Water Resources and Irrigation Local Bodies Closing in 9 days TDR #57135404

Tender For Amrut-Augmentation Of Uwss To Nedumangad Muncipality-Upgradation Of Existing 13.75 Mld Water Treatment Plant At Perumala And Providing 3000 Fhtcs- Package 7-Supply And Erection Of Transformer And Other Related Works-Pipeline Work-Pipeline

Issued by Local Bodies · Thiruvananthapuram, Kerala
Tender Value
1.62 Crore
Estimated cost
Bid Submission
01 Sep 2026
9 days left
EMD
50000
Bank guarantee accepted
Document Fee
5515
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Amrut-Augmentation Of Uwss To Nedumangad Muncipality-Upgradation Of Existing 13.75 Mld Water Treatment Plant At Perumala And Providing 3000 Fhtcs- Package 7-Supply And Erection Of Transformer And Other Related Works-Pipeline Work-Pipeline Work

BOQ

Name of Work:- AMRUT-Augmentation of UWSS to Nedumangad Muncipality-Upgradation of Existing 13.75 MLD Water Treatment Plant at Perumala and Providing 3000 FHTCs- Package 7-Supply and Erection of Transformer and other related works-Pipeline Work-Pipeline Work
Sl. No. Item Description
1Construction of Electrical Substation and other allied works
2OD300787/2025-2026:H T CABLING - Supply of 3C 240 sq.mm (A2XFY/A2XWY) XLPE insulated, PVC sheathed, Armoured cable with conductors of best conductivity Aluminium conforming to IS: 7098/II/85, 11KV grade approved by the Engineer in charge
3OD300803/2025-2026:H T CABLING - Laying charges for 3C 240 sq.mm one number XLPE insulated, PVC sheathed,Armoured cable with conductors of best conductivity Aluminium conforming to IS: 7098/II/85, 11KV grade of following sizes direct in ground including excavation of trench of depth 1200 mm, providing protective covering with country burnt bricks laid breadth wise, sand cushioning, refilling the trench etc. as required and approved by the Engineer in charge /Consultant.
4OD300785/2025-2026:H T CABLING - Laying charges for 3C 240 sq.mm one number XLPE insulated, PVC sheathed, XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
5OD300796/2025-2026:HT Cable End termination - Supplying and making HT cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 185 sq. mm
6OD300818/2025-2026:CT/PT UNIT (INDOOR) - Supply, Testing,Installation and Commissioning of cast resin CT/PT unit (CT required rating , class 0.2S, 15VA; PT 11000 /110V, class 0.2, VA 100). Indoor cabinet , including 200A LBS , 12kv 3pole , 50ka is dust and vermin proof, IP-42, floor mounted, front operated, made out of 14/16 SWG thick CRCA sheet fully compartmentalized as per approved design and requirements, hinged doors , HT insulator bus bar, connection , lighting arrester provision for energy meter, and sealing option for all doors The rate includes testing of CT/PT unit at TMR Division of KSEB, obtaining test certificate and remitting of necessary fees.
7OD300804/2025-2026:TOD METER - Supply, Testing and Commissioning of HT TOD Meter including Test terminal block, 3p 4W, frontconnector, screw type. The rate includes testing of TOD Meter at TMR Division of KSEB, obtaining testcertificate and remitting of necessary fees
8OD300808/2025-2026:11 KV Switch gear(Indoor) - Supply, erection, testing and commissioning of 11KV, 630A, 350MVA, totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation and draw out type vacuum circuit breaker single panel system (1 no. VCB ) suitable for installation in 3 phase , 3wire, 50Hz. AC,11kv, effectively earthed supply system, comprising of motorized and spring assisted, independent, trip free closing mechanism and all metering equipment, protective relays,heating coils etc. complete as approved by Kerala Electrical Inspectorate and relevant standards. Armored multi core 2.5 Sq.mm copper control cables shall be used for all external internal interconnections. The cost of control cables both internal and external shall be included in the cost of HT panel.
9OD300809/2025-2026:OUTDOOR TRANSFORMERS - Supply erection testing commissioning of 11KV/433V, 3 phase, 50 Hz, Vector group Dyn-11, Copper wound,Energy Efficiency Level-1, ONAN cooled, Outdoor, 1000KVA Transformer (Continuous rating) with on load tappings with AVR unit from +5% to -10% in steps of 2.5%, first fill of Oil upto MOL in the conservator. Transformer should have cable end box on HT side, LT side bus trunk with all other standard fittings and accessories, complete as required as per KSEI specifications and confirming to IS 1180.
10OD300777/2025-2026:NEUTRAL CT WITH ENCLOSURE - Supply Installation, Testing and Commissioning of Neutral CT for the Transformers having CT ratio of 100/5, 15VA, class 5P10. It should be placed in a protected Metal box with facility for Testing.
11OD300774/2025-2026:Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50 Hz A.C. supply with metal clad enclosure made of 1.6mm thick steel sheet duly powder coated in convenient section complete with 4 Nos aluminium bus bars, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size( one on each side) including G.I clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.2000 amps 50 KA SC for 1 sec
12OD300795/2025-2026:MV PANEL BOARDS - Supply, Installation, Testing and Commissioning of cubicle type, dust and vermin proof, IP-42, floor mounted, front operated, top/bottom cable entry, extensible type MV panel board complying to IS 8623 (with latest amendments) made out of 14/16 SWG thick CRCA sheet fully compartmentalised as per approved design and requirements, hinged doors for all switch gear compartments with door interlock, earthing the doors using 4sqmm braided copper conductor, detachable cover for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc.Name plate, danger notice board, neopreme gaskets for all openable doors & covers, removable gland plates made of 3mm thick sheet steel,all connections and inter-connections including mounting the following switch gears and accessories as per approved schematic drawings. The panel shall be fabricated by a CPRI approved vendor. CRCA sheet alone be used for the fabrication except base channel by using ISMC -75. FRP shrouding shall be provided wherever necessary and Louvers for bus bar chamber.1.5sqmm. Copper flexible cable shall be used for control wiring & 2.5sqmm. for CT wiring. GA drawings of Panel boards has to be get approved by the Engineer in charge /Consultant before fabrication of Panel Board.. MAIN SWITCH BOARD (a) Incomer: 2000A, 4P,50KA, FP, MDO, Microprocessor based, ACB with 3 O/C & 1 E/F release, Shunt release - 1 nos.,.(b) Bus bar: 2500A TPN electrolytic grade Aluminium busbar with SMC supports, heat shrinkable sleeves as per colour code, etc.(d) Meters and CTs: Multi Function Meter capable of measuring each phase Amps, Kilowatts, PF, Hz, kWh, kVArh, MD for system, programmable CT ratio with necessary CTs etc. - 2 nos. RYB phase indicating lamps (lamps shall be LED ) with control Fuses -2 set, Electronic Voltmeter -1 nos. (For 1Nos of TFR incomer). ON, OFF, Trip indication lamps -3 set (For 1 nos. TFR Incomer ). Relays: Stand by Earth fault relay - 1nos., Reverse power relay with CTs and control fuses -1 set, Master trip relay -1nos.(f) Outgoings: (1) 630A, 50kA, TP, Microprocessor based MCCB, Ics=100% Icu with adjustable setting range, Spreader Terminals, Phase Barriers and Rotary operating mechanism, plus Neutral link - 7 nos.),
13OD300776/2025-2026:Sub Switch Board (SSB) -Supply, erection and commissioning and (a) Incomer: 400A, TPN, Isolator - 1 no.(b) Bus bar: 400A TPN electrolitic grade Aluminium busbar with SMC supports, heat shrinkable sleeves as per colour code, etc.,(c) Meters and CTs: RYB phase indicating lamps (lamps shall be LED ) with control Fuses -1 set, ElectronicVoltmeter -1no., Ammeter (0 -400A) with CT -3nos.(d) Outgoings: (1) 250A, 25kA, TP, MCCB, Ics=100%Icu with adjustable setting range, Spreader Terminals, Phase Barriers and Rotary operating mechanism plus Neutral link - 3 nos. (2) 80A, 25kA, TP, MCCB, Ics=100% Icu with adjustable setting range, Spreader Terminals, Phase Barriers and Rotary operating mechanism, plus Neutral link - 1 No
14OD300773/2025-2026:MCB DISTRIBUTION BOARDS - Supply Installation, Testing & Commissioning of dust and vermin proof, MCB DB, IP-43, with metal door, including copper busbar, neutral link, DIN bar, necessary dummy plates, RCBO/RCCB/MCB/MCB Isolator as incomer and SPMCB/3PMCB (10KA) as outgoings etc. Fixed on wall using suitable anchor bolts or fixed in recess including cutting holes, rough plastering, etc. as required. 4 WAY, 3 PHASE, DOUBLE DOOR, VDB, IP 43.Incomer: 63A, 4P, MCB IsolatorOutgoings: 6/10/16A SPMCB -3nos, 32A, 3P, MCB-3nos
15OD300794/2025-2026:MCB DISTRIBUTION BOARDS - Supply Installation, Testing & Commissioning of dust and vermin proof, MCB DB, IP-43, with metal door, including copper busbar, neutral link, DIN bar, necessary dummy plates, RCBO/RCCB/MCB/MCB Isolator as incomer and SPMCB/3PMCB (10KA) as outgoings etc. Fixed on wall using suitable anchor bolts or fixed in recess including cutting holes, rough plastering, etc. as required. 4 WAY, 3 PHASE, DOUBLE DOOR, ETPN DB, IP 43.Incomer: 32A, 4P, RCBO 30mA -1no.Outgoings: 6/10/16A/20A SPMCB -12nos
16OD300820/2025-2026:SUPPLY OF MV XLPE ARMOURED CABLE (A2XFY/A2XWY) - Supply of 3.5x240sq.mm Armoured XLPE power cable AL conductor of best conductivity 1.1KV grade strictly conforming to IS:7098 (Part-I) 1988 .
17OD300817/2025-2026:SUPPLY OF MV XLPE ARMOURED CABLE -(A2XFY/A2XWY) Supply of 3.5x35sq.mm Armoured XLPE insulated and PVC sheathed power cable AL conductor of best conductivity 1.1KV grade strictly conforming to IS:7098 (Part-I) 1988 .
18OD300784/2025-2026:SUPPLY OF MV XLPE/PVC ARMOURED CABLE - (A2XFY/A2XWY) Supply of 4x10sq.mm Armoured XLPE power cable AL conductor of best conductivity 1.1KV grade strictly conforming to IS:7098 (Part-I) 1988 .
19OD300798/2025-2026:SUPPLY OF MV XLPE ARMOURED CABLE - (A2XFY/A2XWY) Supply of 3x4sq.mm Armoured XLPE power cable AL conductor of best conductivity 1.1KV grade strictly conforming to IS:7098 (Part-I) 1988 .
20OD300805/2025-2026:LAYING OF MV XLPE (A2XFY/A2XWY) ARMOURED CABLE - Laying of 240 sq.mm 3.5 core Armoured XLPEpower cable AL , 1.1KV grade of the following sizes in the existing masonry open duct as required and approved by the Engineer in charge.
21OD300779/2025-2026:LAYING OF MV XLPE/PVC ARMOURED CABLE - Laying of 35 sq.mm Armoured XLPE power cable AL , 1.1KV grade of the following sizes in the existing masonry open duct as required and approved by the Engineer in charge.
22OD300772/2025-2026:LAYING OF MV XLPE/PVC ARMOURED CABLE - Laying of 4X10 sq.mm Armoured XLPE power cable AL , 1.1KV grade of the following sizes in the existing masonry open duct as required and approved by the Engineer in charge.
23OD300778/2025-2026:MV CABLE END TERMINATION - Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminiumconductor cable of 1.1 KV grade as required. 3.5 C x 240 sqmm
24OD300792/2025-2026:MV CABLE END TERMINATION - Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminiumconductor cable of 1.1 KV grade as required. 3.5C x 35sq.mm
25OD300793/2025-2026: Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminiumconductor cable of 1.1 KV grade as required. 4 X 10 sqmm
26OD300783/2025-2026:COPPER CONTROL CABLE - Supply of 3Cx2.5sq.mm Armoured XLPE PVC insulated and PVC sheathed copper control cable of best conductivity 650V grade strictly conforming to IS:7098 (Part-I)1988
27OD300819/2025-2026:COPPER CONTROL CABLE - Supply and Laying and clamping of 12Cx2.5sq.mm Armoured XLPE/PVC insulatedand PVC sheathed copper control cable of best conductivity 650V grade strictly conforming to IS:7098(Part-I) 1988
28OD300780/2025-2026:LAYING OF MV XLPE/PVC ARMOURED CABLE - Laying of one number 3Cx2.5 sq.mm Armoured XLPE/PVC insulated and PVC sheathed power cable Cu , 1.1KV grade of the following sizes in the existing masonry open duct as required and approved by the Engineer in charge.
29OD300812/2025-2026:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3C x2.5sq.mm
30OD300815/2025-2026:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 12C x2.5sq.mm
31OD300816/2025-2026:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories,and providing masonry enclosure with cover plate having locking arrangement andwatering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
32OD300814/2025-2026:COPPER STRIP - Supply of 50x5 mm earthing conductor of Cu strip / wires jointing as per IS:3043 / 87 in trench walls pulling through pipes etc. as required. All joints shall be tinned by using lead.
33OD300801/2025-2026:COPPER STRIP - Labour charges for laying / fixing of 50x5mm earthing conductor of Cu strip / wires jointing as per IS:3043 / 87 in trench walls pulling through pipes etc. as required. All joints shall be tinned by using lead
34OD300810/2025-2026:MS CABLE TRAYS - Supply and fixing of vertical and horizontal type cable trays and cable supports fabricated out of MS angles (ISA) and MS flats with sufficient width and spacing between successive cross members and supported at adequate spacing. The cable trays and supports shall be painted with two coats of Zinc Chromate primer and two coats of black enamel paint. The design of cable trays and details shall be got approved by the Engineer in-charge
35OD300791/2025-2026:MS CABLE TRENCH COVERS - Supply and fixing ,of Cable trench covers using 6mm thick MS Chequered plate forcovering cable trench in Substation as required. The cable trench covers shall be painted with two coats of Zinc Chromate primer and two coats of black enamel paint
36OD300807/2025-2026:WIRING USING MODULAR SWITCHES - Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
37OD300806/2025-2026:WIRING USING MODULAR SWITCHES - Supply of all materials and point wiring for light point / exhaust fan point / call bel point 240V AC circuits through 20mm dia. medium gauge PVC conduits with 3 runs of 1.5 sq.mm(14/0.3) single core PVC insulated Cu wire for distribution, 6A control switches, 6A sockets, Metal boxes, Mounting plates etc. as necessary for the following items. The wiring should be done over the surface /open/concealed with Modular type switches & sockets including conduits. The circuit mains will be measured seperately.1 No , 6A socket outlet controlled by 1 no 6A, SP switch along with other switches
38OD300821/2025-2026:WIRING USING MODULAR SWITCHESP - Labour charge for,1 point wiring for light point / exhaust fan point / call bel point 240V AC circuits through 20mm dia. medium gauge PVC conduits with 3 runs of 1.5 sq.mm(14/0.3) single core PVC insulated Cu wire for distribution, 6A control switches, 6A sockets, Metal boxes, Mounting plates etc. as necessary for the following items. The wiring should be done over the surface /open/concealed with Modular type switches & sockets including conduits. The circuit mains will be measured seperately. 1 No 16/6A socket, controlled by 1 No 16A Modular type SP switch.
39OD300790/2025-2026:CIRCUIT MAINS /POWER CIRCUIT - Supply of all materials for laying and termination of PVC insulated Cu wires through 20mm dia. Medium gauge, PVC conduits for the following types of wires includingbconduits and accessories.Circuit main wiring using 3 runs of 2.5sq.mm PVC insulated Cu wires, through 20mm dia mediun gauge PVC conduit
40OD300802/2025-2026:LIGHT FITTINGS - Supply and fixing of the following light fittings on the ceiling/wall, etc, including mounting consumables, 3x1sqmm copper flexible cable, etc.22W LED lube light 240V 50Hz
41OD300799/2025-2026:LIGHT FITTINGS - Supply of the following light fittings on the pole /wall, etc, including mounting consumables, 3x1sqmm copper flexible cable, etc 30W LED Streetlight IP66. 240V 50HZ
42OD300782/2025-2026:Supply and fixing ceiling fan 1200mm sweep with electronic regulator including cost of fan regulator and fixingcharges 240V 50Hz
43OD300800/2025-2026:Supply and installation of 6 kg Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required
44OD300788/2025-2026:SAFETY ITEMS - "Supply and fixing of 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand, etc. as required
45OD300771/2025-2026:SAFETY ITEMS - \\"Supply and fixing of First-Aid Box with essential medicines along with First Aid Chart duly framed and placed ina conspicuous location for clear vision
46OD300775/2025-2026:SAFETY ITEMS - Supply & fixing of MV voltage danger notice board 200mmx150mm
47OD300781/2025-2026:SAFETY ITEMS - Supply & fixing of high voltage danger notice board 250mmx200mm size vitrousenamelled
48OD300797/2025-2026:SAFETY ITEMS - Supply of HT Hand Gloves 2 pair and 32mm Telscopic High Voltage Discharge Earth Rod 3 stage 18F fiber glass finishing with 6Sq.mm copper wire 6M with crocodile clip
49OD300813/2025-2026:Supply and fixing of cable route marker with 100mm x 100mm x 5mm thick GI plate with inscriptionthere on, bolted / welded to 35mm x 35mm x 6mm angle iron, 600mm long and fixing the same in groundas required
50OD300786/2025-2026:Labour charges for Dismandling of OLD MSB and shifted around 50M distance as per the direction ofEngineer in charge.
51OD300811/2025-2026:\\"Statutory Approval - Obtaining statutory approval from Eletrical Inspectorate including preparation ofdrawings, obtaining approval for the drawings arranging inspection of the installations and obtainingsafety certificate etc.after completion of the work and avail supply from KSEB. The necessary statutory fees if any payable to theElectrical Inspectorate/ KSEB will be paid by KWA (Note: Scheme approval from the Electrical Inspectorate has to be obtained before supplying the equipments. Payment for the supply of materials (Electrical side ) will be released only on production of schemeApproval.)
52OD300789/2025-2026:POWER ALLOCATION FROM KSEB - Preparation of application for enhancing the contract demandfrom 400kVA to 630 kVA, follow up with KSEB offices like Section office, Sub Division office, Divisionoffice, Circle office and obtaining power allocation from KSEB. Preparation of new HT agreement &completion report, arranging inspection by KSEB officials from Section office, Sub Division office, Divisionoffice, Circle office and giving assistance to TMR Division for commissioning of CT/PT Unit & TOD Meterexcluding statutory fees
53OD73377/2026-2027:Servicing, dismantling, inspection, repair, reassembly, testing and commissioning of the existing old and damaged pump-motor set installed at Kalathara Raw Water Pump House, including replacement of worn-out components as required, complete in all respects.
5411KV 1000KVA Sub station Building at Kalathara RWPH
552.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
562.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
574.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 gradedstone aggregate 40 mm nominal size derived from natural sources)
585.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
595.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
605.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
615.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
625.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
635.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
645.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
655.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
665.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges
672.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
6850.6.1.8:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete
6913.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
7013.12:18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand )and a top layer 6 mm thick cement plaster 1:3 ( 1 cement : 3 coarse sand) finished rough with sponge.
7113.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
7213.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
7313.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
7413.50.3:Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works
7513.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
7610.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
7710.7:Providing and fixing ball bearing for rolling shutters.
7821.3.3:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
7913.71:Lettering with black Japan pint of approved brand and manufacture
809.141:Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5 mm (±0.2mm), made out of single piece extruded PVC profile, with mitred cut joints and with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20 mm M.S. rectangular tube of 0.8 mm, including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8x100 mm long anchor fasteners complete, all as per manufacturer's specification and direction of Engineer-in--charge.
819.144:Providing and fixing 37 mm thick factory made PVC door shutter, styles and rails made of PVC hollow section of size 100 mm x 37 mm with wall thickness 2 mm ( ± 0.2 mm), with inbuilt bead on one side, styles and rails mitered cut and joint at the corners by means of 2 nos of plastic brackets of size 75 mm x 220 mm at each corners by means of 2 nos of plastic brackets of size 75 mm x 220 mm at each corner and stainless steel screws, reinforcing the hinge side of style by inserting corner and stainless steel screws, reinforcing the hinge side of style by inserting PVC profile of size 28 mm x 30 mm, with wall thickness 2 mm ( ± 0.2 mm). Lockrail of size 100 mm x 37 mm, wall thickness 2 mm (± 02. mm) will be fixed to the vertical styles. Providing with PVC snapfit beads and panel of size 100 mm x 20 mm, and inserting 2 nos tie bar of 6 mm dia and fastening with nuts and washers complete, all as per manufacturer's specification and direction of Engineer -in- charge.
8217.3.1:Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
8317.7.8:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers
8450.17.1.3:Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
8550.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge.
8650.18.8.2.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2
8750.18.8.9.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
8850.18.9.19.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
8918.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
9018.50.1:Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore
9118.53.1:Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore
9218.58.2.1:Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid150 mm nominal size square 100 mm diameter of the inner hinged round grating
9311.40:Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.
94OD300769/2025-2026:Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades
95OD300767/2025-2026:Supply,Conveying and Fixing Cylinderical PVC septic tank capacity 28/35 flush perday
96OD300770/2025-2026:Supply and providing SMC chequered plate of the following thickness including cutting, fixing with the existing frame-work etc. as required for the cable trench covering-8mm thick
9715.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
9815.3:Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
9915.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
1007.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
101OD300768/2025-2026:Conveying amd spreading 40mm stone aggragate around the Transformer base
102OD300766/2025-2026:Fencing with angle iron post placed at required distance embedded in cement concrete blocks, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire
10310.26.1:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57135404
AUTHORITY Local Bodies
TENDER VALUE 1.62 Crore
LAST DATE 01-09-2026
Authority
Authority Name Kerala Water Authority
Work Description Tender for Amrut-Augmentation Of Uwss To Nedumangad Muncipality-Upgradation Of Existing 13.75 Mld Water Treatment Plant At Perumala And Providing 3000 Fhtcs- Package 7-Supply And Erection Of Transformer And Other Related Works-Pipeline Work-Pipeline Work
Basic Detail
Tender No 08/2026-27/KWA/PHC/D3/TVM
Bidding Type Tender
Location
City Thiruvananthapuram
State Kerala
Key Dates
Publish Date 21 Aug 2026
Submission Date 01 Sep 2026
Open Date 02 Sep 2026
Finance
Tender Value 1.62 Crore
Tender Fee 5515
EMD 50000
Exemption Available
Document List
08NIT.pdf
9ec1d442-3690-4c65-ad08-fc01e539be0b.html
BOQ_1466308.xls
KWAGeneralConditionsforeT_1.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Sep 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
pdf

08NIT.pdf

html

9ec1d442-3690-4c65-ad08-fc01e539be0b.html

xls

BOQ_1466308.xls

pdf

KWAGeneralConditionsforeT_1.pdf

pdf

Tendernotice_1.pdf

Disclaimer