Tender For Repair, Maintenance And Replacement Of Unserviceable Internal Wiring, Mcbs/Mccbs, Distribution Boards (Spn/Tpn Dbs), Ceiling Lights, Recess Lights, Decorative Lights And Flp Fittings, Isolators, Garage Actuators And Other Misc Items At Af
Tender Overview
Project Description
Tender for Repair, Maintenance And Replacement Of Unserviceable Internal Wiring, Mcbs/Mccbs, Distribution Boards (Spn/Tpn Dbs), Ceiling Lights, Recess Lights, Decorative Lights And Flp Fittings, Isolators, Garage Actuators And Other Misc Items At Af Stn Digaru.
BOQ
| Sl. No. | Item Description |
| 1 | Taking down/out copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for the same items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 2 | M&L for point wiring for light points / ceiling fan points / exhaust fan points/ call bell points controlled by one, one way switch with (FRLSH) PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including , PVC medium grade Concealed conduit not less than 20mm dia with MS sheet metal sunken box switch/Terminal box 1.2 mm thick and phenolic laminated sheet cover 3.0 mm thick and brass screws with cup washers all necessary wall cutting and making good disturbed surface complete all as specified and as directed. Note : Cutting chases & making good to disturbed surfaces to match with the adjoing suracfes shall be deemed to be included with the unit rate. |
| 3 | All as per item No 2.00 here-in-before but for one 6 amps socket out let point on the same board with other switches |
| 4 | All as per item No 2.00 here-in-before but for one 6 amps socket point on independent board. |
| 5 | All as per item No 2.00 here-in-before but for one socket outlet 15/16 amp on independent board with 2.5 Sq.mm cable and 2.5 Sq.mm earth wire. |
| 6 | M&L for Sub main wiring for power/circuit/for controlling for light point using FRLSH, PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 2.5 Sqmm, earth continuity conductor of size 2.5 Sqmm to be drawn through and including PVC conduit 20mm dia medium Grade Concealed in walls/roof/floors including taking down old unsv ones complete all as specified and as directed.(Note : (i) Two single core wires of 2.5 Sqmm and one wire of 2.5 Sqmm and one run of PVC conduit shall be measured as one unit). (ii) The unit rate included for making good the disturbed surface including finishes to match with the adjoining surfaces alongwith cutting chases) . |
| 7 | All as per srl item No 3.00 here-in-before, but 2 Single core of size 4 Sqmm and earth continuity conductor of size 4.00 Sqmm complete all as specified and as directed. |
| 8 | All as per srl item No 3.00 here-in-before, but 2 Single core of size 6 Sqmm and earth continuity conductor of size 6 Sqmm complete all as specified and as directed. |
| 9 | M&L for point wiring for light points / ceiling fan points / exhaust fan points/ call bell points controlled by one 5 / 6 Amps switch with 1.5 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including PVC casing caping (double lock pattern) and accessories on wall / ceiling surfaces etc. with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc including all other fixing accessories complete all as specified and directed. |
| 10 | All as per Sl. item No. 6.00 above but for one 5/6 Amps socket outlet point on the same board. |
| 11 | All as per Sl. item No. 6.00 above but for one 5/6 Amps socket point on independent board. |
| 12 | All as per item No 6.00 here-in-before but for one socket outlet 15/16 Amp on independent board with 2.5 Sq.mm cable and 2.5 Sq.mm earth wire. |
| 13 | M&L for Sub main wiring for power/circuit/for controlling light point using FRLSH, PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 2.5 Sqmm, earth continuity conductor of size 2.5 Sqmm to be drawn through and including PVC casing caping with including taking down old unsv ones complete all as specified and as directed.Note :- (i) Two single core wires of 2.5 Sqmm and one wire of 2.5 Sqmm and one run of PVC casing caping shall be measured as one unit). |
| 14 | All as per item No. 7.00 but 2 Single core of size 4 Sqmm and earth continuity conductor of size 4 Sqmm complete all as specified and as directed. |
| 15 | All as per item No. 7.00 but 2 Single core of size 6 Sqmm and earth continuity conductor of size 6 Sqmm complete all as specified and as directed. |
| 16 | M&L for point wiring for light points / ceiling fan points / exhaust fan points/ call bell points controlled by one 5 / 6 Amps switch with 1.5 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including , PVC medium grade conduit not less than 20/25mm dia and accessories on wall / ceiling surfaces etc. with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc including all other fixing accessories complete all as specified and directed. |
| 17 | All as per Sl. item No. 10.00 above but for one 5/6 Amps socket outlet point on the same board. |
| 18 | All as per Sl. item No. 10.00 above but for one 5/6 Amps socket point on independent board. |
| 19 | All as per item No 10.00 here-in-before but for one socket outlet 15/16 amp on independent board with 2.5 Sq.mm cable and 2.5 Sq.mm earth wire. |
| 20 | M&L for Sub main wiring for power/circuit/for controlling light point using FRLSH, PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 2.5 Sqmm, earth continuity conductor of size 2.5 Sqmm to be drawn through and including PVC medium grade conduit not less than 20/25mm dia with including taking down old unsv ones complete all as specified and as directed.Note :- (i) Two single core wires of 2.5 Sqmm and one wire of 2.5 Sqmm and one run of PVC conduit shall be measured as one unit). |
| 21 | All as per item No.11.00 but 2 Single core of size 4 Sqmm and earth continuity conductor of size 4 Sqmm complete all as specified and as directed. |
| 22 | All as per item No.11.00 but 2 Single core of size 6 Sqmm and earth continuity conductor of size 6 Sqmm complete all as specified and as directed. |
| 23 | S & F Switch piano 5 Amps single pole one way complete all as specified and as directed. |
| 24 | S & F Switch piano 5 Amps single pole one way, as per replacement for existing in place including taking down old unsv ones complete all as specified and as directed. |
| 25 | S & F Switch piano 5 Amps single pole bell push complete all as specified and as directed. |
| 26 | S & F Socket outlet 5 Amps 3 pin flush type complete all as specified and as directed. |
| 27 | S & F Socket outlet 5 Amps 3 pin flush type, as per replacement for existing in place including taking down old unsv ones complete all as specified and as directed. |
| 28 | S & F Switch Socket combination 5/6 Amps 3 pin flush type complete all as specified and as directed. |
| 29 | S & F Switch Socket combination 5/6 Amps 3 pin flush type, as per replacement for existing in place including taking down old unsv ones complete all as specified and as directed. |
| 30 | S & F Switch Socket combination 15/16 Amps 3 pin flush type complete all as specified and as directed. |
| 31 | S& F Switch Socket combination 15/16 Amps 3 pin flush type, as per replacement for existing in place including taking down old unsv ones complete all as specified and as directed. |
| 32 | S&F Stepped type fan regulator flush type complete all as specified. |
| 33 | S&F Ceiling rose, 3 phase /PVC/ polycarbonate isolated body complete all as specified and as directed. |
| 34 | S&F Bell buzzer, Ding Dong AC. 230 volts, single pole completed as directed. |
| 35 | S&F Lamp holder, PVC/ polycarbonate type with cord grip cap suitable for Batten/Angle fittings including taking down old unsv ones complete all as specified and as directed. |
| 36 | S&F LED bulb of Lamp wattage 15 Watts, with Cool Day White (6500K) B22 Base including taking down old unsv ones complete all as specified and directed. |
| 37 | S&F LED Tube light fitting (BRIGHT LINEA) of 20 watt (>125 Lm/W) with IP40 batten features a durable extruded aluminium body with high quality PC diffuser for illumination its slim integrated design ensures easy installation, while high efficiency options enhance energy efficiency natural white including taking down old unsv ones complete all as specified and as directed. |
| 38 | S & F LED Bulk Head fitting 10 watt with Injection molded polycarbonate housing IP65, IK08, 4.0kV inbuilt surge protection, PF ≥0.95, total System Lumens 120 Lm/W, 6500k CRI ≥ 80, Operating Voltage range 140 V - 270 V. including taking down old unsv ones complete all as specified and as directed. |
| 39 | S & F LED Building Secirity Light 30 watt made up of pressure die cast aluminiun housing with highly efficient LEDs and PC cover with integrated lens with Cool Day White (6500K) | IP66 Water Proof Outdoor Light | Lens Technology | Corded Electric | Aluminium Heat Sink | 4Kv Surge, 440V High Voltage Protection and bracket suitable for street light made out of GI pipe light grade of 25 mm bore & 0.75 mtr length (minimum), bend to shape including 2 pairs of MS flat iron clamps made out of 40 x 5 mm MS flat, nuts, bolts & washers etc, & painting the bracket with two coat of aluminium paint over a coat of red oxide primer including taking down old unsv ones complete all as specified and as directed. |
| 40 | S & F recessed Mounted/ceiling Round LED Downlighter 15 watt with ABS housing & PC Opal diffuser with integral Electronic LED Driver. IP20, PF ≥0.95, total System Lumens 1450 lm, 5700k CRI ≥ 80, Operating Voltage range 140 V - 270 V. including taking down old unsv ones complete all as specified and as directed. |
| 41 | S & F recessed Mounted/ceiling Round LED Downlighter 3 watt with Fame Spot LED spotlights offer high performance with precis beam control for commercial and retail spaces, designed for efficiency and longvity, they ensure consistent lighting quality with a sleek, modern aesthtic LED Driver. IP20, PF ≥0.95, 5700k CRI ≥ 80, Operating Voltage range 140 V - 270 V. including taking down old unsv ones complete all as specified and as directed. |
| 42 | S & F recessed Mounted/ceiling Round LED Downlighter 5/6 watt with Fame Spot LED spotlights offer high performance with precis beam control for commercial and retail spaces, designed for efficiency and longivity, they ensure consistent lighting quality with a sleek, modern aesthetic LED Driver. IP20, PF ≥0.95, 5700k CRI ≥ 80, Operating Voltage range 140 V - 270 V. including taking down old unsv ones complete all as specified and as directed. |
| 43 | S&F Recessed Mounted/Ceiling Square (2'x2') LED Panel light 36/40 watt with CRCA powder coated housing & high transmittance Opal diffuser for glare free with Electronic LED Driver. IP20, PF ≥0.95, System Lumens ≥100 lm/W, 5700k CRI ≥ 80, Operating Voltage range 140 V - 270 V including taking down old unsv ones complete all as specified and directed. |
| 44 | S&F VTPN DB, MCCB incomer, 4 ways double door,Metal door ,IP-43 IK 09 in 250A rated copper bus bars,earth bar,neutral links, no. of module DPX 160+12 complete incl. blanking plates as required & fixed flush to wall and making good the disturbed surfaces including taking down old unsv ones complete all as specified and as direct. |
| 45 | S&F VTPN DB, MCCB incomer, 8 ways double door,Metal door ,IP-43 IK 09 in 250A rated copper bus bars,earth bar,neutral links, no. of module DPX 160+24 complete incl. blanking plates as required & fixed flush to wall and making good the disturbed surfaces including taking down old unsv ones complete all as specified and as direct. |
| 46 | S&F MCCB 4P 125 Amps 415V, 50 Hz, breaking capacity 25 KA . Including dismantling taking down unsvericeable one. |
| 47 | S&F MCCB 4P 160 Amps 415V, 50 Hz ,breaking capacity 25 KA . Including dismantling taking down unsvericeable one. |
| 48 | S&F MCB TPN 100 Amps 240V ,50 Hz ,breaking capacity 10 KA,\\" C \\" series. Including dismantling and taking down unsvericeable one. |
| 49 | S&F MCB TP 63 Amps 240V ,50 Hz ,breaking capacity 10 KA,\\" C \\" series. Including dismantling and taking down unsvericeable one. |
| 50 | S&F MCB, SPN DB, 8 ways double door,Metal door, IP-43 IK 09 in 100A rated bus bars,earth bar, neutral links complete incl. blanking plates as required & fixed flush to wall and making good the disturbed surfaces complete all as specified and as directed including dismantling and taking down unsvericeable one. |
| 51 | S&F MCB, SPN DB, 12 ways double door,Metal door, IP-43 IK 09 in 100A rated bus bars,earth bar,neutral links complete incl. blanking plates as required & fixed flush to wall and making good the disturbed surfaces complete all as specified and as directed including dismantling taking down unsvericeable one. |
| 52 | S&F MCB SPN 40 Amps 240V ,50 Hz ,breaking capacity 10 KA,\\" C \\" series. Including dismantling and taking down unsvericeable one complete all as specified and as directed. |
| 53 | S&F MCB SP,10KA, 230V, C-curve, 6-32 amps incl dismantling taking down unsv one complete all as specified and as directed. |
| 54 | S&F Metal Plug Socket DB with sheet metal enclosures with two pin and earth plug and socket one double pole MCB 20 Amps,240V for AC/Geysor connenction with including taking down old unsv ones complete all as specified and as directed. |
| 55 | Taking down of old serviceable light fittings any type & any cap after the completion of repair/maint works are refixing the same complete all as specified and directed. |
| 56 | M & L for Sub main wiring for power/circuit and controlling light points with two single core multistranded FRLSH copper cable of 2 x 2.5 Sqmm & one solid copper cable of 1 x 2.5 Sqmm for continuous earth wire both PVC insulated & unsheathed drawn through and including stove enamelled steel conduit pipe of dia 20/25mm width complete with all accesories or to be fixed on wall respectively including white washing/colour washing/distembering to match with the disturbed surfaces including taking down old unsv ones complete all as specified and as directed. |
| 57 | S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole, 250 volt including taking down old unsv ones complete all as specified and as directed. |
| 58 | Supply & fixing LED light fittings 2 x 16 watt with flame proof fixture CMRI, certified recommended for gas/vapor of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heart resistant toughhened glass with LED tube light fixture drivers, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size including taking down old unsv ones complete all as specified and as directed. |
| 59 | Supply and fixing Flameproof cum waterproof LED Bulk Head light fitting of 40W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size including taking down old unsv ones complete all as specified and directed. |
| 60 | Supply and Fixing of Flameproof cum Waterproof LED Bulk Head light fitting of 15W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable of suitable size. including taking down old unsv ones complete all as specified and as directed. |
| 61 | M&L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized iron earth lead wire of 4 sqmm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (light grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion including dismantaling and taking down old unsv ones complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender