Defence Statutory Bodies & Commissions/Committees Closing in 26 days TDR #57142296

Tender For Repair And Maintenance External Electrical Supply Items Of Air Force Component Held Under Ge Brichgunj

Issued by Statutory Bodies & Commissions/Committees · South Andamans, Andaman And Nicobar Islands
Tender Value
16 Lakhs
Estimated cost
Bid Submission
18 Sep 2026
26 days left
EMD
32000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
South Andamans → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance External Electrical Supply Items Of Air Force Component Held Under Ge Brichgunj

BOQ

Name of Work:- REPAIR AND MAINT EXTERNAL ELECTRICAL SUPPLY ITEMS OF AIR FORCE COMPONENT HELD UNDER GE BRICHGUNJ
Sl. No. Item Description
1Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in sofg / loose soil complete all as specified and as directed.
2Returning, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25cm soil / hard dense soil complete all as specified and as directed.
3Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point for soft/hard soil complete all as specified and as directed.
4Disconnecting and taking out old LT UG cable with aluminium conductor of any size/type from trenches/ walls/ poles/ pipes complete all as specified and as directed.
5Supply,laying,jointing,connecting,testing underground XLPE insulated,PVC seathed, armoured heavy duty electric LT cable,1100 volts grade with aluminium stranded conductor,10 sqmm 4core,laid in trenches/fixed to poles/drawn through pipes with suitable size cable glands,crimping type cable lugs,sockets etc.complete and taking down the existing cable complete all as specified and as directed.
6All as per Item Ser No. 05 but cable of size 10 Sqmm 2 Core complete all as specified and as directed.
7All as per Item Ser No. 05 but cable of size 16 Sqmm 4 Core complete all as specified and as directed.
8All as per Item Ser No. 05 but cable of size 70 Sqmm 3.5 Core complete all as specified and as directed.
9All as per Item Ser No. 05 but cable of size 150 Sqmm 3.5 Core complete all as specified and as directed.
10Supply & laying cable protection pipe of HDPE double wall corrugated (DWC) incl couplers,bends etc of size 50 mm OD and ID 38mm confirming to IS 14930 -II and ISI Marked all specified and directed.
11Supply & laying cable protection pipe of HDPE double wall corrugated (DWC) incl couplers,bends etc of size 110 mm OD and ID 95 mm confirming to IS 14930 -II and ISI Marked complete all specified and as directed.
12S&F in Replacement of LED street light fitting 70 watts,6000K energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening separate driver compartment with IP 66 protection and impact resistance of IK07 with 10 KV built in surge protection device, complete all as specified and as directed.
13S&F in Replacement of LED street light fitting 45 watts,3000K energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening separate driver compartment with IP 66 protection and impact resistance of IK07 with 10 KV built in surge protection device, complete all as specified and as directed.
14S&F in Replacement outdoor type FRP junction box of size 300x200x105mm, light weight suitable for pole mounting using clamps/bolts and nuts including MCB SP 2.5 Amps single pole incl necessary two way connector for loop in loop out cable connection complete all as specified and as directed.
15M&L for Cutting Bittumen Road Hard top at site as required for Laying of cables and making good of disturbed surface as per existing top with 20/40mm graded stone aggregate and bitumen layer etc after repair work complete all as specified and as directed.
16Supply & Laying of GI tubing light grade for encasing LT cables for mechanical protection, laide in trench /floor/under road or along the pole by means of M.S.F.I. clamps with necessary bolts nuts and washers etc of size 40 mm dia, complete all as specified and as directed.
17S & F in Replacement street light timer, three phase for 12 KW light load comprising of nature switch, contactor and MCB housed in a pole mountable enclosure complete all as specified and directed.
18S & F in Replacement street light timer, single phase for 8 KW light load comprising of nature switch, contactor and MCB housed in a pole mountable enclosure complete all as specified and directed.
19M&L for Servicing of split type air conditioner of 2.0/1.5/1 Ton capacity any make including, cleaning of air filter, condensing coil and cooling coil with CTC including refixing the unit complete in position, complete all as specified and as directed.
20Dismantling the following unservicable items from split type air conditioner of capacity 1/1.5/2.0 Ton of any make and any type and replacing the same with new one including testing and commissioning the same complete all as specified and as directed :- Compressor for 1.5 ton split type air conditioner
21All as per Item Ser No. 20 but Compressor for 2.0 ton split type air conditioner.
22All as per Item Ser No. 20 but Oudoor fan motor for 1/1.5 ton split type air conditioner.
23All as per Item Ser No. 20 but Oudoor fan motor for 2.0 ton split type air conditioner.
24All as per Item Ser No. 20 but Indoor Blower motor for 1/1.5 ton split type air conditioner.
25All as per Item Ser No. 20 but Indoor Blower motor for 2.0 ton split type air conditioner.
26All as per Item Ser No. 20 but Starting capacitor for 2.0 ton split type air conditioner, 100/120 mfd 230 volts.
27All as per Item Ser No. 20 but Starting capacitor for 1/1.5 ton split type air conditioner, 80/100 mfd 230 volts.
28All as per Item Ser No. 20 but Running capacitor for 1/1.5 ton split type air conditioner, 36 mfd 230 volts.
29All as per Item Ser No. 20 but Running capacitor for 2.0 ton split type air conditioner, 45 mfd 230 volts.
30All as per Item Ser No. 20 but PCB Electronic control board for 1.5/2.0 ton split type air conditioner.
31All as per Item Ser No. 20 but Hand Remote set for 1.5/2.0 ton split type air conditioner.
32All as per Item Ser No. 20 but Fan blade suitable size of 1.5/2.0 ton split type AC.
33S&F in Replacement copper condensor coil suitable for 1/1.5/2 T Split/window AC complete all as specified and as directed.
34S&F in Replacement copper evaporator coil (cooling ) suitable for 1/1.5/2 T Split/window AC complete all as specified and as directed.
35Disconnecting the electrical connections, making system pumping down, and removing the split type A/C of capacity 1.5 / 2 ton including copper pipe from the existing position and shifting the same to the new location, re-connecting the A/C after making suitable hole in the wall, providing necessary connections, including closing the hole with brick masonry and finishing surfaces to match with the existing complete all as specified and directed.
36M&L for Charging of refrigerant gas R-134 (a) in Refrigerator/watercooler of any make and type, including testing and commissioning the the equipment, complete all as specified and as directed.
37M&L for Charging of refrigerant gas R-22/ R-410/R-32 for Air conditioners of any make and type, including testing and commissioning the the equipment, complete all as specified and as directed.
38S&F in Replacement of Voltage stabilizer copper wound for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA, complete all as specified and as directed.
39S&F in Replacement of Voltage stabilizer copper wound for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and as directed.
40S&F in Replacement of Rotational moulded polyetheylene (HDPE) double layered ISI marked Water Tanks of 500 Ltr capacity Cylindrical & Vertical Type, ISI marked, hoisted and fixed in position with PVC cover including provision of 40mm / 25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed.
41All as per Item Ser Item No 18 here-in-before but of size 1000 ltrs capacity complete all as specified and as directed.
42All as per Item Ser Item No 18 here-in-before but but of size 2000 ltrs capacity complete all as specified and as directed.
43S&F in Repair PVC tank cover top for water storage tanks suitable for 500/1000/2000 ltrs capacity as per existing colour complete all as specified and as directed.
44S& F in Replacement steel water tubes medium grade (ISI marked) galvanised with all fittings and fixed to walls or laid on floor or in ceilings of size 20 mm bore pipe alongwith all fittings as per site reqirement including taking out of old pipelines complete all as specified and as directed. Make : Tata/Jindal/Bansal
45All as per item No 21 above but of size 25 mm dia complete all as specified and as directed.
46All as per item No 21 above but of size 40 mm dia complete all as specified and as directed.
47All as per item No 21 above but of size 50 mm dia complete all as specified and as directed.
48S&F in Replacement of GI tubing medium grade, 80mm bore ISI marked laid in floor / trenches etc fixing with all GI fittings as required at site including taking out of old pipe complete all as specified and as directet.
49S&F in Replacement of 20mm CPVC pipes SDR 13.5 & Plain CPVC SDR 13.5 grade with all types of fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc as required at site, fittings on walls/ceiling or laying in floors complete all as specified and as directed.
50All as per Item Ser Item No 26 here-in-before but of 25mm CPVC pipes complete all as specified and as directed.
51All as per Item Ser Item No 26 here-in-before but of 40 mm CPVC pipes complete all as specified and as directed.
52All as per Item Ser Item No 26 here-in-before but of 50 mm CPVC pipes complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57142296
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 16 Lakhs
LAST DATE 18-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance External Electrical Supply Items Of Air Force Component Held Under Ge Brichgunj
Basic Detail
Tender No 8808A
Bidding Type Tender
Location
City South Andamans
State Andaman And Nicobar Islands
Key Dates
Publish Date 21 Aug 2026
Submission Date 18 Sep 2026
Open Date 21 Sep 2026
Finance
Tender Value 16 Lakhs
Tender Fee 500
EMD 32000
Exemption Available
Document List
3add2e4e-b224-4579-89fb-010bb0844696.html
8808ATENDER.pdf
BOQ_880352.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 26 days
Sep 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 29 days

Tender Documents

Download All (ZIP) ↓
html

3add2e4e-b224-4579-89fb-010bb0844696.html

pdf

8808ATENDER.pdf

xls

BOQ_880352.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender