Tender For Restructuring Of Old 400Kv System Of Ph-Iii , Up Gradation Existing Scada System Of 400 Kv System Of Ph-Iv And Integration Of Upgraded Scada System With 400 Kv System Of Ph-Iii Stps Sarni.
Tender Value
24.47 Crore
Estimated cost
Bid Submission
23 Sep 2026
24 days left
EMD
24.47 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Betul → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Restructuring Of Old 400Kv System Of Ph-Iii , Up Gradation Existing Scada System Of 400 Kv System Of Ph-Iv And Integration Of Upgraded Scada System With 400 Kv System Of Ph-Iii Stps Sarni.
BOQ
| Sl. No. | Item Description |
| 1 | WORK PART |
| 2 | Construction of new single-storey ECR building within available approximate area of 25 m × 30 m (750 sq. m) for accommodating new Control & Relay Panels for 13 bays (09 existing bays + 04 future bays), complete with all associated amenities and facilities including store room, wash area, CCTV surveillance system, internal electrification, false ceiling, lighting fixtures, fans, centralized air conditioning system, fire detection & alarm system and all other related works, complying with applicable industrial standards and norms.(As per attached Part-B-Civil Tech specs & scope) |
| 3 | Construction of cable Trenches and Covers, Cable Trays etc. (including strengthening of existing cable trenches wherever required) for existing 09 Nos. bays. |
| 4 | Erection, Installation, Testing and Commissioning of all the supplied equipment for 09 Nos. bays including cable laying & all statutory approval / Clearances essentially required before & after installation / Commissioning and Charging shall be in the firm's scope. |
| 5 | Dismantling of C&R panels, cables and all associated equipment, (i.e. Battery Banks, chargers, etc.) installed in PH-III/IV,STPS Sarni. |
| 6 | Shifting, installation, testing & recommissioning of existing PLCC, ABT Meter, PMU, FOTE, RTU, RTCC, etc. and associated Panels for 09 Nos. bays. |
| 7 | Complete engineering and design of remodeling scheme for the SCADA based Control & Relay System of 400kV Switchyard, STPS Sarni & including design of all associated civil structures such as new ECR building and related works for 13 bays (09 existing bays + 04 future bays).&Erection, Installation, Testing and Commissioning of 400kV Main-I & Main-II Bus bar Protection Panels complete with Two Peripheral Units (PUs) for 15 bays each and Central Units (CUs) sized for minimum 24 bays&Work of Up gradation of existing installed SAS(including replacement of BCUs etc) of PH-IV For 06 Nos. Bays and its integration into the new SAS of STPS Sarni.&Erection, Installation, testing and commissioning of Twin Channel PLCC Panels complete with Line Matching Units (LMU), HF couplers, coaxial cables, tele-protection couplers, speech and data communication equipment and all associated accessories for both ends of 03 Nos. 400kV transmission lines. |
| 8 | Supply Part |
| 9 | Supply of Substation Automation System (SAS) for 9 Bays. |
| 10 | Supply of all required cables including control cables, power cables, fibre optic cables, coaxial cables and associated cable trays/accessories, CT's& CVT's Junction box etc. for all 09 bays. |
| 11 | Supply of complete AC & DC auxiliary power system comprising of 415V station auxiliary panel (ACDB, MLDB and associated equipment) lighting transformers etc. and Supply of 2x220V (each bank having 110 Nos. cell) and 2x48V DC batteries sets and their chargers, DCDB, as per prevailing grid norms suitable for 20 nos. bays. |
| 12 | Supply of Control & Relay panels for 01 No. 400KVSarni-Seoni line without Line Reactor. |
| 13 | Supply of Control & Relay panels for 01 No. 400KV Sarni-Koradi line without Line Reactor. |
| 14 | Supply of Control & Relay panels for 01 No. 400KVSarni-Itarsi line without Line Reactor. |
| 15 | Supply of Control & Relay panels for 01 No 400KVSarni-ISP line along with C&R Panels for Line Reactor. |
| 16 | Supply of 400kV Transformer Control & Protection panel for 315MVA ICT-1. |
| 17 | Supply of 400kV: Bus Reactor Control & Protection panel for Bus Reactors-1 & 2. |
| 18 | Supply of 400kV:Control & Protection panels of Bus Coupler. |
| 19 | Supply of 400kV:Control & Protection panels of Transfer breaker. |
| 20 | Supply of 400kV Main-I & Main-II Busbar Protection Panels complete with Two Peripheral Units (PUs) for 15 bays each and Central Units (CUs) sized for minimum 24 bays including existing, future and spare bay provisions. |
| 21 | Supply of items required for Up gradation of existing installed SAS(including replacement of BCUs etc) of PH-IV For 06 Nos. Bays and its integration into new SAS of STPS Sarni. |
| 22 | Supply of Twin Channel PLCC Panels complete with Line Matching Units (LMU), HF couplers, coaxial cables, tele-protection couplers, speech and data communication equipment and all associated accessories for both ends of 03 Nos. 400kV transmission lines.(One set consists of two numbers of Twin channel PLCC panel sets) |
| 23 | Mandatory Spares Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 24 daysSep 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 26 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender