Tender For Repair/ Maintenance / Rewiring Of Internal Electrification, Fittings And Fixtures In Technical Area At Af Stn Suratgarh
Tender Value
45 Lakhs
Estimated cost
Bid Submission
14 Sep 2026
22 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ganganagar → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance / Rewiring Of Internal Electrification, Fittings And Fixtures In Technical Area At Af Stn Suratgarh
BOQ
| Sl. No. | Item Description |
| 1 | BOQ (REPAIR/ MAINT / REWIRING OF INTERNAL ELECTRIFICATION, FITTINGS AND FIXTURES IN TECHNICAL AREA AT AF STN SURATGARH) |
| 2 | Attending day to day complaints lodged in complaint register at AF Stn Suratgarh domestic area. The contractor will adhere time schedule for attending complaints as directed by Engr-in-Charge as follows: (a) Attending complaints for checking the existing electrical items for continuous electric supply including carrying out minor repairs etc as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc., Attending minor repairs such as testing, connections, fittings, nut, bolts screws etc to ceiling fan, exhaust fan (without taking down), shifting/refixing of LED light fittings, switch & socket, MCB etc, emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/ sub mains/ internal circuits of existing electrical system of main building/ block and . required to make the system in order/ functional with insulation tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and directed by Engineer-In-Charge (this will be included in unit rate).Notes:- (i) The complaint for \\"No Light\\" shall be attended immediately/ On Priority.(ii) Contractor should be submit the complaint register alongwirth complaint slip verfied from JE E/M or Engr-in -charge.(iiI) In case daily complaints are not attended,per complaint per day penalty recovery shall be charged Rs. 200/- |
| 3 | M&L for in replacement of sub-main wiring (concealed) with two single core 4 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonry including 25 mm dia non-metallic PVC conduit fixed in wall including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge. |
| 4 | M&L for in replacement of sub-main wiring (concealed) with two single core 6 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonry including 25 mm dia non-metallic PVC conduit fixed in wall including 6 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge. |
| 5 | M&L for in replacement of sub-main wiring (existing concealed PVC conduit) with two single core 4 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through existing PVC/steel conduit including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge. |
| 6 | M&L for in replacement of sub-main wiring (existing concealed PVC conduit) with two single core 6 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through existing PVC/steel conduit including 6 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge. |
| 7 | All as per srl item No 5 here in before but two single core 10 Sqmm |
| 8 | M&L as in replacement of sub-main wiring (Surface) with two single core 4 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn on and including 25 mm dia non-metallic PVC conduit fixed on wall including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge. Please Enable Macros to View BoQ information |
| 9 | M&L as in replacement of sub-main wiring (Surface) with two single core 4 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn on and including 25 mm dia non-metallic PVC conduit fixed on wall including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by Engr-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysSep 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender