Tender For Construction Of Echs Polyclinic At Khadki Under Ge (Mh And Rh) Khadki
Tender Value
2.70 Crore
Estimated cost
Bid Submission
25 Sep 2026
32 days left
EMD
3.45 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Echs Polyclinic At Khadki Under Ge (Mh And Rh) Khadki
BOQ
| Sl. No. | Item Description |
| 1 | SCH 'A' PART-I To XIINote: This schedule is pre-priced by MES and the rate indicated under Col 5 signifies this fact only |
| 2 | Total amount of Sch 'A' Part-I (Building and Structures) |
| 3 | Total amount of Sch 'A' Part-II (Site Clearance, Excavation and Earthwork) |
| 4 | Total amount of Sch 'A' Part-III (Internal Water Supply) |
| 5 | Total amount of Sch 'A' Part-IV (Internal Electric Supply) |
| 6 | Total amount of Sch 'A' Part-V (Road, Paths & Culverts ) |
| 7 | Total amount of Sch 'A' Part-VI (Sewage Disposal) |
| 8 | Total amount of Sch 'A' Part-VII (Area Drainage) |
| 9 | Total amount of Sch 'A' Part-VIII (Compound wall, Fencing and Gate) |
| 10 | Total amount of Sch 'A' Part-IX (External Water Supply) |
| 11 | Total amount of Sch 'A' Part-X (External Electric Supply) |
| 12 | Total amount of Sch 'A' Part-XI (Cooling Appliances) |
| 13 | Total amount of Sch 'A' Part-XII (Fire Alarm System) |
| 14 | SCHEDULE 'A' PART-XIII (MISCELLANEOUS B/R AND E/M WORKS)Schedule 'A\\" Part-II to XII items, which are not Prepriced by MES are given here under, Bidders shall insert their rate in Column -7 only and the Estimated rate indicates as \\"Rs 0.00\\" under Col 5 are for that purpose only. |
| 15 | S&F for 15mm bore Push cock for urinal, Chromium plated, fancy type for iron pipe and fixed complete all as specified and as directed. |
| 16 | S&F health faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed. |
| 17 | S&F Two way bib cock, cast copper alloy, fancy type, chromium plated with wall flange quarter turn (Low-flow) 15/16mm dia complete all as specified and as directed. |
| 18 | S&F Piller tap/cock, fancy type, chromium plated, cast copper alloy with capstan head, screwed down high pressure with or without lettered \\"Hot or Cold\\" complete all as specified and as directed. |
| 19 | S&F 32 inches (80 cm ) dia. Polycarbonate convex mirror fibre moulded waterproof and weather proof with pole of 1.2 m long 40mm GI pipe and moulded bracket, embedded in PCC 1:2:4, type B1 incl, necessary earthwork etc, complete all as specified and directed. |
| 20 | M& L for cutting of road / foot path and making good with PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate ) of 150 mm complete all as specified and directed. |
| 21 | Supplied and fixed for 80mm bore Gun-metal, globe or Gate valves with iron wheel head, srewed both ends for iron pipe and fixed complete all as specified and directed. |
| 22 | S & F for sheet metal enclosure of SPN 6 way DB with 200 Amps rated bus bar 240 volts Double door with magnitic locking system complete all as specified and as directed |
| 23 | S&F 4 Pole MCCB 160 Amp, 50 Hz, 415 V with rupturing capacity 36 KA Capacity, ICS=100% ICU, confirm to IS/ IEC 60947-2 complete all as specified and directed |
| 24 | S&F 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 25 KA Capacity, ICS=100% ICU, confirm to IS/ IEC 60947-2 complete all as specified and directed |
| 25 | S&F 4 Pole MCB 63 Amp, C curve,50 Hz, 415 V with rupturing capacity 25 KA Capacity complete all as specified and directed |
| 26 | S&F 4 Pole RCBO 100 Amp, 50 Hz, 415 V with rupturing capacity 25 KA Capacity complete all as specified and directed |
| 27 | S&F 2 Pole MCB 32 Amp, C curve,50 Hz, 240 V with rupturing capacity 10 KA Capacity complete all as specified and directed |
| 28 | S&F 2 Pole RCBO 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA Capacity complete all as specified and directed |
| 29 | S&F 2 Pole MCB 16 Amp, C curve,50 Hz, 415 V with rupturing capacity 10 KA Capacity complete all as specified and directed |
| 30 | S&F 1 Pole MCB 10 Amp,C curve, 50 Hz, 415 V with rupturing capacity 10 KA Capacity complete all as specified and directed |
| 31 | S&F 1 Pole MCB 16 Amp,C curve,50 Hz, 415 V with rupturing capacity 10 KA Capacity complete all as specified and directed |
| 32 | S&F 1 Pole MCB 6 Amp, C curve,50 Hz, 415 V with rupturing capacity 10 KA Capacity complete all as specified and directed |
| 33 | Supply and fix refrigerator, double door electric driven (single phase), frost free of capacity 310 Litres, BEE 5 star rated, 220V -240V , 50 Hz, single phase complete all as specified and directed |
| 34 | Supply installation testing and commissioning Silent type Diesel Engine Generating set 415 volts 100 KVA or nearest higher size available, 3 phase 0.8 power factor, 50 Hz, 1500 RPM self exicited self regulated brushless AC generator installed including AMF panel, suitable for ambient condition at Pune (Maharastra) and confirming to condition under ISO 3046, IS 10002, BS 5514/5000 with capacity of 10% overloading for one hour in every twelve hour duration compliance with as per latest CPCB norms for emission limits in consonance with the enviroment (protection) thrid ammendment vide GSR 232(E) dt 31 Mar 2014 GSR 789(E) dt 11 Nov 2014 abd GSR 105(E) dt 17 Feb 2015 at ser no 05 issued by ministry of environment and forests GOI and noise level shall be 75 db(A) at 1 meter from the enclosure surface and including the following accessories :-(A) Alternator :-Synchronous alternator rated at 100 KVA suitable for continuous operation at 1500 RPM generating 415 volts at 0.8 PF (lag) suitable for 50 Hz, three phase, 4 wire system. The alternator shall be brushless, self excited & self regulated with an AVR .The alternator will be suitable for tropical climate and shall generally confirm to IS: 4722 : 2001 B5 :2613 The salient features of the alternators are :-(a) +-1% voltage regulation (max) in static conditions. (b) IP: 23 protections with class ‘H’ insulation. · (c) Permanent lubricating bearing. · (d) Permissible overload of 10% for one hour in 12 hours of operation. |
| 35 | (B) Diesel Engine: - Adquate capacity of Diesel engine water cooled to drive independently above alternator and after considering de-rating as per site conditons after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, 1500 RPM, as per relevant IS/BS complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under :- i) Fly wheel with housingii) Cooling system :- Moulded radiator with fan & belts.iii) Cooling Water pump : - Centrifugal type belt driven.iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia with MS pipe as per OEM medium grade including Turbo charger type Exhaust manifold Silencer - Residential type.v) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electric operated/ (as recommended by OEM) for 1% speed /frequecy regulation.Fuel filters. |
| 36 | vi) Lub oil System :- Lubricating oil filter , Lubricating oil pumpvii) Air Intake System :- Air intake Manifold, Air cleaner dry typeviii) Governer mechanical typeix) Starting System :- Electric Self starter with and including battary charging alternator 12 Volts DC.x) Batteries :- Batteries of maintenance free of capacity 12/24 V, 180 AH- 01 No (or as provided by OEM) complete with copper conductor multistranded leads of suitable length from self starter to the battary terminals complete with initial charge and initial fill of electrolyte all as specified.Start and stop push buttonIgnition key / SwitchRadiator with blower fan & first fill of coolant oilCorrosion inhibitor coolantDirect fuel injection system through governer mechanical type(xi) Noise level shall be 75 db(A) at 1 meter from the enclosure surface. |
| 37 | xii) Generator Monitoring Panel : - Comprising of all standard items as per standard manufacturing, microprocesser closed fully configurable control unit iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant temperature indicator, Battery volt display.xiii) Safety Controls : - Engine low lube oil pressure high water temperature and over speeding of engine.xiv) Coupling arrngement : - Flexible couplingxv) Accessories :- AVM Pads built- in or separtely mounted to manufactrer base frames.xvi) Base Frame : - Base frame is fabricated either in ISMC channel or in sheet metal. The base frame will be primer coated and painted. The base frame is rugged in construction and designed for mounting Diesel engine and alternator close coupled, with cross members mounted on AVM. The base frame shall have provision for mounting of acoustic enclosure & control panel on it. The base frame is having provision of lifting hook for convenient lifting of complete set, i.e. along with canopy, engine and alternator.xvii) MS/Steel flexible pipe line to and from the fuel tank to the DG Set.xviii) Battery Charger shall be provided as per manufacturer guidelines.xix) 1 No battery of 12 V in charged condition with its leads. |
| 38 | C) ACOUSTIC ENCLOSURE : Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet. The silent canopy shall be of nut bolt type construction. Critical processes of punching is done on CNC machines to maintain dimensional accuracy of holes within 0.1 mm. Powder coating is done after seven-tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE-RETARDANT foam as acoustic material & Rock wool for hot zone.Adequate hinged doors shall be provided to canopy, one door shall have glass window for control panel visibility.(i) Manufactured by OEM suitable for 100 KVA DG Set.(ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board.(iii) The generating set battery should be inside the enclosure.(iv) Fuel tank :-Daily service fuel tank of 8 hours of continuous operation, fabricated form 14/16 SWG sheet metal complete with drain, inlet and outlet connection and fuel gauge. |
| 39 | (v) Construction Details/specification are as follows : - (a) Outer body :- CRCA Sheet of 1.6mm thick. (b) Doors :- CRCA sheet of 1.6 mm thick. (c) Sound Insulation :- 100 mm thick rock wool (minimum density 64kg/Cum)/ fire resistance foam/puff as per OEM/ as per standard manufacturing to achieve desired decibel level.vi) The acoustic should be composite in construction and fully assembled integral unit.vii) The DG Set should be provided with external Emergency stop push button.viii) The enclosure should be suitably internally illuminated by LED Lamp fittings.ix) The noise level should be 75 dB at 1m under free field conditions as per the current CPCB norms.x) The acoustic enclosure parts shall be of powder coated after pre treatment process. The base frame should be painted with epoxy based black shade.Note :- (i) The complete DG Set shall be procured from authorised OEM of the manufacturer of engine. A certificate in this connection shall be submitted to the GE.(ii) Circulation system to achieve desired inside temperature of acoustic enclosure, if required shall be provided as per OEM recommendation. Please Enable Macros to View BoQ information |
| 40 | (v) Construction Details/specification are as follows : - (a) Outer body :- CRCA Sheet of 1.6mm thick. (b) Doors :- CRCA sheet of 1.6 mm thick. (c) Sound Insulation :- 100 mm thick rock wool (minimum density 64kg/Cum)/ fire resistance foam/puff as per OEM/ as per standard manufacturing to achieve desired decibel level.vi) The acoustic should be composite in construction and fully assembled integral unit.vii) The DG Set should be provided with external Emergency stop push button.viii) The enclosure should be suitably internally illuminated by LED Lamp fittings.ix) The noise level should be 75 dB at 1m under free field conditions as per the current CPCB norms.x) The acoustic enclosure parts shall be of powder coated after pre treatment process. The base frame should be painted with epoxy based black shade.Note :- (i) The complete DG Set shall be procured from authorised OEM of the manufacturer of engine. A certificate in this connection shall be submitted to the GE.(ii) Circulation system to achieve desired inside temperature of acoustic enclosure, if required shall be provided as per OEM recommendation. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 32 daysOct 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 39 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender