Tender For Provision Of 24X7 Water Supply System For 1 No Zone Of Attabira Nac
Tender Value
6.52 Crore
Estimated cost
Bid Submission
05 Sep 2026
10 days left
EMD
6.52 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bargarh → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of 24X7 Water Supply System For 1 No Zone Of Attabira Nac
BOQ
| Sl. No. | Item Description |
| 1 | Pumping machinary |
| 2 | Centrifugal Pump ; Providing, erecting and giving test of Centrifugal pump set conforming to IS 9079 operating at 2900 RPM with impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 1.1KV ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type. Pump set shall be suitable for working at various discharge and head requirements. Pump shall be erected on Provided C.C. foundation block with suitable foundation bolts grouted in C.C. foundation block. Pump shall be erected on Provided C.C. foundation block with suitable foundation bolts grouted in C.C. foundation block.(HEAD - 40MTR, DISCHARGE - 58Lps) |
| 3 | 60HP (1W + 1S ) OLD WTP |
| 4 | Supplying all materials, labour, t&p and fixing of PLC Compatable ATV930- VFD , HEAVY DUTY 16 AMP,WITH BREAKING UNIT VFD floor mounted Control Panel made out of 2MM C.R Powder coated sheet & alluminium BusBar interconnected with copper wire and lugsh having 50KA -125A MCCB including spreader link and extended ROM-1No, RYB indicator -1set, digital ammeter- 1 No, digital volt meter- 1No, 4A control (with bypass arrangement) |
| 5 | 60HP (1W + 1S ) OLD WTP (2 nos 55 KW) |
| 6 | Supplying all labour and T&P for providing and laying MS pipe and specials confirming to IS 3589/99 of quality grade FE 410/ GI Pipe (Medium) confirming to specification of following nominal dia and including transportation of pipes and fitting to site etc all complete as per the direction of E.I.C. |
| 7 | 200mm dia M.S.Pipe (6.30mm thick) |
| 8 | 200mm dia M.S. Flange.(12mm thick) |
| 9 | 200mm dia Offset Bend |
| 10 | Supplying all labour and T&P for cutting of following dia MS pipe of following thick in treanches by gas cutter set of pocket etc all complete |
| 11 | 200mm dia |
| 12 | Supplying all labour and T&P for jointing following dia MS pipe up to 8.0mm thick in treanches by electric arc welding & genetator set of pocket etc all complete |
| 13 | Same as cutting(20% Extra) |
| 14 | Fixing cast iron DI Resilient Seated Glandless Sluice Valve of RATING PN - 1.60(IS 14846/2000) with double flanged ends (with wheel) for water works purpose for the following rating & nominal diameters but (including cost of Sluice Valves) Kirloskar/ VAG/Talis/AVK/Hawle/Audco/IVC make or any other approved reputed make |
| 15 | For Installation/Replacement of Sluice Valve in Existing Water Supply Pipe Line & Newly Proposed Pipeline for controlling flow & scouring Purpose. |
| 16 | 200mm Dia Sluice With Hand Wheel & Without bypass arrangements.(P.N 1.6) at Intake |
| 17 | Supply with fitting and fixing of of D.I. Mechanical dismentaling joint for use to main uninterrupted water supply in the pipeline in case of repair of Flow meter as per specification and direction of Enginer - in - charge |
| 18 | 200mm dia |
| 19 | Supply with fitting and fixing of D/F Non Return Valve use at pumping main for preventing the back thrused in the pump as per specification and direction of Enginer - in - charge.(Kirloskar/ VAG/Talis/AVK/Hawle/Audco/IVC make or any other approved reputed make) |
| 20 | 200mm Dia D/F Non Return Valve (P.N 1.6) |
| 21 | Design, Supply, Construction, Testing & Commisioning of Elevated Service Reservoirs (ESR's) above 25mtr staging ht. for all works such as soil investigation , excavation, back filling & Disposal of earth , RCC & PCC of required grade , shuttering, brick work, painting, finishing, connection pipes upto 5m beyond tank structure, valves fittings, expansion joint, expansion bellow, mechanical level indicator, lighting arrestor,etc including supply of all labour and materials tools & plants including testign& commissioning etc all complete as per specification given at section 8 §ion 9 of DTCN and as as per the direction of Engineer-in-charge.Payments willmade as per the price break up schedule given at section 11 of DTCN |
| 22 | Proposed ESR at DMA -3( 400 KL)Staging - 25m |
| 23 | Design, Drawing and Construction of RCC frame structure with brick work wall single stored building for PLC and Chlorination Room with Toilet block complete as per drawing and specification and the direction of Engineer-in-charge |
| 24 | Supplying all materials,labour and T&P and constructing RCC chamber as per P.H. specification and design all complete including RCC Cover Slab(per each) DMA control chamber internal size:-[7.0x1.0x1.5mtr] S/V. |
| 25 | P.H ESTIMATE (PLC & CHLORINATION ROOM)Supplying all materials, labour, T&P and Fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ or ‘P’ trap conforming to IS 2556 : Part 8-2004, to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification. (Seat and cover to be measured and paid for separately) as per specification ,contrator profit & labour cess as per specification and direction of Engineer-in-charge. |
| 26 | Porcelain E.W.C. with P-trap |
| 27 | Supplying all materials, labour, T&P and Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. as per specification including contrator profit & labour cessand direction of Engineer-in-charge |
| 28 | 10 litr pvc low level cistern with fittings |
| 29 | Supplying all materials, labour, T&P and Fixing wash basins with hole for pillar taps conforming to IS 2556 : Part 4-2004 with Cast Iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification and direction of Engineer-in-charge |
| 30 | Porcelain 22\\"x 16\\"(550x400) W.H.B |
| 31 | Supplying all materials, labour, T&P and fitting and fixing CP Health Foucet with 1.0 mtr PVC Tube as per specification including contractor profit & labour cess etc all complete as per the direction of Engineer-in--charge.(Ref :-PH AR-2013(BIB COCK) |
| 32 | CP Health Faucet with 1.0 mtr PVC Tube |
| 33 | Supplying all materials, labour, T&Pmaking fixing of brass Chromium plated screw down stopcocks of the following nominal dia. as per the specification and direction of Engineer-in-Charge. |
| 34 | 15mm dia C.P.angular stop cock |
| 35 | Supplying all materials, Labour, T&P and fixing of Pillar Taps capstan head Screw down,High Pressure, lettered'Hot' and Cold with long screws, shanks and back nuts of the following nominal bore as per specification & direction of Engineer-in-charge. |
| 36 | 15mm dia CP swan neck Pillar cock with spout |
| 37 | Supplying all materials, labour, T&P and fitting and fixing brass screw-down Bib-Cocks(Taps) polished bright conforming to IS:781-1995 of the following nominal size as per specification including contractor profit & labour cess etc all complete as per the direction of Engineer-in--charge. |
| 38 | Supplying all materials, labour, T&P and fixing Ceramic floor tiles using tile 30cm x 30cm or 40cm x 40cm in floor treads or steps and landing on 25mm thick bed of cement mortar (1:1) jointed with neat cement slurry mixed with pigment to matching shades of the tiles including rubbing and polishing ,contractor profit & labour cess all complete as per direction of Engineer-in-Charge. |
| 39 | Supplying all materials, labour, T&P and fixing Ceramic Glazed tiles in dados,skirtting and risers of steps on 12mm thick bed of cement plaster (1:3) jointed with cement slurry mixed pigment to match the shades of the tiles including rubbing and polishing etc. Complete after providing a base plaster of 12mm thick in cement mortar (1:4) using tiles of size 20cmx20cm or 20cmx30cm including cost of tiles ,conveyance, taxes ,contractor profit & labour cess etc all complete as per the specification and the direction of engineer-in-charge.(tiles of approved shades to be used) |
| 40 | Supplying , fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. |
| 41 | Supplying, fitting & fixing of P.H Fittings & P.V.C. Special etc.all complete as per the direction of Engineer-in-charge.. |
| 42 | C.P. waste (32mm - 5\\" long) |
| 43 | 32mmx 1150mm long PVC waste pipe |
| 44 | Frammed Mirror |
| 45 | Corner Shelf |
| 46 | C.P. towel rail.(600x20)mm |
| 47 | Soap dish /Oval |
| 48 | 110mm dia PVC SWR P Trap |
| 49 | 15mmx600mm PVC connection pipe |
| 50 | 110mm dia PVC SWR plain bend |
| 51 | 110mm dia PVC cowl |
| 52 | 110mm dia PVC SWR Door bend |
| 53 | Providing and fixing to wall or ceiling and floor pvc pipes class conforming to ASTM-D-1785/ 89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor including cost of all materials,conveyance to worksite,contractor profit & labour cess etc all complete and direction of Engineer-in-charge. |
| 54 | 25mm PVC sch-80 pipes |
| 55 | 20mm PVC sch-80 pipes |
| 56 | Supplying & fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position etc all complete as per specification and direction of the Engineer in charge |
| 57 | 1000 litre capacity 3- layer white Rotational Moulded Cylinderical Vertical water storage tank (ISI marked) |
| 58 | Supplying all materials,labour,T&P and laying in trenches unplasticated PVC pipes conforming to IS:4985-2000 and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement bu non-heat application method including testing, contractor profit & labour cess etc as per specification complete (Earth work in trenches to be measured and paid for separately) including cost of pipe,conveyance of pipe to worksite ,contractor profit & labour cess as per direction of Engineer-In-charge. |
| 59 | 110mm dia rigid UPVC pipe Class-3 (0.60 mpa) |
| 60 | Const. of Circular soak pit of. size-1.20m dia x 2.00m depth including cost of all materials,conveyance to worksite,contractor profit & labour cess etc all complete and direction of Engineer-in-charge. |
| 61 | Const. of Brick masonry IC of internal Size-0.75x0.75x0.45m including cost of all materials,conveyance to worksite,contractor profit & labour cess etc all complete and direction of Engineer-in-charge. |
| 62 | Supplying All materials,labours T&P for complete internal electrification .( 1.5 &2.5 ,4,6 sqmm recessed wiring to light point, fan point, inverter wiring , exhaust fan point, call bell point having 250v modular switches with boxes,100 watt led flood light -4 nos ,earthing ,exhaust fan ,,fans, lights,ac point with 1.5 tonn 5star AC with stablizer,MCB etc all complete and direction of Engineer-in-charge. |
| 63 | Distribution Network (DI-K7),Fittings & Civil Works |
| 64 | Cutting asphalt or bituminous road of flexible pavments and disposal of dismantalled materials up a lead of 1000 mtr stacking servicable and unservicable materials separately including cost of all labour, T & P etc. all complete as per the direction of engineer-in-charge. |
| 65 | Cutting WBM/Metal road of flexible pavments and disposal of dismantalled materials up a lead of 1000 mtr stacking servicable and unservicable materials separately including cost of all labour, T & P etc. all complete as per the direction of engineer-in-charge. |
| 66 | Cutting concrete road of grannualar course of flexible pavments and disposal of dismantalled materials up a lead of 1000 mtr stacking servicable and unservicable materials separately including cost of all labour, T & P etc. all complete as per the direction of engineer-in-charge. |
| 67 | Removing & refixing of 80mm thick precast cement concrete interlocking paving block of all size over 50mm thick course sand bedding (duly compacted) including filling of joints with sand complete etc all complete and as per the specifications and directions of Engineer-in-charge. |
| 68 | Supplying all labour, T&P for earth work excavation in trenches in following kinds of soil within initial lead of 50m & initial lift of 1.50m including rough fressing breaking clods and laying in layers not exceeding 0.30m. In depth, levelling the bed, using pans, vessels for slushy soil and including sundries supervision charges &labour cess etc, as per direction of Engineer-in-charge |
| 69 | In all kinds of soil |
| 70 | Disintegrated rock not required blasting |
| 71 | Supplying & laying inside trenches Ductile Iron fittings & Specials of following sizes confirming to IS Specification etc all complete as per direction of Engineer-in-charge. |
| 72 | For 100mm to 450mm dia |
| 73 | Taking 5% of pipe weight |
| 74 | Providing push-on-joints conforming to IS:3114-1994 to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes using Rubber Gaskets Conforming to I.S 5382 of S.B.R quality including testing of joints as per specification complete . (Labour Only) |
| 75 | 100mm diameter |
| 76 | 150mm diameter |
| 77 | 200mm diameter |
| 78 | 250mm diameter |
| 79 | Laying of ISI Marked Centrifugally Cast (Spun) K - 7 Class Ductile Iron Socket & Spigot Pressure Pipes in standard length with internal cement mortar lining and external bituminous coating conforming to IS 8329:2000 and its subsequent amendments & ISI Marked SB/EPDM Rubber Gasket (IS:5382) for Push-on type Flexible Joints of DI Pipes,including inspection, transportation, handling, loading, unloading, stacking, etc. all complete as per specification and direction of Engineer-in-charge. |
| 80 | 100mm dia DI (K7) |
| 81 | 150mm dia DI (K7) |
| 82 | 200mm dia DI (K7) |
| 83 | 250mm dia DI (K7) |
| 84 | Supply fitting & Fixing cast iron DI Sluice Valve of RATING PN - 1.60(IS 14846/2000) with double flanged ends (with wheel) for water works purpose for the following rating & nominal diameters but (including cost of Sluice Valves) (Kirloskar/ VAG/Talis/AVK/Hawle/Audco/IVC or any other approved REPUTED MAKE) |
| 85 | 100mm dia |
| 86 | 150mm dia |
| 87 | 200mm dia |
| 88 | 250mm dia |
| 89 | Supplying all materials,labour and T&P and constructing brick masonry chamber as per P.H. specification and design all complete including Cover Slab (per each) |
| 90 | S.V. chamber internal size:-[0.75x0.75x1.225mtr] for 80mm dia to150mm dia S/V. |
| 91 | S.V. chamber internal size:--[0.75x0.75x1.485mtr] for 200mm. to 450mm .dia. S/V. |
| 92 | Supplying all labour and T&P for providing and laying MS pipe and specials confirming to IS 3589/99 of quality grade FE 410/ GI Pipe (Medium ) confirming to specification of following nominal dia and including transportation of pipes and fitting to site etc all complete as per the direction of E.I.C. |
| 93 | 100mm dia M.S.Pipe (4.50mm thick) |
| 94 | 100mm dia M.S. Flange.(10mm thick) |
| 95 | 100mm dia x 90' M.S. Bend/90' M.S. Bend/Offset Bend |
| 96 | 150mm dia M.S.Pipe (4.50mm thick) |
| 97 | 150mm dia M.S. Flange.(12mm thick) |
| 98 | 150mm dia x 45' M.S. Bend/90' M.S. Bend/Offset Bend |
| 99 | 200mm dia M.S.Pipe (6.30mm thick) |
| 100 | 200mm dia M.S. Flange.(12mm thick) |
| 101 | 200mm dia 45⁰ M.S Bend/90' M.S. Bend/Offset Bend |
| 102 | 250mm dia M.S.Pipe(6.30mm thick) |
| 103 | 250mm dia M.S. Flange. |
| 104 | 250mm dia 45⁰ M.S Bend/90' M.S. Bend/Offset Bend |
| 105 | Flame cutting and facing of MS plate or pipes upto 8mm thick including supply of all labor, material, tools & plants for all complete as per specification and direction of Engineer-in-Charge. |
| 106 | Supplying all labour and T&P for Welding with two welding beads/pass, conforming to IS:816-1998 (Fillet weld) to MS pipes and fittings at site. |
| 107 | Same as cutting |
| 108 | Filling in foundation and plinth with excavated materials including watering and ramming as directed by the Engineer-in-charge. |
| 109 | Filling in foundatin and plinth with sand watered and rammed including cost of sand & labour. |
| 110 | Supplying all materials, labour, T&P and providing cement concrete(1:3:6) with 12mm size crusher broken hard granite chips including all cost of conveyance, royalty, sundries, watering for curing, supervision charge, contractor profit & labour cess etc. all complete as p[er the direction of Engineer-in-charge. |
| 111 | Supplying all materials, labour, T&P and providing cement concrete(1:2:4) with 12mm size crusher broken hard granite chips including all cost of conveyance, royalty, sundries, watering for curing, supervision charge, contractor profit & labour cess etc. all complete as per the direction of Engineer-in-charge. |
| 112 | Providing Supplying, fitting and fixing of 80mm thick interlock concrete colour paver block on compacted river coarse sand free from all organic materials and filling the joints with sand. including cutting corbelling, splays where ever necessary to proper size with cost, conveyance, royalties and taxes of all materials and cost of all labour, etc. complete in all respect as directed by Engineer in charge. |
| 113 | Supplying all materials, labour, and T&P for removal/carriage of excavated earth from site to a distance 5 km away etc all complete and as per the specifications and directions of engineer-in-charge. |
| 114 | Road cutting+ sand filling |
| 115 | Supplying all materials Labour & T&P for Interconnection comlpeted as per specification and Engineering_In-Charge. |
| 116 | 100mm dia DI (K7) |
| 117 | 150mm dia DI (K7) |
| 118 | 200mm dia DI (K7) |
| 119 | 250mm dia DI (K7) |
| 120 | 300mm dia DI (K7) |
| 121 | PLC PANEL & AUTOMATION SYSTEM AT INTAKE WELL |
| 122 | PLC panel for Intake: Design, manufacture, supply, installation, testing and commissioning of indoor type PLC panel of size approx. 1000 mm X 700 mm X 1500mm (LBH), fabricated out of min. 2 mm thick CRCA sheet powder coated to Siemens gray color.The Panel shall be provided with reputed make PLC with following accessories as well as input output configuration.The PLC shall be programmed with IEC 61131 standards for control, monitoring and communication of equipments & instruments at Raw water Pumphouse.PLC shall have Ethernet port & protocal for Modbus TCP communication with following IO.DI –16 num DO – 16 num AI –8 num AO – 4 num.7inch color TFT HMI complete with programming shall be provided to interact with PLC. The panel shall include all the accessories (not limited to following) to achieve purpose of smooth & trouble free operation of pump house.MCB 10A DP – 1 num MCB 4A DP – 4 num ,24 VDC Power Supply 10A – 1 num, Push Buttons – 7 num Selector Switch - 2 num Control Contactor – 2 num, Annunciator with 6 Windows NO to NC Type,Electronic Hooter – 1 num Control Transformer – 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num,Panel Light with Door Switch – 1 num Control Indication Lamp – 5 num ,Wiring + TB etc – 1 lot Hardware – 1 lot and all Complete Works as per specification and directions of Engineer-in-Charge |
| 123 | Windows based PC with latest configuration & OS complete with necessory office & antivirus softwares.PC configuration shall not be less than Intel i5 10th Gen CPU, 16 GB Ram, 128 GB SSD, 500 GB HDD, DVD RW, Rs232 &Rs485 port, 2 RJ45 ports, Keyboard, Optical Mouse, 32 inch color TFT Monitor, Latest Windows Pro OS, Microsoft Office & Antivirus & Internet Sequrity software for 3 years license and completed as per Engineering-In-Charge. |
| 124 | Supply, Installation and commissioning of single phase 1KVA online UPS with pure sine wave & float cum boost charging with battery rack and maintenance free battery system for 3hour backup including cables power plug, switch etc. all Complete Works. |
| 125 | Supply, Installation of Control Desk -1 no., Table - 1 no. & Chairs - 2 nos. at SCADA room and completed as per Engineering-In-Charge. |
| 126 | Supply, Installation and commissioning of energy efficient inverter split AC-1.5 Ton 5 star and complete as per Engineer-In-Charge. |
| 127 | Supply, Installation, Testing, Intgeration & Commissioning of 43\\" LED monitor at Conf. Room for display of total water system (Online) complete as per specification and directions of Site Engineer /Engineer-in-Charge. |
| 128 | Designing, Supplying, Installing, commissioning & testing of Ultrasonic raddar type level transmitter CE marked with following technical parameters Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART.Power supply - 24V DC ext.Display - 4\\" LEDRange- 0-30mtr.Accuracy - +/- 0.25% of FullScale or betterEnclosure- IP 68Mounting - On PLC panel all complete work as per direction of Engineer-in-charge. |
| 129 | Supplying,Installation & testing of 4G Dual Sim LTE Router with 1 X LAN, 1 X WAN, RS485 on board with one at a time usage, WI-FI (802.11 b / g / n), 1 X Cellular Antenna, 1 X WIFI Antenna, Model- SW245 (RS485) and complete work as per direction of Engineer-in-charge |
| 130 | Providing, installation, testing and commissioning of Glycerine filled Pressure Gauge dial size 150mm Bourden's type as IS3624:1987 MOUNTING DIRECT BOTTOM SS Body toughned glass window all complete work as per direction of Engineer-in-charge |
| 131 | Pressure Transmitter for raw water pumping station:Designing, Supplying, Installing, commissioning & testing of pressure transmitter CE markd with following technical parameters at Raw Water Pump House and Interfacing with PLC panel including mounting arrangement along with snubber and needle valve 1MM^2 2core braided screw cable wire,screw grip and clamp for DI/MS fiiting. Output 4-20 mA / HARTPower supply - 24V DC ext.Display - 4\\" LEDAccuracy - +/- 0.1 % of full scaleor betterEnclosure- IP 68 and complete work as per direction of Engineer-in-charge |
| 132 | Designing, Supplying, Installing, commissioning & testing with Terminating & Interfacing of 2 C x 1.5 sq.mm as per IS 694 twisted shielded copper armoured conductor on wall in GI tray or in ground suitable for supplied DC Voltage and all Complete Works as per specification and directions of Engineer-in-Charge |
| 133 | Supplying and erecting armoured control cable with ISI mark stranded / solid copper conductor 1.1 kV grade complete erected on wall / panel or in provided trench in an approved manner. 4c X 2.5 sq mm Copper conductor PVC insulated, armoured control cable and all Complete Works as per specification and directions of Engineer-in-Charge |
| 134 | Designing, Supplying, Installing, commissioning & testing with Terminating & Interfacing of 2 pair x 1.0 sq.mm. as per IS 694 copper shieled, twisted, multistraned armoured cable on wall in GI tray or on ground and all Complete Works as per specification and directions of Engineer-in-Charge. |
| 135 | Supply, Installation and commissioning of Control cables to be inserted in conduit pipe in trenches, cables to be laid in racks, cleated on walls, cable lugs, cables glands, conduits, cablejoints Screened cable unarmoured etc all Complete Works as per specification and directions of Engineer-in-Charge. CAT 6 Dlink Cable |
| 136 | Supply & installation commissioning of full-bore type electromagnetic water flow meter as per ISO 4064 for raw water at various locations for monitoring volume of water flow, with following technical specification: including sensor, transmitter, surge arrestor, cable GI duct if suitable size for 25 meter with built-in GSM/GPRS (with SIM card and its charges valid for 36 months) including pipe cutting, levelling and installation of flow meter in the pipeline with necessary tools, tackles, crane, including 36 months guarantee etc. all complete as may be required at site and based on technical specification and all complete as per direction of Engineer-in-Charge. |
| 137 | 250mm dia |
| 138 | Providing, erecting Electric Valve Actuator of PN 1-6 rating, totally enclosed, weather proof & dust proof construction with IP-67 protection class, suitable for installation in any position without lubrication, leakage or other lubrication, leakage or other operational difficulty, with special grease-filled gear box and hand wheel for emergency manual operation which will automatically disengage on restoration of power to motor and with 10 Watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction motor working on 440 Volt ±10%, 3 Phase, 50 Hz AC of intermittent duty rating S-2, insulation class \\"F\\" and temperature rise restricted to class \\"B\\" with IP-67 protection class suitable for DOL starting and with three thermostats and 30% overload margin.The torque rating of reduction gearbox shall be at least 1.5 times the maximum torque required for opening and closing of valve with integral starter for ON & OFF operation and all completed as per specification and direction of Engineer-in-Charge. |
| 139 | 200mm dia |
| 140 | Earthing:Providing electrical system's earthing as per latest IS 3043, and the work shall include the following:Earthing system comprising of copper earth plate (600 × 600 × 3.15 mm thick), G.I. strip (25 × 5 mm), G.I. pipe of 40 mm, 2.7 metre long with mesh covered funnel.Digging 900 mm dia earthing pit to suitable depth for burying the main electrode in the pit. The pit shall be filled with alternate layers of salt and charcoal/coke, 150 mm thick around the pipe to the entire depth.An inspection chamber of 300 × 300 × 300 mm size shall be constructed with Fly Ash Brick in CM (1:6) in foundation and plinth. The chamber shall be provided with CI/MS cover hinged to the frame, etc., all complete as per the direction of the Engineer-in-Charge. |
| 141 | Instrumentation of Proposed WTP(4.3 mld) |
| 142 | Supply and Laying of 40MM dia HDPE pipe in cable trench or buried as per specification and directions of Engineer-in-Charge. |
| 143 | Supply, Installation and commissioning of Control cables to be inserted in conduit pipe in trenches, cables to be laid in racks, cleated on walls, cable lugs, cables glands, conduits, cablejoints etc. as per specification. all Complete Works Screened cable unarmoured and completed as per specification and directions of Engineer-in-Charge. |
| 144 | Supply, Installation and commissioning of CAT-6 Dlink cable and completed as per specification and directions of Engineer-in-Charge. |
| 145 | Supply & installation of Open channel flow meter (1 no.) to be installed at WTP open channel for monitoring water flow to clarifier with following technical specifications:- Level, ultrasonic, contactless Application: liquids, solids.Sensor: PVDF Protection class IP68 NEMA6P Self cleaning effect of sensor membrane and completed as per specification and directions of Engineer-in-Charge. of Reputed make with ISI standard like Forbes Marshall/ Techtrol/Siemens/ABB |
| 146 | Supply & installation of LOH ( Loss of Head) indicator with display unit - 4 sets at filter house for auto wash of filter bed with following technical specifications:-Housing : Cast Aluminium, Powder Coated. Mounting: Wall Mounting Power Supply : 230 V AC, 50 Hz Power Consumption : 4 VA (approximately) Adjustment Range : Span : Min 10%cof Electrode Length Alarm : A relay C/O rated 6 Amps 230 V, non-inductiveload adjustable throughout range Current output : 4-20mA DC non isolated, max. load resistance 600 Ohms, corresponding to differential level Accuracy : ±4% of Electrode Length Option : 1. Local as well as Control Room Display. 2. Loss of Head (LoH) can be supplied with Rate of Flow (RoF) in a common CA Housing with IP-55Protection and completed as per specification and directions of Engineer-in-Charge. of Reputed make like Siemens/Sapcon. |
| 147 | PLC panel for 2 nos of Filter bed: Design, manufacture, supply, installation, testing and commissioning of indoor type PLC panel of size approx. 1200 mm X 700 mm X 1500mm (LBH), fabricated out of min. 2 mm thick CRCA sheet powder coated to Siemens gray color.The Panel shall be provided with reputed make PLC with following accessories as well as input output configuration.The PLC shall be programmed with IEC 61131 standards for control, monitoring and communication of equipments & instruments at WTP plant (sand filter bed washing and operation ).PLC shall have Ethernet port & protocal for Modbus TCP communication with following IO.DI –40 num DO – 40 num AI –16 num AO – 12 num.10 inch color TFT HMI complete with programming shall be provided to interact with PLC. The panel shall include all the accessories (not limited to following) to achieve purpose of smooth & trouble free operation of sand filter.MCB 10A DP – 1 num MCB 4A DP – 4 num ,24 VDC Power Supply 10A – 1 num, Push Buttons – 30 num Selector Switch - 15 num Control Contactor – 15 num, Annunciator with 12 Windows NO to NC Type,Electronic Hooter – 1 num Control Transformer – 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num,Panel Light with Door Switch – 1 num Control Indication Lamp – 15 num ,Wiring + TB etc – 1 lot Hardware – 1 lot 2 HP VFDS- 3 num and all Complete Works as per specification and directions of Engineer-in-Charge |
| 148 | Windows based PC with latest configuration & OS complete with necessory office & antivirus softwares.PC configuration shall not be less than Intel i5 10th Gen CPU, 16 GB Ram, 128 GB SDD, 500 GB HDD, DVD RW, Rs232 &Rs485 port, 2 RJ45 ports, Keyboard, Optical Mouse, 32 inch color TFT Monitor, Latest Windows Pro OS, Microsoft Office & Antivirus & Internet Sequrity software for 3 years license and completed as per Ingineering-In-Charge. |
| 149 | Supply, Installation and commissioning of single phase 1KVA online UPS with pure sine wave & float cum boost charging with battery rack and maintenance free battery system including cables power plug, switch having application in 24V lot DC Battery (drytype) charging to output continuous 3 hrs power backup all Complete Works. |
| 150 | Supply & installation of Pressure Transmitter :Designing, Supplying, Installing, commissioning & testing of pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel including mounting arrangement along with snubber and needle valve, 1.0 sq.mm 2 core copper braided screen cable Wire, screw, grip & clamp for DI / MS pipe fitting.Output 4-20 mA / HARTPower supply - 24V DC ext.Display - 4\\" LEDAccuracy - +/- 0.1 % of full scaleor betterEnclosure- IP 68 and completed as per specification and directions of Engineer-in-Charge. |
| 151 | Providing, installation, testing and commissioning of Glycerine filled Pressure Gauges Bourden's type as IS3624:1987 Dial size 150 mm MOUNTING DIRECT BOTTOM SS Body toughned glass window all complete work as per direction of Engineer-in-charge |
| 152 | Design, Supply, Installation, Testing of pH analyser as per IUPAC( International Union for Pure & Applied Chemistry)at A.F. and Interfacing with PLC panel including mounting arrangement.Range : 0 ‐14 ,pH Accuracy : Better than 0.5% of full scale ,Supply Voltage : 24V dc, Output : 4‐20 mA /HART As per IEC 61000-6-2 & IEC 61000-6-3. ( Inlet )as per direction of Engineer-in-charge |
| 153 | Design, Supply, Installation, commissioning, testing of Turbidity Anayser as per ISO 7027 scattering light method at A.F. and Interfacing with PLC panel. Turbidity analyser shall comprises of 3 components i.e. sensors,signal distributor and transmitter with indicator. with 2 Outputs, 1 to PLC & anather to Local Display with mounting arrangement. ( Inlet ).Overall Range : 0 ‐ 2000 NTU ,Accuracy : +/‐ 0.02 NTU ,Supply Voltage : 230 V ac, Output : 4‐20 mA /HART.as per direction of Engineer-in-charge |
| 154 | Designing, Supplying, Installing, commissioning & testing of Ultrasonic level transmitter CE marked with following technical parameters Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART.Power supply - 24V DC ext.Display - 4\\" LEDRange- 0-10 mtr - 20 mtr.Accuracy - +/- 0.25% of FullScale or betterEnclosure- IP 68Mounting - On PLC panel all Complete Works as per specification and directions of Engineer-in-Charge |
| 155 | Supply, Installation and commissioning of soft Starter with six wire bypas arrangement up to 300HP and completed as per specification and directions ofEngineer-in-Charge. |
| 156 | Supply, installation, testing and commissioning of emergency Chlorine Leak Absorption System having capacity to neutralise Chlorine gas of 900 kg at a time consisting of caustic storage tank (MSRL) with foundation for tank, motor and blower, FRP lined centrifugal blower for neutralization system 2200 m³/hr (1W + 1S), HOS absorption tower (1.0 m × 2.50 m), caustic circulation pump 20.0 m³/hr, head 15 m (1W + 1S), agitator with SS shaft for caustic tank, magnetic float type level switch for caustic tank, PP/GFRP suction and delivery pipe and valve arrangement from tonner room to absorption tower and tower vent line, pressure indicator for leak absorption system with cost of 1.50 MT caustic soda (1:50 MT for solution), FRP half hood for 3 nos. tonners, continuous ventilating fans 2 nos. of capacity 1710 m³/hr and emergency exhaust fans 2 nos. of capacity 6120 m³/hr, MCC panel and PLC with power supply cable, cable tray, control unit fully automatic during leak including 2 nos. traditional earthing, etc., for neutralization system, chlorine leak detector (hooter) with standby GSM pulse module with 2 nos. sensors, safety shower for eye and full body including all valves, strainers and all other materials required for commissioning of the leak absorption system, etc., with suitable gas filter with all CS piping and valve arrangements including pressure gauge for chlorine gas, 6\\" temperature gauges, etc., complete for smooth operation of 2 nos. gas chlorination systems separately for different outlets as per specification and direction of the Engineer-in-Charge, complete at Atabira WTP. |
| 157 | Providing, erecting Electric Valve Actuator of PN 1.6 rating, totally enclosed, weather-proof and dust-proof construction with IP-67 protection class, suitable for installation in any position without lubrication, leakage or other operational difficulty, with special grease-filled gearbox and hand wheel for emergency manual operation, which will automatically disengage on restoration of power to the motor, and with 10 Watt single-phase space heater, continuous local mechanical position indicator and individually replaceable counter gear assembly, and with two torque and four limit switches with S.S. flap, operated with gear-driven cams and of rating 250 V, 5 Amp, AC/DC, torque switch dial and TEFC squirrel cage induction motor working on 440 Volts ±10%, 3 Phase, 50 Hz AC, intermittent duty rating S-2, insulation Class \\"F\\", and temperature rise restricted to Class \\"B\\", with IP-67 protection class, suitable for DOL starting, with three thermostat and 30% overload margin.The torque required for opening and closing of valve with integral starter for ON & OFF operation,and all complete as per specification and direction of the Engineer-in-Charge |
| 158 | 100 mm |
| 159 | 150 mm |
| 160 | 200 mm |
| 161 | 250 mm |
| 162 | providing Actuator oparated Gates (300X300) for inlet and bypass location as per specification and directions of Engineer-in-Charge |
| 163 | Designing, Supplying, Installing, commissioning & testing with Terminating & Interfacing of 2 C x 1.5 sq.mm as per IS 694 twisted shielded copper armoured conductor on wall in GI tray or in ground suitable for supplied DC Voltage and all Complete Works as per specification and directions of Engineer-in-Charge |
| 164 | Supplying and erecting armoured control cable with ISI mark stranded / solid copper conductor 1.1 kV grade complete erected on wall / panel or in provided trench in an approved manner. 4c X 2.5 sq mm Copper conductor PVC insulated, armoured control cable and all Complete Works as per specification and directions of Engineer-in-Charge |
| 165 | Designing, Supplying, Installing, commissioning & testing with Terminating & Interfacing of 2 pair x 1.0 sq.mm. as per IS 694 copper shieled, twisted, multistraned armoured cable on wall in GI tray or on ground and all Complete Works as per specification and directions of Engineer-in-Charge |
| 166 | Earthing:Providing electrical system's earthing as per latest IS 3043, and the work shall include the following:Earthing system comprising of copper earth plate (600 × 600 × 3.15 mm thick), G.I. strip (25 × 5 mm), G.I. pipe of 40 mm, 2.7 metre long with mesh covered funnel.Digging 900 mm dia earthing pit to suitable depth for burying the main electrode in the pit. The pit shall be filled with alternate layers of salt and charcoal/coke, 150 mm thick around the pipe to the entire depth.An inspection chamber of 300 × 300 × 300 mm size shall be constructed with Fly Ash Brick in CM (1:6) in foundation and plinth. The chamber shall be provided with CI/MS cover hinged to the frame, etc., all complete as per the direction of the Engineer-in-Charge. |
| 167 | SCADA FOR CLEAR WATER PUMP, |
| 168 | PLC panel for CWP: Design, manufacture, supply, installation, testing and commissioning of indoor type PLC panel of size approx. 1000 mm X 700 mm X 1500mm (LBH), fabricated out of min. 2 mm thick CRCA sheet powder coated to Siemens gray color.The Panel shall be provided with reputed make PLC with following accessories as well as input output configuration.The PLC shall be programmed with IEC 61131 standards for control, monitoring and communication of equipments & instruments at PLC shall have Ethernet port & protocal for Modbus TCP communication with following IO.DI –16 num DO – 16 num AI –8 num AO – 4 num.7 inch color TFT HMI complete with programming shall be provided to interact with PLC. The panel shall include all the accessories (not limited to following) to achieve purpose of smooth & trouble free operation of pump house.MCB 10A DP – 1 num MCB 4A DP – 4 num ,24 VDC Power Supply 10A – 1 num, Push Buttons – 7 num Selector Switch - 2 num Control Contactor – 2 num, Annunciator with 6 Windows NO to NC Type,Electronic Hooter – 1 num Control Transformer – 1 num Emergency PB – 1 num Panel Cooling Fan – 1 num,Panel Light with Door Switch – 1 num Control Indication Lamp – 5 num ,Wiring + TB etc – 1 lot Hardware – 1 lot and all Complete Works as per specification and directions of Engineer-in-Charge |
| 169 | Windows based PC with latest configuration & OS complete with necessory office & antivirus softwares.PC configuration shall not be less than Intel i5 10th Gen CPU, 16 GB Ram, 128 GB SDD, 500 GB HDD, DVD RW, Rs232 &Rs485 port, 2 RJ45 ports, Keyboard, Optical Mouse, 32 inch color TFT Monitor, Latest Windows Pro OS, Microsoft Office & Antivirus & Internet Sequrity software for 3 years license and completed as per Engineering-In-Charge. |
| 170 | Supply, Installation and commissioning of single phase 1KVA online UPS with pure sine wave & float cum boost charging with battery rack and maintenance free battery system for 1hour backup including cables power plug, switch etc. all Complete Works as per Engineering-In-Charge. |
| 171 | Supply & installation commissioning of full-bore type electromagnetic water flow meter as per ISO 4064 for raw water at various locations for monitoring volume of water flow, with following technical specification: including sensor, transmitter, surge arrestor, cable GI duct, suitable size for 25 meter with built-in GSM/GPRS (with SIM card and its charges valid for 36 months) including pipe cutting, levelling and installation of flow meter in the pipeline with necessary tools, tackles, crane, including 36 months guarantee etc. all complete as may be required at site and based on technical specification and all complete as per direction of the Engineer-in-Charge. |
| 172 | 300mm dia Full bore type Electro Magnetic Water Flow meter |
| 173 | Pressure Transmitter :Designing, Supplying, Installing, commissioning & testing of pressure transmitter CE markd with following technical parameters at CWP and Interfacing with PLC panel including mounting arrangement along with snubber and needle valve, 1.0 sq.mm 2 core copper braided screen cable Wire, screw, grip & clamp for DI / MS pipe fitting.Output 4-20 mA / HARTPower supply - 24V DC ext.Display - 4\\" LEDAccuracy - +/- 0.1 % of full scaleor betterEnclosure- IP 68 |
| 174 | Providing, installation, testing and commissioning of Glycerine filled Pressure Gauges Bourden's type as IS3624:1987 Dial size 150 mm MOUNTING DIRECT BOTTOM SS Body toughned glass window all complete work as per direction of Engineer-in-charge |
| 175 | Providing, erecting Electric Valve Actuator of PN 1.6 rating, totally enclosed, weather proof & dust proof construction with IP-67 protection class, suitable for installation in any position without lubrication, leakage or other operational difficulty, with special grease-filled gear box and hand wheel for emergency manual operation which will automatically disengage on restoration of power to motor and with 10 Watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction motor working on 440 Volt ±10%, 3 Phase, 50 Hz AC of intermittent duty rating S-2, insulation class \\"F\\" and temperature rise restricted to class \\"B\\" with IP-67 protection class suitable for DOL starting and with three thermostats and 30% overload margin.The torque rating of reduction gearbox shall be at least 1.5 times the maximum torque required for opening and closing of valve with integral starter for ON & OFF operation and all completed as per specification and direction of the Engineer-in-Charge. |
| 176 | 200mm Dia |
| 177 | Supply, Installation and commissioning of Control cables to be inserted in conduit pipe in trenches, cables to be laid in racks, cleated on walls, cable lugs, cables glands, conduits, cablejoints etc. as per specification. all Complete Works Screened cable unarmoured. |
| 178 | 1.5 sqmm 4 C CU AR Shielded Cable |
| 179 | 1.5 sqmm 2 CU AR Shielded Cable |
| 180 | Instrument Cable- 2 Pair 1.5 mm2 cable |
| 181 | Supply of Level Transmitter to be installed at wash water tank & CWR (Clear Water Reservoir) with following specification:Range= 0 to 8 mtr, Type =Ultrasonic / Radar, Power Supply- Loop Powered 24V DC, Out Put=4-20mA( Make- Vega, Techtrol, Forbes Marshall, ABB or Any other approved reputed make) |
| 182 | Earthing:Providing electrical system's earthing as per latest IS 3043, and the work shall include the following:Earthing system comprising of copper earth plate (600 × 600 × 3.15 mm thick), G.I. strip (25 × 5 mm), G.I. pipe of 40 mm, 2.7 metre long with mesh covered funnel.Digging 900 mm dia earthing pit to suitable depth for burying the main electrode in the pit. The pit shall be filled with alternate layers of salt and charcoal/coke, 150 mm thick around the pipe to the entire depth.An inspection chamber of 300 × 300 × 300 mm size shall be constructed with Fly Ash Brick in CM (1:6) in foundation and plinth. The chamber shall be provided with CI/MS cover hinged to the frame, etc., all complete as per the direction of the Engineer-in-Charge. |
| 183 | INSTRUMENTATION WORK AT DISTRUBUTION SITE |
| 184 | Supply and installation of MS pipe including required numbers of bends and flanges and dismentaling joint etc required for installation of DMA control units (i.e- Globe valve, flow meter, PG, PT etc.) and fiber cover over the arrangement fixing on CC(1:3:6) platform including cost of all materials, labour for fitting and fixing etc. all complete.as per site requirement and as per the direction of the engineer in charge.( excluding cost of Sluice valve, flow meter, PG, PT.) |
| 185 | 150 mm(Zone -03) |
| 186 | 200 mm (Zone -1&2) |
| 187 | Distribution Line(Sub DMA) |
| 188 | 200 mm(Zone -1&3) |
| 189 | 250 mm(Zone -1, Zone -2(2nos) and Zone -3) |
| 190 | Supply with fitting and fixing of of D.I. Mechanical Dismantling Joints for use to main uninterrupted water supply in the pipeline in case of repair of Flow meter as per specification and direction of Enginer - in - charge |
| 191 | 200 mm(Zone -1&3) |
| 192 | 250 mm(Zone -1, Zone -2(2nos) and Zone -3) |
| 193 | CONTROL ROOM PLC for ESR OPERATION: Supply all material, labour T&P for installation & testing commissioning of PLC System of appropriate capacity & sufficient provision of digital & analog input and output to run the plant & machineries within the campus limit, with minimum 20% spare cards, being operated locally at ESR campus, with provision of PLC operation (On & Off) of feed pump with respective Chlorine analyzer with an architecture of maintaining water quality in distribution pipeline at identified location. Complete operation of the feed pump depends upon the water quality communicated via point to point(P2P) signal from the remote analyzer unit to main PLC. Provision should be there for LIVE data communication (by agency) between the PLC panels through FO Cable for the operation (on & off) of clear water Well Pumps as per the water requirement at MBR/ESR/OGR/CWR. Local data storing facility should be there and for monitoring and analysis as per the user needs and report generation. (The Cost is inclusive of cost of materials, installation & successful commissioning etc) The PLC & all necessaries shall be of high standard make. (Make -Schneider/Siemens/Rockwell or any other approved make) |
| 194 | Supply, Installation & Commissioning of SCADA software and cost for development of 24x7 distribution management system software. Design, manufacture, supply, installation, testing and commissioning of SCADA System for MBR/GSR/ESR Management system windows based PC with latest configuration & OS complete with necessary office & antivirus softwares. PC configuration shall not be less than Intel i5 10th Gen CPU, 16 GB Ram, 128 GB SSD, 500GB HDD, DVD RW, Rs232 & Rs485 port, 2 RJ45 ports, USB based Keyboard, Optical Mouse, 43 inch color LED Monitor, Latest Windows Pro OS, Microsoft Office & Antivirus & Internet Security software for 3 years license, 1 KVA online UPS with 30 min battery Back up 1 No., A4 Size Laser Printer 1 No., Wooden Computer Table 1 No., Chair 2 Nos., Preparation of P & I Diagram. One LTE Cellular Gateway with minimum following specifications shall be provided with Dual Sim Operators, with atleast one, Ethernet, one USB & one serial port for connectivity with host device, ruegged construction for hazardous location. One remote dice management software shall be provided to manage IP addresses of RTUs. SCADA Software of reputed company with developer & run time license with unlimited number of Tags with following features & functions: 1. Supervise real-time data in the form of graphical presentation 2. Control MBR/GSR/ESR processes locally or through Remote locations 3. Dynamic process Graphic, It should resemble the process mimic. SCADA should have good library of symbols so that develop the mimic as per required. When operator sees the screen he should know what's going in plant. 4. Alarm summary & Alarm history, SCADA system must be able to detect, display, and log alarms and events. When there are problems the SCADA system must notify the operators to take corrective action. 5. Acquire real-time data as well as logs data with Real time trend & Historical time trend. 6. Web Connectivity. Real-time displays can be accessed on remotely attached PCs and notebooks using internet. SCADA Programming shall be done so as operator can visualize and control complete pump house operation from operator desk. All important alarms & events shall be logged. All the data from field instruments & equipments shall be logged. There shall be provision to take reports in required formats of real time & historical data, events & alarms. There shall be provision of broadcasting messages, emails of reporting information. There shall be provision of access security all complete as per the direction of Engineer in Charge. |
| 195 | Supply, Installation and commissioning of Control cables to be inserted in conduit pipe in trenches, cables to be laid in racks, cleated on walls, cable lugs, cables glands, conduits, cablejoints etc. as per specification. all Complete Works Screened cable unarmoured. |
| 196 | 1.5 sqmm 4 C CU AR Shielded Cable |
| 197 | 1.5 sqmm 2 CU AR Shielded Cable |
| 198 | Instrument Cable- 2 Pair 1.5 mm2 cable |
| 199 | Electromagnetic Flow Meter (EMF): Supply, installation, testing and commissioning of Electromagnetic Flow Meter (EMF) as per ISO 4064 for measurement of pure water with an accuracy of ±0.5% of measured value and protection as per the given specifications for sizes 100 mm to 1000 mm, including sensor, transmitter, surge arrester, cable, G.I. duct (if required), suitable built-in GSM/GPRS- (with sim card and its charges valid for 36 months) including the pipe cutting,leveling and installation of flow meter in the pipe lines with necessary tools, tackles, cranes including 36 months guarantee ETC complete.as may be required at site and based on technical specification as per direction of Engineer- In - Charge. |
| 200 | Distribution Line(Sub DMA) |
| 201 | 200mm (Zone-1&3) |
| 202 | 250mm (Zone-1,Zone-2(2nos)and Zone-3) |
| 203 | Providing, erecting Electric Valve Actuator of PN 1-6 rating, totally enclosed, weather proof & dust proof construction with IP-67 protection glass, suitable for installation in any position without lubrication, leakage or other operational difficulty, with special grease-filled gear box and hand wheel for emergency manual operation which will automatically disengage on restoration of power to motor and with 10 Watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction motor working on 440 Volt ±10%, 3 Phase, 50 Hz AC of intermittent duty rating S-2, insulation class \\"F\\" and temperature rise restricted to class \\"B\\" with IP-67 protection class suitable for DOL starting and with three thermostats and 30% overload margin.The torque rating of reduction gearbox shall be at least 1.5 times the maximum torque required for opening and closing of valve with integral starter for ON & OFF operation and all completed as per specification and direction of the /Engineer-in-Charge |
| 204 | Loading Line |
| 205 | 150mm (Zone-03) |
| 206 | 200mm (Zone-1&2) |
| 207 | Supplying, Fitting,fixing & Commissioning,of double chamber DI control valve of PN 1.6 ,hydraulic operated 24 V DC, selonoid control,IP68, shall be integrated with RTU pannel for operation (local/remote and web enabled with command and control) of make CLA/DOROT-300/Bermad-700 to control water supply including the cost of valve cutting the pipeline & making good to the damages including cost of all labours, T&P etc. all complete as per the direction of Engineer-in-charge.Electric Operated Selonoid Valve Pilot Actuated. |
| 208 | Distribution Line(Sub DMA) |
| 209 | 200mm (Zone-1&3) |
| 210 | 250mm (Zone-1,Zone-2(2nos)and Zone-3) |
| 211 | Providing, installation, testing and commissioning of Glycerine filled Pressure Gauges Bourden's type as IS3624:1987 Dial size 150 mm MOUNTING DIRECT BOTTOM SS Body toughned glass window all complete work as per direction of Engineer-in-charge |
| 212 | 200mm (Zone-1&3)-2 nos,250mm (Zone-1,Zone-2(2nos)and Zone-3)-4 nos |
| 213 | Pressure Transmitter :Designing, Supplying, Installing, commissioning & testing of pressure transmitter CE markd with following technical parameters at Raw Water Pump House and Interfacing with PLC panel including mounting arrangement along with snubber and needle valve, 1.0 sq.mm 2 core copper braided screen cable Wire, screw, grip & clamp for DI / MS pipe fitting.Output 4-20 mA / HARTPower supply - 24V DC ext.Display - 4\\" LEDAccuracy - +/- 0.1 % of full scale or betterEnclosure- IP 68 and all complete as per specification and direction of Engineer-in-charge |
| 214 | 200mm (Zone-1&3)-4 nos,250mm (Zone-1,Zone-2(2nos)and Zone-3)-8 nos |
| 215 | Supplying all materials Labour & T&P for Fixing of DI tamper proof Kinatic Air Valve P.N 1.0 for water works purposes conforming to IS specification for the following nominal diameters as per specification complete including cost of Air valve and isolation valve. Distribution line SUB DMA |
| 216 | 200mm (Zone-1&3)-2 nos,250mm (Zone-1,Zone-2(2nos)and Zone-3)-4 nos |
| 217 | Supply, installation of online chlorine,Turbidity & PH analyser with following technical specification a)Chlorine sensor range 0-10ppm c)5 Micron Cartridge filter except for turbidity d) 4G Modem with GSM/Ethernet/Fibre Output e)FRP/Stainless paneel f)Flow cell for chlorine & Turbidity Sensor g)Turbidity sensor range 0-100NTU with RS 485 Modbus output h)PH sensor range 0-14 i)Controller 4 channel (All Sub DMA -6nos)of reputed make as per the direction of Engineer-in-charge |
| 218 | Designing, Supplying, Installing, commissioning & testing of Ultrasonic level transmitter CE marked with following technical parameters Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext.,Display - 4\\" LED ,Range- 0-10 mtr - 20 mtr.,Accuracy - +/- 0.25% of Full Scale or better ,Enclosure- IP 68 ,Mounting - On PLC panel at ESR/UGR and all complete as per the direction of Engineer-in-charge |
| 219 | Communication and data transmission |
| 220 | HDPE PIPE: Supply and Laying of 40MM dia HDPE pipe in cable trench or buried as per specification and directions of Engineer-in-Charge. |
| 221 | OFC: Supply and Laying of 12core unarmoured Optical fibre cable (OFC :fiber glass with F-G 62.5/125micron, 2.6DB/KM F600) to various sites through HDPE pipe, prelaying testing of each cable drum for each fibre and taking the OTDR traces, submission of OTDR traces (in hard as well as soft copy) to Engineer-in-charge, blowing of OFC through previously laid HDPE, jointing / splicing of OFC, post installation testing of OFC for each fibre for each drum laid & taking OTDR traces, submission of OTDR traces (in hard as well as soft copy) to Engineer-in-chargeas per the scope, specifications and directions of Engineer-in-charge. |
| 222 | 4G Dual Sim LTE Router with 1 X LAN, 1 X WAN, RS485 on board with one at a time usage, WI-FI (802.11 b / g / n), 1 X Cellular Antenna, 1 X WIFI Antenna, Model- SW245 (RS485) Make- SWTPL |
| 223 | Supply and Installation of OFC jointing kits including LIU as per drawings, specifications and directions of Engineer-in-charge |
| 224 | Supply and laying of pre-cast RCC Joint Box 600mm dia, depth 600 with Iid as per specification and directions of Engineer-in Charge. |
| 225 | Earthing: :Providing electrical system's earthing as per latest IS 3043, and the work shall include the following:Earthing system comprising of copper earth plate (600 × 600 × 3.15 mm thick), G.I. strip (25 × 5 mm), G.I. pipe of 40 mm, 2.7 metre long with mesh covered funnel.Digging 900 mm dia earthing pit to suitable depth for burying the main electrode in the pit. The pit shall be filled with alternate layers of salt and charcoal/coke, 150 mm thick around the pipe to the entire depth.An inspection chamber of 300 × 300 × 300 mm size shall be constructed with Fly Ash Brick in CM (1:6) in foundation and plinth. The chamber shall be provided with CI/MS cover hinged to the frame, etc., all complete as per the direction of the Engineer-in-Charge. |
| 226 | MCC ROOM |
| 227 | CONTROL ROOM PLC for MCC Room: Design, manufacture, supply, installation, testing and commissioning of indoor type PLC panel of size approx. 1200 mm X 700 mm X 1500mm (LBH), fabricated out of min. 2 mm thick CRCA sheet powder coated to Siemens Gray color. The Panel shall be provided with reputed make PLC with following accessories as well as input output configuration. The PLC shall be programmed with IEC 61131 standards for control, monitoring and communication of equipments & instruments at MCC Room. PLC shall have Ethernet port & protocol for Modbus TCP communication with following IO DI – 72 num. DO – 40 num, AI – 12 num AO – 4 num, 10 inch color TFT HMI complete with programming shall be provided to interact with PLC The panel shall include all the accessories (not limited to following) to achieve purpose of smooth & trouble free operation of MCC Room. MCB 16A DP – 3 num, MCB 10A DP – 1 num, MCB 4A DP – 4 num, 24 VDC Power Supply 10A – 1 num, Push Buttons – 30 num, Selector Switch – 16 num, Control Contactor – 16 num, Annunciator with 12 Windows NO to NC Type Electronic Hooter – 1 num, Control Transformer – 1 num, Emergency PB – 1 num, Panel Cooling Fan – 1 num, Panel Light with Door Switch – 1 num Control Indication Lamp – 16 num, Wiring + TB etc – 1 lot Hardware The PLC & all necessaries shall be of high standard make. All complete as per specification and directions of Engineer-in-Charge. |
| 228 | Supply, Installation and commissioning of single phase 1KVA online UPS with pure sine wave & float cum boost charging with battery rack and maintenance free battery system including cables power plug, switch having application in 24V lot DC Battery (drytype) charging to output continuous 3 hrs power backup all Complete Works. |
| 229 | Design, manufacture, supply, installation, testing and commissioning of SCADA System for MCC Room. Windows based PC with latest configuration & OS complete with necessary office & antivirus softwares. PC configuration shall not be less than intel i5 10th Gen CPU, 16 GB Ram, 128 GB SDD, 500 GB HDD, DVD RW, Rs232 & Rs 485 port, 2 RJ45 ports, USB based Keyboard, Optical Mouse, 32 inch LED Monitor, Latest Windows Pro OS, Microsoft Office & Antivirus & Internet Sequrity software for 3 years license. SCADA Software of reputed company with developer & runtime license with minimum 512 number of Tags with following features & functions. 1. Supervise real-time data in the form of graphical presentation. 2. Control WTP, Intake and Distribution System processes locally or through Remote locations. 3. Dynamic process Graphic, It should resemble the process mimic. SCADA should have good library of symbols so that develop the mimic as per required. When operator sees the screen he should know what's going in plant. 4. Alarm summery & Alarm history, SCADA system must be able to detect, display, and log alarms and events. When there are problems the SCADA system must notify the operators to take corrective action. 5. Acquire real-time data as well as logs data with Real time trend & Historical time trend. 6. Web Connectivity, Real-time displays can be accessed on remotely attached PCs and notebooks using internet. SCADA Programming shall be done so as operator can visualize and control complete Water Supply operation from operator desk. All important alarms & events shall be logged. All the data from field instruments & equipments shall be logged. There shall be provision to take reports in required formats of real time & historical data, events & alarms. There shall be provision of broadcasting messages, emails of reporting information. There shall be provision of access sequrity. An Industrial grade Din rail mounting Ethernet switch with 5 ports shall be provided. An Industrial grade modem with4G/5G GSM connectivity shall be provided. All complete as per specification and directions of Site Engineer /Engineer-in-Charge. |
| 230 | Supply, Installation and commissioning of LT surge arrester having 5KA capacity with Spike and all accessories including cost of all materials, labour, T & P etc all complete. |
| 231 | Supplyof1TBSSD(Solid State Device)for RAM and complete as per specification and directions of Engineer-in-Charge |
| 232 | Supply Installation of Laserjet Colour Printer and complete as per specification and directions of Engineer-in-Charge.. |
| 233 | Supply,Installation and commissioning of OFC Splicing with pigtails and complete as per specification and directions of Engineer-in-Charg |
| 234 | Supply the Fibre Pigtail/patchcord 1mtr and complete as per specification and directions of Engineer-in-Charge. |
| 235 | Supply, Installation and commissioning of Control cables to be inserted in conduit pipe in trenches, cables to be laid in racks, cleated on walls, cable lugs, cables glands, conduits, cablejoints Screened cable unarmoured etc all Complete Works as per specification and directions of Engineer-in-Charge(CAT-6 Delink cable) |
| 236 | Desiging, supplying, installing, commissioning & testing of CCTV IR water proof camera suitable for upto 100ft.with IR Dome camera, control key board, DVR, Hard Disk, cables, UPT transreceivers etc. complete. Make- Hikvision, CP Plus, Evision, Honeywell with 8 nos camera |
| 237 | EARTHING Providing electrical system's earthing as per latest IS 3043, and the work shall include the following :Earthing system comprising of copper earth plate (600 × 600 × 3.15 mm thick), G.I. strip (25 × 5 mm), G.I. pipe of 40 mm, 2.7 metre long with mesh covered funnel.Digging 900 mm dia earthing pit to suitable depth for burying the main electrode in the pit. The pit shall be filled with alternate layers of salt and charcoal/coke, 150 mm thick around the pipe to the entire depth.An inspection chamber of 300 × 300 × 300 mm size shall be constructed with Fly Ash Brick in CM (1:6) in foundation and plinth. The chamber shall be provided with CI/MS cover hinged to the frame, etc., all complete as per the direction of the Engineer-in-Charge. |
| 238 | Supply, Installation of Control Desk -1 no., Table - 1 no. & Chairs - 2 nos. at Control Room as per direction of Engineer- In charge. |
| 239 | Supply, Installation and commissioning of energy efficient inverter split AC 2 Ton 5 Star |
| 240 | CABLE TRENCH: Excavation in unpaved areas of earth in work sites for conventional cable trenches for a depth upto 1.2metres or below towards laying of 40mm dia HDPE pipe along water Pipeline including backfilling the trench, job complete in all respects, including all labour and materials complete as per specification and directions of Engineer-in-Charge. |
| 241 | Hot Dip Galvanised Tees for Cable Tray, |
| 242 | Hot Dip Galvanized Bends for Cable Tray |
| 243 | Supply, Installation and commissioning of cable tray 80mm width to wall, celling with necessary bracket, for laying of power and data cable etc. as per specification. all Complete Works. |
| 244 | Supplying,Installation & testing of network gateway, often including firewall, VPN, and traffic management features of (Firewall throughput 7000Mbps, Firewall IMIX - 2900Mbps, IPS throughput - 1355Mbps, Threat protection throughput - 330Mbps, Concurrent Connection - 1600000, New connection/sec - 44400, Xstream SSL/TLS Inspection - 420Mbps, Xstream SSL/TLS Concurrent connections - 81924G and comlpeted as per specification and Ingineering_In-Chargeas. |
| 245 | HOUSE SERVICE CONNECTIONS |
| 246 | Supplying all materials, Labour & T&P for providing New House connections to beneficiaries from PHE Deptt./ WATCO CI/ DI pipe line to the property of beneficiaries/ Repair of House connection with extension of service etc. including earth work excavation, cutting of concrete / Metal/ BT road, refilling the trenches & making good to the damaged road with CC (1:2:4) after completition of the work, lifting of excess excavated materials/ debrises from work site & disposing within 5 KM radious by mechanical transport, fixing 1/8\\" dia brass/ GM ferrule with following dia. composite Strap Saddle in the CI/DI pipe line, cutting holes in brick/ stone/ RCC masonary work, repair the broken holes, cost of uPVC Schedule - 80 pipe (25 mm / 20 mm dia up to 7.0mtr /10 mtr respectively ) & fittings, 1 No of PVC Tap of approved make etc. complete as per technical & PH specification and direction of Engineer - in- Charge.(New House connection) |
| 247 | New House Connection 100 MM |
| 248 | New House Connection 150 MM |
| 249 | Supplying all materials, Labour & T&P for providing New House connections to beneficiaries from PHE Deptt./ WATCO CI/ DI pipe line to the property of beneficiaries/ Repair of House connection with extension of service etc. including earth work excavation, cutting of concrete / Metal/ BT road, refilling the trenches & making good to the damaged road with CC (1:2:4) after completition of the work, lifting of excess excavated materials/ debrises from work site & disposing within 5 KM radious by mechanical transport, fixing 1/8\\" dia brass/ GM ferrule with following dia. composite Strap Saddle in the CI/DI pipe line, cutting holes in brick/ stone/ RCC masonary work, repair the broken holes, cost of uPVC Schedule - 80 pipe (25 mm / 20 mm dia up to 7.0mtr /10 mtr respectively ) & fittings, 1 No of PVC Tap of approved make etc. complete as per technical & PH specification and direction of Engineer - in- Charge.(House service connection) |
| 250 | With 100mm dia distribution main |
| 251 | With 150mm dia distribution main |
| 252 | Supplying all materials, Labour & T&P for providing Smart Domestic water meter , Horizontal inferential multiget type with magnetic drive and dry dial suitable for Ambient 500 C Temperature duly sealed against tampering complete with coupling at both ends and conforming to class B as per ISO 4064 along with manufacturer's test certificate including cost of all materials & labour etc with OIML/MID certification for abroad and FCRI for India including 36 months guarantee etc complete . |
| 253 | 15mmdia |
| 254 | Supplying , all materials , labour , T&P, for Construction of RCC framed Boundary wall size (350 mtr length x 1.80 Mtrs.brick wall heigh above plinth beam) with Fly ash brick filler wall as per the specifications and directions of Engineer-in-charge |
| 255 | Supplying , all materials , labour , T&P, for design & Construction of 2 leaf SS Gate fixed with RCC pillar 2 leaf SS gate (1.8m height x 6.0m) @ 30kg per sqmtr = 324kg & 1 leaf SS gate size ( 1.30mx 1.8mt ht.) 30kg/sqmtr=70.2kg as per the specifications and directions of Engineer-in-charge. |
| 256 | Supplyting , all materials , labour , T&P, for design & Construction of CC Approach Road shall be of 50.00 x 4.00 mtr (width) with Hard soil/Morrum filling – 1.0 Mtr, Crusher Dust-0.1 Mtr with 40 mm size metal filling in sub-base – 0.1 Mtr and rough stone (300mm size) dry packing in berms & aprons including CC (1:3:6) of 100mm thick, CC (M-30) of 150mm thick for CC pavement etc.,.as per the specifications and directions of engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysSep 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender