Tender For Providing Of Sainik Institute At Hisar Mil Stn
Tender Value
5.05 Crore
Estimated cost
Bid Submission
24 Sep 2026
32 days left
EMD
5.77 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hisar → Haryana
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Providing Of Sainik Institute At Hisar Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | \\" BOQ \\" BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : CWE HISAR Name of Work: PROVN OF SAINIK INSTITUTE AT HISAR MIL STN Contract No: CWE/HSR-T-30 OF 2026-27 Bidder Name : GENERAL SUMMARY (SCHEDULE OF WORKS) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # NUMBER # Sl.No. Description of Parts/ Item Item Code / Make No. orQty. Unit Pre Priced Rate (in. Rs.) as Defined by MES Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in Figure TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 3 | Lump sum price worked out by the tenderer for BUILDING WORKS as listed in Schedule ‘A’ Part-I (Ref pre-priced schedule attached separately) |
| 4 | Lump sum price worked out by the tenderer for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-II(Ref pre-priced schedule attached separately) |
| 5 | Lump sum price worked out by the tenderer for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part-III(Ref pre-priced schedule attached separately) |
| 6 | Lump sum price worked out by the tenderer for ROAD, PATH AND CULVERT WORKS as listed in Schedule ‘A’ Part-IV(Ref pre-priced schedule attached separately) |
| 7 | Lump sum price worked out by the tenderer for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part-V(Ref pre-priced schedule attached separately) |
| 8 | Lump sum price worked out by the tenderer for AREA DRAINAGE WORKS as listed in Schedule ‘A’ Part-VI(Ref pre-priced schedule attached separately) |
| 9 | Lump sum price worked out by the tenderer for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-VII(Ref pre-priced schedule attached separately) |
| 10 | Lump sum price worked out by the tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-VIII(Ref pre-priced schedule attached separately) |
| 11 | Lump sum price worked out by the tenderer for SUMMER APPLIANCES as listed in Schedule ‘A’ Part-IX(Ref pre-priced schedule attached separately) |
| 12 | Lump sum price worked out by the tenderer for SITE CLEARANCE, EXCAVATION AND EARTH WORKS as listed in Schedule ‘A’ Part-X(Ref pre-priced schedule attached separately) |
| 13 | Lump sum price worked out by the tenderer for COMPOUND WALL/ FENCING AND GATES as listed in Schedule ‘A’ Part-XI(Ref pre-priced schedule attached separately) |
| 14 | Lump sum price worked out by the tenderer for OPEN AIR PLATFORM as listed in Schedule ‘A’ Part-XI(Ref pre-priced schedule attached separately) |
| 15 | Schedule 'A' Part-XIII(MISCELLANEOUS PARTS) |
| 16 | S&F in repair factory made (SFRC) precasted reinforced cement concrete manhole cover with RCC frame of size 1200x1200mm and cover thickness not less than 50mm of size 1100mm x 1100mm, edge of manhole cover to be locked with 1mm thick MS sheet complete all as specified and directed. |
| 17 | S&F in repair factory made (SFRC) precasted reinforced cement concrete manhole cover as required thickness not less than 50mm of size 700mm x 450mm, edge of manhole cover to be locked with 1mm thick MS sheet complete all as specified and directed. |
| 18 | Brick masonry valve pit of size 60x60x60 cm (internal dimension of chamber incl plastering internal and flash pointing external as the work proceeds in same mortar complete with MS sheet cover handle, packing arrangement,earth worth in any type of soil incl removal to n.exc 50 mtr and paint with 2 coats of synthetic enamelled paint over a coat of red oxide primer to steel surfaces complete all as specified |
| 19 | Brick masonry valve pit of size 105cmx105cmx110 cm (internal dimension of chamber incl plastering internal and flash pointing external as the work proceeds in same mortar complete with MS sheet cover handle, packing arrangement,earth worth in any type of soil incl removal to n.exc 50 mtr and paint with 2 coats of synthetic enamelled paint over a coat of red oxide primer to steel surfaces complete all as specified. |
| 20 | M&L for provision of fire stand of suitable size made out of MS angle iron/channel including PCC and brickwork for making plat from of sand painting with two coats of synthetic red enamelled paint over a coat of red oxide primer and writing \\"FIRE POINT\\" with white enamelled paint as per standard size of letters and including the following:-(i) Galvanised MS bucket 14 ltr capacity - 04 Nos(ii) Fire extinguisher, dry powder, type 6kg (ABC type) - 08 Nos(iii) Fire baster - 03 Nos(iv) Fire hook - 03 Nos |
| 21 | Supply and fix refrigerator, electric driven ( single phase), capacity 460 litres. BEE 5 Star Rated |
| 22 | Supply and fix Desert Cooler electric driven (Single phase) having nominal air flow capacity 4000 Cfm ( or nearest size) ( Steel body) |
| 23 | Supply and lay pipe galvanized, “Medium class”, including fittings 15 mm (1/2”) dia. |
| 24 | S&F LED light fitting 40W, regal batten for LED including ultra bright glass LED Tubelight with very high efficacy, single / double side connection all as specified and directed. |
| 25 | S&F LED light fitting 10 W, regal batten for LED including ultra bright glass LED Tubelight with very high efficacy, single / double side connection all as specified and directed. |
| 26 | S&F LED COB Surface Cylinder 10 W, with low power consumption, Driver Efficiency 85%, IP Standard IP20, Beam Angle 600 very high efficacy, connection all as specified and directed. |
| 27 | S&F LED Wall light, with 10 watt Bulb, including ultra bright glass with very high efficacy, single / double side connection all as specified and directed. |
| 28 | S&F LED strip profile shine 240 LEDs/m LED strip 12 V (with Driver) warm white, high brightness, Energy Efficient single / double side connection all as specified and directed. |
| 29 | Supply & installation,testing and commissioning of 11 KV. 630 Amps having short circuit capacity 21kA/3-1 sec, indoor (IP 3X), RMU (Ring Main Unit) 5-way comprising of 02 Nos manually operated Load Break Switches and 03 Nos 630 Amp Fixed-Type spring-charging VCBs, electrolytic grade copper bus bars all inside single, gas-filled, robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank with minimum thickness 2.5 mm, IP 67 Degree of Protection, internal arc classified 21kA/1sec as per IEC 62271-200. The enclosure shall have pad lockable double-door access with anti-theft hinges, fully covering the front facia and cable boxes to ensure fail-safe anti-theft protection. The unit shall include the following along with all necessary accessories and fittings as required at site.(A) 02 No's Incoming Load Break Switches module each consisting of following accessories.(i) Each switching-unit shall be designed as a three position switch. This three function switch combines the functions of switch-disconnector and earthing switch.(ii) 11kV, 630A Load Break Switch with interlocked line-earthing scheme both short circuit current - 21kA/3-sec, Making Capacity 50kA - 01 No(iii) Auxiliary contacts 1NO+1NC - 01 No (iv) Spring-assisted snap-action manual mechanism with un-inhibited operating shaft for emergency manual operation with integrated earthing switch - 01 No (v) Cable terminals with door arrangement for enhanced safety (IP3X) interlocked to prevent access upto 11 KV, 300 Sqmm, 3 Core, XLPE cable termination in live condition Each Set of 03. (vi) Right angle boots (push on type): Each Set of 03 (vii) Arc proof cable covers having cable entry from bottom, front with Interlocking mechanism including earth switch - 01 No (viii) Capacitive voltage indication fixed type system as per IEC 61243 with LED - 01 Set (ix) Fault Passage Indicator - It shall be provided for each incomer load break unit, FPI with LED/digital display to be added for detection of cable fault - 01 No (x) ON, OFF, EARTH mechanical indication on the front mimic of the panel - 01 No |
| 30 | (B) 03 Nos. Outgoing VCB module each consisting of following accessories. (i) Each function-unit consists of a vacuum-circuit breaker in combination with a three position-switch. The three-position-switch fulfills the operation of the disconnector-function and earthing function. (ii) 11kV, 630A Fixed-Type VCB module with series disconnector cum earthing switch of short circuit breaking current/withstand - 21kA/3-sec, Making Capacity - 50kAp - 01 No (iii) Aux. contacts 1NO+1NC - 01 No (iv) Stored-energy manual high-endurance spring charging mechanism (M1+), with inbuilt spring-charging lever and mechanically latched ON/OFF push-buttons to allow un-inhibited operation - 01 No (v) Cable terminals with door arrangement for enhanced safety (IP3X) interlocked to prevent access upto 11KV, 185 Sqmm, 3 Core, XLPE cable termination in live-condition - Set of 3 (vi) Right angle boots (push on type) - Set of 3 (vii) Associated ring-core cast-resin insulated CTs 50/1 Amp 2.5 VA, 5P10 for protection - Each Set of 3 (vii) O/C + IE/F self powered numerical protection relay with Low and High set for over current and Earth Fault. Relay shall have the facility to display the maximum loaded phase current also. Relay shall record minimum 5 fault records with time stamping and shall be communicable on MODBUS. (viii) Arc proof cable covers with self Interlocking mechanism with earth switch -01 No (ix) Capacitive voltage indication fixed type system as per IEC 61243 with LED-01 No (x) Mechanically latched buttons for breaker On/Off - 01Set (xi) ON, OFF, TRIP mechanical indication on the front mimic of the panel. (xi) ON, OFF, TRIP mechanical indication on the front mimic of the panel. (C) Additional equipment delivered separately or mounted separately :- (i) Operating Handle for Manual Isolator/Disconnector / Earthing Operation - 01 No (ii) Operation and Maintenance Manual - 01 No, (iii) Installation & Commissioning Manual - 01 No. |
| 31 | Supply and laying double wall corrugated pipe (DWC) conforming to IS 19430 Part - I of size 50mm outer dia and 38 mm inner dia complete all as specified and as directed |
| 32 | Supply and fixing in repair cable route indicator made cast iron 150mm clear hight with 100 mm long embedded in PCC 1:3:6 type C-1 ( using 20mm stone aggregate ) with Letter \\"LT CABLE/HT CABLE\\" suitable inscribed on one CI circular plate welded with angle iron including necessary earth work and two coat of synthetic enamel paint over a coat of red oxide primer on steel surface complete all as specified and directed |
| 33 | Supply , fixing, installing and commissioning of octagonal Hot-Dip Galvanised street light pole 7 mtr long ,Top dia 70mm Bottom dia 130 mm, sheet thickness 3mm and base plate dimensions 200x200x12mm, foundation bolts M19x600 and 1.5 mtr Single arms bracket, 1100 volts grade, including cost of nuts and bolts and all accessories as supplied by the manufature including cost foundation accessories etc, the foundation bolts as per manufactureer design should be hot dipped galvanised pole complete with door locking arrangement, Terminal plate consisting of 2 nos10A, 4 pole natural links including connection etc with suitable connecting arrangement for 2 nos, cost of RCC 1:1.5:3 for foundation of size 0.7m x0.7mx1.8m with minimum 8 nos 12 mm dia longitudinal MS reinforcement rods with rings of 8 mm dia not more than 200mm cement concrete for fixing the pole with labour and material required to complete all as specified and directed . |
| 34 | S&F in replacement 15 W LED bollard light with opal acrylic diffuser , high surge protection, integrated LED driver , high durablity with IP-66 complete all as specified & directed. Make Bajaj Cat part No BGBOM1000 15WLEDWW or equivalent in Crompton, Orient, surya |
| 35 | Supply, installation, commissioning and testing of LT Panel ,LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) CPRI approved, factory assembled ,out door type, weather and vermin proof (Protection Class IP-54) made out of 50mm x 50mm x 5mm angle iron frame and 3.15 mm(for external) and 3.15 mm (for internal) thick MS Sheet CRCA sheet with both side (front and back) hinged , double door opening for external, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint First Quality) over a coat of red oxide primer complete mounted on angle iron 50mm x 50mm x 5 mm legs 45 cm high above GL and 15 cm embedded in ground with and including bocks of PCC 1:2:4 type C1 of block size 30x30x30 cm comprising of the following.(a) Bus bar chamber having 4 nos air insulated Aluminium strip bus bars of rating not less than the 1.5 times the rated capacity of the incomer MCCB, bus bar must be colour coded heat shrinkable as well as outgoings shall have aluminium four pole (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs.(b) Incoming :-(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade, 300 amps rating 4 pole, 50 KA, Adjustable thermal and magnetic release specially fixed for incoming supply with overload ,short circuit and earth fault protection ,adjustable type (Ics=100%Icu).-01 No. (ii) Voltmeter 0-500V with selector switch 96 mm X 96 mm square flush mounted , with three way rotary selector switch-1 No.(iii) Ammeter size 96 mm X 96 mm square dial flush pattern having dual range 500 amp with three way rotary selector switch- 01 no.(iv) Three Nos CTs of suitable ratio (set of three)-01 Set(v) Indicating lamps (R,Y,B) - 01 set of three |
| 36 | (c) Outgoing(i) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade 160 amps rating and 16 KA rupturing capacity, adjustable thermal and fixed magnetic type specially fixed for incoming supply with overload ,short circuit and earth fault protection ,adjustable type (Ics=100%Icu) - 02 No(ii) MCCB 4 pole , LT 415 Volts, 50 Hz AC grade 25 amps rating and 10 KA rupturing capacity, adjustable thermal and fixed magnetic type( Ics=100%Icu). -01 No.(iii) MCB TPN , 415 Volts, 50 Hz AC of capacity 40-63 Amps rating - 1 Nos”(d) Fine wiring with single core copper conductor for instruments / indicating lamps-01 Job.(e) Nature Switch control panelNote:-(i) All incoming/ outgoing cables shall be connected by suitable size gland plate /glands. And All spreader terminals of MCCBs should be connected with extension links (bus bar). Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 32 daysSep 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 34 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender