Housing Urban and Rular Development Government Departments Closing in 10 days TDR #57140248

Tender For B.O.Q For Construction Of Building Less Primary School Lassipora Habber Budgam B.W.O Electric Work

Issued by Government Departments · Budgam, Jammu and Kashmir
Tender Value
3.33 Lakhs
Estimated cost
Bid Submission
09 Sep 2026
10 days left
EMD
6600
Bank guarantee accepted
Document Fee
200
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Budgam → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for B.O.Q For Construction Of Building Less Primary School Lassipora Habber Budgam B.W.O Electric Work

BOQ

Name of Work:- B.O.Q for Construction of Building Less Primary School Lassipora Habber Budgam B.W.O Electric work
Sl. No. Item Description
1Point wiring for switch controlled primary light /Fan /exhaust fan points with 3x1.5 sq mm (P+N+E) FRLSH PVC insulated 660/1100 volt grade flexible stranded copper conductor wires of Polycab/ Finolex/ Anchor / Apar/ RR Kabels make, to be laid in existing recessed or surface conduitng system and incl the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 6 amp control switch with modular cover plate of Schneider /ABB /L&T /Legrand /Simens make , complete as per specification and as required to be provided nd fitted on GI boxes .The Job includes providing and laying of circuit wiring with 3 x 1.5 Sq.mm PVC Insulated multistranded copper to be laid through pvc conduit from DB to first switch in sub circuit complete job .(Separate wiring for normal and invertor supply is to be provided and no extra circuit wiring shall be paid what so ever reason or length) Complete as required .The job further includes providing and fixing of lighting deep Junction Boxes /Fan Deep Boxes made of factory fabricated sheet steel (Heavy guage) dully powder coated to be installed in slab for holding of lighting fixtures /ceiling fans(including cost of conduits with allied accessories)
2Wiring for lightl power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface l recessed medium class PVC conduit (25 mm dia PVC Conduits including cutting of walls /floors with hydraulic cutters and refacing to original position by way of cement plastering /pop / paiting etc complete job ) including alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. of Polycab /Finolex /Anchor/ Apar /RR /Salzer make.
3Wiring for submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit (25 mm dia PVC Conduits including cutting of walls /floors with hydraulic cutters and refacing to original position by way of cement plastering /pop / paiting etc complete job ) as required. of Polycab / Finolex / Apar/ Anchor / RR Kabels /Salzer make.
42 X 2.5 sq. mm +1 X 2.5 sq. mm earth wire
52 X 6 sq. mm + 1 X 6 sq. mm earth wire
62 X 10 sq. mm + 1 X 6 sq. mm earth wire
7Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing of 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. ( Anti backteria series of Schneider /ABB /L&T /Legrand make , )
8Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing of 2 No's of 3 pin 5/6 A modular socket outlet and 2 No's of 5/6 A modular switch, connections etc. as required. ( Anti backteria series of Schneider /ABB /L&T /Legrand make)
9Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.( Anti backteria series of Schneider /ABB /L&T /Legrand / make)
10Supplying and fixing of 16 Amps Box type S-S Combine for invertor input and out put
11Supply and fixing of 16 Amps 3-Pin Top of SSK /Eq.make
12Supply, Installation, Testing and Commissioning of 1200 mm sweep , 3 nos. blades, 30 cm long down rod, , suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. of Usha /Helonix /Crompton / Orient make
13Supply, Installation testing and commissioning of 250 mm sweep Exhaust Fans of Usha / Crompton Greaves / Havel's incl making of necessary connections and making of necessary space in walls / Windows as per site.The Job includes providing and fixing of shutter of suitable size backlite hylum sheet for fixing of exhaust fan of Usha /havels /Crompton / Helonix make
14Supply, Installation, Testing and commissioning of 12 watt LED surface/recessed Down lighters having CRCA /Aluminium Body ,minimum lumens 100 lm/w ,the luminaries housing should be crca /aluminium and the luminary optics shall have a high efficiency with transmittance ,average life of 50000 hrs operating temperature -10 C to + 45 C of crompton / Wipro/ Helonix /Jaguar /philips make incl making of necessary Connections. ). The job further includes replacement warranty of fixture (if damaged /burnt out what so ever reason) for a period of one years reckoned from date of successful commissioning /handing over of site to intending department.
15Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) of Legrend / L&T / ABB /Simens /schinder
166 way (4 + 18), Double door
17Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required of legrand / ABB /Schneider /L&T /Simens make
18Supplying and fixing of 40 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections.of Legrand / ABB /Schneider /L&T /Simens make
19Supplying and fixing of 63 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections
20Supply/ installation/testing and commissioning of Wall / floor mounted compartmentalized , 415 volts TPN MCCB Main Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, duly painted with powder coating ( not less than 80 microns ) incl earth terminal with all necessary accessories as required for panel (IP 54) with internal wiring of panel .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices (1) Normal Incoming (1A) 125 Amp DP MCB (10KA) of Legrend /Schinder /Simens / ABB make = 1 no (1B) 200 Amp PN Aluminium Bus bar = 1 Set ( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 20 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc , and one set of CT's of ratio 125 A/5A ,CL 1.0 ,15VA .(1D) 1 Set of phase indication lamps (2) Generator Incomer 63 Amp F.P Change over switch of Havels./HPL /Standard make = 1 no100 Amp TPN Bus bar Al Strips = 1 Set 1 Set of phase indication lamps (4) Outgoing .63 Amps Double Pole MCB (10 KA) of Legrend /Schinder /Simens / ABB make = 3 No40 Amps Double Pole MCB (10 KA)of Legrend /Schinder /Simens / ABB make = 3 No The Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear's and Drawing's of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards ) & is to approved by Department not less than the rank of SDO before manufacturing of panel.
21Supply,Laying,Testing & Commissioning of 50 sq.mm 2- core armored Al Cable XLPE/ PVC Insulated and Steel sheathed of Havells/ Eq. make, including cost thimbles on input aswell as output sides dully crimped with hydraulic crimping tool incl making of necessary connections ,Including rolling of LT Colour coded types for main service line from LT pole
22Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoall coke and salt as required.The job includes providing and fixing of main hole PVC Chamber with its cover complete job
23Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57140248
AUTHORITY Government Departments
TENDER VALUE 3.33 Lakhs
LAST DATE 09-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for B.O.Q For Construction Of Building Less Primary School Lassipora Habber Budgam B.W.O Electric Work
Basic Detail
Tender No NIT No.135//2026-27 Dt/21/08/2026
Bidding Type Tender
Location
City Budgam
State Jammu and Kashmir
Key Dates
Publish Date 21 Aug 2026
Submission Date 09 Sep 2026
Open Date 10 Sep 2026
Finance
Tender Value 3.33 Lakhs
Tender Fee 200
EMD 6600
Exemption Not Available
Document List
45c6058a-6f48-41e7-b131-de69fa9b780e.html
BOQ_1075872.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Sep 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

45c6058a-6f48-41e7-b131-de69fa9b780e.html

xls

BOQ_1075872.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail