Defence Statutory Bodies & Commissions/Committees Closing in 23 days TDR #57142379

Tender For Comprehensive Maintenance Of Offrs Md Accn In Site 3 & 4 And Misc Repair To External Electric Supply In The Aor Of Age B/R-I Under Ge(West) Ferozepur Cantt

Issued by Statutory Bodies & Commissions/Committees · Firozepur, Punjab
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 Sep 2026
23 days left
EMD
1.07 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Firozepur → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Comprehensive Maintenance Of Offrs Md Accn In Site 3 & 4 And Misc Repair To External Electric Supply In The Aor Of Age B/R-I Under Ge(West) Ferozepur Cantt

BOQ

Name of Work:- COMPREHENSIVE MAINT OF OFFRS MD ACCN IN SITE 3 & 4 AND MISC REPAIR TO EXTERNAL ELECTRIC SUPPLY IN THE AOR OF AGE B/R-I UNDER GE(WEST) FEROZEPUR CANTT
Sl. No. Item Description
1Demolition of unreinforced cement concrete in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and directed.
2Dismantling floor, hearth or wall/stone tiling including cement mortar bedding (but not backing), removing broken tiles and rubbish off the premises from site complete all as specified and directed.
3Demolition of brick work built in cement mortor including all quoins,arches,pillars etc complete all as specified and directed.
4Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc complete all as specified and directed.
5Dismantling structural steel work in cluding doors, gates but excluding framed truss etc complete all as specified and directed.
6Dismantling brick tiles or terracing tiles, single layer on roofs jointed and pointed in cement mortar including removal of grass vegitation including roots near out let of RWP and OHT staging area or specifically ordered in writing complete all as specified and directed.
7Demolition of mud phuska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part hereof ) and removing from site to adistance exceeding 250m but not exceeding 500m complete all as specified. Note :- Demolition of Mud puska to be cut in average thickness from top surface of roof for creating the slope as directed
8M&L for Cleaning and removing all scale and dirt, etc., from tanks of capacity exceeding 250 Litres but not exceeding 500 litres, including writing letters as CLEANED ON Month and year by using synthetic enamel paint (height of each letter not less than 5 cm) as affected, complete all as specified and directed.
9M&L for Cleaning and removing all scale and dirt, etc., from tanks of capacity exceeding 500 Litres but not exceeding 1000 litres, including writing letters as CLEANED ON Month and year by using synthetic enamel paint (height of each letter not less than 5 cm) as affected, complete all as specified and directed.
10Easing of wooden window shutters/CB shutters (One unit shall comprise of one window/ CB/ Showcase irrespective of number of leaves) for properly closing/opening, tightening of hinges or changing the position of hinges, adjustment of tower bolts sliding bolt including necessary nail and screwsetc.
11Easing of wooden door shutters (One unit shall comprise of one Panelled or skeltion door shutter irrespective of number of leaves) for properly closing/opening, tightening of hinges or changing the position of hinges, adjustment of tower bolts sliding bolt including necessary nail and screws etc.
12Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
13Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
14Taking down cement plaster of any description on brick walls or concrete or stone and ceilings including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
15Taking down chowkats or frames with shutters (without taking off shutters from the frame) of size not exceeding 1.5 Sqm each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts, and removing from site complete all as specified and directed.
16Taking down chowkats or frames with shutters (without taking off shutters from the frame) of size exceeding 1.5 Sqm but not exceeding 4 Sqm each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts, and removing from site complete all as specified and directed.
17Taking down chowkats or frames with shutters (without taking off shutters from the frame) of size not exceeding 1.5 Sqm each and refixing in the same opening complete all as specified and directed.
18Taking down chowkats or frames with shutters (without taking off shutters from the frame) of size exceeding 1.5 Sqm but not exceeding 4 Sqm each and refixing in the same opening complete all as specified and directed.
19Taking down dhutters of any description exceeding 1.00Sqm but not exceeding 2.00Sqm each and refixing in same opening and in same position complete all as specified and directed.
20Demolition of boarding, any description, fixed in any postion with nails or screws complete all as specified and directed.
21Demolition of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, complete all as specified and directed.
22Cutting holes in brick walls exceeding one brick but not exceeding half brick, built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) Type B-1 as required complete all as specified and directed. Note:- Depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall.
23M&L for Hardcore of broken stones and boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
24M&L for Lean Cement Concrete (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in back filling of steel frames/chowkhats complete all as specified and directed.
25M&L for brick work built in cement mortar (1:6) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed.
26M&L for brick work (EXCEPT BRICKS) built in cement mortar (1:6) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed. Note:- Old seviceable tiles shall be re-used retrieved after demolition of brick work.
27M&L for brick work in half brick thick wall built in cement mortar (1:4) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed.
28S&F Pressed steel frames made of 1.25mm thick CRCA sheet of profile 125x60mm for door and window frames with one or more rebates incl lock strike plate, shock absorbers, 20mm dia 60mm long MS conduit for housing of a drop bolt, butt hinges, hold fasts/lugs etc and treating of internal surfaces of chowkhats and hold fasts/lugs with a coat of coal tar or black paint incl hinges, hold fasts/lugs etc including making good jambs portion by providing plaster in CM 1:4 and finishes as per existing complete all as specified.
29S&F Pressed steel frames made of 1.25mm thick CRCA sheet of profile 105x60mm for door and window frames with one rebate including lock strike plate, shock absorbers, 20mm dia 60mm long MS conduit for housing of a drop bolt, butt hinges, hold fasts/lugs etc and treating of internal surfaces of chowkhats and hold fasts/lugs with a coat of coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified.
30S&F 2nd class hardwood Plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, all as specified and directed.
31S&F 2nd class Hard Wood plain fillets square, rectangular in section clean swan, secured with nail or band including two coats of paint over a coat of primer n.exc 13 sqcm complete all as specified and directed.
32S&F 35mm thick 2nd class hard wood (Hollock), glazed and skeleton shutters open rebated and prepared to receive glass/ gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitered beads for securing glass etc for doors, size of members as specified in clause 8.24 (a) of MES Schedule Part-I Section-8, complete all as specified and directed.
33S&F 35mm thick, 2nd class hard wood (Hollock), Plain framed, panelled wooden shutter (any number of panels) of second class hard wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: suppliedand fitted to chowkats complete all as specified and directed.
34S&F Powder coated of ( any colour ) aluminium door window , ventilator etc fixed / sliding or pull and push type in shutter frames or shutters with two/three track sliding aluminium frame of Jindal /Hindalco (or) Equivalent make of approved size, including necessary joining cleats, glazing clips,powder coated aluminium snap beading, screws, including necessary anodised aluminium fittings like handles etc including taking down complete all as specified as per manufacturers instructions.Note: EPDM Rubber beading/gasket measured and paid seperatley.
35S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-Charge,complete all as specified and directed.
36S&F EPDM Rubber beading around glass in aluminium windows /ventilator shutters, complete all as specified and directed.
37S&F 25 micron Solar control film reflective sticked to glass panes as per manufacturers instruction complete all as specified and directed.
38S&F in replacement Factory Made Box Type Steel Windows with glazing bars made of ERW tube hollow \\"P\\" section of size 60mmX25mm double rebated outer frame comprising double shutters side hung skelton & glazed shutters, frame of ERW tube \\"P\\" section size 50mmX20mm with two openable leaf for each shutter consisting two Nos sash bar of T-section 20mmX3mm welded to frame with one vertical mullion of ERW box type T-section of size 60mmX25mm and mild steel flat iron 2mm thick welded/ screwed to frame for fixing of wire gauge to frame/ shutters as given below and all as shown on Drawing No. CEJZ/TD-1019/08 and CEJZ/TD-1020/08 Sheet No. 1/3 to 3/3 including taking down of old existing window complete all as specified and directed :- (i) Hold fast,150mm long of flat iron 12mmX3mm- 04Nos per window (ii) Handle of Z section 20mmX25mm,100mm long-01Nos per leaf (iii) MS Tower bolt 150mm long-02 Nos per leaf (iv) Z section 20mmX25mm,100mm long stopper -01 Nos per leaf (v) Cleat 55mm long of hollow square 15mmX12mm -02 Nos per leaf (vi) MS pintol hinges size 75mmx12mm- 2 Nos. per leaf (vii) Making good dismantled portion in PCC 1:2:4 type B-1 for hold fasts (four Nos for each window). (viii) Preparation of steel surfaces of windows and grills and guard bars and applying one one shop coat of zinc chromate primer and two coats of synthetic enamel paint after installtion at site. Note: Glass panes and grills & guard bars shall be measured and paid for separately .Area shall be measured flat for one side only for the purpose of measurement and payment .
39S&F in replacement Factory Made Box Type Steel Windows without glazing bars made of ERW tube hollow \\"P\\" section of size 60mmX25mm double rebated outer frame comprising double shutters side hung i.e. guaged shutters, frame of ERW tube \\"P\\" section size 50mmX20mm with two openable leaf for each shutter consisting two Nos sash bar of T-section 20mmX3mm welded to frame with one vertical mullion of ERW box type T-section of size 60mmX25mm and mild steel flat iron 2mm thick welded/ screwed to frame for fixing of wire gauge to frame/ shutters as given below and all as shown on Drawing No. CEJZ/TD-1019/08 and CEJZ/TD-1020/08 Sheet No. 1/3 to 3/3 including taking down of old existing window complete all as specified and directed :- (i) Hold fast,150mm long of flat iron 12mmX3mm- 04Nos per window (ii) Handle of Z section 20mmX25mm,100mm long-01Nos per leaf (iii) MS Tower bolt 150mm long-02 Nos per leaf (iv) Z section 20mmX25mm,100mm long stopper -01 Nos per leaf (v) Cleat 55mm long of hollow square 15mmX12mm -02 Nos per leaf (vi) MS pintol hinges size 75mmx12mm- 2 Nos. per leaf (vii) Making good dismantled portion in PCC 1:2:4 type B-1 for hold fasts (four Nos for each window). (viii) Preparation of steel surfaces of windows and grills and guard bars and applying one one shop coat of zinc chromate primer and two coats of synthetic enamel paint after installtion at site. Note: Wire cloth and grills & guard bars shall be measured and paid for separately .Area shall be measured flat for one side only for the purpose of measurement and payment .
40S&F in replacement Factory Made Box Type Steel Ventilators side / top hung with glazing bars or dovetailed or welded made of ERW tube \\"P\\"-section of size 60mmx25mm outer frame ( single rebated), comprises glazed shutter, frame of ERW tube and mild steel flat iron 2mm thick welded/screwed to frame for fixing of sheet glass including fixture and fittings like as Stopper, Cleat, Pintal hinges, holdfast etc all as shown onDrawing No. CEJZ/TD-1019/08 and CEJZ/TD-1020/08 Sheet No. 1/3 to 3/3 including taking down of old existing window complete all as specified and directed:- Note : 1. Grills and guard bars, Sheet glass and wiremesh shall be measured and paid separately. 2. Making good dismantled portion in PCC 1:2:4 type B-1 for hold fasts (four Nos for each window). 3. Preparation of steel surfaces of ventlators and applying one one shop coat of zinc chromate primer and two coats of synthetic enamel paint after installtion at site. 4. Area shall be measured flat for one side only for the purpose of measurement and payment .
41S&F 50mmx47mm size solid PVC door frame made out of 5mm plain colour PVC sheet reinforced with MS square tube, complete all as specified shown on drawing and specified and directed.
42S&F factory made 30mm thick (style) solid panel PVC door shutter consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified shown on drawing and specified and directed.
43S&F 16mm Solid PVC board plain colour ,fixed with screws or adhesive with complete accessories (magnetic catcher, knobs) as in shelves/shutters with rebates fixed on PVC on three sides as in supporting block to shelves complete all as specified and directed.
44S&F19-20mm thick Second Class Hard Wood Boarding in any situation Clean sawnwith butt joints fixed with nails in shelves; partitions and shelves of built-in cupboards, almirahs, book cases, toilet boxes, racks, pelmets and similar work complete all as specified and directed.
45S&F in repairs 19-20mm thick pre-laminated particle board, flat pressed single layer type or three layer type with BWR type adhesive, medium density interior grade having one side decorative lamination and other side balancing white lamination as in pelmet box or cup board shelf including 6 mm thick teak wood leaping on three sides and 20mm thich on hanging side & french polishing to edging, complete all as specified and directed.
46S&F 100mm size butt hinges of extruded aluminium alloy with galvanised steel hing pins, anodised and type B-21 complete all as specified and directed.
47S&F 125mm size butt hinges of extruded aluminium alloy with galvanised steel hing pins, anodised and type B-21 complete all as specified and directed.
48S&F 200mm long aluminium anodised barrel tower bolts of extruded section and fixed with steel screws complete all as specified and directed.
49S&F 150mm size aluminium door handle, extruded aluminium alloy, fabricated type complete all as specified and directed.
50S&F stainless steel continous (piano) hinges of mild steel bright finish or electro galvanised with flap (when open) 40mm, fixed with steel screw complete all as specified and directed.
51S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
52S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, with 150mm overall length of cover plate fixed in floor complete all as specified and directed,
53S&F 300mm size mild steel helical door spring ordinery rat rail rod pattern spring including roller and roller plate complete all as specified and directed,
54S&F 100mm size hasp and staple aluminium anodised including bolt to hinge plate and fixed with screws complete all as specified and directed.
55S&F in repairs 100mm size, 4-Lever Aluminium Mortice lock, vertical type complete all as specified and directed.
56S&F PTMT tower bolts, 200 mm long and fixed with steel screws complete all as specified and directed.
57S&F PTMT butt hinges,100mm long, fixed with steel screws with brass /bronze hinges pin complete all as specified and directed.
58S&F PTMT handle 125mm long fixed with steel screws complete all as specified and directed.
59S&F hydraulically extruded aluminium body door closer regulated designation No 3 universal type suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80 Kg etc complete all as speciified and directed.
60S&F Galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture not more than 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed.
61S&F in repairs Galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture not more than 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed.
62S&F 5.5mm thick, plain sheet glass, ordinary quality and glazing, with oil putty or with wooden beads (supplied alongwith shutters), in squares exceeding 0.50 Sqm in each pane complete all as specified and directed.
63S&F 3.0mm thick, plain sheet glass, ordinary quality and glazing, with oil putty or with wooden beads (supplied alongwith shutters), in squares n.exc 0.50 Sqm in each pane complete all as specified and directed.
64S&F in repairs 3.0mm thick, plain sheet glass, ordinary quality and glazing, with oil putty or with wooden beads (supplied alongwith shutters), in squares n.exc 0.50 Sqm in each pane complete all as specified and directed.
65S&F Mild steel screw bolts of 12 mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, but length of bolt exc 15cm and n exc 22.5cm long complete all as specified and directed.
66S&F Structural Steel Fe-410- W(Gde E-250) quality 'B' Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
67S&F Structural Steel Fe-410- W(Gde E-250) quality 'B' Rolled sections as in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of Fe 410-W(Gde-E- 250) quality-B complete all as specified and directed.
68M&L for Welding in repairs exc 6mm but n exc 9 cm in length, thickness of metal to be welded complete all as specified and directed.
69M&L for 75mm thick Plain Cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base and all other similar works complete all as specified and directed.
70M&L for 75mm thick Plain Cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection, surfaces finished even and smooth without using extra cement as in plinth protection including provision of construction joints and expansion joints filled with bitumen mixed with sand in ratio (1:1) complete all as specified and directed.
71M&L for Plain Cement Concrete (1:2:4) type B-0 using 12.5 mm graded crushed stone aggregate as in kerbs,mud stop, rounded or chamfered on edges including formwork complete all as specified and directed.
72M&L for 25mm thick Plain Cement Concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in surface finished rough to receive floor topping, surface finished even and fair complete all as specified and directed.
73M&L for 18 to 20mm thick Green Marble work of size not lessthan 1 Sqm each, in steps ,jambs,pillars,cooking platform and like including pointing in white cement 1:2 using marble dust with admixture of pigment to match with marble shade other than white and black types over a 15mm thick cement screed bed or bedding layer or plaster in cement mortar (1:4) complete all as specified and directed.
74M&L for 18 to 20mm thick Granite (table rubbed and mirror polished) 1 in steps ,jambs,pillars,cooking platform and like including pointing in white cement 1:2 using marble dust with admixture of pigment to match with marble shade other than white and black types over a 15mm thick cement screed bed or bedding layer in cement mortar (1:4) complete all as specified and directed.
75M&L for 10mm thick (square/ rectangular) Vitrified Tiles, dark shad, polished, area of each tile not exceeding 0.36Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.
76M&L for 10mm thick (square/ rectangular) Vitrified Tiles, light shade, polished, area of each tile not exceeding 0.36Sqm, in vertical surfaces such as skirtings, dados, risers and steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 10mm thick rendering cement plaster in cement mortar (1:4) complete all as specified and directed.
77M&L for 7 to 8 mm thick (square/ rectangular) Non-skid Ceramic Tiles coloured, premium quality, area of each tile exceeding 0.06Sqm but not exceeding 0.11Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.
78M&L for 7 to 8 mm thick (square/ rectangular) Non-skid Ceramic Tiles coloured, premium quality, Joint-free, area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.
79M&L for 7 to 8 mm thick (square/ rectangular) Non-skid Ceramic Coloured Tiles, Joint-free, premium quality, area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm, in vertical surfaces such as skirtings, dados, risers and steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 10mm thick rendering cement plaster in cement mortar (1:4) complete all as specified and directed.
80M&L for 7mm thick (Area 450 x 300mm / 450x350mm/ 350x250mm/300x200mm) Glazed Ceramic Coloured Tiles, in vertical surfacesX 7 mm th set and jonnted in cement slurry and pointed in white or coloured cement in vertical surfaces such as skirtings, dados, risers and steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 10mm thick rendering cement plaster in cement mortar (1:4) complete all as specified and directed.
81M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paverblocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
82M&L for 10 mm thick rendering cement plaster in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
83M&L for brushing neat cement slurry with 3 Kg of cement per square metre complete all as specified and directed.
84M&L for 15mm thick rendering cement plaster in cement mortar (1:4) on any faces of brick walls or concrete surfaces, finished even and fair without using extra cement complete all as specified and directed.
85M&L for 10mm thick rendering cement plaster in cement mortar (1:4) on fair faces of brick work or concrete surfaces in cement mortor 1:4 mixed with water profing comund @3% by weight of cement content as in verticle surfaces and finished even and smooth without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid separately
86M&L for 5mm thick rendering cement plaster in cement mortar (1:3) on ceiling surfaces, finished even and smooth without using extra cement complete all as specified and directed.
87M&L for 10mm thick screed bed or bedding layer in cement mortar (1:4) mixed with water proofing compound @ 3% by weight of cement or as per manufacturer's instructions, finished even and smooth without using extra cement on roof surfaces to have a smooth and uniform surface for laying of water proofing membrane complete all as specified and directed. . Note: WPC shall be measured and paid separately.
88Supply only Integral water proofing compound complete all as specified and directed.
89M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per sqm over a coat of bitumen primer @ 0.30 litre per Sqm including preparation of roof surfaces/ sunken portion and all surfaces of sunken portion complete all as specified and directed.
90M&L for One layer of APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surfaceby forced application complete all as specified. Polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet walls and shall be finished by a membrane flashing.Note: (i) Laying of APP based membranes shall be done by torch on method or as per manufacturer's instructions.(ii) A minimum overlap shall be 75mm length wise and 100 mm width wise of polymeric membranes respectively and sealed all overlaps and joints as manufacturer's instructions.
91M&L for preparation of surfaces of platered, brick, concrete, polymeric etc, of any description, over10cm in width or girth,not otherwise describedone and applying two coats of Solar Reflective Bituminous Aluminium paint @0.1 Kg/ Sqm over APP Membrane complete all as specified and directed.
92M&L for 40mm thick brick tiles laid on mud mortar or mud phuska and joints grouted flush and pointed flush as the work proceeds in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed.
93M&L for 40mm thick brick tiles (EXCEPT TILES) laid on mud mortar or mud phuska and joints grouted flush and pointed flush as the work proceeds in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed. Note:- Old seviceable tiles shall be re-used retrieved after dismantling brick tiles on roofs/terrace.
94M&L for 80mm thick average consolidated thickness mud phuska on flat roof ncluding 25mm thick mud plaster complete all as specified and directed. Note:- Old mud phuska shall not be re-used.
95S & F in repair Gypsum Board 6 to 7 mm thick in ceiling fixed with screw 60x60cm placed in ceiling (Angle 25mm X 25mm , Main tee 38mmX23mm ,Sub tee 23mmX23mm) incl aluminium anodised/powder coated snap grid frame 605X605 mm for false ceiling incl hanging arrangement complete all as specified and directed. (Note:- Taking down/distmantling shall be measured and paid for separately )
96Fix only in repair old serviceable Gypsum Board 6 to 7 mm thick in ceiling fixed with screw 60x60cm placed in ceiling (Angle 25mm X 25mm , Main tee 38mmX23mm ,Sub tee 23mmX23mm) incl aluminium anodised/powder coated snap grid frame 605X605 mm for false ceiling incl hanging arrangement,complete all as specified and directed. (Note:- Taking down/distmantling shall be measured and paid for separately )
97S&F in repair to Hollow PVC wall lining consisting of 5mm thick single side prelam PVC sheet instead of plain colour sheet inclusive of solvent cement and fixing on PVC frame as per specified in MES Schedule Part-I & II complete all as specified and directed.
98S&F 2 mm the fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with self tapping screw complete all as specified and directed.
99S&F 0.50mm thick Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specified complete all as specified and directed.
100S&F 0.50mm thick Pre- painted galvalume aluminum zinc coating GI based plain steel sheetof an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specified
101M&L for preparing new plastered surfaces of walls and distempering with two coats of distemper oil emulsion white or tinted over one coat of cement primer over 01mm thick plaster of paris putty to prepare surface even and smooth complete all as directed.
102M&L for preparing new plastered surfaces of walls and distempering with two coats of cement base paint over one coat of alkali resistant cement primer complete all as specified and directed.
103M&L for complete removal of existing treatment on walls and distempering with two coats of distemper oil emulsion white or tinted over one coat of cement primer over 1mm thick plaster of paris putty to prepare surface even and smooth complete all as specified and directed.
104M&L for Complete removal of existing treatment on Terra Cotta floor surfaces like a pathways pavers, chequered tiles, interlocking paver blocks , roof tiles etc including necessary praparion of surfaces and applying two coats of terra cotta over a coat of primer complete all as specified and directed.
105M&L for preparing new plastered surfaces of ceiling and applying three coats of lime white wash complete all as specified and directed.
106M&L for preparing old plastered surfaces of walls including washing, rubbing down and stopping distempered and painted surfaces and distempering with one coat of distemper oil emulsion white or tinted over one coat of 1mm thick wall care putty complete all as specified and directed.
107M&L for preparing old plastered surfaces of Ceilings including washing, rubbing down and stopping distempered and painted surfaces and distempering with one coat of distemper oil emulsion white or tinted over one coat of 1mm thick wall care putty complete all as specified and directed.
108M&L for preparing old plastered surfaces of walls upto three storey including washing, rubbing down and stopping distempered and painted surfaces, scaffoldings etc and distempering with one coat of cement base paint white or tinted complete all as specified and directed.
109M&L for preparing old plastered surfaces of walls upto three storey including washing, rubbing down and stopping distempered and painted surfaces, scaffoldings etc and distempering with two coats of cement base paint white or tinted over a coat of alkali resistant primer complete all as specified and directed.
110M&L for preparing old surfaces decorated plastered or unplastered surfaces of walls and applying one coat of lime white wash complete all as specified and directed. NOTE:-Preparation of old surface shall include brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots.
111M&L for preparing old surfaces decorated plastered or unplastered surfaces of Walls and Cornices, and applying one coat of lime colour wash complete all as specified and directed. NOTE:-Preparation of old surface shall include brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots.
112M&L for preparing old plastered surfaces of ceiling and applying one coat of lime white wash complete all as specified and directed. NOTE:-Preparation of old surface shall include brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots.
113M&L for preparation of new wood or wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
114M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
115M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer zinc chromate complete all as specified and directed.
116M&L for preparation of old steel surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
117M&L for preparation of old wood or wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
118M&L for writing letters or figures (Block Roman Italic and Indian ) 15 cm High on wall surfaces, so that the stand out boldly and solidly without showing signs of brush marks all as specified. (Note :- The letters to bewrite with in the black synthetic enamel painted back ground, it is measured and paid to Seperately)
119S&F 75mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls or floors complete all as specified and directed. Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.)
120S&F 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls or floor complete all as specified and directed.Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.)
121S&F 75mm dia PVC (SWR) bends any radius with oval type access door complete all as specified and directed.
122S&F 110mm dia PVC (SWR) bends any radius with oval type access door complete all as specified and directed.
123S&F 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
124S&F 15mm bore Galvanised Medium Grade Steel Water Tubing with all fittings and connections fixed complete to walls and celling or laid in floor, complete all as specified and directed.
125S&F 20mm bore Galvanised Medium Grade Steel Water Tubing with all fittings and connections fixed complete to walls and celling or laid in floor, complete all as specified and directed.
126S&F in repairs 15mm bore Bib Taps, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and directed.
127S&F in repairs 15mm bore fancy type, chromium plated, Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
128S&F in repairs 15mm bore fancy type, chromium plated, Stop valves, cast copper alloy, with long shank and cup concealed type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
129S&F in repair 125 mm chromium plated shower rose with or without swivel joints any size including fixing to steel pipe complete all as specified and directed.
130S&F in repair pressure Jet spray of chromium plated steel for EWC seats with and including including PVC connection and CP fittings complete all as specified and directed.
131S&F in repairs 15mm bore Pillar Taps, fancy type, chromium plated, cast copper alloy, with capstan heads, screwed down high pressure, with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
132S&F 32mm bore PVC waste pipe of suitable length to waste coupling pipe attached with rubber ring joints/ PVC threaded cup, fixed to waste coupling of sinks / WHBs/urinal of required length complete all as specified and directed.
133S&F in repairs 15mm PVC connections 450mm long heavy duty with brass nuts adaptors and washers and rubber gaskets at both ends complete all as specified and directed.
134S&F in replacement 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), three layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule hoisted and fixed including dismentling and taking down old unserviceable water tank capacity 500 litres complete as specified in SSR Part-I. complete all as specified and directed.
135S&F in replacement 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), three layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule hoisted and fixed including dismentling and taking down old unserviceable water tank capacity 1000 litres complete as specified in SSR Part-I. complete all as specified and directed.
136S&F in repair 15mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic float ball screwed for iron pipe complete all as specified and directed.
137S&F in repair 20mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic float ball screwed for iron pipe complete all as specified and directed.
138S&F Vitreous china wash down water closet pan (pedestal pattern)white/coloured cascade type640X360X690 (monolithic flush cistern type) Make: Jaquare & equivalent single picece wc with PP seat cover ,Hinges fixing accessories set including flush cistern with S-Trap of size 220mm all as per manufacturing instructions and all as specified and directed.
139S&F in repairs Wash Hand Basins, Vitreous China (flat back) white of size 550mm X 400mm including cutting for and pinning in ends of brackets or erecting stand including waste fittings, 32 mm bore PVC flush pipe with long screwed shucks and fly nuts and including PVC discharge pipe complete all as specified and directed.
140S&F in repairs Wash Hand Basins, Vitreous China padestal pattern white of size 550mm X 400mm including cutting for and pinning in ends of brackets or erecting stand including waste fittings, 32 mm bore PVC flush pipe with long screwed shucks and fly nuts and including PVC discharge pipe complete all as specified and directed.
141S&F in repairs Vitreous China Squatting Pan, \\"Orissa pattern\\", size 580x440mm white/ coloured with integral foot rests (excluding flushing cistern, flush pipe and waste pipe), including trap and connection to trap, and to flushing pipe, anti-syphonage pipe, etc.complete including all joints and making good to floors complete all as specified and directed.
142S&F in repairs Vitreous China Wash Down Water Closet Pan (pedestal pattern) complete, white/ coloured including seat and cover, trap, including connection to drain (or outgoing pipe), and to flushing pipe, anti-syphonage pipe, etc. etc.complete including all joints and making good to floors complete all as specified and directed.
143S&F in repairs 10 litres capacity low level PVC valveless syphonic action type flushing cistern with inlet ball valve, float and handle including brackets complete all as specified and directed.
144S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified complete all as specified and directed.
145S& F Syphon Kit including EPDM rubber washer for Monolithic or Cascade type of flush cistern for vitreous china 10 ltr capacity as fixed in repairs all as specified and directed.
146S&F in repairs sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mmcomplete all as specified and directed.
147S&F in repair Stainless steel plate rack of standard pattern & of size 750 x 650 x 250 mm.The thickness of stainless steel sheet shall be 1.00 mm & grade of sheet shall be 304 AISI including fixing to wall with 4 Nos 50mm screws & PVC rawl plugs complete all as specified and directed.
148S&F in repirs 600mmx450mm size of specified thickness looking mirror, bevelled edge of selected quality glass with aluminium frame made of channel around, mounted on 6mm thick commercial ply or AC building board, fitted to wooden plug with chromiumplated brass screws and cup washers complete all as specified and directed.
149S&F in repairs 8 to 10 mm thick bevelled edge mirror of selected quality glass edges to be polished and rounded , on fixed to wall with wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed.
150S&F in repairs factory made PVC body toilet cabinet (box type) 600x450mmx125mm size with mirror of selected quality glass having 5.5mm thickness and fixed to walls with screws and wooden/rawl plugs complete all as specified and directed.
151S&F in repairs 20mm dia brass chromium plated tubular towel rail 600mm long between flanges type \\"D\\", with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms)complete all as specified and as directed.
152S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
153S&F in repairs CP Soapdish Oval /square type complete all as specified and directed.
154S&F in repairs CP Toilet Paper Holder with Flap as fixed in repairs and all as specified and directed.
155S&F in repair to CP towel ring square complete all as specified and directed.
156S&F Toilet Seat cover plastic for water closet EWC with flat bottom and cover and mild steel chromium plated or aluminised hinging device all as specified.
157S&F in repairs 20mm dia mild steel PVC colour powder coated curtain rod with fancy type brackets including with all fittings as fixed in repairs and all as specified and directed.
158S&F in repairs 15mm bore chromium plated Wall Mixer for (Wall Mixer, Kitchen Mixer, WHB Mixer) for mixing hot and cold water screwed down for pipe connecting legs and wall flange complete all as per manufacturer's instruction, with 450mm long braded hoses and as directed.
159S&F in repairs 15mm bore chromium plated Wall mixer wall mounted for mixing hot and cold water screwed down for pipe with provision of overhead shower complete with 115 mm long bend pipe on upper side,connecting legs and wall flange for WHB,and kitchen sinks complete all as per manufacturer's instruction and as directed.
160Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting out in hard/dense soil complete all as specified and directed.
161Returning, filling, including spreading, levelling, watering and well ramming in layrs not exceeding 25cm in soft/loose soil complete all as specified and directed.
162Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
163Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable aftger laying complete all as specified and directed. Note: Punned thickness shall be measured.
164M&L sub class B bricks locally available of size 22 cm x 11.5 cm x 7.5 cm laid dry width wise across the line of cable in trenches for protection of underground cable complete all as specified and directed.
165M&L for Supply and spreadinng coarse graded aggregate of nominal size 20mm in above outdoor LT sub stns complete all as specified and directed by Engr- in -Charge
166M&L in replacement of 40 mm bore GI tubing light grade ISI marked for protection of cable including necessary joint and taking down complete all as specified and directed.
167Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
168Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) complete all as specified and directed.
169M&L for point wiring with PVC insulated unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 1.5 Sqmm (nominal area) in and including 20mm dia non metallic rigid PVC conduit with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and new GI/MS/CI sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire cable of size 1.5 Sqmm unsheated stranded copper conductor with green PVC FRLSH insulation connected to common earth dolly complete all as specified and directed for the followings :- (a) One light/fan/Bell Point controlled by one single pole one way switch. Note:- Cutting chases for conduits and sunken boxes and making good to walls, floors etc, in case of recessed and concealed conduit wiring are included in item of taking down point wiring carefully. Switches, ceiling roses, pendants, regulators, sockets, bell push and bells, junction boxes shall be measured and paid for separately.
170(b) One socket outlet on the same board controlled by one single pole one way switch
171(c) One 5 amps socket outlet independent controlled by one single pole 5 Amp switch.
172M&L for point wiring with PVC insulated unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 2.5 Sqmm (nominal area) in and including non metallic rigid PVC conduit with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and existing mild steel pressed / cast iron sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire cable of size 2.5 Sqmm unsheated stranded copper conductor with green PVC FRLSH insulation connected to common earth dolly complete all as specified and directed for one 3/5 pin 15 Amps switch socket out let on the independent board controlled by one single pole one way switch. Note:- Cutting chases for conduits and sunken boxes and making good to walls, floors etc, in case of recessed and concealed conduit wiring are included in item of taking down point wiring carefully.
173M&L for point wiring with PVC insulated unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 1.5 Sqmm (nominal area) in Existing non metallic rigid PVC conduit with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and New modular GI sunken boxes of suitable size for mounting Modular switches / bell pushes / sockets, fan regulator etc covered with new cover plate with frmae and sheet top cover including continuous earth wire cable of size 1.5 Sqmm unsheated stranded copper conductor with green PVC FRLSH insulation connected to common earth dolly complete all as specified and directed for the followings :- (a) One light/fan/Bell Point controlled by one single pole one way switch. Note:- Cutting chases for conduits and making good to walls, floors etc, in case of recessed and concealed conduit wiring are included in item of taking down point wiring carefully. Switches, ceiling roses, pendants, regulators, sockets, bell push and bells junction boxes shall be measured and paid for separately.
174ditto all as per item 166 above but for One 5 amps socket outlet independent controlled by one single pole 5 Amp switch.
175M&L for point wiring with PVC insulated unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 2.5 Sqmm (nominal area) in and including non metallic rigid PVC conduit with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and GI sunken boxes of suitable size for mounting Modular switches / bell pushes / sockets, GI flush boxes, fan regulator etc covered with new cover plate and frame and top cover including continuous earth wire cable of size 2.5 Sqmm unsheated stranded copper conductor with green PVC FRLSH insulation connected to common earth dolly complete all as specified and directed for one 3/5 pin 15 Amps switch socket out let on the independent board controlled by one single pole one way switch. Note:- Cutting chases for conduits and sunken boxes and making good to walls, floors etc, in case of recessed and concealed conduit wiring are included in item of taking down point wiring carefully. Modular fittings switches, ceiling roses, pendants, regulators, bell push and bells, sockets, junction boxes, cover plates with frame , GI metal flush boxes shall be measured and paid for separately.
176S&Fin repairs new MS pressed steel/cast iron sunken boxes rectangular block in replacement of old rusted sunken box. The MS pressed steel/CI Box shall be galvanised or painted black with two coats of black bituminous paint or any other paint as indicated complete all as specified and directed. The MS pressed steel/cast iron sunken boxes should be suitable for mounting of normal /modular switches, sockets, fan regulator etc and the item rate quoted also including making good the disturbed surfaces to match with the existing surface. The new MS pressed steel / cast iron sunken boxes should be following sizes with suitable thickness as per IS code.(a) 8\\" x 10\\" and suitable for main switch board.
177ditto all as per item No 169 above but of size 7\\" x 4\\" and suitable for 15 Amp Independent board.
178ditto all as per item No 169 above but of size 4\\" x 4\\" and suitable for 05 Amp Independent board.
179S&F in repairs 3mm thick bakelite sheet hylam of white top fixed with cup washers, machine screws on new / existing MS shuken box including removing existing switch / switch socket / bell push etc and refixing the only servicable switches/socket by making slots on new sheet complete all as specified and directed.(a) Min approx size 9\\" x 11\\" and suitable for main switch board.
180ditto all as per item No 172 but of Min size 8\\" x 5\\" and suitable for 15 Amp Independent board.
181ditto all as per item No 172 but of Min size 5\\" x 5\\" and suitable for 05 Amp Independent board.
182S&F Modular Switch, one way, 6A, module complete all as specified and directed.
183S&F Modular Switch, one way, 16A, module complete all as specified and directed.
184S&F Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed.
185S&F Modular Socket, 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
186S&F Modular white cover plate with frame, 1 module complete all as specified and directed.
187S&F Modular white cover plate with frame, 2 module complete all as specified and directed.
188S&F Modular white cover plate with frame, 3 module complete all as specified and directed.
189S&F Modular white cover plate with frame, 4 module complete all as specified and directed.
190S&F Modular white cover plate with frame, 6 module complete all as specified and directed.
191S&F Modular white cover plate with frame, 8 module complete all as specified and directed.
192S&F Modular Metal Flush Box, 1/2 module complete all as specified and directed.
193S&F Modular Metal Flush Box, 3 module complete all as specified and directed.
194S&F Modular Metal Flush Box, 4 module complete all as specified and directed.
195S&F Modular Metal Flush Box, 6 module complete all as specified and directed.
196S&F Modular Metal Flush Box, 8 module complete all as specified and directed.
197S&F Modular Bell Push 6A, I module complete all as specified and directed.
198S&F Modular step type regulator,120 W - 2 module complete all as specified and directed.
199S&F 5/6 Amp Switch piano flush type single pole one way ISI Marked complete all as specified and directed.
200S&F 15/16 Amp Switch piano flush type single pole one way ISI Marked complete all as specified and directed.
201S&F 5/6 Amp Socket outlet 2 in1, 3 pin flush type ISI marked complete all as specified and directed.
202S&F 15/16 Amp Socket outlet 2 in 1, 3 pin flush type ISI marked complete all as specified and directed.
203Fix only old serviceable 5/6 Amp Switch piano flush type single pole one way ISI Marked, retrieved after taking down fittings complete all as specified and directed.
204Fix only old serviceable 15/16 Amp Switch piano flush type single pole one way ISI Marked, retrieved after taking down fittings complete all as specified and directed.
205Fix only old serviceable 5/6 Amp Socket outlet 2 in1, 3 pin flush type ISI marked, retrieved after taking down fittings complete all as specified and directed.
206Fix only old serviceable 15/16 Amp Socket outlet 2 in 1, 3 pin flush type ISI marked, retrieved after taking down fittings complete all as specified and directed.
207S&F 5/6 Amp bell push flush type ISI marked complete all as specified and directed.
208S&F Ceiling Roses Ceiling rose, 3 phase/PVC/polycarbonate, isolated body omplete all as specified and directed.
209S&F Lamp holder PVC/Polycarbonate,isolated with back plate suitable for batten fittings ISI marked complete all as specified and directed. including 10W LED Bulb omplete all as specified and directed.
210S&F bell, Ding Dong AC. 230 Volts, single pole complete all as specified and directed.
211S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and directed.
212S&F in repairs exhaust fan blades louvers and setters for 200mm sweep plastic Exhaust Fan including taking down complete all as specified and directed.
213S&F in repairs exhaust fan blades, frame and louvers for 300mm sweep steel Exhaust Fan including taking down complete all as specified and directed.
214S&F in repairs fan motor for 300mm sweep steel Exhaust Fan, 230 Volts, 50 Hz, 1200RPM, copper winding, including taking down complete all as specified and directed.
215S&F in repairs fan motor for 200mm sweep plastic Exhaust Fan, 230 Volts, 50 Hz, 1200RPM, copper winding, including taking down complete all as specified and directed.
216S&F in repairs high quality PP blades of silent operation for Wall mounting fan 400mm sweep white colour, including taking down complete all as specified and directed.
217S&F in repairs corrosion resistant guards with strip for Wall mounting fan 400mm sweep white colour, including taking down complete all as specified and directed.
218S&F in repairs 400mm sweep Wall Mounting Fan, steel body, powerful copper winding motor, tilting control and oscillation knob, AC single Phase. 230V with blades and frame, including taking down, complete all as specified and directed.
219S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver threecore flexible copper conductor cases of suitable size complete all as specified and directed.
220S&F in repairs LED light fiting 1x 20 W, 230 Volts, AC, decortive box type with driver holder including LED tube light, connected up with three core flexible copper conductor PVC cable of suitable size, from ceiling rose, including taking down, complete all as specified and directed.
221S&F in repairs LED tube light fitting 1x9 W batten type fixed on wall/ ceiling etc. connected up with three core flexible copper conductor PVC cable of suitable size, from ceiling rose, including taking down, complete all as specified and directed.
222S&F in repairs decortive gate light/ garden light made up of high grade unbreakable polycarbonate material suitable for LED lamp B22-Moon 200 base suitable for mounting Pole dia 60mm max OD. Dimensions: width 200mm and height 227mm for moon 200 decorative gate light, including taking down, complete all as specified and directed.
223S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impactand corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and directed.
224S&F LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impactand corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and directed.
225S&F LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impactand corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and directed.
226S&F of high brightness IP 65 LED Strips of color Saffron, White & Green as per requirment with uniformity of light required to perfect outdoor application including thermal management in multiple optics complete with IP 65/66 protection complete complete all as specified and directed.
227S&F in replacement of automatic street light switch for automatic swithcing of street light/high mast light (timer switch) for Three Phase Load light. The Digital timer 24 hrs alongwith suitable power contractor as per IEC - 60947-4-1 , including incoming & outgoing MCBs,SMC Encloser and support terminal and enclosed in pole/wall mounted factory made PVC enclosure made out of rust proof , shock & termite proof and FRLS grade confirming to IP 54 of capacity 6 KW, Three phase, Contactor rating 32/TP and MCB rating 40Amp TPN, having Facility of manual operation. Makes:- HAVELLS (model - IHXTS03060 or Techno-commercially equivalent in approved makes)
228S&F in repairs sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired TPN DBs, 415 Volts 200Amps rated bus bar,Neutral link,Earth bar and Din rail, 4 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified.
229S&F in repairs sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired SPN DBs, 240 Volts 200 Amps rated bus bar,Neutral link,Earth bar and Din rail, 8 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified.
230S&F sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired SPN DBs, 240 Volts 200 Amps rated bus bar,Neutral link,Earth bar and Din rail, 4 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified.
231S&F Moulded Case Circuit Breaker (MCCB) Four Poles (FP) current carrying capacity 63Amp, 415 Volts, breaking capacity 25 KA with adjustable thermal and magnetic settings, complete all as specified and directed.
232S&F Miniature Circuit Breaker (MCB) Triple Pole and Neutral (TPN) current carrying capacity 63 Amp, 240V, breaking capacity 10 KA, type 'B' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
233S&F Miniature Circuit Breaker (MCB) Single Pole (SP) current carrying capacity 6 to 32 Amp, 240V, breaking capacity 10 KA, type 'B' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
234S&F Miniature Circuit Breaker (MCB) Single Pole and Neutral (SPN) current carrying capacity 40 Amp, 240V, breaking capacity 10 KA, type 'C' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
235S&F in repairs Single Pole two Pin and Earth Plug and Socket including one single pole MCB 20 Amp fixed in and including sheet Metal enclosures, including taking down, complete all as specified and directed.
236S&F in repairs submain wiring with two single core PVC insulated FRLSH cable with Copper conductor unsheathed cable of size 2.5Sqmm drawn through in and including 25mm dia non metallic rigid PVC conduit with all accessories including one 2.5Sqmm PVC insulated FRLSH cable with Copper conductor unsheathed cable single core for continuous earthing including taking down existing submain wiring and conduits etc complete all as specified and directed. ( Note : Two run of single core PVC insulated cable with Copper conductor unsheathed cable of size 2.5Sqmm and one run of 2.5Sqmm PVC insulated copper conductor single core (2x2.5Sqmm+1x2.5Sqmm earth wire) and one run of PVC conduit shall be measured as single run)
237S&F in repairs submain wiring with two single core PVC insulated FRLSH cable with Copper conductor unsheathed cable of size 6.0Sqmm drawn through in and including 25mm dia non metallic rigid PVC conduit with all accessories including one 6.0Sqmm PVC insulated FRLSH cable with Copper conductor unsheathed cable single core for continuous earthing including taking down existing submain wiring and conduits etc complete all as specified and directed. ( Note : Two run of single core PVC insulated cable with Copper conductor unsheathed cable of size 6.0Sqmm and one run of 6.0Sqmm PVC insulated copper conductor single core (2x6.0Sqmm+1x6.0Sqmm earth wire) and one run of PVC conduit shall be measured as single run)
238S&F in repairs Pin type porcelain, vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers & one galvanized iron nuts, 100 mm height, 65 mm dia for 1100 volts grade after dismantling & taking out old unserviceable and complete all as specified and directed.
239S&F in repairs cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape of size as dircted including applying of two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
240S&F in repairs MCCB adjustable thermal & fixed magnetic setting type 160 Amps, 4 pole of breaking capacity 25 to 36 KA, 415 Volt after and including taking down of unserviceable one complete all as specified and directed.
241S&F in repairs MCCB adjustable thermal & fixed magnetic setting type 400 Amps, 4 pole of breaking capacity 25 to 36 KA, 415 Volt after and including taking down of unserviceable one complete all as specified and directed.
242S&F in repairs MCCB adjustable thermal & fixed magnetic setting type 250 Amps, 4 pole of breaking capacity 25 to 36 KA, 415 Volt after and including taking down of unserviceable one complete all as specified and directed.
243S&F in repairs MCCB adjustable thermal & fixed magnetic setting type 100 Amps, 4 pole of breaking capacity 25 KA, 415 Volt after and including taking down of unserviceable one complete all as specified and directed.
244S&F in repairs MCCB in replacement of adjustable thermal & fixed magnetic setting type 125 Amps, 4 pole of breaking capacity 25 KA, 415 Volt after and including taking down of unserviceable one complete all as specified and directed.
245S&F in replacement Changeover Four pole 100 Amps capacity with SS Enclosure handle with door interlock kit fixed on wooden plank complete all as specified and directed.
246S&F in replacement of Changeover Four pole 63 Amps capacity with SS Enclosure handle with door interlock kit fixed on wooden plank complete all as specified and directed.
247S&F in repair 1100 volts grade heavy duty 16Sq mm Two single core cable flat or circular cable PVC insulated aluminium Stranded conductor, served with inner shething of PVC sheathed in service connections suspended by insulating hangers and porcelain beat not more than 1 metre apart including 4.0mm dia GI suspension wire, complete all as specified and directed.
248S&F in repair 1100 volts grade heavy duty 10Sq mm Two single core cable flat or circular cable PVC insulated aluminium Stranded conductor, served with inner shething of PVC sheathed in service connections suspended by insulating hangers and porcelain beat not more than 1 metre apart including 4.0mm dia GI suspension wire, complete all as specified and directed.
249S&F in repair 1100 volts grade heavy duty 6Sq mm Two single core cable flat or circular cable PVC insulated aluminium Stranded conductor, served with inner shething of PVC sheathed in service connections suspended by insulating hangers and porcelain beat not more than 1 metre apart including 4.0mm dia GI suspension wire, complete all as specified and directed.
250Supply, lay, test, joint and commission LT XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric powercable heavy duty with aluminium conductor of size cross sectional area 95Sqmm x 3.5 core, 1100 Volts grade (1.1 KV earthed system); laid in trenches/under floor/through ducts, on Hill / fixed on pole complete all as specified and directed. Note:- Excavation & Earth work, sand cushioning, cable protection cover, pipe shall be measured and paid separately under respective items of BoQ.
251Supply, lay, test, joint and commission LT XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric powercable heavy duty with aluminium conductor of size cross sectional area 50Sqmm x 3.5 core, 1100 Volts grade (1.1 KV earthed system); laid in trenches/under floor/through ducts, on Hill / fixed on pole complete all as specified and directed. Note:- Excavation & Earth work, sand cushioning, cable protection cover, pipe shall be measured and paid separately under respective items of BoQ.
252Supply, lay, test, joint and commission LT XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric powercable heavy duty with aluminium conductor of size cross sectional area 70Sqmm x 3.5 core, 1100 Volts grade (1.1 KV earthed system); laid in trenches/under floor/through ducts, on Hill / fixed on pole complete all as specified and directed. Note:- Excavation & Earth work, sand cushioning, cable protection cover, pipe shall be measured and paid separately under respective items of BoQ.
253Supply, lay, test, joint and commission LT XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric powercable heavy duty with aluminium conductor of size cross sectional area 16Sqmm x 4 core, 1100 Volts grade (1.1 KV earthed system); laid in trenches/under floor/through ducts, on Hill / fixed on pole complete all as specified and directed. Note:- Excavation & Earth work, sand cushioning, cable protection cover, pipe shall be measured and paid separately under respective items of BoQ.
254Supply, lay, test, joint and commission LT XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric powercable heavy duty with aluminium conductor of size cross sectional area 10Sqmm x 4 core, 1100 Volts grade (1.1 KV earthed system); laid in trenches/under floor/through ducts, on Hill / fixed on pole complete all as specified and directed. Note:- Excavation & Earth work, sand cushioning, cable protection cover, pipe shall be measured and paid separately under respective items of BoQ.
255M&L for meggering of cable including cable jointing kit of 1.1 KV (LT) grade for Heat-shrinkabIe straight through after disconnecting from LT Pole/panel as directed,and finding out fault including required earth work, cutting of cable and preparation for jointing of defective portion of cable complete with jointing material and accessories suitable for PVC/XLPE armored aluminum stranded conductor cable of size 50/70/95 sq mm 3.5 core complete all as specified and directed
256M&L for meggering of cable including cable jointing kit of 1.1 KV (LT) grade for Heat-shrinkabIe straight through after disconnecting from LT Pole/panel as directed,and finding out fault including required earth work, cutting of cable and preparation for jointing of defective portion of cable complete with jointing material and accessories suitable for PVC/XLPE armored aluminum stranded conductor cable of size 25/16/10 sq mm 4 core complete all as specified and directed
257M&L for repair of outdoor type LT Panel/Feeder pillar by repair of front & rear doors/ shutters, made out of MS/CRCA Sheet 3.15 mm thickness with necessary fabrication work like replacement of hinges, locking knob Bending, welding and painting with two coats of synthetic enamel paints over a coat of red oxide matching with existing panel colour as required at site complete all as specified and directed.
258S&F in replacement Ammeter of Minimum ranging upto 0-400 Amps alongwith Suitable CTs and Selector Switch as per existing item.
259Supply & Fixing Voltmeter of Minimum ranging upto 0-500 Volt alongwith Suitable PTs and Selector Switch as per existing specifications complete all as specified and directed.
260Supply, installation, testing and commissioning in replacement of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, suitable for AC, 3 phase 4 wire, 50 cycles, 415 Volts, Front & Rear openable double door with locking arrangement. as per IS-5039 amended upto date.The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.3m x 1.0 m x 0.45 m ) with Synthetic enemal Paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm , thimbles including cable entry glands , all as directed Base frame of the panel shall be made of angle iron of size 50 x50 x 6mm of upto 1/2 mtr hight from GL& 1/2 mtr for Below GL in PCC (1:3:6) type C-2 using 40 mm stone aggregates comprising of following:-(i) Panel having common aluminium bus bar of capacity 400 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCB's,including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size icluding removal of existing panel and make necessary connections as per existing.(ii) Incoming:-(a) MCCB Adjustable type thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 250 Amp 4 Pole ICU = ICS = 36 KA with overload variation 40-100% - 01 Nos.(Incoming)(iii) Outgoing:-(a) MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 160 Amp 4 Pole ICU = ICS = 16 KA with overload variation 40-100% - 02 Nos.(outgoing)(c) Same as above but of Capacity 100 Amps, 4 Pole 16 KA -01 Nos.(outgoing)(d) Same as above but of Capacity 63 Amps, 4 Pole 16 KA -01 Nos.(outgoing)(e) MCB SPN 32 Amps SPN 10 KA ,240 V (out going) -03 Nos(iv) Volt Meter 0 - 500 Volts digital type square shape flush mounted with selector switch - 1 Nos(v) Ammeter 0 - 400 Amps digital type square shape 96mm flush mounted with selector switch and CT's 400/5 A - 1 Nos.(vi) Indicator lamp RYB :01 Set. with CT Coil complete.
261Supply, installation, testing and commissioning in replacement of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, suitable for AC, 3 phase 4 wire, 50 cycles, 415 Volts, Front & Rear openable double door with locking arrangement. as per IS-5039 amended upto date The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.2m x 1.0 m x 0.45 m ) with Synthetic enemal Paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm , thimbles including cable entry glands , all as directed Base frame of the panel shall be made of angle iron of size 50 x50 x 6mm of upto 1/2 mtr hight from GL& 1/2 mtr for Below GL in PCC (1:3:6) type C-2 using 40 mm stone aggregates comprising of following:-(i) Panel having common aluminium bus bar of capacity 320 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCB's,including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size icluding removal of existing panel and make necessary connections as per existing.(ii) Incoming:-(a) MCCB Adjustable type thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 160 Amp 4 Pole ICU = ICS = 16 to 25 KA (iii) Outgoing:-(a) MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole ICU = ICS = 16 KA - 03 Nos.(outgoing)(b) MCB SPN 32 Amps SPN 10 KA ,240 V (out going) -04 Nos(iv) Volt Meter 0 - 500 Volts digital type square shape flush mounted with selector switch - 1 Nos(v) Ammeter 0 - 400 Amps digital type square shape 96mm flush mounted with selector switch and CT's 400/5 A - 1 Nos.(vi) Indicator lamp RYB :01 Set. with CT Coil complete.
262Supply, installation, testing and commissioning factory made, LT bus bar panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA sheet (Min size 0.4 m x 0.4 m x 0.35 m ) with Synthetic enemal Paint both side. as per IS-5039 amended upto date. Base frame of the panel shall be made of angle iron of size 50 x50 x 6mm of upto 1/2 mtr hight from GL& 1/2 mtr for Below GL in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregates). The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with and comprising of the following:- (i) Epoxy insulated common aluminium bus bar of capacity 200 Amp TPN each with Color Coding , including aluminium lugs to connect the cable.
263M&L in replacement of XLPE Insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 Volts, grade cross sectional area 95 Sqmm 3 Core including taking out old cable complete all as specified and directed. Note: Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item.
264S&F in replacement of cable jointing kit for 11000 Volt (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm 3 Core complete all as specified and directed.
265S&F in replacement of cable jointing kit for 11000 Volt (Earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.
266M&L for Earthing complete with Galvanised Iron earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at (Earth pit not less than 2.25m deep below ground level) a depth not less than 2.25m below normal ground level with top edge of earth plate at depth not less than 1.5m below normal ground level surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using 4mm dia galvanised earth wire by means of bolts, nuts, check nuts and washers of galvanized iron and protected by 15mm bore GI pipe light grade connected to main switch board or main control board and 20mm bore GI pipe light grade for watering and including funnel, wire mesh, 80mm thick pre-cast RCC (1:2:4) type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4Kg/Sqm in lieu of CI cover, PCC (1:2:4) type B-1 pit/chamber including all necessary excavation: and earth work, form work, disposal of surplus soil to a distance not exceeding 50m all as specified and al shown in Electrical Plate No.3 of MES Standard Schedule of Rates 2009 Part-I complete all as specified and directed.Note:- (i) The unit rate shall deemed to include for Test point, PCC pit, 4mm dia GI earth wire from top of the earth plate up to 7.5m above ground level. In case 15mm bore GIprotection pipe required is less than 7.5m, no price adjustment shall be made. (ii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junctions, elbow etc shall be deemed to be included in the unit rate.(iii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
267Disconnecting and taking down repairable LED type street light fitting of any type and capacity and make from existing 9 meter/11 meter pole for checking to find out the defects cleaning the glass and prefix cover, repair/replacement of spare parts including necessary wiring etc for making the fitting in serviceable condition and refixing in original position, testing etc complete all as specified and directed. Note: Spare parts will be measured and paid for separtely.
268Supply only LED driver 240Volt 50Hz for 40 to 48 watt LED fittings as per existing specifications complete all as specified and directed.
269Supply only LED driver 240Volt 50Hz for 60 to 90 watt LED fittings complete all as specified and directed.
270S&F in replacement of street light pole cable junction box IP-65 with metnic knockouts for cable entry and the box made out of thermal plastic material suitable for 16/25 sqmm underground cable including clamps bolts, nuts duly painted and MCB SP 6Amp etc complete all as specified & directed
271M&L painting to steel tubular pole with existing paint and including cross arms upto 11 m long (except planting depth /PCC coping) with including one coat aluminum paint including preparation of old painted surface & numbering of poles complete all as specified and directed.
272M&L painting of LT PCC pole upto 1.5 m height from PCC, of synthetic enamel paint over a coat of cement primer with black and white strips with aluminum paint on pole & numbering of poles complete all as specified and directed.
273S&F in replacement 40mm bore galvanised pipe light grade as in bracket for street light fitting bend to shape made out of GI pipe light grade 40mm bore upto 1.2m long etc complete with MS clamps duly painted with two coat of aluminum paint with nuts/bolts/washers for fixing arrangement to pole /wall complete all as specified and directed.
274Taking down of the UNSV/ defective transformers of capacity Upto 75 KVA (out door/Indoor type) from the existing site located in cantt area after disconnecting the in/out connection, transporting the transformers to workshop/factory for repairs,testing and transporting the same back after repairs and installing, hoisting of transformers on two/four pole structure at height not less than 3 metre, making all electric connections with HT/LT side jumpers and leads including earth connections etc and testing, complete all as specified and directed. Notes :-(i) Oil container for collecting old transformer oil will be arranged by the contractor(ii) The T&P such as chain pulley, crane for loading, unloading, transporting and for installing and hoisting shall also be arranged by the contractor.(iiI) Fixing LT coil DPC copper wire/strip of existing size(gauge) grade and in weight complete with insulating material for transformers complete all as specified. (iv)Replacement of all LT brass spindles complete , nuts, bolts, washers for transformers of Suitable Capacity complete all as specified.(v) Silica gel breathers assembly filled with silica gel (01 Nos) complete for transformers of capacity complete all as specified.
275M & L for opening the top of defective transformer of any make and capacity Upto 75 KVA removing gasket and lifting up the core assembly carefully to check the condition of transformer for repairs, dismantling core lamination to the extent required for taking out defective/ unserviceable coil for check after disconnecting all connections and re-assembling of core lamination to original position after positioning of existing serviceable coil alongwith new coils carefully to check the condition of transformer to ascertain the repairs/replacement of U/S parts including cleaning the tank, removing sludge, dirt cleaning the coils of limbs, re-fixing the core assembly and reassembling of transformer after repairs including zinc chromate paint inside , replacement of nuts bolts with washers thimbles etc and connections with aluminium strip and including welding, denting etc and testing the transformer at factory/workshop to the entire satisfaction of Engineer-in-Charge complete all as directed and as specified.(including the following )(a) Fixing LT coil DPC copper wire/strip and HV Side Coil of existing size(gauge) grade and in weight complete with insulating material for transformers complete all as specified. (b) Replacement of all LT brass spindles complete , nuts, bolts, washers for transformers of Suitable Capacity complete all as specified.(c) Silica gel breathers assembly filled with silica gel (01 Nos) complete for transformers of capacity complete all as specified.Note :- (a) The payments of new coils to be replaced shall be is included in item rate quoted by contractor.(b) Transformer Oil Dehydration and Topping up will be measure and paid Seperately after repair of Transformers
276S&F in replacement of LT brass spindles, nuts, bolts, washers for transformers of capacvity 75 KVA to 100 KVA complete all as specified and directed.
277S&F in replacement of LT bushing porcelain capacity 75 KVA to 100 KVA complete with gasket set complete all as specified and directed.
278S&F in replacement top cover gasket set of 8 mm thicknes ISI marked complete all as specified and directed.
279M&L opening, draining of oil ,stoppage of leakage ,change of gasket set complete HV/LV rods at site as required and refilling of transformer oil of capacity 75 KVA complete all as specified and directed.
280S&F in replacement of silica gel breathers assembly filled with silica gel complete for transformers of capacity Upto 100 KVA complete all as specified and directed.
281S&F in replacement of temperature gauge 0 to 300 degree centgrade for transformers of capacity upto 75 KVA complete all as specified and directed.
282Supply and pouring/ top up of new Transformer oil for Distribution Transformer Oil (as per IS 335) (EHV) of dielectric strenght min 45 KV in company sealed packed drum complete all as specified and directed. Make :- Volvoline , HPCL, MAK,Gulf ,Servo or equivalent in approved makes
283M&L for Cleaning sprinkled transformer oil, grease and all other foreign materials from external surfaces of transformers of capacity 75 KVA to 100 KVA and preparing the surface to receive paint and applying one coat of synthetic enamel paint (spray painting) including writing MES number and SM number with white paint over black base in letters not less than 10 cms in height complete all as specified and as directed. Note :- Painting shall be carried out at site.
284M&L removing old paint by paint removers and painting to existing outer & inner surcface of LT Control Panel of any size by using spray gun with one coat of red oxide and two coat of synthetic enamel paints as per colour code as mentioned below of, complete all as specified and directed.(i) LT Control Panel (Outer & Inner Surface) - Dark Grey Makes (of Paints): Burger/Asian/Nerolac of first quality or equivalent in approved makes
285Carrying out servicing/maint of 30 KVA DG set and cleaning including 'B' check as per manufacturers mannual through authorised dealer of DG set manufacturer of existing DG Make and testing of DG set complete all as specified and directed. Note:- All material/spares parts required for carrying out above maintenance/servicing shall be measured and paid separetely as 'Supply only' items as mentioned below and shall be of as per make of DG set and labour element required for replacing the spares parts including replacement of minor spare parts which are essential for carrying out servicing/maintenance of DG sets shall deemed to be included in the unit rate quoted by the tenderer
286Carrying out servicing/maint of 62.5 KVA DG set and cleaning including 'B' check as per manufacturers mannual through authorised dealer of DG set manufacturer of existing DG Make and testing of DG set complete all as specified and directed. Note:- All material/spares parts required for carrying out above maintenance/servicing shall be measured and paid separetely as 'Supply only' items as mentioned below and shall be of as per make of DG set and labour element required for replacing the spares parts including replacement of minor spare parts which are essential for carrying out servicing/maintenance of DG sets shall deemed to be included in the unit rate quoted by the tenderer
287Supply only lubrication oil SAE-40 ( 15 W- 40 grade) of make: Valvoline or HP Milcy Super 20W 40H, complete all as specified and directed. Makes: HP/Servo/Gulf or equivalent in approved makes
288Supply and filling of inhibitor corrosion (Coolant) suitable for radiators of 30 KVA capacity DG set complete all as specified and directed.
289Supply only Lub oil filter complete set complete all as specified and directed. Makes: Kirloskar/ Micco/Bosch or equivalent in approved makes
290Supply only Diesel filter complete set complete all as specified and directed. Makes: Kirloskar/ Micco/Bosch or equivalent in approved makes
291Supply only Air Filter as per sample complete all as specified and directed.
292Supply only Hose pipe & Flexible pipe complete set complete all as specified and directed.
293Supply only Fan belt for water pump complete all as specified and directed.
294Supply only Fan belt for alternator dynamo complete all as specified and directed.
295Supply only lead acid battery capacity of 90 AH, 12 volts for DG sets installed on pump house complete all as specified and directed.Makes:- Exide Express/Amron/Luminous or equivalent in approved makes
296S&Fing for replacement of Battery Charger for Lead acid & Tubular &VRLA-SMF for Battery upto 7 AH to 120 AH, 12 Volts, single Phase AC supply 230V, 50 Hz including all type indicators, showing charging complete all as specified and directed. Makes: Luminous/ Microtek or equivalent in approved makes
297Pump House/Electrical Installation Cleaning /Site clearence by cutting and removing shrubs, vegetation , grass , bush , weed , trees and saplings of any height up to the ground clearence.around water supply installation complete all as specified and directed. Notes:- i. The rates quoted includes stacking of useful material and dispose off rubbish / useless material up to a distance of 50 mtr out side the periphery of the installation.ii. Pump house area include the complete OHT area, pump house area and connected path way between pump house and OHT.
298M&L Cement concreted 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation of poles including necessary form work, fair finished to exposed surfaces without using extra cement wherever required complete all as specified and directed.
299M&L Cement concreted 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation and surrounding of stay assembly/feeder pillar/LT panel etc including necessary form work, fair finished surfaces without using extra cement complete all as specified and directed.
300M&L Cement concreted 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in coping of electric poles/struts/ etc including necessary form work, fair finished surfaces without using extra cement complete all as specified and directed.
301Supply and erect in replacement of prestressed concrete pole, 9.0metres long, 102mmx152mm at top and 102mm x 289mm at bottom, class 10, including replacement of unserciveable/broken PCC poles and painting of pole upto 1.5 m of height from coping level with alternative black and white strip of width not less than 0.3m and Writing pole No with with black or white colour by means of stencils complete all as specified and directed
302S&F in replacement Steel tubular swaged poles with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including taking down Old retrieved unserviceable complete all as specified and directed. Please Enable Macros to View BoQ information
303S&F in replacement Steel tubular swaged poles with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including taking down Old retrieved unserviceable complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57142379
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 16-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Comprehensive Maintenance Of Offrs Md Accn In Site 3 & 4 And Misc Repair To External Electric Supply In The Aor Of Age B/R-I Under Ge(West) Ferozepur Cantt
Basic Detail
Tender No CWE/FZR-70/2026-27
Bidding Type Tender
Location
City Firozepur
State Punjab
Key Dates
Publish Date 21 Aug 2026
Submission Date 16 Sep 2026
Open Date 23 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 1000
EMD 1.07 Lakhs
Exemption Available
Document List
21d041c5-45ff-4b3a-8852-8e18a22945a1.html
BOQ_880552.xls
Tender70.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 23 days
Sep 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 30 days

Tender Documents

Download All (ZIP) ↓
html

21d041c5-45ff-4b3a-8852-8e18a22945a1.html

xls

BOQ_880552.xls

pdf

Tender70.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders