Tender For Conversion Of Damaged Gi Pipes, Providing New Standby Motors For 3Hp, 5Hp,7.5 Hp For Various Plases And Drilling Of Bore Well With Mini Power Pump At Ward No: 1 Mattaiy Atty Kilakathikadu,Ward 2 Thoothanoor Amman Kovil,Ward 3 E-Mettukadu,W
Tender Overview
Project Description
Tender for Conversion Of Damaged Gi Pipes, Providing New Standby Motors For 3Hp, 5Hp,7.5 Hp For Various Plases And Drilling Of Bore Well With Mini Power Pump At Ward No: 1 Mattaiy Atty Kilakathikadu,Ward 2 Thoothanoor Amman Kovil,Ward 3 E-Mettukadu,Ward 10 Edanganasalai Ad Street,Ward 11 Madathur And Potharankadu,Ward 13 Pannangadu,Ward 14 Rasigoundanoor Ad Street,Ward 19 Nallan Atty,Ward 21 Papapatty In Edanganasalai Municipality.
BOQ
| Sl. No. | Item Description |
| 1 | Geophysical Investigation charges including preparation of Geophysical report as per TWAD Board type circular including all cost of transportation and handling charges etc.,complete |
| 2 | Drilling of 150mm(6\\") dia Vertical clear bores in Hard rock in any habitation any where in Salem District to any required depth as directed by the officers concerened including labour charges for inserting M.S/P.V.C Casing pipes to any reauired depth , assembilling in the drilled hole including welding joints if necessary grouting the casing pipes including conducting proper yield test at final depath (by providing 90 ' V' Notch fitted in a formed channel and the correct yield at the time of free flow in the channel while flushing the bore after completion of drilling process should be ascertained of and reported )including Bore cover transportation,crew and fuel charges for rigs and supporting Vechicles from one place to another etc., Complete and as directed by officers Concerned.Up to 0 to 150m |
| 3 | 151 to 180m |
| 4 | 181 to 210m |
| 5 | Supply and delivery of 160mm OD 6KSC PVC casing pipe for bore well including cost and conveyance of materials and labour charge for errection of casing pipe etc., Complete as per Standard Specification |
| 6 | Supply and delivery of wet type 3 HP (50 lpm x 250 m head) submersible pumpset with motor and confirming to IS 8034/2002 with ISI marking with D.O.L pannel board as per standard specification. The pump set should be supplied with 5M flat submersible motor etc.,complete. complying with std. specifications. |
| 7 | Supply and Run of 4x4 sq.mm(84/0.3) PVC insulated Sc unsheathed Cu.Conductor of 1100V grade in 25mm dia G.I pipe (\\"B\\"class) suitable bend at both ends with necessary angle iron up right and end supports for mains.TWAD-120) |
| 8 | Supplying and fixing in pisition of the following PVC and G.I specials best approved quality conforming to ISS and providing leak proof joint with PVC adhesive etc., complete complying with standard specification.63mm 6 KSC PVC Pipe |
| 9 | 63mm PVC Tee |
| 10 | 63mm PVC Bend |
| 11 | 63mm PVC Elbow |
| 12 | 63mm PVC MTA |
| 13 | 90mm PVC Endcap |
| 14 | 40mm GI Pipe |
| 15 | 40mm GI Bend |
| 16 | 40mm GI Ball Valve |
| 17 | 63mm 6 KSC PVC Pipe |
| 18 | Borewell pipe Clamp |
| 19 | Borewll Dummy |
| 20 | 40mm NRV |
| 21 | 40mm UPVC Column Pipe |
| 22 | 80mm G.M Gate Valve |
| 23 | 2000 liter HDPE Tank |
| 24 | Supply and run of 4 x6 sq.mm.(56Nos/0.3mm.Dia) PVC insulated single core unsheathed copper conductor cable of 1100 V on 7/20 G.I. bearer wire for service connection mains (SD 68) |
| 25 | Supply and Run of 4x4 sq.mm(84/0.3) PVC insulated Sc unsheathed Cu.Conductor of 1100V grade in 25mm dia G.I pipe (\\"B\\"class) suitable bend at both ends with necessary angle iron up right and end supports for mains.TWAD-120) |
| 26 | Supply and delivery of MS Kiosk of size 0.75m x 0.45m x 0.75m made up of MS angle of size 50mm x 50mmx 4mm alround covered with 16 gauge MS sheet and kiosk door made up of MS plates of size 25 mm x 3 mm including cutting, welding, grinding, locking arrangements etc., |
| 27 | Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable withproper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. |
| 28 | Earth work excavation for foundation and depositing on bank with in the initial lead of 10m and a lift of 2m in hard stiff clay, stiff block cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders etc. complete. complying with std. specifications.For HDPE Tank Pedestal |
| 29 | for pipe line-Bore Well to Tank |
| 30 | Cement Concrete of mix 1 : 4 : 8 (One Cement four sand eight aggregates) using 40mm gauge hard broken including cost conveyance of all materials to site including formwork and centering labour charges, transporting and placing in position including shoring, strutting, forming protective bunds, cofferdams bailing out of water labour for mixing compacting, finishing and curing, working at depths, tools and plants and incidental charges such as sheeting, shoring and bracing and their subsequent removal etc., complete as per standard specification. |
| 31 | Brick work in CM 1:5 (one cement & five sand) using using best quality of Fly ash Brick of size 23x11x7cm including finishing, curing, etc., complete complying with standard specification - 100CFT |
| 32 | Plastering in cement mortar 1:5 mix (one Cement and five sand) 12 mm thick etc., complete as per standard specification. |
| 33 | Painting two coats with ready mixed plastic emulsion paint of 1st class quality and of approved color over a priming coat including through scraping clean removal of dirt etc., complete and including necessary plaster of paris putty wherever required |
| 34 | Towards labour charges for laying of pipe line with specials to proper slopes and gradients including all cost and conveyance etc.,complete as per standard specification.63mmpvc pipe |
| 35 | Refillng with excavated earth after laying the pipes into the trenches including all labour charges etc., Complete as per Standard Specifications. |
| 36 | Removel of submersible pumpset and its accessories from borewell for attending repairs etc complete as per standard specfication |
| 37 | Re-erection of submersible pumpset and its accessories into the borewell after attending repairs etc completed as per standard specfication |
| 38 | Supply and fixing of 4.00sqmm Cable |
| 39 | Supply and Fixing of G I PIPES (MEDIUM) AS PER IS 1239/PART I/2004 (Additional erection to increse the depth of suction pipe and replacement of damaged suction pipe),32mm |
| 40 | Supply and delivery of clear water vertical wet type submersible pumpset suitable for 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 %,3HP 50x100 |
| 41 | 5HP 50x200 |
| 42 | 7.5Hp 50x250 |
| 43 | GST-18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender