Tender For Construction Of 2Nd Floor, Truss And Allied Works For Girls Hostel Building For Gcw Nawakadal At Eidgah Srinagar (Phase 2Nd).(Adv. Cost Rs 164.62 Lacs) (Incl Cost Of Material+Gst)
Tender Value
1.64 Crore
Estimated cost
Bid Submission
02 Sep 2026
4 days left
EMD
3.29 Lakhs
Bank guarantee accepted
Document Fee
2600
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of 2Nd Floor, Truss And Allied Works For Girls Hostel Building For Gcw Nawakadal At Eidgah Srinagar (Phase 2Nd).(Adv. Cost Rs 164.62 Lacs) (Incl Cost Of Material+Gst)
BOQ
| Sl. No. | Item Description |
| 1 | Civil part |
| 2 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer- in - charge. Note: - Cement content considered in this item is @ 330 kg/ cum. Excess/ less cement used as per design mix is payable/ recoverable separately. All works upto plinth level |
| 3 | Centering and shuttering including strutting, propping etc. and removal of form for:Columns, pillars piers, abutments, posts and struts |
| 4 | Stairs, (excluding landings) except spiral staircases : |
| 5 | Lintels, beams, plinth beams, griders, bressumers and cantilevers |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access plateform |
| 7 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 8 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in :6.15.1 Cement mortar 1:3 ( 1 cement : 3 coarse sand) |
| 9 | Providing wood work in frames of doors, windows, clerestory windows andother frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): First class kail wood |
| 10 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge :First class kail wood |
| 11 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. First class kail wood |
| 12 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.First class kail wood |
| 13 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). |
| 14 | Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications:13.57.2 Painting wood work with deluxe multi surface paint of required shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.75litre/10sqm of approved brand and manufacture |
| 15 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 16 | Providing/Fixing of door window stard wire fittings A) MS Tower bolts ,ISI marked oxidised, black finish with necessary screws, complete jobi) 100 mm |
| 17 | 150mm |
| 18 | B) Handlesi) 125 mm |
| 19 | ii) 150 mm |
| 20 | C) L-drops (Link)i) 200 mm |
| 21 | 250mm |
| 22 | D)Air hook100mm |
| 23 | 15mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement : 4 fine sand) |
| 24 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) in fine sand |
| 25 | 6mm cement plaster to ceilings of mix 1:3 (1 cement : 3 fine sand) |
| 26 | Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 27 | Providing and laying Vitrified tiles in floor with different sizes(thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS:15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of tile 600x600mm |
| 28 | Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete.50mm thick with 20mm nominal size stone aggregate |
| 29 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In all colours, shades, except White, Ivory, Fume Red Brown |
| 30 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steelbolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be consideredexcluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 31 | Providing and fixing in position collapsible steel shutters with vertical channels 20×10 ×2mm and braced with flat iron diagonals 20 × 5mm size, with top and bottom rail of T iron 40 × 40 ×6 mm with 40mm dia steel pulleys,complete with bolts , nuts, locking arrangements stoppers, handles including applying a primer coat of approved steel primer |
| 32 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade 13.70.1 Two or more coats on new work |
| 33 | P/applying of lime surkhi with part of cement (1 part lime : 2 part Surkhi : 10% of Cement) on existing brick work with necessary grinding,cutting getting out motar as per specifications, including curing, scaffolding material involved for lime surkhi as per requirments or as directed by site incharge. |
| 34 | Distempering with oil bound washable distemper of approved brand andmanufacture to give an even shade on New work (two or more coats) overand including priming coat with water thinnable cement primer |
| 35 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing inposition and applying a priming coat of approved steel primer all complete incld carriage.welded |
| 36 | P/f of 16mm dia bolts for pipes (450 mm length and nuts) |
| 37 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.68.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 38 | Providing edge moulding to 18/16mm thick marble stone counters , vanities etc including machine polishing to edge to give high gloss finish etc.complete as per design approved by engineer in charge |
| 39 | Providing and fixing 3.5mm thick glass panes incld cost of beading ,nailsetc complete as per directions of Engineer Incharge at site complete. |
| 40 | Providing colored high ribsheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape, hips,ridges and valleys all incl. |
| 41 | Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil : |
| 42 | Providing and laying of hand packed soling stone consolidated rammed filling the voids compacting all complete carriage upto site of work all head loads complete job. |
| 43 | Providing and laying in position cement concrete mix (1:4:8) of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with: |
| 44 | Providing and laying in position specified grade of reinforced cement concrete includin curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 45 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 46 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering,finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size |
| 47 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 48 | Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns |
| 49 | Walls (any thickness) incl.attached pilasters,betresses,plinth and string cources etc. |
| 50 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in charge. The product performance shall carry guarantee for 10 years against any leakage. (inside tank)a) For vertical surface two coats @ 0.70 kg per sqm |
| 51 | b) For horizontal surface one coat @1.10 kg per sqm. |
| 52 | Providing and applying of Polyurethane waterproofing coating (out side tank)for hohizontal and vertical surfaces |
| 53 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 54 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven storey height made with 40 mm dia M.S. tube 1.5 m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffoldings for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding.NOTE:- To be used for maintenance work judicially necessary deduction for scaffolding in the existing item to be done( scaffolding to be provided from exterior of the building to facilitate safe access for labourers and materials to the upper floors,ensuring the protection of interior finishing works of already constructed G+1 building in phase I) |
| 55 | P/f of tarpulin across the perimeter of the building ,Complete job, ensuring the protection of finishing works of already constructed G+1 building in phase I |
| 56 | Engagement of labour for dismantelling of temporary canopy Incl brickwork,steel,cgi sheets etc complete job |
| 57 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.13.89.2 Two coats |
| 58 | Supply and filling good earth earth including breaking clodding,levelling, rolling with half tone roller each and every third layer not exceeding in 20cm in depth incl.watering compactionof top most layer with 8-10 tonne road roller incl. carriages for a lead of 20km.complete job as per EIC |
| 59 | P/L GSB granular sub base material having p.i not more than 6\\" spreading in layers not exceeding 150mm compacted thickness & consolidated with80-100KN road roller POMC ti achieve at least 98% of max dry density as per IS2720 to the required grade as per specification with CBR value not less than 20incl. all leads ,lifts and carriages taxes etc compl job |
| 60 | P/L ,75mm compacted thick WBM grade II with 63mm -45 mm size stone with 1302mm screening incl supplying ,spreading ,watering and compacting with road roller to the required grade and camber spreading of binding material carriages of materials comp. job ( 2 layer =150mm) |
| 61 | Plumbing |
| 62 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white vitreous china flushing cistern, including CP flush pipe, bend with fittings and CI brackets, 40mm flush bend overflow arrangements with specials of standard make and mosquito proof coupling of approved municipal design complete, with manually controlled device with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required of Standard Makes Including PP Seat Cover with hinges Fixing Accessories,Cistarn Fittings etc. |
| 63 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass Centre Hole Basin Mixer(01 Nos), 32 mm C.P. brass waste of standard pattern(01 Nos), Pedestal (01 Nos) including painting of fittings and brackets, cutting and making good the walls wherever required of Standard Makes. (Size 550x400mm). |
| 64 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 65 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm |
| 66 | Providing and fixing toilet paper holder with Flap made out of C.P Brass Makes of standard / approved make C.P Brass |
| 67 | Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms |
| 68 | Providing and fixing health faucet with hose pipe for european water closet complete in all respect of approved quality/ standard Makes to be certified by the Engineer incharge |
| 69 | P/Fjet spray of approved make &quality,incl all necessary fittings complete job in all respects,incl, cutting nd making good the walls,testing for leakage, &as per directions of EIC |
| 70 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face withconcealed fittings arrangements of approved quality and colour, weighing not less than 88 gms. |
| 71 | Providing and fixing brass bib cock of approved quality.19.9.1 15 mm nominal bore |
| 72 | Providing and fixing C.P. brass angle valve for basin mixer and geyser/cisterns points.Of approved / standard Makes to be certified by the Engineer incharge(15 mm nominal bore) |
| 73 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore |
| 74 | Providing and fixing C.P. brass Single Lever Basin Mixer with 450 mm braided connection pipe. (2 feet length) of approved / standard Makes to be certified by the Engineer incharge15 mm nominal bore. |
| 75 | Providing and fixing C.P. brass bottle trap for wash basin including CP waste fittings complete 32 mm dia complete in all respect of approved quality of approved / standard Makes to be certified by the Engineer incharge |
| 76 | Providing and fixing C.P. brass Wall Mixer with Provision of Over Head Shower with 115 mm long bend.of approved / standard Makes to be certified by the Engineer incharge. |
| 77 | Providing and fixing soil, waste and vent pipes :18.35.1 100 mm dia. |
| 78 | Providing and Fixing of Floor Traps 110 mm with double chrome plated Cover one Grated and one closed and all other fittings required.of approved / standard Makes to be certified by the Engineer incharge |
| 79 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore |
| 80 | Providing and fixing factory-made uPVC rain water gutter of approved make, 100 mm nominal size, conforming to relevant IS standards, complete with all necessary fittings such as gutter unions, stop ends, running outlets, angles, brackets/clamps at suitable spacing, screws, rawl plugs and sealing compound, properly fixed to fascia board or structural members, including cutting, fitting, testing and making good complete in all respects |
| 81 | Providing and fixing PP Based soil, waste and vent pipes (Silencio as per DIN4109) suitable to rubber ring joints, which includes bends, rubber ring, jointing, junctions, clean out plug , cowls, offsets, collar, M.S holder-bat clamps, access pieces, trap of self-cleansing design .etc. complete including jointing. For Under Ground Sewage System in the Existing Excavated Trench.of approved / standard Makes to be certified by the Engineer in charge 110 mm dia. PPSWR socketed pipe with rubber ring joints. |
| 82 | 160 mm dia. PP SWR socketed pipe with rubber ring joints. |
| 83 | Supply, Installation of PVC Gully Trap of Size 110 mm of approved / standard Makes to be certified by the Engineer incharge |
| 84 | Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 16 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. of approved/ standard Makes to be certified by the Engineer incharge 50 mm Diameter32 mm Diameter |
| 85 | 25 mm Diameter |
| 86 | Providing and fixing on wall 50 LTRS Electric Geyser with ABS Body of approved / standard Makes to be certified by the Engineer incharge |
| 87 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.19.3.2.2 20mm nominal outer dia pipes. |
| 88 | 19.3.2.3 25mm nominal outer dia pipes. |
| 89 | 19.3.2.4 32mm nominal outer dia pipes |
| 90 | Centrifugal monoset self priming pump 1.5KW/ 2HP (CROMPTON) |
| 91 | Pressure Pump with danfoss switch Kirloskar Brothers JALRAAJ-I ULTRA 1 HP |
| 92 | Anti Microbial 1000 liter triple layer virgin plastic (COMFORT ISI MARK) |
| 93 | a) Carriage of stone aggregate for an average lead of 25km |
| 94 | b) Carriage of sand for an avg. lead of 16km |
| 95 | c) Carriage of bricks for an avg. lead of 20km |
| 96 | Internal Electrification |
| 97 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable of Polycab / Finolex /Anchor / Salzer /RR Cables /Grandlays /APAR make to be laid in surface / recessed medium class PVC conduit (25 mm dia PVC Unbreakable conduits of Anchor /Finolex /Ravinder /Paraflex make including cutting of walls and refacing of walls to original position with cement concrete ,pop and painting of cutting portion inorder match to existing walls ), with 6 Amps modular switch, modular plate of Anti backteria series ( Anti bacteria series of ABB /L&T /Legrand /Simens make , ) , suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(P+N+E is to be provided sperately for normal and invertor points ) .The ob futher includes providing and fixing of Lighting Conceal deeps /Fan deeps Junction boxes of heavy guage sheet steel dully powder coated paint of standard make dully ISI Marked. Including C/o Conduits |
| 98 | Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor (Polycab Green/Havell Life guard/ Fenolex/ Salzer/RR/Apar make as desired by engineer incharge ) single core cable in surface / recessed medium class PVC conduit, 2way modular switch,Antibacterial series ( Legrand /ABB / Siemens make.) modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 99 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable of Polycab / Finolex /Anchor / Salzer /RR Cables /Grandlays /APAR/Havell make in surfacel recessed medium class PVC conduit (25 mm dia PVC Unbreakable conduits of Anchor /Finolex /Ravinder /Paraflex make including cutting of walls and refacing of walls to original position with cement concrete ,pop and painting of cutting portion inorder match to existing walls ) alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Complete job Including C/o Conduits |
| 100 | Wiring for Circuits / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface l recessed medium class PVC conduit as required. of Polycab / Finolex /Anchor / Salzer /RR Cables /Grandlays /APAR make.(25 mm dia PVC Unbreakable conduits upto 6 sq.mm and 32/38 mm dia conduits above 6 sq.mm wires of Anchor /Finolex /Ravinder /Paraflex make including cutting of walls and refacing of walls to original position with cement concrete ,pop and painting of cutting portion inorder match to existing walls ) Including C/o Conduits2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 101 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 102 | 2 X6 sq. mm + 1 X 6 sq. mm earth wire |
| 103 | ( e )4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 104 | (f) 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 105 | Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required |
| 106 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, Antibacterial series ( Legrand /ABB / Siemens make.)connections etc. as required. |
| 107 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,modular plate, suitable GI box , connections etc. as required. Modular Switch & Socket:- Antibacterial series ( Legrand /ABB / Siemens make.) |
| 108 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- Antibacterial series ( Legrand /ABB / Siemens make.) |
| 109 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.Antibacterial series ( Legrand /ABB / Siemens make.) |
| 110 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.Antibacterial series ( Legrand /ABB / Siemens make.) |
| 111 | Supplying and fixing of following sizes of medium class PVC conduit( Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, with cement plaster, wall putty , paint, complete25 mm |
| 112 | 40 mm |
| 113 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).(legrand / Schinider/ L&T ./ABB/equivalent standard make as directed by engineer incharge.)8 way (4 + 24), Double door |
| 114 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(legrand / Schinider/ L&T ./ABB/equivalent standard make as directed by engineer incharge.)Single Pole |
| 115 | Single pole and neutral |
| 116 | Triple pole |
| 117 | Supplying and fixing 40 A to 63 A rating, 240/415 V, 10 kA, \\"C\\"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(legrand / Schinider/ L&T ./ABB/equivalent standard make as directed by engineer incharge.)Single pole and neutral |
| 118 | Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required. |
| 119 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 110 < 135 lm/Watt )Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc.as required with Minimum 5 year OEM warranty. System lumen efficacy ≥110and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim ), Philips/ Wipro/ Regent/Endo/LT make / sample to be approved before installation.. 15 watt |
| 120 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy>135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with inimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).), Philips/ Wipro/ Regent/Endo/LT make / sample to be approved before installation.. the job includes suitable bracket for its installation on the wall ( Complete job)70 watt |
| 121 | Supply installation testing and commissioning of Ceiling Fan 3 Star Rated with Voltage Range 90 V to 300 V,Min. Air Delivery 212 CMM,Service Value 5.3 Cu.m/min/watt,Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required. ), USHA/ Crompton /Orient make / Helonix /sample to be approved before installation..1200 MM |
| 122 | Supply,Installation,Testing and Commissioning 486 Cu.m/Hr. AC 220-240 Volts, 50 Hz exhaust fan made out of Metal Body with inbuilt thermo cutoff Protection and Noise Level not exceeding 37 dB of Following Sizes including connection etc. complete as required .), USHA/ Crompton /ORIENT/Helonix make / sample to be approved before installation.. 200-250 mm |
| 123 | LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker shouldbe below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).),Philips/ Wipro/ Regent/Endo/LT make / sample to be approved before installation.. 40 watt |
| 124 | Supply, installation, mechanical erection, testing and commissioning of three phase 20 KVA diesel generator set KIRLOSKAR/Cummins/Mahindra /ASHOKA LEYLAND (CSH) make , IP 23, H-Class, turbo charged developing required BHP 1500 RPM under NTP with 10 % overloading factor, with microprocessor based digital display genset engine controller for monitoring, metering, protection, control system,residential exhaust Siliencer, with batteries,including required capacity of AMF Panel inbuilt including first fuel fill etc. conforming to latest Govt. Emission norms CPCB-4, ( Complete job). |
| 125 | Carrying out foundation of PCC type, cement concrete to be carried in 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)in foundation of DG set etc including form work etc as required the job also includes supply and carriage etc of the requsite material upto the site. |
| 126 | Supply of advance maintenance free Chemical Gel Earthing of Dual Pipe Technology (GI) of 3 mtrs long 80 mm dia of outer shell (MS) with the 50 mm dia of inner shell (MS) of 80-100 microns galvanized CHEMRODE filled with highly conducting metallic compounds with the permenant sealings at both the ends with the lead terminal of 50x10mm size at the top. The electrode shall be duly tested and certified by CPRI (Central Power Research Institute), Govt of India for a peak short circuit withstanding capacity of 60 KA. including Supply/ fixing of environment friendly rust proof heavy duty weather proof polyplastic earth pit chamber. |
| 127 | Supplying and laying 25 mm x 5 mm G.I. strip at 0.50m. below ground level as strip earth electrode, including soldering etc. as required. |
| 128 | supply, laying underground, testing and commissioning of PVC alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size. c)50 sq.mm 3.5 core Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysSep 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender