Tender For Construction Of 36 M Span Double Lane Steel Truss Motor Bridge At Km 18 Of Banswara Kansil Chandranagar Mohankhal Motor Road (Sh 56) In Agastyamuni Block Of District Rudraprayag.
Tender Value
6.73 Crore
Estimated cost
Bid Submission
22 Sep 2026
29 days left
EMD
13.47 Lakhs
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Rudra Prayag → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Construction Of 36 M Span Double Lane Steel Truss Motor Bridge At Km 18 Of Banswara Kansil Chandranagar Mohankhal Motor Road (Sh 56) In Agastyamuni Block Of District Rudraprayag.
BOQ
| Sl. No. | Item Description |
| 1 | 36 M SPAN BRIDGE WORK (Bridge ID 977) |
| 2 | Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Mechanical Means. |
| 3 | Depth upto 3.0 M. |
| 4 | Depth 3.0 to 6.0 M. |
| 5 | Depth Above 6.0 M. |
| 6 | Plain cement concrete in open foundation complete as per drawing and technical specifications. PCC Grade M15. |
| 7 | Reinforced cement concrete in open foundation complete as per drawing and technical specifications. RCC Grade M 30 Using Batching Plant, Transit Mixer and Concrete Pump |
| 8 | Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications |
| 9 | Plai/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications. RCC Grade M 30 Using Batching Plant, Transit Mixer and Concrete Pump |
| 10 | Height upto 5.0 M. |
| 11 | Height 5.0 to 10.0 M. |
| 12 | Height above 10.0 M. |
| 13 | Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications. |
| 14 | Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications |
| 15 | Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification. |
| 16 | Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification. Using Batching Plant, Transit Mixer and Concrete Pump for Solid Slab Super Structure. Hight Above 10 m. RCC Grade M 30. |
| 17 | Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications. |
| 18 | Provision of an Reinforced cement concrete new jersey crash barrier at the medians, constructed with Reinforced Cement Concrete with HYSD reinforcement conforming to conforming MoRT&H Specification and as per details given IRC - 119 ( Fig . - 26 ) including dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board etc.., as per approved drawing and at locations directed by the Engineer, all as specified. (Area-0.261 Sqm. /Meter, Double Face). M 30 grade concrete & HYSD steel reinforcement. |
| 19 | Supply and fabrication of steel truss bridge as per detailed drawing attached including supply of all structural steel E-350 confirming IS 226 - 1969 required for proper completion of the bridge including ground errection of the bridge and one coat of approved quality anticirrosive (redoxide) paintof confirming IS 5660, all T&P, nuts and bolts, washers and also including supply and fixing of shop rivets required as per drawing, required equipment shall be arranged by the contractor at his own cost which shall be taken back by the contractor after satisfactory execution of the job, the rates shall include ground errection in the workshop and its dismentling after inspection, approval and removing defects, match marking of all parts, numbering and proper stacking in the premises of workshop before cartage to site of work. The work shall be executed in accordance to IS - 1915. The rates shall include cost of all material, its wastage, cutting, bending if required, welding, making holes, shop riveting, labour, T&P etc. required for proper completion of the work. including cost of cartage from workshop to Bridge Site including safe stacking of parts. |
| 20 | Erection of Steel Truss (Girder) Bridge (up to 60m span) as per drawing with required camber including cartage of fabricated parts from the place of stack near site including submission of launching plan by the contractor, (duly vetted by a recognised reputable institution/ consultant if required) and approved by the engineer-in-charge. Service bolts to used shall be of approved make. The rate including of cost of all labour, T&P, equipments, civil work and consumables, cost of arranging, fabricating, errecting and dismantling of erection scheme including the cost of its designing, revising, supervision by contractor's designeer at site during erection, also including cost of all safety measures and necessary insurances of bridge and labours for proper completion of the work as per MORTH specification no. 1905 with due regard of mansoon and as per directions of the engineer-incharge. |
| 21 | Drainage Spouts complete as per drawing and Technical specification. |
| 22 | Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications |
| 23 | PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification |
| 24 | Reinforced cement concrete (M-30) approach slab including formwork & reinforcement steel, complete as per drawing and Technical specification |
| 25 | Providing and laying of strip seal expansion joint catering to maximum horizontal movement upto 70 mm (complete as per approved drawings and standard specifications) to be installed by the manufacturer / supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation |
| 26 | Painting on Steel Surfaces.Providing and applying two coats of readymix paint of approved brand on steel suface after through cleaning of surface to give an even. |
| 27 | Painting Two Coats on New Concrete Surfaces.(Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces |
| 28 | Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, complete assembly to be of cast steel/fabricated structural steel, metal and elastomer elements to be as per IRC: 83 part-I & II respectively and other parts conforming to BS: 5400, section 9.1 & 9.2 and clause 2006 of MoRTH Specifications complete as per drawing and approved Technical Specifications. (Including the Cost of Bearing Assembly). (Including the Cost of Bearing Assembly). |
| 29 | Supply and Fixing of 16 - 24 mm dia P.F. make 10.90 grade HSFG High Strength Friction Grip Bolt to IS 3757:1985 latest to grade 10.9S with High Strength Friction Grip nut to IS 6623:2004 latest to grade 10S and high Strength Friction 2 No. washer including cost of all material, Labour, Fixing at site, all taxes, T&P etc required for Proper completion of the work (16 to 24 mm X 120mm) . |
| 30 | Conformatory detailed Soil Investigation:Detailed Soil Investigation in all type of soil & Rock by Drilling Nx Size Bore Holes (Preserving Cores in Core Box for RQD and Compressive Strength) for at least Per Abutment up to depth 5mts. Continious in rock , maximum 10 mts. or upto Redusal, SPT at every Mts., Collection of UDS/DS, Determining Shear Strength, Rock Strength , Soil Parameters, Analysis and to conclude the SBC com, Submission of Comprehensive Report with interpretation / Suggestion / Recommendation. |
| 31 | Doing load test on bridge span as per IRC code provision, inclusive of mobilization/ demobilization, loading, field measurement & submission of report complete in all respect. |
| 32 | APPROACH ROAD WORK (Bridge ID 977) |
| 33 | Excavation in Hilly Areas in Soil by mechanical means.Excavation in soil in Hilly Area by mechanical means including cutting and ntrimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1 |
| 34 | Excavation in Foundation for retainig, breast wall etc. in all type of soil and rock including all leadf lift and disposal of surplus material as per direction of engineer-in-charge as per drawing and technical specification Clauses 305-1 of MORTH Specification |
| 35 | Providing Concrete for Plain/reinforced concrete in open foundation complete as per drawing and technical specifications Clauses 802, 803, 1202 & 1203 PCC Grade M 15 |
| 36 | Providing Concrete for Plain/reinforced concrete in open foundation complete as per drawing and technical specifications Clauses 802, 803, 1202 & 1203. PCC Grade M 20. |
| 37 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
| 38 | Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction |
| 39 | Hand Packed stone filling in back of wallls including cost of all materials, royality, T&P etc. complete as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications) |
| 40 | Construction of Embankment with Material Obtained from Borrow Pits.Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 |
| 41 | Providing and erecting a \\"W\\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810 (Vertical post fixed in M15 cement concrete filled in standard pit of size 1.20m x 0.45m x 0.45m) Type - A, \\"W\\" : Metal Beam Crash Barrier |
| 42 | Granular sub-base with well graded material (table 400.1) by Mix in Place Method.Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 for grading- I Material |
| 43 | WBM Grading 2Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. By Manual Means. |
| 44 | WBM Grading 3Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. By Manual Means. |
| 45 | Prime coat Medium porosity.Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. |
| 46 | Tack Coat.Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. |
| 47 | Seal CoatProviding and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per nTechnical Specification Clause 510.Type A by Manual Means using Bitumen (VG-10). |
| 48 | 20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) BinderProviding, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508 Manual Means Bitumen (VG-10) |
| 49 | Construction of Subgrade and Earthen ShouldersConstruction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. |
| 50 | Road Studs / Cat Eye:Providing and fixing of single mould twin shank reflective road studs of ‘category A’ Raised pavement markers made out of poly carbonate/ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face with retro reflectance and chromaticity values shall be as given in the detailed specifications and the product shall conform to ASTM D4280. The raised pavement marker shall also meet all the testing conditions of ASTM D4280 and fixed to the road surface using the adhesive recommended by the manufacturer. Two cylindrical Polymer Shanks of not less than 20 mm diameter and not less than 30 mm length shall be molded in the RPM body. The reflective raised pavement markers shall also confirm to the MORTH circular No RW / NH. 33023/10/ 97-DO.III and the length ,height and width of the body shall not be less than 100 mm, 15 mm and 90 mm and base of marker shall be flat within 1.3 mm and outermost faces of configuration of marker shall not deviate more than 1.3 mm from a flat surface. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280. The marker shall withstand flexural strength of 909 kgf force in accordance with ASTM D4280. Marker lenses shall be moulded of Polycarbonate or methyl methecrylate conforming to ASTM D788. The area of each retro reflectory surface shall not be less than 13.0 sq.cm. The slope or retro – reflectory surface shall be 35 + 5 degree to base. Each reflector shall have a CIL not less than values specified in table 1 of MORTH Section 800 page no. 353 and should accompany two year warranty for satisfactory field performance from the manufacturer. |
| 51 | Providing and laying of hot applied thermoplastic compound of ISI Mark Approved Quality of 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. |
| 52 | AFP (Aluminum-backed flexible prismatic sheeting) Hazard Marker:Providing and fixing Aluminum-backed flexible prismatic sheeting consisting of Yellow colored flexible prismatic sheeting with non-metallic prismatic lens as retro reflective elements and conforming to ASTM D 4956-09 Type VI specification values for reboundable sheeting. AFP sheeting shall be of 1ft width and laminated at the back with a 50 micron thick Aluminum (Al) foil with pressure sensitive adhesive and liner. AFP sheeting shall have screen printed arrow/slant line pattern in black color on top & shall not crack when tested for flexibility as per section S2.2.2 of ASTM D 4956-09. The AFP sheeting shall be applied with a neoprene contact adhesive with Polychloroprene as base & the edges of the product shall be sealed all around with a two-part epoxy based structural adhesive and shall be extremely resistant to peel-off & product specification shall confirm to IRC Accreditation |
| 53 | Retro-Reflectorised Traffic Signs(Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing) |
| 54 | 900 mm equilateral triangle |
| 55 | 600 mm circular |
| 56 | 800 mm x 600 mm rectangular |
| 57 | Environmental Monitoring.Testing of ambient air quality, water quality noise levels and soil near the construction site, preconstruction, during construction and post construction, with no. of samples as per mentioned in EMP and submitting the report in specified formats and intervals as required, including water sprinkling at site to supress dust to minimise the dust pollution at site during construction period, including shrub and grass plantation on/ near site, including EMP training at site and EMP report preparation, all as per direction of Engineer-in-charge. |
| 58 | Air Quality test (samples) |
| 59 | Water Quality test (samples) |
| 60 | Noise Levels test (samples) |
| 61 | Soil test (Samples) |
| 62 | Water sprinkling at site. |
| 63 | Shrub and grass plantation on/ near site. |
| 64 | EMP training at site and EMP report preparation. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 29 daysSep 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 29 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender