Tender For Repair / Maintenance Of Dg Sets And Connected Works At Nts, Nad, Dad, Marcos, Chouldhari, Prothrapur, Filtration Plant And Port Mout Under Age E/M-Ii Of Ge Minniebay, Sri Vijaya Puram (8846/E8)
Tender Value
42 Lakhs
Estimated cost
Bid Submission
12 Sep 2026
20 days left
EMD
84000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
South Andamans → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Maintenance Of Dg Sets And Connected Works At Nts, Nad, Dad, Marcos, Chouldhari, Prothrapur, Filtration Plant And Port Mout Under Age E/M-Ii Of Ge Minniebay, Sri Vijaya Puram (8846/E8)
BOQ
| Sl. No. | Item Description |
| 1 | M & L for Inspection and carrying out B-Checks of DG Set Once in 300 Hours of run or 6 months whichever is earlier installed at various locations by Authorised OEM of the DG Set of capacity 500 KVA including inspection, maintenance, changing lub oil filters, fuel filters, by pass filter and water filter and servicing of DG Sets for routine check-up including routine / preventive maintenance checks, checking up of engine and alternator for the smooth functioning as per the Manufacturer’s instructions including checking of Engine Oil Level, Draining Sediments from Fuel Tank, checking of Pre Cleaner Dust Pan, Air Cleaner Restriction, Coolant Level, Recording Oil Pressure, Checking / Tightening of all Bolts / Nuts of Engine and Alternator, checking of AVM Pads, Diaphragm Coupling, Air Piping, check / adjust Belts, checking Battery Voltage, Water Level and checking Fan Hub and Water Pump, cleaning of electrical connections, checking of safety controls, cleaning of Engine including cleaning of Air Filter, Screws etc. and draining out old engine oil from oil chamber and removing deposited material including tightening of all inlet and outlet connections and replacing minor items such as detoriated clamp, screws, washers etc complete all as specified and as directed.Note: (a) Contractor have to submit letter of Authoried OEM and take approval from Engr-in-charge.The B Check includes carrying out preventive maintenance including replacing lub oil filters, fuel filters, fuel water seperator, by pass filter and coolant filter to keep the DG set for trouble free functioning. The rate quoted is deemed to be including all the minor spares such as screws, clips,washers, etc. The engine oil and coolant will be measured and paid seperately as supply only under relevant items of this schedule.(b) Supply of Engine oil and Coolant shall be supplied and paid seperately from relevant schedule item. |
| 2 | M & L for Inspection and carrying out B-Checks of DG Set Once in 300 Hours of run or 6 months whichever is earlier installed at various locations by Authorised OEM of the DG Set of capacity 250 KVA including inspection, maintenance, changing lub oil filters, fuel filters, by pass filter and water filter and servicing of DG Sets for routine check-up including routine / preventive maintenance checks, checking up of engine and alternator for the smooth functioning as per the Manufacturer’s instructions including checking of Engine Oil Level, Draining Sediments from Fuel Tank, checking of Pre Cleaner Dust Pan, Air Cleaner Restriction, Coolant Level, Recording Oil Pressure, Checking / Tightening of all Bolts / Nuts of Engine and Alternator, checking of AVM Pads, Diaphragm Coupling, Air Piping, check / adjust Belts, checking Battery Voltage, Water Level and checking Fan Hub and Water Pump, cleaning of electrical connections, checking of safety controls, cleaning of Engine including cleaning of Air Filter, Screws etc. and draining out old engine oil from oil chamber and removing deposited material including tightening of all inlet and outlet connections and replacing minor items such as detoriated clamp, screws, washers etc complete all as specified and as directed.Note: (a) Contractor have to submit letter of Authoried OEM and take approval from Engr-in-charge.The B Check includes carrying out preventive maintenance including replacing lub oil filters, fuel filters, fuel water seperator, by pass filter and coolant filter to keep the DG set for trouble free functioning. The rate quoted is deemed to be including all the minor spares such as screws, clips,washers, etc. The engine oil and coolant will be measured and paid seperately as supply only under relevant items of this schedule.(b) Supply of Engine oil and Coolant shall be supplied and paid seperately from relevant schedule item. |
| 3 | M & L for Inspection and carrying out B-Checks of DG Set Once in 300 Hours of run or 6 months whichever is earlier installed at various locations by Authorised OEM of the DG Set of capacity 200 KVA including inspection, maintenance, changing lub oil filters, fuel filters, by pass filter and water filter and servicing of DG Sets for routine check-up including routine / preventive maintenance checks, checking up of engine and alternator for the smooth functioning as per the Manufacturer’s instructions including checking of Engine Oil Level, Draining Sediments from Fuel Tank, checking of Pre Cleaner Dust Pan, Air Cleaner Restriction, Coolant Level, Recording Oil Pressure, Checking / Tightening of all Bolts / Nuts of Engine and Alternator, checking of AVM Pads, Diaphragm Coupling, Air Piping, check / adjust Belts, checking Battery Voltage, Water Level and checking Fan Hub and Water Pump, cleaning of electrical connections, checking of safety controls, cleaning of Engine including cleaning of Air Filter, Screws etc. and draining out old engine oil from oil chamber and removing deposited material including tightening of all inlet and outlet connections and replacing minor items such as detoriated clamp, screws, washers etc complete all as specified and as directed.Note: (a) Contractor have to submit letter of Authoried OEM and take approval from Engr-in-charge.The B Check includes carrying out preventive maintenance including replacing lub oil filters, fuel filters, fuel water seperator, by pass filter and coolant filter to keep the DG set for trouble free functioning. The rate quoted is deemed to be including all the minor spares such as screws, clips,washers, etc. The engine oil and coolant will be measured and paid seperately as supply only under relevant items of this schedule.(b) Supply of Engine oil and Coolant shall be supplied and paid seperately from relevant schedule item. |
| 4 | M & L for Inspection and carrying out B-Checks of DG Set Once in 300 Hours of run or 6 months whichever is earlier installed at various locations by Authorised OEM of the DG Set of capacity 125 KVA including inspection, maintenance, changing lub oil filters, fuel filters, by pass filter and water filter and servicing of DG Sets for routine check-up including routine / preventive maintenance checks, checking up of engine and alternator for the smooth functioning as per the Manufacturer’s instructions including checking of Engine Oil Level, Draining Sediments from Fuel Tank, checking of Pre Cleaner Dust Pan, Air Cleaner Restriction, Coolant Level, Recording Oil Pressure, Checking / Tightening of all Bolts / Nuts of Engine and Alternator, checking of AVM Pads, Diaphragm Coupling, Air Piping, check / adjust Belts, checking Battery Voltage, Water Level and checking Fan Hub and Water Pump, cleaning of electrical connections, checking of safety controls, cleaning of Engine including cleaning of Air Filter, Screws etc. and draining out old engine oil from oil chamber and removing deposited material including tightening of all inlet and outlet connections and replacing minor items such as detoriated clamp, screws, washers etc complete all as specified and as directed.Note: (a) Contractor have to submit letter of Authoried OEM and take approval from Engr-in-charge.The B Check includes carrying out preventive maintenance including replacing lub oil filters, fuel filters, fuel water seperator, by pass filter and coolant filter to keep the DG set for trouble free functioning. The rate quoted is deemed to be including all the minor spares such as screws, clips,washers, etc. The engine oil and coolant will be measured and paid seperately as supply only under relevant items of this schedule.(b) Supply of Engine oil and Coolant shall be supplied and paid seperately from relevant schedule item. |
| 5 | M & L for Inspection and carrying out B-Checks of DG Set Once in 300 Hours of run or 6 months whichever is earlier installed at various locations by Authorised OEM of the DG Set of capacity 100 KVA including inspection, maintenance, changing lub oil filters, fuel filters, by pass filter and water filter and servicing of DG Sets for routine check-up including routine / preventive maintenance checks, checking up of engine and alternator for the smooth functioning as per the Manufacturer’s instructions including checking of Engine Oil Level, Draining Sediments from Fuel Tank, checking of Pre Cleaner Dust Pan, Air Cleaner Restriction, Coolant Level, Recording Oil Pressure, Checking / Tightening of all Bolts / Nuts of Engine and Alternator, checking of AVM Pads, Diaphragm Coupling, Air Piping, check / adjust Belts, checking Battery Voltage, Water Level and checking Fan Hub and Water Pump, cleaning of electrical connections, checking of safety controls, cleaning of Engine including cleaning of Air Filter, Screws etc. and draining out old engine oil from oil chamber and removing deposited material including tightening of all inlet and outlet connections and replacing minor items such as detoriated clamp, screws, washers etc complete all as specified and as directed.Note: (a) Contractor have to submit letter of Authoried OEM and take approval from Engr-in-charge.The B Check includes carrying out preventive maintenance including replacing lub oil filters, fuel filters, fuel water seperator, by pass filter and coolant filter to keep the DG set for trouble free functioning. The rate quoted is deemed to be including all the minor spares such as screws, clips,washers, etc. The engine oil and coolant will be measured and paid seperately as supply only under relevant items of this schedule.(b) Supply of Engine oil and Coolant shall be supplied and paid seperately from relevant schedule item. |
| 6 | M & L for Inspection and carrying out B-Checks of DG Set Once in 300 Hours of run or 6 months whichever is earlier installed at various locations by Authorised OEM of the DG Set of capacity 82.50 KVA including inspection, maintenance, changing lub oil filters, fuel filters, by pass filter and water filter and servicing of DG Sets for routine check-up including routine / preventive maintenance checks, checking up of engine and alternator for the smooth functioning as per the Manufacturer’s instructions including checking of Engine Oil Level, Draining Sediments from Fuel Tank, checking of Pre Cleaner Dust Pan, Air Cleaner Restriction, Coolant Level, Recording Oil Pressure, Checking / Tightening of all Bolts / Nuts of Engine and Alternator, checking of AVM Pads, Diaphragm Coupling, Air Piping, check / adjust Belts, checking Battery Voltage, Water Level and checking Fan Hub and Water Pump, cleaning of electrical connections, checking of safety controls, cleaning of Engine including cleaning of Air Filter, Screws etc. and draining out old engine oil from oil chamber and removing deposited material including tightening of all inlet and outlet connections and replacing minor items such as detoriated clamp, screws, washers etc complete all as specified and as directed.Note: (a) Contractor have to submit letter of Authoried OEM and take approval from Engr-in-charge.The B Check includes carrying out preventive maintenance including replacing lub oil filters, fuel filters, fuel water seperator, by pass filter and coolant filter to keep the DG set for trouble free functioning. The rate quoted is deemed to be including all the minor spares such as screws, clips,washers, etc. The engine oil and coolant will be measured and paid seperately as supply only under relevant items of this schedule.(b) Supply of Engine oil and Coolant shall be supplied and paid seperately from relevant schedule item. |
| 7 | M & L for Inspection and carrying out B-Checks of DG Set Once in 300 Hours of run or 6 months whichever is earlier installed at various locations by Authorised OEM of the DG Set of capacity 62.50 KVA including inspection, maintenance, changing lub oil filters, fuel filters, by pass filter and water filter and servicing of DG Sets for routine check-up including routine / preventive maintenance checks, checking up of engine and alternator for the smooth functioning as per the Manufacturer’s instructions including checking of Engine Oil Level, Draining Sediments from Fuel Tank, checking of Pre Cleaner Dust Pan, Air Cleaner Restriction, Coolant Level, Recording Oil Pressure, Checking / Tightening of all Bolts / Nuts of Engine and Alternator, checking of AVM Pads, Diaphragm Coupling, Air Piping, check / adjust Belts, checking Battery Voltage, Water Level and checking Fan Hub and Water Pump, cleaning of electrical connections, checking of safety controls, cleaning of Engine including cleaning of Air Filter, Screws etc. and draining out old engine oil from oil chamber and removing deposited material including tightening of all inlet and outlet connections and replacing minor items such as detoriated clamp, screws, washers etc complete all as specified and as directed.Note: (a) Contractor have to submit letter of Authoried OEM and take approval from Engr-in-charge.The B Check includes carrying out preventive maintenance including replacing lub oil filters, fuel filters, fuel water seperator, by pass filter and coolant filter to keep the DG set for trouble free functioning. The rate quoted is deemed to be including all the minor spares such as screws, clips,washers, etc. The engine oil and coolant will be measured and paid seperately as supply only under relevant items of this schedule.(b) Supply of Engine oil and Coolant shall be supplied and paid seperately from relevant schedule item. |
| 8 | M & L for Inspection and carrying out B-Checks of DG Set Once in 300 Hours of run or 6 months whichever is earlier installed at various locations by Authorised OEM of the DG Set of capacity 20/25 KVA including inspection, maintenance, changing lub oil filters, fuel filters, by pass filter and water filter and servicing of DG Sets for routine check-up including routine / preventive maintenance checks, checking up of engine and alternator for the smooth functioning as per the Manufacturer’s instructions including checking of Engine Oil Level, Draining Sediments from Fuel Tank, checking of Pre Cleaner Dust Pan, Air Cleaner Restriction, Coolant Level, Recording Oil Pressure, Checking / Tightening of all Bolts / Nuts of Engine and Alternator, checking of AVM Pads, Diaphragm Coupling, Air Piping, check / adjust Belts, checking Battery Voltage, Water Level and checking Fan Hub and Water Pump, cleaning of electrical connections, checking of safety controls, cleaning of Engine including cleaning of Air Filter, Screws etc. and draining out old engine oil from oil chamber and removing deposited material including tightening of all inlet and outlet connections and replacing minor items such as detoriated clamp, screws, washers etc complete all as specified and as directed.Note: (a) Contractor have to submit letter of Authoried OEM and take approval from Engr-in-charge.The B Check includes carrying out preventive maintenance including replacing lub oil filters, fuel filters, fuel water seperator, by pass filter and coolant filter to keep the DG set for trouble free functioning. The rate quoted is deemed to be including all the minor spares such as screws, clips,washers, etc. The engine oil and coolant will be measured and paid seperately as supply only under relevant items of this schedule.(b) Supply of Engine oil and Coolant shall be supplied and paid seperately from relevant schedule item. |
| 9 | Attending the breakdown of any capacity/make DG Sets, AMF Panels by Technician & helper for checking all components and rectify the fault and give report to concern JE complete all as directed by Engr-in-charge. Note :- Spare Parts for rectify the fault is measured and paid seperately. |
| 10 | M & L for supply, fixing of Air filter of 500 KVA DG set all as specified and directed by Engineer-in-charge. Make : Cummins |
| 11 | M & L for supply, fixing of Air filter of 320 KVA DG set all as specified and directed by Engineer-in-charge make : Cummins |
| 12 | M & L for supply , fixing of Air filter of 250 KVA / 200 KVA DG set all as specified and directed by Engineer-in-charge Make: Kirloskar/Cummins/Greaves |
| 13 | M & L for supply , fixing of Air filter of 125 KVA DG set all as specified and directed by Engineer-in-charge Make: Kirloskar/Cummins/Greaves/Kirloskar |
| 14 | M & L for supply , fixing of Air filter of 20/25/62.5/82.5/100 DG set all as specified and directed by Engineer-in-charge Make: Kirloskar/Cummins/Greaves |
| 15 | S & fixing in repair water pump assly in 500 /250/200 KVA DG set of complete all as specified and as directed.Make Cummins / Kirloskar |
| 16 | S & fixing in repair water pump assly in 20 / 62.5 / 82.5 / 125 / 160 KVA DG set make Cummins / Kirloskar / Greaves |
| 17 | Supply only engine oil for DG set grade oil 20W40 complete all as directed Make : I O C Servo |
| 18 | Supply only engine oil for DG set grade oil 15W40 complete all as directed Make : I O C Servo |
| 19 | Supply only coolant for radiator of DG set of any capacity of DG set make: Cummins / Kirloskar / Greaves |
| 20 | Supply only distilled water for radiator and batteries of DG set of complet all as specified and as directed. |
| 21 | Supply only DEF Oil for DG set of complet all as specified and as directed. |
| 22 | M & L for repair and reconditioning the starting motor 12 V DC system including taking out the defective starter from 20 KVA -160 KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes with holder, bushes, commutator unit, starting coil, etc refixing the same in the DG set and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-charge |
| 23 | M & L for repair and reconditioning the starting motor 24 V DC system of kirloskar make including taking out the defective starter from 500 KVA / 320 / 250/ 200 KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes with holder, bushes, starting coil, etc refixing the same in the DG set and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-charge |
| 24 | Dismantling the battery charge alternator 12 V DC from engine, carryingout repairs by complete dismantling and cleaning, renewal of carbon brushes, rectifier kit, diodes, varnishing the coils, replacing bearing, regulator, fixing back in the engine and connecting electrical system complete of 20/ 62.5 / 82.5 KVA / 125 KVA DG set all as specified and directed by Engineer-in-charge |
| 25 | Dismantling the battery charge alternator 24 V DC from engine, carryingout repairs by complete dismantling and cleaning, renewal of carbon brushes, rectifier kit, diodes, varnishing the coils, replacing bearing, regulator, fixing back in the engine and connecting electrical system complete of 200/ 250 / 320 / 500 KVA DG set all as specified and directed by Engineer-in-charge |
| 26 | M & L for repair and servicing in PT fuel pump of 200 / 250 / 320 / 500 KVA DG set by taking out the defective defective fuel pump, renewing the worn out parts, seals, o rings, governor weight carriers, carryingout repair and calibration of PT fuel pump and fixing back in the engine and testing on load all as directed by Engineer-in-Charge |
| 27 | M & L for supply, fixing in fuel pump of 20 /62.5/82.5/125/160 KVA DG set by taking out the defective defective fuel pump, renewing the worn out parts, seals, o rings, governor weight carriers, carryingout repair and calibration of fuel pump and fixing back in the engine and testing on load all as directed by Engineer-in-Charge |
| 28 | M & L for supply, installation and commissioning of AVR in 20 /25 /62.5/82.5/125/160 KVA DG set by taking out the defective AVR from DG set alternator from its control circuit, fixing the new AVR and connecting in the circuit, thorough checking and testing the DG set on load all as directed by Engineer-in-Charge. Make Kirloskar / Altex / Senlec |
| 29 | M & L for supply, installation and commissioning of AVR in 200/250/320 KVA DG set by taking out the defective AVR from DG set alternator from its control circuit, fixing the new AVR and connecting in the circuit, thorough checking and testing the DG set on load all as directed by Engineer-in-Charge Make Kirloskar / Altex / Senlec |
| 30 | M & L for supply, fixing AVR for excitation under Cummins AUX 105 / PCC 1302 of 500 KVA by removing the defective unit from alternator and fixing back new and connecting with system and commisioning and testing of complete all as specified and as directed. Make: Cummins/Senlec |
| 31 | S & Fixing the lead acid battery 12 V DC 180 AH including the initial charge, terminals connector of complete all as specified and as directed. Make : Exide / SF / Lucas |
| 32 | S & Fixing the lead acid battery 12 V DC 150 AH including the initial charge, terminals connector of complete all as specified and as directed. Make : Exide / SF / Lucas |
| 33 | S & Fixing the lead acid battery 12 V DC 130 AH including the initial charge, terminals connector of complete all as specified and as directed. Make : Exide / SF / Lucas |
| 34 | M & L for supply and fixing engine fuel hose assly along connector for 200 / 250/ 320/ 500 KVA DG set by taking out the detoriated hoses from engine, replacing and connecting starting and testing all as directed by Engineer-in-charge |
| 35 | M & L for supply and fixing engine Lube oil hose assly along adaptor for 200 /250/320/500 KVA DG set by taking out the detoriated hoses from engine, replacing and connecting starting and testing all as directed by Engineer-in-charge |
| 36 | M & L for supply and fixing engine coolant hose and clamp for 200/250/320/500 KVA DG set by taking out the detoriated hoses from engine, replacing and connecting starting and testing all as directed by Engineer-in-charge |
| 37 | M & L for supply, fixing in repair coil electrical in STC control valve in 500 KVA DG set as specified and directed by Engineer-in-charge |
| 38 | M & L for supply fixing in repairs magnetic pick up suitable for 20 /62.5 /82.5 /125 /200 / 250 KVA DG set by taking out the defective unit from engine , replacing the same and adjusting the gap setting. Connecting in the circuit all as specified as directed by Engineer-in-charge |
| 39 | S & Fixing in repairs Low lub oil pressure safety control in DG set and connecting with DG set system of 20 KVA to 500 KVA all as directed by Engineer-in-Charge |
| 40 | S & Fixing in repairs High water temperature trip safety 20 KVA to 500 KVA DG set and connecting with DG set system all as specifiied and directed by Engineer-in-charge |
| 41 | M & L for supply, fixing fuel oil pressure sensor in 500 KVA DG set all as directed by Engineer-in-Charge |
| 42 | M & L for supply, fixing lub oil pressure sensor in 200 /250 / 320 / 500 KVA DG set all as directed by Engineer-in-Charge |
| 43 | M & L for supply, fixing lub oil pressure sensor in 30 KVA to 125 KVA DG set all as directed by Engineer-in-Charge |
| 44 | M&L for Renewal/replacement of 'V' belts Upto 125 KVA DG Set capacity as per existing size and model complete all as directed by Engr-in-charge. |
| 45 | M&L for Renewal/replacement of 'V' belts above 125 KVA and up to 250 KVA DG Set as per existing size and model complete all as directed by Engr-in-charge. |
| 46 | M&L for Renewal/replacement of 'V' belts for 500 KVA DG Set as per existing size and model complete all as directed by Engr-in-charge. |
| 47 | M&L for Renewal/replacement of fan belts Upto 125 KVA DG Set capacity as per existing size and model complete all as directed by Engr-in-charge. |
| 48 | M&L for Renewal/replacement of fan belts above 125 KVA and up to 250 KVA DG Set capacity as per existing size and model complete all as directed by Engr-in-charge. |
| 49 | M&L for Renewal/replacement of fan belts for 500 KVA DG Set capacity as per existing size and model complete all as directed by Engr-in-charge. |
| 50 | M&L for Renewal/replacement of Dynamo belts Upto 125 KVA DG Set as per existing size and model complete all as directed by Engr-in-charge. |
| 51 | M&L for Renewal/replacement of Dynamo belts above 125 KVA and up to 250 KVA DG Set as per existing size and model complete all as directed by Engr-in-charge. |
| 52 | M&L for Renewal/replacement of Dynamo belts for 500 KVA DG Set as per existing size and model complete all as directed by Engr-in-charge. |
| 53 | M&L disconnecting & removing the unservicable DC wiring from DG set of any type/any make/any model/any capacity and rewiring with the same with suitable new copper wire to existing guage wire by providing flexible pipe including making all electrical connections for satisfactory completion of job & checking of electrical/electronic spares working condtion and testing etc complete all as specified and directed.Note: (i) The rate quoted deemed to be inclusive of new copper wire cost in the unit rate. |
| 54 | S&F in replacement of Line Voltage Monitors (LVMS) of existing make to DG set of 20 KVA to 500 KVA capacity listed parameters including testing complete all as specified and as directed.Make :- OEM recommended |
| 55 | S & Fixing in repair shutdown valve in 200 / 250 / 500 KVA DG set as specified and directed by Engineer-in-charge |
| 56 | S & Fixing in repair and rewinding the excitor stator field assembly of 200 / 250 / 500 KVA by takingout complete burnt coils, cleaning and rewinding the same by supper enamel copper wire, insulalting the coils with nomex paper, milinex sheet, heating and varnshing by varnish materials and applying one coat of bectol anti rust protection, fixing back in to the alternator, connecting teh cables, starting and testing all as specified and directed by Engineer-in-charge |
| 57 | M & L for taking down unserviceable starting motor from the engine 62.5/82.5/100/125/160 KVA and supply and fixing starter assly and connecting with circuit and testing complete all as directed. |
| 58 | Taking out ACB breaker for repair and servicing by disconnecting and dismantling the ACB breaker rating 2000 Amps / 1000 Amps / 800 Amps make L&T by carrying out repair/ servicing , checking and renewing the defective shunt trip coil & UV trip 230 V AC , checking and rectifying the defective CTs and rectifying the mechanism operation including spring charge system, reinstalling the same in the panel and providing necessary line and connections all as directed by Engineer-in-charge. Note item no.46.00 The spare required for repairs / replacement will be measured and paid seperately |
| 59 | Supply only shunt release coil 240 V AC all as per sample and as specified |
| 60 | Supply only Closing coil 240 V AC all as per sample and as specified |
| 61 | Supply only undervoltage coil 240 V AC all as per sample and as specified |
| 62 | Supply only spring charging motor suitable for fixing in ACB of make SIEMENS operated in 240 /415V AC supply all as specified |
| 63 | Supply and fixing in repairs phase indicator lamps R, Y, B LED type of complete all as specified and as directed. |
| 64 | M & L for fixing in repair and commissioning battery charging alternator 12V / 24 V DC in DG sets all as directed . |
| 65 | M & L for taking down unserviceable solenoid switch from starter motor of 200 / 250 / 320 / 500 KVA, opening and removing bunrt defective parts, replacing by new solenoid switch and connecting with contacts and testing complete all as directed by Engineer-in-charge |
| 66 | M&L for Renewal of battery cable leads of copper conductor and with brass lugs terminal, for the 12V, 150/180 /200 AH batteries to self stater as that of existing size and length complete all as directed by Engr-in-charge |
| 67 | S&F battery brass terminal and jelly complete all as specified and directed. |
| 68 | M & L for supply and fixing of Engine display control (Microprocessor based type) by taking out the defective unit from 30 KVA to 500 KVA capacity DG set complete checking the panel and its connection circuit in the panel board, providing prper interlink connection with DG set including all required items, starting and testing all as specified and directed by Engineer-in-charge Make: Cummins / Kirloskar / Deep sea |
| 69 | Painting of diesel generator canophy capacity 30 KVA to 100 KVA by applying with two coat of synthetic enamel paint heat resistant of approved quality and colour by spray painting after preparation of old paint surface including stickering of MES no., DG set details, etc all as specified and directed by Engineer-in-charge |
| 70 | S & Fixing rotating rectifier kit diode set ( 6 nos ) suitable for 500 KVA DG set all as specified and directed by Engineer-in-charge |
| 71 | S & Fixing rotating rectifier kit diode set ( 6 nos ) suitable for 30 KVA to 250 KVA DG set all as specified and directed by Engineer-in-charge |
| 72 | S & Fixing in repairs solenoid on / off switch for FIP fuel pump of DG set capacity 30 KVA to 125 KVA KVA DG set suitable for kirloskar make engine and cooecting with circuit system all as directed by Engineer-in-Charge |
| 73 | Material and labour for carrying out repairs in the Electronic Governor Control (EGC) in 30 KVA to 250 KVA DG set by taking out the defective parts from DG set, fixing new controller in the engine and connecting with circuits, starting and testing the DG set on load complete all as specified and directed . |
| 74 | S&Fixing in repairs of start and stop control PCB control unit suitable for 30 /62.5 / 82.5 /125 KVA DG set make: Cummins / Kirloskar |
| 75 | M & L for supply, installation and commissioning of Actuator in 500 KVA / 250/200 KVA DG set by taking out the defective Actuator from enginet, fixing the new Actuator and connecting in the circuit, thorough checking and testing the DG set on load all as directed by Engineer-in-Charge make: Cummins / Kirloskar |
| 76 | S&Fixing in repairs of low coolant water level sensor suitable for 500 KVA DG set all as specified and directed by Engineer-in-charge make: Cummins |
| 77 | M & L for thorough checking and cleaning of chocked radiator of 500 KVA by applying suitable chemical liquid, cleaning detergents by taking care of tubes and fins, opening fan guards, removing deposited sludges, oil wet and carbons from fins, refixing all removed items back and starting and testing of DG set on load all as specified and directed by Engineer-in-charge |
| 78 | S & fixing alternator terminal connector in 200/250/320 KVA by taking out the burnt connector from alternator, checking cable lugs and connecting in the new terminal and tightening and testing at NTS power house all as specified and directed by Engineer-in-charge. |
| 79 | S & fixing alternator terminal connector in 30 KVA to 160 KVA by taking out the burnt connector from alternator, checking cable lugs and connecting in the new terminal and tightening and testing at NTS power house all as specified and directed by Engineer-in-charge. |
| 80 | S &F Door hinges of any capacity of DG Sets as suitable for existing one as specified and directed.Make Kisloskar |
| 81 | S &F Door lock of any capacity of DG Sets as suitable for existing one as specified and directed.Make Kisloskar |
| 82 | M&L in servicing of alternator capacity 200/250 / 320 KVA by disconnecting from engine coupling system, complete dismantling of stator and rotor seperately, excitors and rotating rectifier units thorough cleaning and decarbonising of stator and rotor coils by CTC liquid, checking and renewing the insulation tapes, heating and improving the insulation of coils as required per the requirements, varnishing the coils and followed by bectol anti rust coating, replacing both bearings, assembling all removed parts in the alternator, fixing back into the engine and coupling and carrying out alignment accurately, connecting the power cables and AVR system, excitation connections, starting and testing on load allas specified and directed by Engineer-in-Charge. |
| 83 | M&L in servicing of alternator capacity 62.5/82.5/125 /160 KVA by disconnecting from engine coupling system, complete dismantling of stator and rotor seperately, excitors and rotating rectifier units thorough cleaning and decarbonising of stator and rotor coils by CTC liquid, checking and renewing the insulation tapes, heating and improving the insulation of coils as required per the requirements, varnishing the coils and followed by bectol anti rust coating, replacing both bearings, assembling all removed parts in the alternator, fixing back into the engine and coupling and carrying out alignment accurately, connecting the power cables and AVR system, excitation connections, starting and testing on load allas specified and directed by Engineer-in-Charge. |
| 84 | M&L for cleaning of fuel tank made of MS sheet up to 20 to 160 KVA DG Sets by draining out fuel in a separate container, taking out all silt / dirt deposition inside the tank, cleaning it completely by manual and necessary T&P and refitting and connecting with fuel pipes complete all as specified and as directed |
| 85 | M&L for cleaning of fuel tank made of MS sheet up to 200 KVA to 500 KVA DG Sets by draining out fuel in a separate container, taking out all silt / dirt deposition inside the tank, cleaning it completely by manual and necessary T&P and refitting and connecting with fuel pipes complete all as specified and as directed |
| 86 | S&F in replacement of 3 pole ML- 4 Contactor, heavy duty with aux contacts 415 Volt all as per existing make and model complete all as specified and directed. |
| 87 | S&F in replacement of 220/415 Volt spare coil suitable for MCX-41 Contactor as per existing make and model complete all as specified and directed. |
| 88 | S&F in replacement of 220/415 Volt spare coil suitable for MCX- 32 / 33 Contactor as per existing make and model complete all as specified and directed. |
| 89 | S&F in replacement of 220/415 Volt spare coil suitable for MNX 45 Contactor as per existing make and model complete all as specified and directed. |
| 90 | S&F in replacement 4 pole MCX 23 contactor heavy duty with aux contacts 415 V, all as per IS, in existing AMF control panel of DG set 82.5 KVA, thorough checking, connecting with the system, testing both Auto and manual mode operation all as specified as directed |
| 91 | S&F in replacement 4 pole MCX 32 / 33 contactor heavy duty with aux contacts 415 V, all as per IS, in existing AMF control panel of DG set 125 KVA, thorough checking, connecting with the system, testing both Auto and manual mode operation all as specified as directed |
| 92 | M & L for supply, installation and commissioning of radiator for 100/125/200 KVA DG set under Cummins including dismantling of old / defective radiator, taking out from DG set base frame, fixing the new radiator assembly, fan and shroud of radiator, connecting cooling pipes inlet and outlet all as directed by Engineer-in-Charge. |
| 93 | S&F in replacement of AMF Logic controller (Microprocessor based type) by taking out the defective unit from 25 / 62.5/ 82.5/100/125 KVA capacity DG set as per existing make and model complete checking the panel and its connection circuit in the panel board, providing prper interlink connection with DG set including all required items, starting and testing all as specified and directed by Engineer-in-charge. |
| 94 | S&F in replacement of AMF Logic controller (Microprocessor based type) by taking out the defective unit from 160/ 200/250/320 KVA capacity DG set as per existing make and model complete checking the panel and its connection circuit in the panel board, providing prper interlink connection with DG set including all required items, starting and testing all as specified and directed by Engineer-in-charge. |
| 95 | S&F in replacement start and stop relay 12 V/24 V DC suitable for AMF Panel capacity of 25 to 320 KVA all as specified and directed. |
| 96 | Dismantling iron sections as in chequred plate and frame work to plates in any size and position all as specified and directed. |
| 97 | S&F Mild steel plates (plain or chequred) plate channels squre cut or notched forming holes , without any attachement incl necessary welding as specified and directed. |
| 98 | M&L for applying two coats of synthetic enamel paint over a coat of red oxide, Zinc chrome primer on steel surfaces of any descrption , over 10cm width or girth, including preparing on new steel surfaces complete all as specified and directed. |
| 99 | M&L for writing MES NO of DG set in white / black colour, minimum 15 letters complete all as specified and directed by Engineer -in - ChargeNote : Min of 15 letters shall be considered as one job |
| 100 | Supply only Rubber insulation Mat 1mx2mx19mm for 125/160/200/250/320 KVA DG Sets for protection same shape and size all as specified and directed by engr-in-charge. |
| 101 | S&F in replacement on load change over switch 415 V, 4 pole, 250 A open execution as per existing make and model suitable equivalent make as per list of make at PS complete all as specified and directed. |
| 102 | S&F in replacement on load change over switch 415 V, 4 pole, 400 A open execution as per existing make and model suitable equivalent make as per list of make at PScomplete all as specified and directed. |
| 103 | Supply only Electric pump 1HP Single Phase for fuel filling tank complete all as specified and directed. |
| 104 | Earthing complete with copper earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to copper wire 4.0mm dia by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No. 3 connected to earthing test point all as specified 20×3mm copper strip as earthing lead |
| 105 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate notless'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysSep 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender