Tender For Upgradation Of Existing Qc Lab At Barauni Terminal Under Bso
Tender Value
Ref. Documents
Estimated cost
Bid Submission
04 Sep 2026
10 days left
EMD
46000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
barauni → Bihar
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Upgradation Of Existing Qc Lab At Barauni Terminal Under Bso
BOQ
| Sl. No. | Item Description |
| 1 | Providing & laying cement concrete in retaining walls, return walls,walls (any thickness) including attached pilasters, columns, piers,abutments, pillars, posts, struts, buttresses, string or lacingcourses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. UP TO FLOOR V LEVEL excluding the cost of centering, shuttering and finishing : |
| 2 | PCC 1 cement:2coarse Sand:4 Graded Stone Aggregate20mm |
| 3 | Providing and laying in position specified grade of reinforcedcement concrete excluding the cost of centering, shuttering,finishing and reinforcement - All work up to plinth level |
| 4 | RCC 1 Cement :1½ Coarse Sand: 3Graded Stone Aggregate 20mm |
| 5 | Providing & Laying Reinforced cement concrete work in walls (Any thickness) including attached pilasters, buttresses, plinth andstring courses, fillets, columns, pillars, piers, abutments, posts andstruts etc. above plinth level UP TO FLOOR V LEVEL excluding cost ofcentering, shuttering, finishing and reinforcement |
| 6 | RCC 1 Cement :1½ Coarse Sand: 3Graded Stone Aggregate 20mm |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 8 | Foundations,footings, bases ofcolumns, etc. for mass concrete |
| 9 | Walls (any thickness) including attached pilasters, buttress, plinth and string courses etc |
| 10 | Suspended floors,roofs,landings,balconies, accessplatform and Shelves (Cast in situ) |
| 11 | Lintels, beams plinth beams, girders bress umers and cantilevers |
| 12 | Columns, Pillars, Piers, Abutments,Posts and Struts. |
| 13 | Supply of Steel reinforcement for R.C.C. including straightening,cutting, bending, placing in position and binding all completeat all levels |
| 14 | Thermo Mechanically Treated Bars of Fe-500D Graded or more, conforming to IS1786 |
| 15 | Providing and laying Brick work with common burnt clay F.P.S (non-Modular) bricks of class designation 7.5 in foundation & plinth |
| 16 | Brick work in Cement mortar 1:4 (1cement: 4 coarse sand) in-superstructure in all shapes & sizes in superstructure ABOVE PLINTH& UP TO FLOOR V LEVEL |
| 17 | Half brick masonry with Classdesignation 5.0 bricks in Cement mortar 1:4 ( 1 cement : 4 coarse sand) INsuperstructure ABOVE PLINTH & UP TOP FLOOR V LEVEL |
| 18 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment withnecessary accessoriesnd screws etc. complete. |
| 19 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with nuts & screws etc. complete: |
| 20 | 300x16 mm |
| 21 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS:1285, fixed with rawl plugs and screwsor with fixing clips, or with expansion hold fasteners includingnecessary filling up of gaps at junctions,at top, bottom & sides withwith required EPDM rubber / neoprene gasket etc. Aluminium sectionsshall be smooth, rust free, straight, mitred and jointed mechanicallywherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass /stainless steel screws including fixing all complete as per drawing & the directions of Engineer-in-charge.(Cost of glazing or panels to be paid for separately) |
| 22 | Fixed Glazing with Powder coated aluminium (minimum thickness of powder coating 50 micron) sections |
| 23 | For shutters of doors, windows & ventilators with Powder coated aluminium sections including providing fixing hinges/ pivots & makingprovision for fixing of fittings wherever required including the costof EPDM rubber neoprene gasket required (Fittings shall be paid for separately) |
| 24 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc.complete as per the architectural drawings and the directions ofengineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): |
| 25 | With float glass panes of 4.0 mm thickness(weight not less than 10kg/sqm) |
| 26 | With float glass panes of 8.0 mm thickness(weight not less than 20kg/sqm) |
| 27 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately). |
| 28 | Providing & fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 29 | 100 mm |
| 30 | Providing & fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 31 | i) 250x10 mm |
| 32 | Providing and fixing 150 mm bright finished chrome plated brass hanging type floor door stopper with rubber cushion necessary brass screws, etc. complete. to suit shutter thickness complete |
| 33 | Providing & fixing chromium plated brass 100mm mortice latch & lock with 6 levers & a pair of lever handles with necessary screws etc complete (best make of approved quality). |
| 34 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/Stone work by providing weather silicon sealant over backer rod ofapproved quality as per direction of Engineer in Charge complete Upto 5mm depth and 5mm width |
| 35 | Structural steel work in built up sections/ framed work in gratings, frames, guard bar, ladder,railings, brackets, gates and similarworks including cutting, hoisting, fixing in position & applying apriming coat of approved steel primer etc. as required. |
| 36 | Stone flooring with 18mm thick Marble/Granite stone (sample of stoneshall be approved by Engineer-in-charge) over 20 mm (average) thickbase of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointedwith cement slurry including rubbing and polishing complete. |
| 37 | Granite stone/Makrana White second quality in flooring |
| 38 | Providing & fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (minimum thickness of 5 mm) of approved make in all colours,shades except burgundy,bottle green,black of any size as approved by Engineer-in-Charge in skirting,risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade. |
| 39 | Providing & laying vitrified floor tile in different sizes (thicknessas per manufacturer) with water absorption's less than 0.08%and conforming to IS : 15622 of approved make in all colours andshades, laid on 20mm thick cement mortar as specified with coarse sandjointing with grey cement slurry @ 3.3kg/sqm including grouting thejoints with white cement and matching pigments etc. completefor flooring/skirting as specified |
| 40 | Flooring with size of Tiles 60x60Cm in cement mortar 1:4 |
| 41 | Skirting with size of Tiles 60x60Cm in Cement mortar 1:3 |
| 42 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. |
| 43 | 110 mm diameter |
| 44 | Providing & fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming toIS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. |
| 45 | 110mm Coupler |
| 46 | Providing and fixing to the inlet mouth of rain water pipe cast irongrating 15 cm diameter and weighing not less than 440 grams. |
| 47 | Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing #C# wall angle of size20x30x20mm made of 0.5mm thick pre painted steel along theperimeter of the room with help of nylon sleeves & wooden screws at300mm center to centre,suspending the main C carrier of size10x38x10mm made of G.I steel 0.7 mm thick from the soffit with helpof soffit cleat 37x27x25x1.6mm,rawl plugs of size 38x12mm & C carriersuspension clip and main carrier bracket at 1000mm c/c. Inverted triangle shaped Spring Tee having ht. of 24mm & width of 34mm made of GI steel 0.45mm thick is then fixed to the main C carrier & indirection perpendicular to it at 600mm centers with help of suspension brackets.Wherever the main C carrier and spring T have to join,C carrier and spring T connectors have to be used. All sectionsto be galvanized @ 120 gms/sqm (both side inclusive) Fixing withclip in tiles into spring 'T' with: |
| 48 | Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriersshall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm.The steel shall have organic coating with Regular Modified Polyester(RMP) paint on continues coil coating line. The thickness of coatingon top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over5-7 microns epoxy primer) and back side 8-10 Microns RMP paint overepoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protectiveSheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (forcarrier) or as desired by Engineer-in-charge. The ceiling panelshall be clipped into carriers which are suspended from steeltrusses/ purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant forexterior. The longitudinal joints of two panels shall be butt joinedwith a special type of panel splice to be fixed from inner side. Thecarrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure. |
| 49 | Providing and laying cement plaster on surfaces with fine sand including curing etc. |
| 50 | 12 mm cement plaster of mix 1:4 (1cement: 4 fine sand) |
| 51 | 20mm Cement plaster of mix 1:6 (1cement: 6 fine sand) |
| 52 | Providing and laying 6mm thick cement plaster on surfaces with fine sand including curing etc. |
| 53 | 6mm thick plaster of mix 1:3 (1cement: 3 fine sand) |
| 54 | Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 55 | Finishing walls with Acrylic Smooth exterior paint of required shade(2 or more coat applied @ 1.67 ltr/10 sqm over & including priming coat of exterior Primer applied @ 2.20kg/10 sqm) |
| 56 | Finishing walls with Deluxe Multi surface paint system for interiors & exteriors using Primer as per manufacturers specificationswith two or more coats applied on wall @ 1.25 ltr/10 sqm. over andincluding one coat of Special primer applied @ 0.75 ltr / 10sqm |
| 57 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars & disposal of unserviceable material outsidesite to an unobjectionable place as/ direction of Engineer-in-charge |
| 58 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectionalarea of R.C.C. or R.B. work) as per direction of Engineer-in-charge. |
| 59 | Demolishing brick work manually/mechanical means including stacking of serviceable material &disposal of unserviceable material outsidepremises at an unobjectionable place as / direction of Engg-in-charge |
| 60 | Demolishing cement concrete manually/ by mechanical means including disposal of material outside premises at an unobjectionable place as per direction of Engineer-in-charge. |
| 61 | ii) 1:4:8 or leaner mix (i/c equivalent design mix) |
| 62 | Dismantling doors, windows and clerestory windows (steel or wood)shutter including chowkhats, architrave, holdfasts etc. complete and stacking within premises |
| 63 | Of area 3 sq. metres and below |
| 64 | Of area beyond 3 sq. metres |
| 65 | Dismantling Steel work in built up sections in angles, tees, flats channels etc. including all gusset plates, bolts nuts, cutting rivetswelding etc.including dismembering and stacking within premises |
| 66 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within premises |
| 67 | Dismantling granite slabs / granite tiles / marble, slab on wall, floor, pump Island etc., stacking of the serviceable materials and disposal of damaged materials as directed by IOCL including all charges etc. complete |
| 68 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material within premises lead as directed by Engineer-in-charge. |
| 69 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sinkas per IS 13983 with C.I. brackets and stainless steel plug 40 mmincluding painting of fittings and brackets, cutting and making goodthe walls wherever required, Kitchen Sink with Drain board. |
| 70 | Sink with drain board 510x1040mm bowl depth 250mm |
| 71 | Providing and fixing soil, waste and vent pipes : |
| 72 | 100mm dia Sand cast iron S&S pipe as per IS: 1729. |
| 73 | 75mm dia Sand cast iron S&S pipe as per IS: 1729 |
| 74 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer pipes confirming to IS 15801, UV stabilized & anti-microbial fusion welded, having thermal stability for hot & cold water supply,including all PP - R plain & brass threaded polypropylene randomfittings, i/c fixing the pipe with clamps at 1.00 m spacing. Thisincludes testing of joints complete as/direction of Engg in Charge.Internal work # Exposed on wall. |
| 75 | PN - 16 Pipe, 16 mm OD (SDR-7.4) |
| 76 | PN - 16 Pipe, 25 mm OD (SDR-7.4) |
| 77 | PN - 16 Pipe, 40 mm OD (SDR-7.4) |
| 78 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge.Internal work - Exposed on wall |
| 79 | 20 mm nominal outer dia Pipes |
| 80 | 25 mm nominal outer dia Pipes |
| 81 | Providing and fixing B class G.I. pipes complete with G.I. fittings & clamps, i/c cutting & making good the walls etc. Internal workExposed on wall |
| 82 | 15 mm nominal outer dia Pipes |
| 83 | 20 mm nominal outer dia Pipes |
| 84 | 25 mm nominal outer dia Pipes |
| 85 | Providing and fixing brass bib cock of approved quality : |
| 86 | i) 15 mm nominal bore |
| 87 | ii) 20 mm nominal bore |
| 88 | Providing and fixing brass stop cock of approved quality : |
| 89 | i) 15 mm nominal bore |
| 90 | ii) 20 mm nominal bore |
| 91 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cementconcrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size) cement plastered on both sides withcement mortar 1:3 (1 cement : 3 coarse sand) finished with a floatingcoat of neat cement and making necessary channels for the drain etc.complete : |
| 92 | For pipes 100 to 250 mm diameter |
| 93 | Supply, fabrication, laying and testing of GI, BLACK, ERW, threaded pipes, heavy class conforming to IS 1239, PART I as per IOCL Specifications including pipeline fittings like bends, tee etc asrequired and as directed for Above Ground pipeline including painting with 2 coats of red oxide zinc phosphate primer and 2 coats ofSynthetic enamel / aluminium finish paint as per IOCL specifications |
| 94 | 40 mm dia |
| 95 | Supply and installation of screwed type gun metal valves as per IOC specifications: Ball Valve |
| 96 | S/I Screwed type GM Ball Valve of 40 mm dia |
| 97 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 98 | i) White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 99 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as perapproved make in ground/ trench/surface/pipe, etc. whereever requiredas per direction of Engineer In-charge.Note: The rate of Installation should be inclusive of Cable clamps,tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items |
| 100 | 3 Core x 2.5 sq. mm Copper Cable FRLS |
| 101 | 3.5 Core x 70 sq. mm Aluminium Cable FRLS |
| 102 | Providing earthing with 80 mm dia,3.0 M long GI (Heavy duty) perforated pipe as per IS:3043 (with latest ammendment) including providing suitable earth bus for interconnection, providing a mixtureof salt & charcoal, making earth pit chamber with chequered platecover as per standard Drwng. etc. all complete as per specification& direction of Engineer-In-charge |
| 103 | Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing andlightning protection under or aboveground complete as perspecification for the following : |
| 104 | 50 x 6 mm G.I. Strip |
| 105 | 12 S.W.G. G.I. Wire (bare) |
| 106 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single corecable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor singlecore cable etc as required. |
| 107 | Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. with modular switch, modular plate, suitable GI box |
| 108 | Dismantling of following electrical fittings / fixtures with all leads and lifts. |
| 109 | i) Electrical cables of all sizes from under / above ground position |
| 110 | ii) DPS board all types with/ without stand |
| 111 | iii) 5 to 15A switches/MCBs/plugs |
| 112 | iv) 32/63/100A DP/TPN switches/ MCCBs /MCBs |
| 113 | v) Flourescent tube light fittings of all sizes |
| 114 | Supply & laying of Automation Signal cable-Stranded (Class2) Annealed Bare Copper Conductor, Extruded PVC type C Insulated, 2 Cores Twisted to form a pair, each shielded with Aluminium backed Mylar Tape along withATC Drain Wire,multipairs laid up &Overall Shielded with Aluminium backed Mylar Tape along with ATC (Annealed Tinned Copper) Drain Wire and Extruded PVC Type ST-2 Inner Sheathed, Galvanised Steel Round Wire Armoured and Overall Extruded FRLS PVC Type ST-2 Outer Sheathed Instrumentation/Signal Cables conforming to BS 5308-2 & IS 1554-1 |
| 115 | i) 2P X 0.50 Sq.mm cable |
| 116 | ii) Supplying and drawing co-axial TV cable RG-6 grade, 0.7 MtrMtr solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 117 | Supplying and drawing following 2 pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 118 | Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make |
| 119 | i) 2 x 1.5 sq mm + 1 x 1.5 sq mm earth wire |
| 120 | ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire |
| 121 | iii) 2 x 4 sq mm + 1 x 4 sq mm earth wire |
| 122 | iv) 2 x 6 sq mm + 1 x 6 sq mm earth wire |
| 123 | v) 2 x 10 sq mm + 1 x 10 sq mm earth wire |
| 124 | vi) 2 x 16 sq mm + 1 x 16 sq mm earth wire |
| 125 | Supply and fixing of following Electrical fittings /fixtures |
| 126 | i) 5 Amp Piano type switch |
| 127 | ii) 5 Amp modular type switch |
| 128 | iii) 5 Amp Piano type 3 pin socket |
| 129 | iv) 15Amp modular type switch |
| 130 | v) 15Amp modular type 6 pin socket |
| 131 | vi) 36/40W,1200mm long flourescent tube |
| 132 | SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved including flush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer's specification and direction of Engineer In-charge. |
| 133 | i) 1or 2 module frame |
| 134 | ii) 3 module frame |
| 135 | iii) 4 module frame |
| 136 | iv) 6 module frame |
| 137 | v) 8 module frame |
| 138 | vi) 12 module frame |
| 139 | vii) 6A Modular Switch |
| 140 | viii) 15 A Modular switch |
| 141 | ix) 6A, 3 Pin Modular Socket |
| 142 | x) 15 A 6 Pin Modular socket |
| 143 | xi) 2 Pin Telephone Modular Socket |
| 144 | xii) Fan Regulator of stepped modular type |
| 145 | xiii) Modular type TV/cable sockets. |
| 146 | Supplying and fixing of MCB + ELCB (RCBO) with necessery inter connections on existing DB, Panel board. |
| 147 | 40A 4 pole 100-300mA sensitivity |
| 148 | MCB DISTRIBUTION BOARD INCLUSIVE OF 3- PHASE MCB Supply & fixing of MCB Distribution Board double door type inclusive of MCB, Three Phase, as per Approved Make of following types: (MCB - 10KA Breaking Capacity) |
| 149 | S/E 12 way DB with 63A FP RCBO, 300 mA sensitivity as incoming-1 No.& 6 to 16A SP as outgoing - 12 Nos. for each phase. |
| 150 | Supply and Installation of Flame Proof ESD Push Button |
| 151 | CEILING FANS Supply & fixing of ceiling fan for inside of the sales building of following type: |
| 152 | iii) 1200 mm sweep |
| 153 | Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. |
| 154 | Providing & fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : |
| 155 | i) 100mm inlet & 100mm outlet SCI S&S as per IS - 3989. |
| 156 | Dismantling old C.I. pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes at site within premises: |
| 157 | i) 80 mm diameter C.I. pipe |
| 158 | ii) 100 mm diameter C.I. pipe |
| 159 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : |
| 160 | i) 100 mm diameter |
| 161 | EXHAUST FANS Supply and fixing of exhaust fan including electrical wiring all shall be with per specification and direction of site In charge. The fans shall be with louvers / shutters. (The job does not include making suitable cut out in the wall for fixing the fan). |
| 162 | ii) 9\\" dia light duty, make Khaitan or equivalent |
| 163 | iii) 12\\" heavy duty, make GEC or equivalent |
| 164 | CCTV works |
| 165 | Supply and Installation of bullet IP cam |
| 166 | Supply and Installation of 8 TB Hard Disk AV SATA |
| 167 | Supply and Installationof POE 8 Port Switch |
| 168 | Supply and Installationof 4U Rack with 4 Power Socket P |
| 169 | Supply and Installationof CCTV Junction Box |
| 170 | Supply and Installation of Conduit Pipes for CAT 6 cables |
| 171 | Supply of Cat 6 armoured Cable |
| 172 | Supply of HDMI Splitter 4WAY (1 IN 4 OUT |
| 173 | Supply of HDMI Cable - 3m Standard |
| 174 | Lighting Dist. Board -125 A MCCB with EL Lighting Dist. Board -125 A MCCB with ELCB - Incomer and 6 A |
| 175 | AC Distribution Board |
| 176 | 5/15 A industrial receptacle |
| 177 | Junction box 125 X 125 X 75 flame proof |
| 178 | Junction box 125 X 125X 75 Industrial |
| 179 | Cable Gland suit at site |
| 180 | SWITCH SOCKET / SWITCH : Supply of FLP Ex'd' T3 type receptacles suitable for mounting on wall/column/structure/steel support with loopin - loop out facility, made of aluminium alloy (LM6) and IP-65 or abovedegree of protection. Inclusive of suitable plug with interlock, FLPdouble compression nickel plated brass cable glands and blanking plugsand FRP canopy. |
| 181 | Plug and socket single phase 20A, 230 V, sytem, protected with RCBO (Ie 30 mA) |
| 182 | Plug and socket 3 phase - 5 pin 100A, with 4 pole 125 amp switch |
| 183 | 2 no 10 amp on off switch |
| 184 | Supply & laying of Gas pipe line including valves other Accessoriesetc. with all respect including all materials as per engineeriing incharge |
| 185 | Supply & laying of Air pipeline including valves other Accessoriesetc. with all respect including all materials as per engineeriing incharge |
| 186 | Supply & laying of Oxygen pipeline including Supply & laying of Oxygen pipeline including valves & other Accessoriesetc. with all respect including all materials as per engineering-in-charge |
| 187 | Supply & installtion of 11 Mesh/Jhali on all ventilation with Aluminum framing including powder coating . |
| 188 | Supply & Installation of Industrial Fire Proof Exhaust Fan 12 X 12 inch including electrical wiring all shall be with per specification and direction of site In charge. The fans shall be with louvers / shutters.(The job does not include making suitable cut out in the wall forfixing the fan). |
| 189 | FIRE ALARM SYSTEM |
| 190 | Design, drawing, supply, Installtion & Commissioing, Set-up, Configuration, Integration, Testing & Commissioning of Fire alarm system panel installed in cabinet with stabilizer, battery backup & all necessary hardware. Complete asper specifications / tender documents.as per site requirment & direction by Engineering Incharge. |
| 191 | Design, drawing, supply, Installtion & Commissioing Calibration, Testing & Commissioning of IS conventional smoke detector with addressable module. Complete as per specifications / tender documents. Approved Make: Wilstrong solutions Pvt ltd as per site requirment & direction by Engineering Incharge. |
| 192 | Supply and Installation of 2.0 Ton Hot and Cold A.C. as per direction of Engineer In-charge |
| 193 | Supply and Installation Stablizer for 2.0 T A.C. as per direction of Engineer In-charge |
| 194 | Supply and Installation Copper Pipe for AC as per direction of Engineer In-charge |
| 195 | Supply and Installation 65\\" LED Full HD (Samsung/Sony/LG). Item to be completed in all respects as specifications & instructions from E.I.C./ ConsultantFor more details, please refer enclsoed technical specifications. Sony 165 cm (65 inch) 4k Ultra HD LED Smart TV (KD-65X7500F, Black) or Equivalent. |
| 196 | Supply and Installation 49\\" LED Full HD (Samsung/Sony/LG). Item to be completed in all respects as specifications & instructions from E.I.C./ ConsultantFor more details, please refer enclosed technical specifications. Model No-SONY BRAVIA KLV-49W672E(LED TV) or Equivalent |
| 197 | Dismantling old water closets icluding all fixtures |
| 198 | Dismantling old washbasins and urinals |
| 199 | Labour charges for disconnecting ceiling fan/Exhaust Fan (8\\", 12\\" & 18\\" sweep) and transportating to Electric stores |
| 200 | Supply & instl. of minimum 259L fridge as per direction of Engineer In-charge |
| 201 | Providing and fixing Urinal without sensor with Fixing or equivalent make Accessories Set, Size: 480x300x740mmJaquar make- Model No URS-WHT-13255 |
| 202 | Providing and fixing WC in all toilets Wall Hung WC (White Matt)Specification: Wall Hung WC (White Matt) ,Rimless, Blind Installation Wall Hung WC with UF Soft Close Slim Seat Cover ,Hinges, Fixing Accessories and Accessories Set Size : 375x520x400 mm or equivalent make Jaquar make- Model No SOLO SLS-WHM-6953BIUFSM |
| 203 | Providing and fixing Flushing Cistern with following Specifications:Single Piece Concealed Cistern Body (Front or Top Actuation) with Floor Mounting Frame ,Installation Kit and “P-Type” Drain ,Pipe Connection Set for Wall Hung WC (with all fittings and fixtures complete. or equivalent make (Flush tank should have dual flushing system 4/2 LPF) Jaquar make- Model No -JCS-WHT-2431FP |
| 204 | Supply & installation of Eye splash- Eye Washer Udyogi 4810GI Wall Mounted Eye/Face Wash |
| 205 | Providing and fixing SS 316 grade Railing 1000mm high made out of 1nos of 50mm Dia, 1.5mm thick SS Handrail, Vertical 40X40mm SS Squareblauster & 1.5mm thick @ 1215mm C/C,8mm thick & 100x100mm square baseplate forblauster, Ø19 mm x 1.5 mm x 3 NosHorizontal Members withproper fixing arrangements and complete fixtures, with Minimum 2 Nos ofanchor fastener bolt M10X100mm to be covered with SS cover plate. allcomplete as per drawings and as directed. (Ramp & Entrance step) |
| 206 | Providing and fixing 10 mm thick anti skid and acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. |
| 207 | In flooring on a bed of 10 mm thick mort In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement :4 coarse sand) |
| 208 | In dado/skirting on 12 mm thick mortar 1In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4coarse sand) |
| 209 | Providing & fixing of flooring with premium quality approved make Glazed Vitrified floor tiles of Matt/Antiskid FInish in different sizes ( minimum thickness 8 mm to 10 mm -as per manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar as specified with coarse sand jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. complete for flooring/skirting as specified. Rate shall include wastages, for preparation of base surface, cleaning, acid wash,and finished surface, protection with Gypsum / Pop layer over Plastic sheet and removing the same before handing over,work at all levels and as directed.Rate shall be inclusive of forming pattern as shown in drawing and wastages etc; as complete in all respects and complying with relevant standard specifications and as directed. Note:1) All vitrified tiles should be with minimum recycled content of 5%.2) Cement used should be PPC or OPC with 30% Fly Ash.\\" |
| 210 | Size of Tiles 60x60Cm in cement mortar 1:4 |
| 211 | Providing and fixing uPVC Doors with of Fenesta make including all Upvc frame, UPVC shutters, accessories like handles, locking arrangement and fixtures etc. complete as per tender specification & direction of IOCL. Pristine White No 65mm/A65P |
| 212 | \\"Providing and pasting 3M make frosted film on glazed portion of doors and partitions at locations as per direction by Site in-Charge.Note: the stickered area will be measured in length and height. Gaps between the stickering will not be deducted if the gap isless than 50 mm |
| 213 | Supply of Lighting Fixtures along with all accessories as per below desciption & tender technical specifications / data sheet |
| 214 | 40W Circular Recessed Downlight (Equivalent to PhilipsCDR-216-40-57-SL-NWH) |
| 215 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-c hambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC ex truded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, z inc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to fi nished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent f inished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all comple te as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be p aid separately) |
| 216 | Two track two panels sliding window made of (small series) frame 52 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0. 2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) |
| 217 | Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension . (Area of window above 1.75 sqm upto 2.50 sqm). |
| 218 | \\"Lighting Distribution Board / AC Distribution Board installation, testing and commissioning of TPN lighting / AC Distribution board of approved make as per appendix -1, with rating and feeders as per specification. The DB shall be of IP-42 protection class and shall conform to IS 8623. The board shall be \\"fitted with an acrylic door as per specifications and drawings |
| 219 | Type III Distribution Board : Double Door EURODB of Havells or equivalent approved make having bus bar 200 A TPN, 1 Incomer 125 A FP MCB Isolator with 125 A FP RCCB (Senstivity 100 mA) alongwith \\"3 numbers 63 A TPN MCB as per specification |
| 220 | FLAME PROOF FITTINGS - All equipment under this category shall be suitable (minimum requirments) for location in zone-I gas group IIA & IIB (Temp. class T3) area with a separate terminal box for incoming cable and a separate terminal box for out going cable (where applicable), apart from separate enclosure for each equipment including control gear etc. in IP 65 cast aluminium LM-6 certified enclosure: |
| 221 | FLAMEPROOF TUBELIGHT, 2x22Watt, LED, SUITABLE FOR Exd Gas Group II C, as per IS/IEC 60079-2007 |
| 222 | Dismantling & Shifting with Re-Installation Hot Air Oven |
| 223 | Dismantling & Shifting with Re-Installation KV Bath Mannul |
| 224 | Dismantling & Shifting with Re-Installation DME GA Stand |
| 225 | Dismantling & Shifting with Re-Installation Printer |
| 226 | Dismantling & Shifting with Re-Installation ROE (Gum Bath) & Smoke Point |
| 227 | Dismantling & Shifting with Re-Installation Epson Printer (ISL) |
| 228 | Dismantling & Shifting with Re-Installation Refrigerator |
| 229 | Dismantling & Shifting with Re-Installation Silver Bath and accessories |
| 230 | Dismantling & Shifting with Re-Installation Copper Bath |
| 231 | Dismantling & Shifting with Re-Installation PMCC Flash Point Apparatus |
| 232 | Dismantling & Shifting with Re-Installation Abel Flash Point Apparatus |
| 233 | Dismantling & Shifting with Re-Installation Water Bath (Ethanol) |
| 234 | Dismantling & Shifting with Re-Installation ECO Titrator |
| 235 | Dismantling & Shifting with Re-Installation Muffle Furnace |
| 236 | Dismantling & Shifting with Re-Installation Copper, Silver Strip Glass(3+3), Borosil Glass 30ml |
| 237 | Dismantling & Shifting with Re-Installation Fortin's Barometer |
| 238 | Dismantling & Shifting with Re-Installation Dry & Wet Thermo meter |
| 239 | Dismantling & Shifting with Re-Installation Pmcc Flush Point Tester |
| 240 | Dismantling & Shifting with Re-Installation Electrical Balance . |
| 241 | Dismantling & Shifting with Re-Installation Auto Distillation Apparatus & printer (Acute) |
| 242 | Dismantling & Shifting with Re-Installation Auto Coulometer and accessories |
| 243 | Dismantling & Shifting with Re-Installation Auto Density Cum Visco meter |
| 244 | Dismantling & Shifting with Re-Installation UVF Sulphur Analyzer(4Part) Gas Connection Point |
| 245 | Dismantling & Shifting with Re-Installation Wash Basin Stand . |
| 246 | Dismantling & Shifting with Re-Installation Kent RO with Installation & Water Point |
| 247 | Dismantling & Shifting with Re-Installation Auto Distillation Appratuse (ISL) |
| 248 | Dismantling & Shifting with Re-Installation ISL Printer |
| 249 | Dismantling & Shifting with Re-Installation Dessicator |
| 250 | Dismantling & Shifting with Re-Installation CFPP Set |
| 251 | Dismantling & Shifting with Re-Installation Pour Point Bath |
| 252 | Dismantling & Shifting with Re-Installation Auto Abel Flash Point (Acute) |
| 253 | Dismantling & Shifting with Re-Installation Kinematic Viscosity Bath |
| 254 | Dismantling & Shifting with Re-Installation Dual Distillation Apparatus |
| 255 | Dismantling & Shifting with Re-Installation Hydro Meter Set |
| 256 | Dismantling & Shifting with Re-Installation Tharmo Meter Set |
| 257 | Dismantling & Shifting with Re-Installation 50w Led Bulb |
| 258 | Dismantling & Shifting with Re-Installation 15w Led Bulb |
| 259 | Dismantling & Shifting with Re-Installation Led Tube |
| 260 | Dismantling & Shifting with Re-Installation Godrej Almirah and contents |
| 261 | Dismantling & Shifting with Re-Installation UPS |
| 262 | Dismantling & Shifting with Re-Installation DB Box Dismantling |
| 263 | Dismantling & Shifting with Re-Installation DB Box Installtion |
| 264 | Dismantling & Shifting with Re-Installation Table Granite |
| 265 | Dismantling & Shifting with Re-Installation Watch |
| 266 | Dismantling & Shifting with Re-InstallationCeiling Fan |
| 267 | Dismantling & Shifting with Re-Installation File Rack |
| 268 | Dismantling & Shifting with Re-Installation File Almirha |
| 269 | Dismantling & Shifting with Re-Installation Wooden Desk |
| 270 | Dismantling & Shifting with Re-Installation Chair |
| 271 | Dismantling & Shifting with Re-Installation Computer Dask |
| 272 | Dismantling & Shifting with Re-Installation PC Set Installation with all Connection |
| 273 | Dismantling & Shifting with Re-Installation Printer for PC |
| 274 | Dismantling & Shifting with Re-Installation Self Stand |
| 275 | Dismantling & Shifting with Re-Installation First Aid Box |
| 276 | Dismantling & Shifting with Re-Installation Photo Frames |
| 277 | Dismantling & Shifting with Re-Installation White Board |
| 278 | Dismantling & Shifting with Re-Installation Notice Board |
| 279 | CCTV Dismantling |
| 280 | CCTV Installation |
| 281 | Dismantling & Shifting with Re-Installation DCP 10kg |
| 282 | Dismantling & Shifting with Re-Installation CO2 Extinguisher |
| 283 | Supply & Laying with connection of 4 mm wire for Power point |
| 284 | Supply & Laying with connection of 2.5 mm wire for Power point |
| 285 | Supply & Laying with connection of 1 mm wire for Power point |
| 286 | Dismantling of Split AC |
| 287 | Installation of Split AC |
| 288 | Dismantling & Connection of Electrical Board & Equipment with direction of lab engineer etc. |
| 289 | Charges for dismantling, shifting and re-installation of TEI, TS Analyser |
| 290 | Design, supply and installation Spot Extractor furniture in QC lab with following component:-Spot Extractor (Alsident): Arm: System 75 - Aluminium: 75-6555-3-5, Ceiling/Wall 650-550 white, Reach- 1230 mm., Dome: System 75 - 1-7535-5 , Hood 75-350/white flange - Hood transparent , Ø 385 flange white with Aluminium Stub., Spot Extractor Ceiling Column:, 1750 mm long GI Powder Coated Ceiling Column.All work shall be carried out as directed by the Engineer-in-Charge. Any item required for complete installation of the laboratory furniture, whether specified or not, shall be deemed included in the bidder's scope at no extra cost |
| 291 | Design, supply and installation of L shape bench along wall 4305+4006 L X920D X 900H with SS sink and 3 way faucet furniture in QC lab with following component: of L shape bench along wall 4305+4006 L X920D X 900H with SS sink and 3 way faucet, R.H. 900 Ht.C-Frame Assy. For Table Depths 1840 Island Witout Upright & 920 Wall Side Without Upright L.H. 900 Ht.C-Frame Assy. For Table Depths 1840 Island Witout Upright & 920 Wall Side Without Upright Common 900 Ht.C-Frame Assy. For Table Depths 1840 Island Witout Upright & 920 Wall Side Without Upright 900 Ht. Corner C-Frame Table, 1500 Module Length Horizontal Members, 1350 Module Length Horizontal Members 920 Depth Wall Side Without Upright, Outer Cover For Single-Sided Electrical Trunking, Industrial Socket : 20A/240V 1 Phase - 3 Pin Socket , (Cat No.: PS16BA7), Industrial Plug : 20A/240V 1 Phase - 3 Pin Plug ,(Cat No.: PS16AA7) Single Pole MCB, 1 Module Plate - Model No: Cs911M, 750 Module Length Single Side Electrical Trunking - Cutouts: 1Module +1Module, 1500 Module Length Single Side Electrical Trunking - Cutouts: 1Module + 1Module + 1Module 1350 Module Length Single Side Electrical Trunking - Cutouts: 1Module + 1Module + 1Module, WFU-SU-2S-750W-635H, WFU-C-SU-900-1S-RH-635H, WFU-2S-1D-750W-635H, WFU-2S-1D-600W-635HSs Sink, Rek 1916, 3 Way Water Faucet Bench Mounted, 8\\"\\" Swing Gooseneck Model No. 100/32, Jet Black Granite (Sq.Mt.) 20 (±2) Mm Thk, Silicon Sealant - Black, Masking Tape, 6MM Self Adhesive Natural Rubber Strip, Flexible/F Serated Connector Model : Hp 01 Make: Premier, Anti-Siphon Bottle Trap Model : S 04 Make: PremierAll work shall be carried out as directed by the Engineer-in-Charge. Any item required for complete installation of the laboratory furniture, whether specified or not, shall be deemed included in the bidder's scope at no extra cost |
| 292 | Design, supply and installation of wall bench along wall 3880LX920D X900H furniture in QC lab with following component:-R.H. 900 Ht.C-Frame Assy. For Table Depths 1840 Island Witout Upright & 920 Wall Side Without UprightL.H. 900 Ht.C-Frame Assy. For Table Depths 1840 Island Witout Upright & 920 Wall Side Without UprightCommon 900 Ht.C-Frame Assy. For Table Depths 1840 Island Witout Upright & 920 Wall Side Without Upright750 Module Length Horizontal Members, 500 Module Length Horizontal Members, 920 Depth Wall Side Without Upright, Outer Cover For Single-Sided Electrical Trunking, Industrial Socket : 20A/240V 1 Phase - 3 Pin Socket (Cat No.: PS16BA7), Industrial Plug : 20A/240V 1 Phase - 3 Pin Plug , (Cat No.: PS16AA7), Single Pole MCB1 Module Plate - Model No: Cs911M, 750 Module Length Single Side Electrical Trunking - Cutouts: 1Module +1Module 1500 Module Length Single Side Electrical Trunking - Cutouts: 1Module + 1Module + 1Module, WFU-2S-1D-750W-635H, Jet Black Granite (Sq.Mt.) 20 (±2) Mm Thk, Silicon Sealant - Black, Masking Tape6MM Self Adhesive Natural Rubber StripAll work shall be carried out as directed by the Engineer-in-Charge. Any item required for complete installation of the laboratory furniture, whether specified or not, shall be deemed included in the bidder's scope at no extra cost |
| 293 | Design, supply and installation of Wall Benche along wall 1580 L X 920 D X 900 H furniture in QC lab with SS sink and 3 way faucet with following component :R.H. 900 Ht.C-Frame Assy. For Table Depths 1840 Island Witout Upright & 920 Wall Side Without UprightL.H. 900 Ht.C-Frame Assy. For Table Depths 1840 Island Witout Upright & 920 Wall Side Without Upright1500 Module Length Horizontal Members, 920 Depth Wall Side Without Upright, WFU-SU-2S-750W-635HSs Sink, Rek 1916, 3 Way Water Faucet Bench Mounted, 8\\"\\" Swing Gooseneck Model No. 100/32Jet Black Granite (Sq.Mt.) 20 (±2) Mm Thk, Silicon Sealant - Black, Masking Tape, 6MM Self Adhesive Natural Rubber Strip, Flexible/F Serated Connector Model : Hp 01 Make: Premier, Anti-Siphon Bottle Trap Model : S 04 Make: PremierAll work shall be carried out as directed by the Engineer-in-Charge. Any item required for complete installation of the laboratory furniture, whether specified or not, shall be deemed included in the bidder's scope at no extra cost |
| 294 | Design, supply and installation of wall top unit of Godrej WT-2S-GS-600W-635H furniture in QC labAll work shall be carried out as directed by the Engineer-in-Charge. Any item required for complete installation of the laboratory furniture, whether specified or not, shall be deemed included in the bidder's scope at no extra cost |
| 295 | Design, supply and installation of MS Apparatus storage cabinet [ with top cover plate ] 900W X 1800H X 560D furniture in QC labAll work shall be carried out as directed by the Engineer-in-Charge. Any item required for complete installation of the laboratory furniture, whether specified or not, shall be deemed included in the bidder's scope at no extra cost |
| 296 | Design, supply and installation of Justrite safety cabinet -45 gallon (170) 8945001-Made of 18 gauge (1mm) Double wall wall steel with 38 mm of insulating air space colour yellow cabinet: Manual closing double door with 2 shelves. Appoval FM-N-O-10 min. Fire rating All work shall be carried out as directed by the Engineer-in-Charge. Any item required for complete installation of the laboratory furniture, whether specified or not, shall be deemed included in the bidder's scope at no extra cost |
| 297 | Design, supply and installation of 8 feet bench top abp Aeolus fume hood slave (working):-8 FEET BENCHTOP ABP AEOLUS FUME HOOD WITHOUT ANY ACCESSORIES AFA 1000/1 FOR AEOLUS FUMEHOOD, Distribution Board With Rocker Switch For Aeolus Fumehood LED LIGHT FOR 7 & 8 FT AEOLUS FUMEHOOD, 3 Module Plate With Socket & Tiny Trip For Aeolus Fume Hood, Apparatus Grid For 8 Feet Benchtop Fumehood (Epoxy), Raw Water (Flexible Tubing Service Valves For Benchtop Aeolus Fumehood) (RHS), Compressed Air (Flexible Tubing Service Valves For Benchtop Aeolus Fumehood) (RHS), Nitrogen (Flexible Tubing Service Valves For Benchtop Aeolus Fumehood) (RHS), Ceiling Front Cover Panel For 8 Feet Aeolus Fumehood Ceiling LH/ RH Side Cover Panel For Aeolus Fumehood, MOBILE APPARATUS STORAGE CABINET FOR BENCH TOP AEOLUS FUME HOOD WITH FRAME BASED UNDERSTRUCTURE 540W MOBILE APPARATUS STORAGE CABINET FOR BENCH TOP AEOLUS FUME HOOD WITH FRAME BASED UNDERSTRUCTURE 840W FRAME BASED UNDERSTRUCTURE FOR 8 FEET BENCH TOP AEOLUS FUMEHOOD WITH NO CUT-OUT ON TRUNKINGBack Panel Set For Frame Based Understructure For 8 Feet Benchtop Aeolus Fumehood SIDE PANEL SET FOR FRAME BASED UNDERSTRUCTURE BENCHTOP AEOLUS FUMEHOOD.All work shall be carried out as directed by the Engineer-in-Charge. Any item required for complete installation of the laboratory furniture, whether specified or not, shall be deemed included in the bidder's scope at no extra cost |
| 298 | Design, supply and installation of 8 feet bench top abp Aeolus fume hood slave (Standby):-8 FEET BENCHTOP ABP AEOLUS FUME HOOD WITHOUT ANY ACCESSORIES AFA 1000/1 FOR AEOLUS FUMEHOOD, Distribution Board With Rocker Switch For Aeolus Fumehood LED LIGHT FOR 7 & 8 FT AEOLUS FUMEHOOD, 3 Module Plate With Socket & Tiny Trip For Aeolus Fume Hood, Apparatus Grid For 8 Feet Benchtop Fumehood (Epoxy), Raw Water (Flexible Tubing Service Valves For Benchtop Aeolus Fumehood) (RHS), Compressed Air (Flexible Tubing Service Valves For Benchtop Aeolus Fumehood) (RHS), Nitrogen (Flexible Tubing Service Valves For Benchtop Aeolus Fumehood) (RHS), Ceiling Front Cover Panel For 8 Feet Aeolus Fumehood Ceiling LH/ RH Side Cover Panel For Aeolus Fumehood, MOBILE APPARATUS STORAGE CABINET FOR BENCH TOP AEOLUS FUME HOOD WITH FRAME BASED UNDERSTRUCTURE 540W MOBILE APPARATUS STORAGE CABINET FOR BENCH TOP AEOLUS FUME HOOD WITH FRAME BASED UNDERSTRUCTURE 840W FRAME BASED UNDERSTRUCTURE FOR 8 FEET BENCH TOP AEOLUS FUMEHOOD WITH NO CUT-OUT ON TRUNKINGBack Panel Set For Frame Based Understructure For 8 Feet Benchtop Aeolus Fumehood SIDE PANEL SET FOR FRAME BASED UNDERSTRUCTURE BENCHTOP AEOLUS FUMEHOOD.All work shall be carried out as directed by the Engineer-in-Charge. Any item required for complete installation of the laboratory furniture, whether specified or not, shall be deemed included in the bidder's scope at no extra cost |
| 299 | Design, supply and installation of wall bench along wall 1580LX920D X900H with FLP shocket with following componenets:-R.H. 900 Ht.C-Frame Assy. For Table Depths 1840 Island Witout Upright & 920 Wall Side Without UprightL.H. 900 Ht.C-Frame Assy. For Table Depths 1840 Island Witout Upright & 920 Wall Side Without Upright1500 Module Length Horizontal Members, 920 Depth Wall Side Without Upright, Outer Cover For Single-Sided Electrical Trunking, Flameproof - Switch Socket 16A, 230V (3 Pin / Single Phase) with Plug - Make: Prateek Explosionproof Pvt. Ltd., Series CAT No.: PE/EXPB/902 Series, CAT No: PE/EXSS/902, 1500 Module Length Single Side Electrical Trunking - Cutouts:, 3 Nos. of FLP Switch Socket, WFU-2S-1D-750W-635H, Jet Black Granite (Sq.Mt.) 20 (±2) Mm Thk, Silicon Sealant - Black, Masking Tape, 6MM Self Adhesive Natural Rubber StripAll work shall be carried out as directed by the Engineer-in-Charge. Any item required for complete installation of the laboratory furniture, whether specified or not, shall be deemed included in the bidder's scope at no extra cost |
| 300 | Design, supply and installation of MS centrifugal Blower & accessories cluster 01- 2 nos. 8 ft fumehood+01 nos. Justrite Cabinet +7 Nos. of spot extractor with GI powder coating ducring with following component:-MS Exhaust Blower 3 HP,FLP Motor,1440 RPM,2500 CFM @ 80 to 100 Static 1 Nos, GI Powder Coated Blower Weather Cowl and MS Stack Support 1Nos, GI Powder Coated 12'' Bypass Damper with 2 Side Flange 1Nos Supply and Installation of GI Duct with Accessories GI Powder Coated Ducting GI 4\\" Flexible Hose 20 RFTGI 10\\" Flexible Hose 20 RFTGI 4\\" Manual Damper 8 RFTGI 10\\" Manual Damper 4 RFTGI 4\\" Duct 32 RFTGI 8\\" Duct 56 RFTGI 10\\" Duct 42 RFTGI 20\\" Duct 38 RFT 8\\" - 10\\" Inch Reducer 1 NosGI 4\\" Inch 45 Deg Bend 8 NosGI 10\\" Inch 45 Deg Bend 5 NosGI 10\\" Inch 90 Deg Bend 1 NosGI 20\\" Inch 90 Deg Bend 2 Nos12'' Dia PP Damper with Actuator and Instrumentation 1 SetInstallation & Freight Charges 1 LotAll work shall be carried out as directed by the Engineer-in-Charge. Any item required for complete installation of the laboratory furniture, whether specified or not, shall be deemed included in the bidder's scope at no extra cost |
| 301 | Supply and installation of furniture unitized PLT 8 seater conference table size (23560X1150X740) |
| 302 | Supply and installation of furniture enterprises table of size (1500X750X728) w/o CPU hanger |
| 303 | Supply and installation furniture T-25 table with integrated HDU of size (1800W X 750DX750H) |
| 304 | Supply and installation furnitureThrill Fabric Highback chair |
| 305 | Supply and installation furnitureThrill Fabric visitor chair |
| 306 | Supply and installation furniture lounge L-42 2 seater chair |
| 307 | Supply and installation furniturej multiflex rack of size (8\\"X36\\"x18\\") |
| 308 | Supply and installation furniture Arbor coffee table |
| 309 | Work of Dismantling, Loading, Transportation, unloading and installation of laboratory furniture, Approximately 50ftX2.5ftX3ft, along with other miscellaneous furniture (Table, Chairs, balance table, steel cabinet, etc.) from IOCL Una Terminal(Himachal Pradesh) to IOCL Barauni Terminal (Bihar). The dismantling and re-installation of all above furniture shall be carried out through the OEM, M/s Godrej to ensure the safe handling and proper installation. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysSep 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender