Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #57142309

Tender For Repair/ Replacement Of Lightening Conductor, Normal Earthing And Chemical Earthing Building Security, Avaiation Lights & Other Connected E/M Works Under Ge(Nb) Visakhaaptnam

Issued by Statutory Bodies & Commissions/Committees · Visakhapatanam, Andhra Pradesh
Tender Value
45 Lakhs
Estimated cost
Bid Submission
11 Sep 2026
19 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Visakhapatanam → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Replacement Of Lightening Conductor, Normal Earthing And Chemical Earthing Building Security, Avaiation Lights & Other Connected E/M Works Under Ge(Nb) Visakhaaptnam

BOQ

Name of Work:- REPAIR/ REPLACEMENT OF LIGHTENING CONDUCTOR, NORMAL EARTHING AND CHEMICAL EARTHING BUILDING SECURITY, AVAIATION LIGHTS & OTHER CONNECTED E/M WORKS UNDER GE(NB) VISAKHAAPTNAM
Sl. No. Item Description
1Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to 4.0mm GI wire (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 5 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 40 mm dia light grade for protection of earth electrode 20 mm dia for watering including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect all as shown in electrical plate No. 3 and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge. Note: (i) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost (ii) Main earthing lead upto and including 7.5 m or upto Test point shall be measured and paid under this item
2All as per item no 01 here-in-above galvanised earth strip of size 32x6 mm complete all as specified and as directed by the Engineer-in-Charge.
3M & L Earthing complete with copper earth plate electrode 600 mm x 600mm x 3.15 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with copper earth strip of size 20x3mm by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 40 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect all as shown in electrical plate No. 3 and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge. Note: (i) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost(ii) Main earthing lead upto and including 7.5 m or upto Test point shall be measured and paid under this item
4S & F in repairs earth continuity conductor or main earthing lead with galvenised iron strip of size 25x4 mm, fixed to wall on batten or recesses or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required complete all specification and directed.
5S & F in repairs earth continuity conductor or main earthing lead with galvenised iron strip of size 32x6 mm, fixed to wall on batten or recesses or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required complete all specification and directed.
6S & F in repairs earth continuity conductor or main earthing lead with aluminium strip of size 25x3 mm, fixed to wall on batten or recesses or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required complete all specification and directed.
7S & F in repairs earth continuity conductor or main earthing lead with copper strip of size 20x3 mm, fixed to wall on batten or recesses or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required complete all specification and directed.
8Re-fixing of old serviceable (serviceable strips as obtained from taking down) Copper/ GI/ Aluminium Strip of any size and type after straightening & dressing with and including saddles/ insulators with srews for fixing and making good disturbed strip complete all as specified and directed.
9S&F in repair saddle/insulator for earth strip with fixing arrangement in roof/ wall conductors of building/ hangar complete all as specified and directed.
10Brazing of broken/ loose connected copper strip of any size and type not exceeding 3.2 cm in length and not exceeding 6 mm in thickness complete all as specified and directed.
11M&L for brazing of broken/ loose connected aluminium strip of any size and type not exceeding 3.2 cm in length and not exceeding 6 mm in thickness including bringing of necessary machine at site complete all as specified and directed.
12M&L for welding of broken/ loose connected GI strip of any size and type not exceeding 3.2 cm in length and not exceeding 6 mm in thickness including bringing of necessary machine at site complete all as specified and directed. Please Enable Macros to View BoQ information
13M&L for welding of broken/ loose connected GI strip of any size and type not exceeding 3.2 cm in length and not exceeding 6 mm in thickness including bringing of necessary machine at site complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57142309
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 11-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Replacement Of Lightening Conductor, Normal Earthing And Chemical Earthing Building Security, Avaiation Lights & Other Connected E/M Works Under Ge(Nb) Visakhaaptnam
Basic Detail
Tender No C/8731/26-27/E8 TOKEN 64 OF 2026-27
Bidding Type Tender
Location
City Visakhapatanam
State Andhra Pradesh
Key Dates
Publish Date 21 Aug 2026
Submission Date 11 Sep 2026
Open Date 14 Sep 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
75a0b300-153c-4742-a883-ae44e8fc39dd.html
BOQ_880387.xls
Tendernotice_1.pdf
Tender_8731.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Sep 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

75a0b300-153c-4742-a883-ae44e8fc39dd.html

xls

BOQ_880387.xls

pdf

Tendernotice_1.pdf

pdf

Tender_8731.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders