Tender For Renovation Of Weight Lift Hall In Anna Stadium At Nagercoil In Kanniyakumari District.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of Brick / stone masonry in Cement mortar walls under 3m high |
| 2 | Clean removal of Cement plaster from walls etc complete. |
| 3 | Chipping the concrete and roughening the surfaces etc complete. |
| 4 | Brick work in Cement Mortar 1:6 (one cement and six crushed stone sand) using best quality Burnt Clay Brick of size 8 3/4\\" x 4 1/4\\" x 2 3/4\\" with class designation of 7.5 conforming to IS 1077-1992 including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge. In Foundation and Basement |
| 5 | Supplying and fixing mild steel iron grill for Windows Ventilators and grill gate etc.,complete complying with standard specification. The type design for the grills should be got approved by the departmental officers before execution. |
| 6 | UPVC Window Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work |
| 7 | Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals.Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside.Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam. Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. |
| 8 | Supplying and fixing Hydraulic Door closer of various sizes of approved quality using Aluminium Extruded section body tubular type universal hydraulic door closer with double speed adjustment like HARDWYN (make) 'GAZEL' (or) equivalent (with ISI Monogram) |
| 9 | Supplying, fabricating, erecting and fixing Calcium Silicate Board False Ceiling upto a ceiling height of 4.5m from floor level. |
| 10 | Providing cornice work for False ceiling ncluding cost of material, labour charges etc, complying with standard specification and as directed by the departmental officers. The rate shall be inclusive of finishing the edges and wall junctions with suitable lipping & cornice |
| 11 | Supplying and fixing with ornamental design wall panelling of 19mm thick BWP plywood and ornamental imported self design flute panell pasted on existing wall surface (approved colour, design). The rate includes cost of materials like wall paper, nails, screw, hinges, fixtures and fastenings etc. cost of labour like carpenter, interior designer, cost of transportation etc. complete complying with standard specification and as directed by the departmental officers. |
| 12 | Supplying and fixing powder coated Aluminium frame with mirror glass fixed on quality of plywood including cost of materials, labour charges and trasportation charges etc complete as directed by the departmental officer. |
| 13 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 14 | Paving the floor with best quality Double charged vitrified Tiles of size 600 x 600 x 8 mm and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 15 | Supplying and fixing rubber cushion floor matt 20mm thick etc., including transportation charges, labour charges for fixing and materials etc. complete as directed by the departmental officers. |
| 16 | Painting Old Plastered Wall Surface with Two finishing coats of ready mixed interior plastic Emulsion paint of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 17 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 18 | GST Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysSep 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer