Shipping Government Departments Closing in 10 days TDR #57143537

Tender For Providing Interior Works To The Central Documentation Complex (Cdc) Building (First Floor - North Wing) Of Kamarajar Port At Chennai

Issued by Government Departments · Chennai, Tamil Nadu
Tender Value
68.90 Lakhs
Estimated cost
Bid Submission
02 Sep 2026
10 days left
EMD
1.38 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing Interior Works To The Central Documentation Complex (Cdc) Building (First Floor - North Wing) Of Kamarajar Port At Chennai

BOQ

Name of Work:- PROVIDING INTERIOR WORKS TO THE CENTRAL DOCUMENTATION COMPLEX (CDC) BUILDING (FIRST FLOOR - NORTH WING) OF KAMARAJAR PORT AT CHENNAI
Sl. No. Item Description
1CIVIL WORKS
2DemolishingDismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3 sq. metres
3Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :
4Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead - For thickness of tiles 10 mm to 25 mm
5Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead
6Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead
7Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge
8Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
9Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps : 100 mm diameter
10Providing EICHER truck transportation for the carting away the serviceable materials including Loading and Unloading manpower and deliver the materials to Ennore port ware house as per the direction of Engineer in Charge.
11Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
12Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge - With average thickness of 120 mm and minimum thickness at khurra as 65 mm
13Providing 12 mm cement plaster of mix -1:4 (1 cement: 4 fine sand) as directed at the site including all labour, materials, tools, equipments, scaffolding, etc. Complete.
14Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) approved make in colours laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm includingpointing the joints with white cement and matching pigment etc.,complete.
15Providing wall dadoing with Ceramic tiles (Johnson/Kajaria/Nitco or equivalent) (Plain) of size 300mmx200mm size or nearest size and of 6mm nominal thick as available in the market and approved colour and shade set in cement mortar 1:3 (1 cement : 3 crushed stone sand) 12mm thick joints neatly pointed with white cement added with pigment to match the colour of the tiles, curing all as directed at site of work including cement and all other materials, labour, tools, equipments., etc complete
16Providing and fixing of 150mm aluminium profile skirting for the partitions as directed at the site inclding all labour, materials, tools, equipments, etc,. Complete. BASIC COST OF SKIRTING - 100
17PLUMBING AND SANITARY FITTINGS
18Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc - INTERNAL PIPE LINES
1915 mm nominal dia Pipes
2020 mm nominal dia Pipes
2125 mm nominal dia Pipes
2232 mm nominal dia Pipes
23Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.- External work
2440 mm nominal dia Pipes
2550 mm nominal dia Pipes
26Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes
2775 mm diameter
28110 mm diameter
29Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion
30Coupler- 75 mm
31Coupler- 110 mm
32Single pushfit Coupler - 75mm
33Single pushfit Coupler - 110mm
34Single tee with door - 75mm
35Single tee with door - 110mm
36Bend 87.5° - 75mm
37Bend 87.5° - 110mm
38Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete
39110mm
40Providing and fixing C.P. brass stop cock (concealed) of standard design and of -15mm nominal bore
41Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 - 15mm nominal bore
42Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore
43Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms
44Providing and fixing CP Health Faucet with hose and other required accessories to complete in all aspects
45Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
46Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
47Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, includiing painting of fittings and cutting and making good the walls and floors wherever required: Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern
48Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge
49Providing and fixing PTMT grating of approved quality and colour - 150 mm nominal size square 100 mm diameter of the inner hinged round grating
50Providing and fixing of Ceramic Urinal divider of size 350 x 675 x 130mm of Parryware Make or Equivalent to be fixed on to the existing urinal area in Gents toilet with all required Hardwares and to complete in all aspects as per the direction of EIC
51Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
52Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge.Exhaust Pipe for Pantry
53Supplying, Fixing, installation, testing and commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. in confirmation to SMACNA/IS and as per specifications complete etc. as required Dia 200 MM
54PAINTING
55Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth as directed at the site including all labour, materials, tools, equipments, scaffolding, etc. Complete.
56Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour - Two Coat - as directed at the site including all labour, materials, tools, equipments, scaffolding, etc. Complete.
57Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches as directed at the site including all labour, materials, tools, equipments, scaffolding, etc. Complete.
58White washing with lime to give an even shade : New Work ( Three or More Coat) as directed at the site including all labour, materials, tools, equipments, scaffolding, etc. Complete.
59ALUMINUM WINDOWS
60Providing and fixing Aluminium Extruded Sections (for Doors, Windows, Ventilartors, Partitions, False Ceiling etc) as directed including charges for anodising for 15 micron thickness -With Powder Coating of any colours all as directed by Engineer-in-Charge, including all labour, materials, tools, equipments, etc. Complete.
61Providing and fixing Rubber Beading for Aluminium Glazed windows as directed by Engineer-in-Charge, including all labour, materials, tools, equipments, etc. Complete.
62Providing and fixing Lock for Aluminium Sliding Windows as directed by Engineer-in-Charge, including all labour, materials, tools, equipments, etc. Complete.
63Providing and fixing Plain Glass - 4mm thick as directed by Engineer-in-Charge, including all labour, materials, tools, equipments, etc. Complete.
64Providing and fixing Metal Screws (for Aluminium Doors, Windows etc)-75mm x 8mm as directed by Engineer-in-Charge, including all labour, materials, tools, equipments, etc. Complete.
65DOORS
66Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately)-Second class teak wood
67Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters-35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
68Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete - 125x64x2.50 mm
69Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete
70Providing and fixing chromium plated brass handles with necessary screws etc. complete : 125mm
71Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete - 150x10 mm
72PARTITIONS
73Providing and fixing 70mm thick full height laminate finished ply wood partition using 25x50mm anodised aluminium section frame work at 600mm c/c both ways with horizontal noggings at floor and at soffit, bothsides skinning with 9mm thick plywood. All electrical, network switch boxes, nitches to be boxes / packed with adequate reinforcment using plywood. The aluminium channel to be provide at intersection of 2 materials all as directed by engineer-in-Charge including all labours, materils, tools equipments, etc. Complete.
74Providing and Fixing 12mm toughened glass partition fixed with aluminium profile framing all around and firly fixed on to the floor and with top support on the ceiling and partition and to complete in all aspects
75Providing and fixing wall panelling made out of GI framing cladded with 12mm ply and finished with 1mm laminate as per approved shade and all the exposed edges shall be fixed with 2mm edge binding tapes and to complete in all aspects and in approval and direction of Engineer in charge.
76Providing and fixing of Pantry dining counter of depth 600mm fixed with vertical support divider at 900mm interval made out of 19mm waterproof ply finished with 1mm laminate as per approved colour and all exposed edges shall be finished with 2mm edge binding tapes in top counter and the vertical dividers and the to complete in all aspects including all required hardwares.
77FALSE CEILING
78Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ? 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking silhouette pattern T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge with 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6 sqm )
79Providing and fixing Gypsum false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
80Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal silhouette pattern T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondaryintermediate cross-T of size 24x32 mm of length 600mm to formgrid module of size 600 x 600 mm, suspended from ceiling usinggalvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The workshall be carried out as per specifications, drawing and as per directionsof the Engineer-in- Charge with 15 mm thick tegular/butt edged without perforation plain/designer light weight calcium silicate Anti-Microbial Bio-Safe coated false ceiling tiles Confirming to JIS-Z2801 and ASTM G
81MISCELLANEOUS
82Providing and fixing of Frosted film stickering / Suncontrol with pattern as approved on plain glass surface including cleaning the glass surface & wiping of excess water while installing all works complete as per the direction of site engineer.
83Providing and fixing of Roller Blinds made of 38mmx38mm aluminium extruded top rail with powder coated finished enabled with control Mechanism to be louvolite and chain must be metal. Stops to be fitted top & bottom to eliminate over-run and it should have straight edge finish. The blinds should be of approved manufactures and complete as per the approved shade and texture.( Basic cost Rs 200/-)
84Providing and fixing of Signage for the reception backdrop of size 1800 mm legth with 900 x 900mm logo made out of acrylic 4mm sheet cut to shape and logo printed and fixed on to the 4mm acrylic sheet and firmly fixed as per direction of engineer in charge
85Providing and fixing Room Signages for all the areas as per instruction made out of an 2 mm acrylic sheet printed as per approval and fixed as per direction of enginner incharge.
86ELECTRICAL
87Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - LIGHTING DB
884 Way ( 4+12) Double Door
89Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required - 63 A
90Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required - 40A
91Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
92Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) - POWER DB
938 way (4 + 24), Double door
94Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. 125 A, 36 KA 4 Pole
95Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required.Details of cost for one each
96Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
97Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) - UPS DB - 12 way Double Door DB
98Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required - 40A
99Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
100Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required - 40 A
101Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required
102Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required - 40A
103Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required - AC
104Point wiring in PVC conduit, with modular type switch. Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated multistrand copper conductor wires in surface / PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated multistrand copper conductor wires etc. as required (Group B) and as per technical specification and as per latest IS / IEC
105Point wiring in PVC conduit, Wiring for group controlled (looped) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated multistrand copper conductor wires in surface / PVC conduit, (without independent switch etc.) earthing the point with 1.5 sq.mm FRLS PVC insulated multistrand copper conductor wires etc.as required ( Group-B ) and as per technical specification and as per latest IS / IEC
106Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
107Supply and Fixing Power plug Point Modular type accessories: Supply and fixing of metal box of GI box with modular plate and cover in front on surface or in recess , including providing and fixing of 3 pin 5/6 amps. modular socket outlet and 5/6 amps. modular switch, connections, painting etc. as required. (For light plugs) and as per technical specification and as per latest IS / IEC
108Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. and as required and as per technical specification and as per latest IS / IEC
109Supplying & fixing suitable size Gl box with modular plate and cover in fronton surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
110Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
1114 x 4 Sq.mm for UPS Wiring
112Supply and clamping of 3 1/2 x 35 sq. mm. PVC LTUG armoured cable on post or on wall with MS clamps
113Supply and providing cable end termination of 3-1/2 x 35 sq.mm. PVC LTUG aluminium armoured cable with necessaryaluminium cable sockets by crimping etc with electrical connection complete
114Supply and fixing of brass cable gland for 3-1/2 x 35 sq.mm. PVC armoured LTUG cable with earth connection
115Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
1162 X 4 sq. mm + 1 X 4 sq. mm earth wire
1172 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
118Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required
11940 mm
120Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required
121150 mm X 150 mm X 60 mm deep
122200 mm X 250 mm X 60 mm
123LIGHT FITTINGLED Panel light 2x2 ft. (System lumen efficacy =120 <135 lm/Watt) Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.=0.95, IP20, CRI =80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with OEM warranty. System lumen efficacy =120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness =1.20 mm) - 40 W
12422W LED Down lighter (SMD Type) (System lumen efficacy >135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.=0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with OEM warranty.System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . 22 W
125Providing and fixing of 12\\"exhaust fan of approved make for ups and bathrooms to be fixed in grills or walls with all necessary fixing accessories,arrangements and etc. Cost include all hardwares, screws, clamps and etc.Fan make & model to be approved by engineer / architect. (Make of exhaust fan- Almonard.)
126Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req 1200mm, service value = 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
127FIRE DETECTION SYSTEM
128Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required
129Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required
130Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
131Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required - 4 Zone
132Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required
133Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers
134NETWORKING AND CCTV
135Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 9 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1O, Port based, O-in-O, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, OoS: 802.1P, 8 queues per port, OoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India,
13624 port Layer 2 Non-PoE Network Switch
137Supplying Installation Testing and Commissioning of 2 MP IP IR Dome Camera having following specifications, type of lens and features etc AS PER CPWD SPECIFICATIONS1) Signal System: PAL/NTSC, Signal to Noise Ratio: >50 dB,Camera should display Camera title, Date & Time in live & recorded video2)Image Sensor: 1/2.8\\" or better progressive Scan CMOS to get colorimage even at night condition(Minimum Illumination: 0.006 Lux@ F1.4,AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 3) Compression (Minimum):-Video:- H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.7234) Wide Dynamic Range:- WDR (120dB or more)5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates :- Triple streaming , configurable(Main stream: 2MP (1920 × 1080)@25/30 fps,Sub streams minimum:720P@25/30 fps).7) Image Setting: Rotate Mode, saturation, brightness, contrast,sharpness adjustable through client software or web browser, EdgeAnalytics: Tripwire, Intrusion, Motion Detection8) Cyber Security: AES 256-bit Encryption, Configuration encryption,trusted execution, Digest, security logs, account lockout, syslog, videoencryption, IP/MAC filtering, HTTPS, trusted upgrade, trusted boot.
1389) Onboard Storage: Camera should support built-in MicroSD/SDHC/SDXC Card slot upto 512 GB. It should be supplied withminimum 128GB memory Card.10) Recording Management: Format SD, overwrite, storagemanagement, video to NAS device11) Alarm Trigger : Motion/tampering detection; audio detection; networkdisconnection detection; IP conflict detection; memory card statedetection; memory space detection12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP,HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP,RTSPS, unicast13) System Capability: ONVIF, Camera shall support open source VMS14) Ethernet: 1 RJ 45 10/100 Ethernet port15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out forExternal Mic. and Speakers as per site requirement.16) Power Input: The camera should support simultaneous dual powerinput—12 VDC (via power adapter) and PoE (802.3af)—to ensurecontinuous operation in the event of a failure in one power source.17) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE2MP (@ 25/30fps@1080P (1920×1080)) IP IR Dome Camera with 2.8/ 3.6mm fixed lens
139Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below As per CPWD SPECIFICATION in ITEM 40.10 IN AOR EM 2025
14008 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9, 2nd screen: 1/4/8/9
141Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s TransferRate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. - 10TB
142Supplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with 3840x2160resolution or better, USB playback, bluetooth andmiracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc. as required. 32 inch or Larger
143Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter - 1 RUN of Cat6 Cable
144Supplying and fixing 24U Rack with 4 inch Castor wheels and front brake Floor Standing Rack with Main Frame Pillar of 1.25mm powder Coated CRCA Sheet with removable side panels, L- Shape adjustable Vertical Mounting Rail of 2mm with 'U'Marking completely knocked-down condition (CKD) Shape, fitted with 4 number cooling fans, minimum 5nos two line cable entry/exit provision at top and bottom with rubber protection, Front door 5mm Toughened Glass with MS frame or MS perforated with lock, Rear MS vented or perforated door, Powder coated Color- RAL- 7035 or black, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
145Supplying and fixing 42U Rack with 6 inch Castor wheels and front brake Floor Standing Rack with Main Frame Pillar of 1.6mm CRCA Sheet with removable side panels, L- Shape adjustable Vertical Mounting Rail of 2mm with 'U'Marking completely knocked down condition (CKD) Shape, fitted with 4 number ooling fans, minimum 8nos two line cable entry/exit provision at top and bottom with rubber protection, Front door 5mm Toughened Glass with MS frame or MS perforated with lock, Rear MS vented or perforated door, Powder coated Color- RAL- 7035 or black,complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
146Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interopertability.
147Supply and fixing 1 metre mounting cord (Systimax).
148Supply and fixing RJ45 Connectors (Metal Connector)
149HVAC SYSTEM
150Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU),surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU),copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Warranty as per Original Equipment Manufacturer (OEM) for both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).
1512.0 TR with 5 Star BEE Rating
152Supply and installation of 5 KVA capacity Double Booster Voltage Stabilizer with time delay relay (V-Gurad / Equivalent)
153Supply and laying of 5/8\\" and 3/8\\" copper pipe (Extra beyond 3 metres supplied with AC unit)
154Supply and providing of pipeline nitrle rubber insulationfor Refrigerant and drain pipe lines.
155Supply and fixing of MS stand for fixing outdoor unit
156Supply and fixing of water drain pipe line (1” PVC Pipe)
157Supply and Providing of 3c x 4 sq.mm copper flexible cable laid in pvc conduit with neccssary works etc…
158FURNITURE Please Enable Macros to View BoQ information
159FURNITURE Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57143537
AUTHORITY Government Departments
TENDER VALUE 68.90 Lakhs
LAST DATE 02-09-2026
Authority
Authority Name Ennore Port Limited
Work Description Tender for Providing Interior Works To The Central Documentation Complex (Cdc) Building (First Floor - North Wing) Of Kamarajar Port At Chennai
Basic Detail
Tender No 2026085121
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 21 Aug 2026
Submission Date 02 Sep 2026
Open Date 03 Sep 2026
Finance
Tender Value 68.90 Lakhs
Tender Fee Ref. Documents
EMD 1.38 Lakhs
Exemption Not Available
Document List
a8243a04-6ec7-4f58-8475-6fb953e893df.html
BOQ_970226.xls
TECHNICALBID.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Sep 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

a8243a04-6ec7-4f58-8475-6fb953e893df.html

xls

BOQ_970226.xls

pdf

TECHNICALBID.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders