Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #57142320

Tender For Repair / Maintenance Of Static Frequency Control Units Including Control Switches And Cables At installation Hansa Under Ge (Nw) Vasco. (Tender Id No. 2026_Mes_785604_1)

Issued by Statutory Bodies & Commissions/Committees · goa, Goa
Tender Value
45 Lakhs
Estimated cost
Bid Submission
11 Sep 2026
17 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance Of Static Frequency Control Units Including Control Switches And Cables At installation Hansa Under Ge (Nw) Vasco. (Tender Id No. 2026_Mes_785604_1)

BOQ

Name of Work:- REPAIR / MAINTENANCE OF STATIC FREQUENCY CONTROL UNITS INCLUDING CONTROL SWITCHES AND CABLES AT INS HANSA UNDER GE (NW) VASCO. (Tender ID No. 2026_MES_785604_1)
Sl. No. Item Description
1Supply and fixing in repairs PVC insulated and PVC sheathed flexible copper cable, 2 core x 10 sqmm, 1100 V grade, multi-stranded conductor, including laying, termination with suitable lugs/ferrules, connection, testing and commissioning, complete all as specified and as directed by Engineer-in-Charge.
2Supply and fixing in repairs PVC insulated and PVC sheathed flexible copper conductor cable, 2 core × 35 sqmm, 1100 V grade, complete with necessary glands, lugs, ferrules, saddles, terminations and connections, including laying, testing and commissioning, complete all as specified and as directed by Engineer-in-Charge.
3Supply and fixing in repairs PVC insulated and PVC sheathed flexible copper conductor cable, 3 core × 4 sqmm, 1100 V grade, complete with necessary glands, lugs, ferrules, saddles, terminations and connections, including laying, testing and commissioning, complete all as specified and as directed by Engineer-in-Charge.
4Supply and fixing in repairs PVC insulated and PVC sheathed flexible copper conductor cable, 3 core × 16 sqmm, 1100 V grade, complete with necessary glands, lugs, ferrules, saddles, terminations and connections, including laying, testing and commissioning, complete all as specified and as directed by Engineer-in-Charge.
5Supply and fixing in repairs PVC insulated and PVC sheathed flexible copper conductor cable, 4 core × 6 sqmm, 1100 V grade, complete with necessary glands, lugs, ferrules, saddles, terminations and connections, including laying, testing and commissioning, complete all as specified and as directed by Engineer-in-Charge.
6Supply and fixing in repairs PVC insulated and PVC sheathed flexible copper conductor cable, 4 core × 10 sqmm, 1100 V grade, complete with necessary glands, lugs, ferrules, saddles, terminations and connections, including laying, testing and commissioning, complete all as specified and as directed by Engineer-in-Charge.
7Supply and fixing in repairs PVC insulated and PVC sheathed flexible copper conductor cable, 4 core × 16 sqmm, 1100 V grade, complete with necessary glands, lugs, ferrules, saddles, terminations and connections, including laying, testing and commissioning, complete all as specified and as directed by Engineer-in-Charge.
8Supply and fixing in repairs PVC insulated and PVC sheathed flexible copper conductor cable, 4 core × 25 sqmm, 1100 V grade, complete with necessary glands, lugs, ferrules, saddles, terminations and connections, including laying, testing and commissioning, complete all as specified and as directed by Engineer-in-Charge.
9Supply and fixing in repairs PVC insulated and PVC sheathed flexible copper conductor cable, 4 core × 35 sqmm, 1100 V grade, complete with necessary glands, lugs, ferrules, saddles, terminations and connections, including laying, testing and commissioning, complete all as specified and as directed by Engineer-in-Charge.
10S & F perforated cable tray made out of GI Sheet of 14 SWG thickness including cable tray cover and as per required depth hot dipped in various width sizes including accessories like couplar plate, nut bolts, washers clamps, wall bracket up/down elbows, bends tees equal distances on wall/floor/through wall crossing and making good the surface, complete all as specified and as directed.
11M&L for fabrication, supply, installation, testing and commissioning of 230V AC, 50Hz Distribution Panel Board fabricated from CRCA sheet steel, complete with suitable capacity copper bus bars, neutral and earth bars, incoming 63A TPN MCB (01 No), outgoing 20A SP MCBs (16 Nos), AC voltmeter, AC ammeter with necessary CTs, phase indicating lamps, internal wiring, cable glands, lugs, ferrules, locking arrangement, painting/powder coating and all necessary accessories for proper functioning, complete in all respects and in replacement of old unsv as directed by Engineer-in-Charge.\\"
12M&L for fabrication, supply, installation, testing and commissioning of 208V AC, 400Hz Distribution Panel Board fabricated from CRCA sheet steel, complete with suitable capacity tinned copper bus bars, neutral and earth bars, incoming 100A TPN MCCB (01 No), outgoing 32A TP MCBs (16 Nos), AC voltmeter, AC ammeter with suitable CTs, phase indicating lamps, internal wiring with FRLS copper conductors, cable glands, lugs, ferrules, engraved labels, locking arrangement, powder-coated finish and all necessary accessories for proper operation, complete in all respects and in replacement of old unsv as directed by Engineer-in-Charge.
13Material & Labour for checking faults of SFCs for smooth functioning and working performance and all electrical connections by replacing the worn out electrical parts, including layout diagram of SFCs to be submitted by the contractor as per site provision complete all as directed by Engineer-in-Charge suitable for 20 KVA to 80 KVA suitable for 36V/115V/208V AC.Note:-(a) The cost of new Spares Parts/items will be measured and paid separately under relevant items.
14Material and labour to carry out full load test by providing necessary resistive loads and connected items for each SFC upto 90/110 KVA capacity for checking the performance complete all as specified and directed.
15Material and labour to carry out full load test by providing necessary resistive loads and connected items for each TRU upto 20 KW capacity for checking the performance complete all as specified and directed.Note for item No 14 & 15 :-(i) Necessary Load test certificate will be provided by the contractor for item ser No 2 & 3.(ii) Electricity will be provided as per all in cost rate by the department for necessary load testing.(iii) All items like cables, resistances loads will be arranged at contractor's end.
16Supply & fix in repairs inverter control card for SFC of capacity 36/115/208 Volts all as specified and directed.
17Supply & fix in repairs Charger control cards for SFC of capacity 36/115/208 Volts all as specified and directed.
18Supply & fix in repairs display control card for SFC of capacity 36/115/208 Volts all as specified and directed.
19Supply & fix in repairs IGBT suitable with existing current carrying capacity for SFC of capacity 36/115/208 Volts all as specified and directed.
20Supply & fix SCR rectifier module 3 phase for SFC of capacity 36/115/208 Volts all as specified and directed.
21Supply & fix in repairs DC Capacitor for SFC of capacity 36/115/208 Volts all as specified and directed.
22Supply & fix in repairs AC Capacitor for SFC of capacity 36/115/208 Volts and all as specified and directed.
23Supply & fix in repairs contactor 3 phase as per existing rating for SFC of capacity 36/115/208 Volts and all as specified and directed.
24Supply & fix Inverter choke for SFC of capacity 36/115/208 Volts and all as specified and directed.
25Supply & fix in repairs main power transformer suitable for 20 to 50 KVA for SFC of capacity 36/115/208 Volts and all as specified and directed.
26Supply & fix in repairs main power transformer suitable for 80 / 90 KVA for SFC of capacity 36 / 115 / 208 Volts and all as specified and directed.
27Taking down unserviceable any type of Main Switch, DB's including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc all as specified and as directed.
28S & F in repairs sheet metal enclosure single pole plug and socket with two pin and earth plug and socket plug socket with two pin with one DC MCB 20 Amps complete all as specified.(27 V DC +ve and -ve)
29S & F in repairs sheet metal enclosure TP with a three pin and earth plug and socket complete with one TP MCB 32 Amps complete all as specified.( 36 V 400 Hz 3 Ph)
30S & F in repairs sheet metal enclosure SPN with a two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified.(115 V 400 hz & 320 volt 50 hz)
31S & F in repairs sheet metal enclosure TPN with a five pin and earth plug and socket complete with one TPN MCB 32 Amps complete all as specified.(208 V 400 hz )
32M & L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thick by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engr-in-charge including demolish existing earth pit taking out old materials.
33Supply and fixing of copper strip of size 20 x 3.15mm with saddles and fixing screws for fixing in wall,ceiling and connected to earthing including bending,cutting, jointing wherever required including removing old unsv item complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57142320
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 11-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of Static Frequency Control Units Including Control Switches And Cables At installation Hansa Under Ge (Nw) Vasco. (Tender Id No. 2026_Mes_785604_1)
Basic Detail
Tender No 8262/E8
Bidding Type Tender
Location
City goa
State Goa
Key Dates
Publish Date 21 Aug 2026
Submission Date 11 Sep 2026
Open Date 18 Sep 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
8262tenderdocuments.pdf
959ca1ff-1339-4379-98d6-9384b81987b9.html
BOQ_880324.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Sep 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 24 days

Tender Documents

Download All (ZIP) ↓
pdf

8262tenderdocuments.pdf

html

959ca1ff-1339-4379-98d6-9384b81987b9.html

xls

BOQ_880324.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders