Law and Justice Local Bodies Closing in 15 days TDR #57141086

Tender For Supplying And Installation Of Water Cooler Machine At 10 Nos. Various Places Under Uttar Dinajpur District The List Of The Site As Mentioned In Annexure-C

Issued by Local Bodies · Dinajpur Uttar, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Sep 2026
15 days left
EMD
69985
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dinajpur Uttar → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supplying And Installation Of Water Cooler Machine At 10 Nos. Various Places Under Uttar Dinajpur District The List Of The Site As Mentioned In Annexure-C

BOQ

Name of Work:- Supplying and installation of water cooler machine at 10 nos. various places under Uttar Dinajpur District the list of the site as mentioned in Annexure-C
Sl. No. Item Description
1Supplying high density polythene strainer of approved make with adapter conforming to I.S. specifications.(ii) 50 mm dia.
2Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).(A) PVC Pipes (Dia)50 mm
3Supply of G. I. pipes of TATA make including necessary sockets(i) 100 mm dia.(i) Medium quality
4(a) Original WorksLabour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore.(d) For depth upto 150 metre for 50 mm dia. tube well with top enlargement of 100 mm dia.(i) 50 mm dia. boring etc.
5(ii) 100 mm dia. boring etc. top enlargement
6Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets.(ii) 50 mm dia.
7Supplying, fitting and fixing heavy type bell mouth reducing socket.(i) 50 mm X 100 mm
8Supply and fitting fixing with 32 mm hosting of 1 HP 10 Stage Submersibel Pump with Electrical Control Pennel, 2 nos. stainless nipel with nut bolt, 1 no round flang for 100 mm dia pipe,M.S Clamp with necessary nut bolt nylon wire etc Complete.
9Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.40 AABBDP
10Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionSPHavells6-32 A
11Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.HavellsEnclosure (DHDPSNODRW04)2+4 way
12Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
13Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc.(b) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm)
14Supply & Fixing 3 Core 10 Sqm Aromowerd Cabel
15Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)(a) For Exposed WorkPVC Pipes32 mm
16Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)(a) For Exposed WorkPVC Pipes25 mm
17(Z) Compact Compact Ball Valve with SS Handle ForCPVC/ UPVC Fittings.(As per ASTM D 2467, Schedule 80)32mm
18(Z) Compact Compact Ball Valve with SS Handle ForCPVC/ UPVC Fittings.(As per ASTM D 2467, Schedule 80)25 mm
19Supplying P.V.C. water storage tank of approved quality with closed topwith lid (Black) - Multilayer(b) 1000 litre capacity
20Labour for hoisting plastic water storage tank.(i) Upto 1500 litre capacity.(a) Upto 1st story from G.L.
21Labour for punching hole in plastic water storage tank upto 50 mm dia.
22Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length(a) 75 mm
23(ii) Plain Tee(a) 75 mm
24x) Bend 87.5º(a) 75 mm
25Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
26Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
27(I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety](a) 1:3:6 proportion
28Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth
29Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.
30© (i) With carried earth arranged by the contractor within a radius of 1 km. including cost of carried earth.
31Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety
32Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor/upto 4 m (i) Tor steel/Mild SteelI. SAIL/TATA /RINL
33Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (a) 25 mm to 30 mm thick wooden shuttering asper decision & direction of Engineer-In-Charge.
34(f) 25 mm to 30 mm shuttering without staging in foundation
35Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:4 cement mortar (b) 15 mm thick plaster
36Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.NOTE:Cement 0.152 cu.m per100 sq.m.
37Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials.
38Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement(i) 35 mm. thick
39Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed. (i) 16 mm dia bolt(b) 450 mm long
40(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
41(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With super gloss (hi-gloss) - (iii) Two coat (with any shade except white)
42M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete.The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete.Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof.ii) For other Structural works like galleries etc.
43Galvanised plain sheet works (excluding supporting framework) fitted and fixed with 6 mm. dia J or L hook-bolts and nuts, sheet-bolts, limpet and bitumen washers and putty with 150 mm. end lap & 50 mm minimum side lap complete.(b) In wall: with 0.63 mm. sheets.
44Supply, fitting fixing and installation of 1 No. 500 Litter Tank Capasity Stainless steel SS304 boy cold Aqua Purifier of 2000 Watt Power, Flow Rate 1.5 1 pm, 3 stage purification capacity 170-260 V AC, thermal Sorage Tank Insulation with PUF, Compressore : Emerson KCN 463, Dimension, 750X570X1350 mm, 2 Nos. Cold Water faucets and 2 no. Normal Water faucets total 3 nos. faucets, 12 month warranty, water pressure 0.4-2Kg/Sqm. including all incidental charges and transportation charges. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57141086
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 07-09-2026
Authority
Authority Name District Magistrate
Work Description Tender for Supplying And Installation Of Water Cooler Machine At 10 Nos. Various Places Under Uttar Dinajpur District The List Of The Site As Mentioned In Annexure-C
Basic Detail
Tender No 82/Dev_Planning
Bidding Type Tender
Location
City Dinajpur Uttar
State West Bengal
Key Dates
Publish Date 21 Aug 2026
Submission Date 07 Sep 2026
Open Date 09 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 69985
Exemption Not Available
Document List
2911-ii.pdf
55917f74-b18d-4a6e-ad03-34c6b992abcc.html
BOQ_5092884.xls
Tendernotice_1 (30).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Sep 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
pdf

2911-ii.pdf

html

55917f74-b18d-4a6e-ad03-34c6b992abcc.html

xls

BOQ_5092884.xls

pdf

Tendernotice_1 (30).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders