shanks of not less than 20 mm diameter and not less than 30 mm length shall be molded in the RPM body. The reflective raised pavement markers shall also confirm to the MORTH circular No RW / NH. 33023/10/ 97-DO.III and the length ,height and width of the body shall not be less than 100 mm, 15 mm and 90 mm and base of marker shall be flat within 1.3 mm and outermost faces of configuration of marker shall not deviate more than 1.3 mm from a flat surface. The marker shall support a load of 13635 133 tested in accordance with ASTM D4280. The marker shall withstand flexural strength of 909 133f force in accordance with ASTM D4280. Marker lenses shall be moulded of Polycarbonate or methyl methecrylate conforming to ASTM D788. The area of each retro reflectory surface shall not be less than 13.0 sq.cm. The slope or retro – reflectory surface shall be 35 + 5 degree to base. Each reflector shall have a CIL not less than values specified in table 1 of MORTH Section 8 0 0 pageno . 3 5 3 and should accompany two year warranty for satisfactory field performance from the manufacturer. |
| 64 | Providing and laying of hot applied thermoplastic compound of ISI Mark Approved Quality of 2 . 5 mm thick including reflectorising glass beads @ 250 gms per sqm area, as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. |
| 65 | AFP ( Aluminum - backedflexible prismatic sheeting) Hazard Marker: Providing and fixing Aluminum-backed flexible prismatic sheeting consisting of Yellow colored flexible prismatic sheeting with non- metallic prismatic lens as retro reflective elements and conforming to ASTM D 4956-09 Type VI specification values for reboundable sheeting. AFP sheeting shall be of 1ft width and laminated at the back with a 50 micron thick Aluminum (Al) foil with pressure sensitive adhesive and liner. AFP sheeting shall have screen printed arrow/slant line pattern in black color on top & shall not crack when tested for flexibility as per section S 2 . 2 . 2 of ASTM D 4956-09. The AFP sheeting shall be applied with a neoprene contact adhesive with Polychloroprene as base & the edges of the product shall be sealed all around with a two-part epoxy based structural adhesive and shall be extremely resistant to peel - off & product specification shall confirm to IRC Accreditation. |
| 66 | Type - A, \\"W\\" : Metal Beam Crash Barrier Providing and erecting a \\"W\\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre , 1.8 m high, 1.1 m below ground/ road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810 (if Concrete Required for Vertical post Fixing will be paid extra) |
| 67 | Prime Coat, Medium porosityProviding and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90 - 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. |
| 68 | Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. |
| 69 | Seal CoatProviding and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 By Manual Means Case - I : Type A Bitumen (VG-10) |
| 70 | WBM Grading 3Providing, laying, spreading and compacting stoneaggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill- up the interstices of coarse aggregate, watering and compacting to the required density. Grading 3 as per Technical Specification Clause 405. By Manual Means. |
| 71 | By Mix in Place Method Construction of granular sub-base by providing well graded material , spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. For Grading I Material. |
| 72 | WBM Grading 2Providing , laying , spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate watering and compacting to the required density. Grading 2 as per Technical Specification Clause 405.By Manual Means. |
| 73 | Providing and fixing of retro - reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. For 900 mm equilateral triangle. |
| 74 | Providing and fixing of retro - reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. For 600 mm circular. |
| 75 | Providing and fixing of retro - reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. For 800 mm x 600 mm rectangular. |
| 76 | Excavation for Structures.Earthwork in excavation for structures as per drawing and technical specifications Clause 305 . 1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil Upto 3 m depth. |
| 77 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. P.C.C grade M15 Nominal mix (1:2.5:5). Including all royalty, formwork, curing etc. |
| 78 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. P.C.C. grade M20 Nominal mix (1:2:4). Including all royalty, formwork, curing etc. |
| 79 | Providing weep holes in brick masonry / stonemasonry, plain / reinforced concrete abutment , wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
| 80 | Construction of Embankment with Material Obtained from Borrow with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 |
| 81 | Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) Hard rock (blasting prohibited) Mechanical Means. |
| 82 | Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. PCC Grade M15 With Batching Plant, Transit Mixer and Manual placing. Including all royalty, formwork, curing etc. |
| 83 | Plain/ Reinforced cement concrete in sub-structure complete as per drawing and technical specifications RCC Grade M30 Height upto 5m With Batching Plant, Transit Mixer and Concrete Pump |
| 84 | Plain/ Reinforced cement concrete in sub-structure complete as per drawing and technical specifications. RCC Grade M30 Height 5m to 10m With Batching Plant, Transit Mixer and Concrete Pump. Including all royalty, formwork, curing etc. |
| 85 | Providing weepholes in Brick masonry / Plain / Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications. |
| 86 | Providing and laying of Filter media with granular materials / stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification. |
| 87 | Furnishing and Placing Reinforced / Prestressed cement concrete in super- structure as per drawing and Technical Specification RCC Grade M 30 For solid slab super-structure, Height above 10m. |
| 88 | Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications. (Fe grade 500 D) |
| 89 | Supplying, fitting and placing HYSD bar reinforcement in sub - structure complete as per drawing and technical specifications. (Fe grade 500 D) |
| 90 | Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications. (Fe grade 500D) |
| 91 | Provision of an Reinforced cement concrete new jersey crash barrier at the medians, constructed with Reinforced Cement Concrete with HYSD reinforcement conforming to conforming MoRT&H Specification and as per details givenIRC - 119 (Fig . - 26 ) including dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board etc.., as per approved drawing and at locations directed by the Engineer, all as specified. (Area -0.261 Sqm. /Meter, Double Face) M 30 grade concrete- M 30 grade concrete & HYSD steel reinforcement. Including all royalty, formwork, curing etc. |
| 92 | Painting on Steel Surfaces (Providing and applying two coats of ready mix paint of approved brand on steel surface after through cleaning of surface to give an even shade). |
| 93 | Painting Two Coats on New Concrete Surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces). |
| 94 | Drainage Spouts complete as per drawing and Technical specification. |
| 95 | Providing and laying Cement concrete wearing coat M- 30 grade including reinforcement complete as per drawing and Technical Specifications. Including all royalty, formwork, curing etc. |
| 96 | PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification With Batching Plant, Transit Mixer and Concrete Pump. |
| 97 | Reinforced cement concrete (M30) approach slab including reinforcement and formwork complete as per drawing and Technical specification. Including all royalty, formwork, curing etc. |
| 98 | Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer / supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.) |
| 99 | Supply and fabrication of steel truss bridge as per detailed drawing attached including supply of all structural steel E-250 confirming IS 226 - 1969 required for proper completion of the bridge including ground errection of the bridge and one coat of approved quality anticirrosive (redoxide) paintof confirming IS 5660, all T&P, nuts and bolts, washers and also including supply and fixing of shop rivets required as per drawing, required equipment shall be arranged by the contractor at his own cost which shall be taken back by the contractor after satisfactory execution of the job, the rates shall include ground errection in the workshop and its dismentling after inspection, approval and removing defects, match marking of all parts, numbering and proper stacking in the premises of workshop before cartage to site of work. The work shall be executed in accordance to IS - 1915. The rates shall include cost of all material, its wastage, cutting, bending if required, welding, making holes, shop riveting, labour, T&P etc. required for proper completion of the work. including cost of cartage from workshop to Bridge Site including safe stacking of parts. |
| 100 | Supply and fabrication of steel truss bridge as per detailed drawing attached including supply of all structural steel E-350 confirming IS 226 - 1969 required for proper completion of the bridge including ground errection of the bridge and one coat of approved quality anticirrosive (redoxide) paint of confirming IS 5660, all T&P, nuts and bolts, washers and also including supply and fixing of shop rivets required as per drawing, required equipment shall be arranged by the contractor at his own cost which shall be taken back by the contractor after satisfactory execution of the job, the rates shall includegrounderrectioninthe workshop and its dismentling after inspection, approval and removing defects, match marking of all parts, numbering and proper stacking in the premises of workshop before cartage to site of work. The work shall be executed in accordance to IS - 1915. The rates shall include cost of all material, its wastage, cutting, bending if required, welding, making holes, shop riveting, labour, T&P etc. required for proper completion of the work. including cost of cartage from workshop to Bridge Site including safe stacking of parts. |
| 101 | Erection of Steel Truss (Girder) Bridge (up to 60m span) as per drawing with required camber including cartage of fabricated parts from the place of stack near site including submission of launching plan by the contractor, (duly vetted by a recognised reputable institution/ consultant if required) and approved by the engineer- in- charge. Service bolts to used shall be of approved make. The rate including of cost of all labour, T&P, equipments, civil work and consumables, cost of arranging, fabricating, errecting and dismantling of erection scheme including the cost of its designing, revising, supervision by contractor' s designeer at site during erection, also including cost of all safety measures and necessary insurances of bridge and labours for proper completion of the work as per MORTH specification no. 1905 with due regard of mansoon and as per directions of the engineer-in-charge. |
| 102 | Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, complete assembly to be of cast steel/fabricated structural steel, metal and elastomer elements to be as per IRC: 83 part-I & II respectively and other parts conforming to BS: 5400 , section 9.1 & 9.2 and clause 2006 of MoRTH specifications complete as per drawing and approved Technical specifications. (Including the cost of bearing assembly). (Load capacity of Bearing shall be considered in MT) |
| 103 | Providing & fixing 25 mm dia. 1.80m long rock anchoring including supply of all materials T& P etc complete in all respects. |
| 104 | Doing load test on bridge span as per IRC code provision, inclusive of mobilization, loading, field measurement & submission of report complete in all respect. |
| 105 | Supply and fixing of 20mm dia. PF make 10.9 grade HSFG high strength friction grip bolt to IS 3757: 1985 latest to grade 10.9S with High strength friction grip nut to IS 6623:2004 latest to grade 10S and high strength friction 2 no. washer including cost of all material, labour, fixing at site, all taxes, T&P etc required for proper completion of work (20x120mm). |
| 106 | Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications RCC Grade M30 With Batching Plant, Transit Mixer and Manual placing. Including all royalty, formwork, curing etc. |
| 107 | Hand Packed stone filling in back of wallls including cost of all materials, royality, T&P etc. complete as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications). |
| 108 | Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction. |
| 109 | Excavation in soil in Hilly Area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1 |
| 110 | Excavation in hilly area in ordinary rock not requiring blasting by mechanical means including cutting and trimming of slopes and disposal of cut material with a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2. |
| 111 | Excavation in hilly areas in hard rock requiring blasting, by mechanical means, lift upto 1.5 m and disposal of excavated rock upto a lead of 20 m as per Clause 1603.2. |
| 112 | Construction of Embankment with Material Obtained from Roadway Cutting Construction of embankmentwith approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300. 2 as per Technical Specification Clause 301.5 |
| 113 | By Mix in Place Method Construction of granular sub-base by providing well graded material , spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. For Grading I Material. |
| 114 | WBM Grading 2 Providing , laying , spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading i n uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applyingandbrooming , stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. By Manual Means. |
| 115 | Haulage excluding Loading & Unloading- Haulage of materials by tipper excluding cost of loading, unloading and stacking. Surfaced Road. |
| 116 | Loading and Unloading of Structural Steel and Steel Bars by manual means Loading of Structural Steel, Steel Bars by manual means including a lead upto 30 m. |
| 117 | Providing and fixing of retro - reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. For 900 mm equilateral triangle. |
| 118 | Providing and fixing of retro - reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. For 600 mm circular. |
| 119 | Providing and fixing of retro - reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801.for 800 mm x 600 mm rectangular |
| 120 | Providing weep holes in brick masonry / stone masonry, plain / reinforced concrete abutment , wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V) : 20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
| 121 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C. grade M 20 Nominal mix (1:2:4). Including all royalty, formwork, curing etc. |
| 122 | Type - A, \\"W\\" : Metal Beam Crash Barrier Providing and erecting a \\"W\\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1. 8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810 (if Concrete Required for Vertical post Fixing will be paid extra). |
| 123 | Erection of Steel Truss (Girder) Bridge (up to 60m span) as per drawing with required camber including cartage of fabricated parts from the place of stack near site including submission of launching plan by the contractor, (duly vetted by a recognised reputable institution/ consultant if required) and approved by the engineer- in- charge. Service bolts to used shall be of approved make. The rate including of cost of all labour, T&P, equipments, civil work and consumables, cost of arranging, fabricating, errecting and dismantling of erection scheme including the cost of its designing, revising, supervision by contractor' s designeer at site during erection, also including cost of all safety measures and necessary insurances of bridge and labours for proper completion of the work as per MORTH specification no. 1905 with due regard of mansoon and as per directions of the engineer-in-charge. |
| 124 | Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305 . 1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil Upto 3 m depth. |
| 125 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 15 Nominal mix (1:2.5:5). Including all royalty, formwork, curing etc. |
| 126 | Environmental Monitoring.Testing of ambient air quality, water quality noise levels and soil near the construction site, preconstruction, during construction and post construction, with no. of samples as per mentioned in EMP and submitting the report in specified formats and intervals as required, including water sprinkling at site to supress dust to minimise the dust pollution at site during construction period, including shrub and grass plantation on/ near site, including EMP training at site and EMP report preparation, all as per direction of Engineer-in-charge. |
| 127 | Air Quality test (samples) |
| 128 | Water Quality test (samples) |
| 129 | Noise Levels test (samples) |
| 130 | Soil test (Samples) |
| 131 | Water sprinkling at site. |
| 132 | Shrub and grass plantation on/ near site. |
| 133 | EMP training at site and EMP report preparation. |
| 134 | Construction of 20 m Span RCC T-Beam Motor bridge at Km 70 of SH-49 (Bridge ID 1740) |
| 135 | Excavation in soil in Hilly Area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1 |
| 136 | Excavation in Hilly Areas in Ordinary Rock by mechanical means not requiring blasting Excavation in hilly area in ordinary rock not requiring blasting by mechanical means including cutting and trimming of slopes and disposal of cut material with a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2. |
| 137 | Excavation in hilly areas in hard rock requiring blasting , by mechanical means, lift upto 1.5 m and disposal of excavated rock upto a lead of 20 m as per Clause 1603.2. |
| 138 | Excavation for StructuresEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.Ordinary soil Upto 3 m depth |
| 139 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203P.C.C grade M 15 Nominal mix (1:2.5:5) Including all royalty, formwork, curing etc. |
| 140 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C. grade M 20 Nominal mix (1:2:4) Including all royalty, formwork, curing etc. |
| 141 | Hand Packed stone filling in back of wallls including cost of all materials, royality, T&P etc. complete as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications) |
| 142 | Construction of Embankment with Material Obtained from Borrow with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 |
| 143 | Type - A, \\"W\\" : Metal Beam Crash Barrier Providing and erecting a \\"W\\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1. 8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810 (if Concrete Required for Vertical post Fixing will be paid extra). |
| 144 | By Mix in Place Method Construction of granular sub-base by providing well graded material , spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. For Grading I Material. |
| 145 | Prime Coat, Medium porosityProviding and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90 - 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. |
| 146 | Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. |
| 147 | 20mm thick Open-Graded Premix Carpet using Bituminous (penetrationgrade/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case - I By Manual Means. Bitumen (VG-30) |
| 148 | Seal CoatProviding and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510By Manual Means Case - I : Type A Bitumen (VG-30) |
| 149 | Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads , transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Cl ause 303.1. |
| 150 | Road Studs / Cat Eye: Providing and fixing of single mould twin shank reflective road studs of ‘category A’ Raised pavement markers made out of poly carbonate/ ABS moulded body and reflective panels with microprismatic lens capable of providing total internal reflection of the light entering the lens face with retro reflectance and chromaticity values shall be as given in the detailed specifications and the product shall conform to ASTM D4280. The raised pavement marker shall also meet all the testing conditions of ASTM D4280 and fixed to the road surface using the adhesive recommended by the manufacturer. Two cylindrical Polymer Shanks of not less than 20 mm diameter and not less than 30 mm length shall be molded in the RPM body. The reflective raised pavement markers shall also confirm to the MORTH circular No RW / NH. 33023/10/ 97-DO.III and the length ,height and width of the body shall not be less than 100 mm, 15 mm and 90 mm and base of marker shall be flat within 1.3 mm and outermost faces of configuration of marker shall not deviate more than 1.3 mm from a flat surface. The marker shall support a load of 13635 133 tested in accordance with ASTM D4280. The marker shall withstand flexural strength of 909 133f force in accordance with ASTM D4280. Marker lenses shall be moulded of Polycarbonate or methyl methecrylate conforming to ASTM D788. The area of each retro reflectory surface shall not be less than 13.0 sq.cm. The slope or retro – reflectory surface shall be 35 + 5 degree to base. Each reflector shall have a CIL not less than values specified in table 1 of MORTH Section 8 0 0 pageno . 3 5 3 and should accompany two year warranty for satisfactory field performance from the manufacturer. |
| 151 | Providing and laying of hot applied thermoplastic compound of ISI Mark Approved Quality of 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. |
| 152 | AFP ( Aluminum - backedflexible prismatic sheeting) Hazard Marker: Providing and fixing Aluminum-backed flexible prismatic sheeting consisting of Yellow colored flexible prismatic sheeting with non- metallic prismatic lens as retro reflective elements and conforming to ASTM D 4956-09 Type VI specification values for reboundable sheeting. AFP sheeting shall be of 1ft width and laminated at the back with a 50 micron thick Aluminum (Al) foil with pressure sensitive adhesive and liner. AFP sheeting shall have screen printed arrow/slant line pattern in black color on top & shall not crack when tested for flexibility as per section S 2 . 2 . 2 of ASTM D 4956-09. The AFP sheeting shall be applied with a neoprene contact adhesive with Polychloroprene as base & the edges of the product shall be sealed all around with a two-part epoxy based structural adhesive and shall be extremely resistant to peel - off & product specification shall confirm to IRC Accreditation. |
| 153 | Providing and fixing of retro - reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 |
| 154 | 900 mm equilateral triangle |
| 155 | 600 mm equilateral triangle |
| 156 | Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. |
| 157 | 800 mm x 600 mm rectangular |
| 158 | Providing weep holes in brick masonry / stone masonry, plain / reinforced concrete abutment , wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V) : 20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
| 159 | Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of allmaterial, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORDSpecifiction |
| 160 | WBM Grading 2Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. By Manual Means |
| 161 | WBM Grading 3Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. By Manual Means |
| 162 | Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and back filling with approved material.) Ordinary soil Mechanical Means Depth upto 3 m. |
| 163 | Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. PCC Grade M15 With Batching Plant, Transit Mixer and Manual placing. Including all royalty, formwork, curing etc. |
| 164 | Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications RCC Grade M30 With Batching Plant, Transit Mixer and Manual placing Including all royalty, formwork, curing etc. |
| 165 | Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications. (Fe grade 500 D) |
| 166 | Plain/ Reinforced cement concrete in sub-structure complete as per drawing and technical specifications RCC Grade M30 Height upto 5m With Batching Plant, Transit Mixer and Concrete Pump. Including all royalty, formwork, curing etc. |
| 167 | Plain/ Reinforced cement concrete in sub-structure complete as per drawing and technical specifications RCC Grade M30 Height 5m to 10m With Batching Plant, Transit Mixer and Concrete Pump. Including all royalty, formwork, curing etc. |
| 168 | Plain/ Reinforced cement concrete in sub-structure complete as per drawing and technical specifications RCC Grade M30 Height above 10m With Batching Plant, Transit Mixer and Concrete Pump. Including all royalty, formwork, curing etc. |
| 169 | Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) Ordinary soil Mechanical Means Depth 3 m to 6 m. |
| 170 | Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) Hard rock (blasting prohibited) Mechanical Means. |
| 171 | Supplying, fitting and placing HYSD bar reinforcement in sub - structure complete as per drawing and technical specifications.(Fe grade 500 D) |
| 172 | Providing weepholes in Brick masonry / Plain / Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications. |
| 173 | Providing and laying of Filter media with granular materials / stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification. |
| 174 | Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawingand Technical Specification RCC Grade M 30 For T-beam & slab, Height above 10m |
| 175 | Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications. (Fe grade 500 D) |
| 176 | Provision of an Reinforced cement concrete new jersey crash barrier at the medians, constructed with Reinforced Cement Concrete with HYSD reinforcement conforming to conforming MoRT&H Specification and as per details givenIRC - 119 (Fig . - 26 ) including dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board etc.., as per approved drawing and at locations directed by the Engineer, all as specified. (Area -0.261 Sqm. /Meter, Double Face) M 30 grade concrete- M 30 grade concrete & HYSD steel reinforcement. Including all royalty, formwork, curing etc. |
| 177 | Drainage Spouts complete as per drawing and Technical specification. |
| 178 | Providing and laying Cement concrete wearing coat M- 30 grade including reinforcement complete as per drawing and Technical Specifications. Including all royalty, formwork, curing etc. |
| 179 | PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification With Batching Plant, Transit Mixer and Manual placing. |
| 180 | Reinforced cement concrete (M30) approach slab including reinforcement and formwork complete as per drawing and Technical specification. Including all royalty, formwork, curing etc. |
| 181 | Strip Seal Expansion Joint(Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer / supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.) |
| 182 | Painting Two Coats on New Concrete Surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces). |
| 183 | Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.) |
| 184 | Detail of soil investigation in all type of soil & rock by drilling Nx size bore holes (preserving coarse in Core Box for RQD and comppresive strength) for atleast per abutment upto depth 5m continuous in rock maximum 10mts. or upto Redusal, SPT at evry Mts. Collection of UDS/ DS, Determining Shear strength, Rock strength, soil parameters, Analysis and to conclude the SBC com, Submission of Comprehensive Report with interpretation/ Suggestion/ Recommendation. |
| 185 | Providing & fixing 25 mm dia. 1.80m long rock anchoring including supply of all materials T& P etc complete in all aspects. |
| 186 | Doing load test on bridge span as per IRC code provision, inclusiveof mobilization, loading , field measurement & submission of report complete in all aspect. |
| 187 | Supplying and fitting anf fixing in position true to line and level elastomeric bearing cinfirming to IRC:83 (PART-2) SECTION IX and clause 2005 of Morth specification complete including all accessories as per drawing ( including the cost bearing assembly ) |
| 188 | Environmental Monitoring.Testing of ambient air quality, water quality noise levels and soil near the construction site, preconstruction, during construction and post construction, with no. of samples as per mentioned in EMP and submitting the report in specified formats and intervals as required, including water sprinkling at site to supress dust to minimise the dust pollution at site during construction period, including shrub and grass plantation on/ near site, including EMP training at site and EMP report preparation, all as per direction of Engineer-in-charge. |
| 189 | Air Quality test (samples) |
| 190 | Water Quality test (samples) |
| 191 | Noise Levels test (samples) |
| 192 | Soil test (Samples) |
| 193 | Water sprinkling at site. |
| 194 | Shrub and grass plantation on/ near site. |
| 195 | EMP training at site and EMP report preparation. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender