TGGENCO - KTPS-VII Stage - Chemical Div- Procurement Of Ph, Conductivity And Turbidity Meters - Quotation Called For - Regarding. , CONDUCTIVITY METER - Range: 0.001 Micro S/Cm To 2000 Ms/Cm - Resolution: +/-0.01 - Cell Constant: 0.1 1/Cm - Operating Temperature: 0-80 Deg C - Measuring Error (+/-1 Digit): Conductivity: +/-0.1%, Salinity/TDS: +/-0.5%, Temperature: +/-0.2 Deg C (0.36 Deg F) - Reproducibility: +/-1 Digit - Operating Humidity: Less Than 80% (Non-Condensing) - Temperature Compensation: Automatic Temperature Compensation (ATC), Built-In - Power Supply: 230 V AC, 50 Hz, Single Phase - Accessories: Spare Electrode And Calibration Standards - Make: HACH / EU TECH INSTRUMENTS / DKK-TOA / METTLER TOLEDO , DIGITAL Ph METER - Ph Range: 0 To 14 - Mv Range: 0 To +/-2000 Mv (Auto Polarity) - Resolution: +/-0.01 - Accuracy: Ph: +/-0.01, Mv: +/-0.1% - Repeatability: +/-0.01 - Mv Resolution: 1 Mv - Ph Electrode Calibration: 1 To 3 Point Calibration Within Given Buffer Set - Temperature Compensation: Automatic Temperature Compensation (ATC), Built-In - Operating Temperature: 0-80 Deg C - Operating Humidity: Less Than 80% Relative Humidity - Power Supply: 230 V AC, 50 Hz, Single Phase - Accessories: Spare Electrode And Calibration Standards - Make: HACH / EU TECH INSTRUMENTS / DKK-TOA / METTLER TOLEDO , PORTABLE TURBIDITY METER - Method: Ratio Turbidimetric Using Primary Nephelometric Light Scatter (90 Deg) - Lamp: Tungsten Filament - Range: 0-2000 NTU - Accuracy: +/-2% Of Reading Plus Stray Light From 0-500 NTU - Repeatability: +/-1% Of Reading Or 0.01 NTU, Whichever Is Greater - Resolution: 0.01 NTU - Stray Light: 0.02 NTU - Display: Graphic LCD - Signal Averaging: Selectable ON/OFF - Detector: Infrared Emitting Diode (850 Nm) - Power: AC 100-240 V, 50/60 Hz With Power/USB Module Or 4 AA Alkaline/Nimh Batteries - Operating: 0-50 Deg C, RH 0-90% At 30 Deg C, 0-80% At 40 Deg C, 0-70% At 50 Deg C, Non-Condensing - Storage: -40 To 60 Deg C - Interface: Optional USB - Sample Volume: 10 Ml - Calibration Standards: 0.02, 20, 100 And 800 NTU - Accessories: Carrying Case, Power Adapter/Charger, 4 AA Batteries, 6 Sample Cells, Primary Standard Calibration Kit, Instruction Manual - Make: HACH / EU TECH INSTRUMENTS / DKK-TOA / METTLER TOLEDO - Specifications As Per Tender Documents Only
BOQ
| Sl. No. | Item Name |
| 1 | CONDUCTIVITY METER - Range: 0.001 micro S/cm to 2000 mS/cm - Resolution: +/-0.01 - Cell Constant: 0.1 1/cm - Operating Temperature: 0-80 deg C - Measuring Error (+/-1 digit): Conductivity: +/-0.1%, Salinity/TDS: +/-0.5%, Temperature: +/-0.2 deg C (0.36 deg F) - Reproducibility: +/-1 digit - Operating Humidity: less than 80% (Non-condensing) - Temperature Compensation: Automatic Temperature Compensation (ATC), Built-in - Power Supply: 230 V AC, 50 Hz, Single Phase - Accessories: Spare electrode and calibration standards - Make: HACH / EU TECH INSTRUMENTS / DKK-TOA / METTLER TOLEDO |
| 2 | DIGITAL pH METER - pH Range: 0 to 14 - mV Range: 0 to +/-2000 mV (Auto Polarity) - Resolution: +/-0.01 - Accuracy: pH: +/-0.01, mV: +/-0.1% - Repeatability: +/-0.01 - mV Resolution: 1 mV - pH Electrode Calibration: 1 to 3 point calibration within given buffer set - Temperature Compensation: Automatic Temperature Compensation (ATC), Built-in - Operating Temperature: 0-80 deg C - Operating Humidity: less than 80% Relative Humidity - Power Supply: 230 V AC, 50 Hz, Single Phase - Accessories: Spare electrode and calibration standards - Make: HACH / EU TECH INSTRUMENTS / DKK-TOA / METTLER TOLEDO |
| 3 | PORTABLE TURBIDITY METER - Method: Ratio Turbidimetric using Primary Nephelometric Light Scatter (90 deg) - Lamp: Tungsten Filament - Range: 0-2000 NTU - Accuracy: +/-2% of reading plus stray light from 0-500 NTU - Repeatability: +/-1% of reading or 0.01 NTU, whichever is greater - Resolution: 0.01 NTU - Stray Light: 0.02 NTU - Display: Graphic LCD - Signal Averaging: Selectable ON/OFF - Detector: Infrared Emitting Diode (850 nm) - Power: AC 100-240 V, 50/60 Hz with Power/USB Module or 4 AA Alkaline/NiMH Batteries - Operating: 0-50 deg C, RH 0-90% at 30 deg C, 0-80% at 40 deg C, 0-70% at 50 deg C, Non-condensing - Storage: -40 to 60 deg C - Interface: Optional USB - Sample Volume: 10 mL - Calibration Standards: 0.02, 20, 100 and 800 NTU - Accessories: Carrying Case, Power Adapter/Charger, 4 AA Batteries, 6 Sample Cells, Primary Standard Calibration Kit, Instruction Manual - Make: HACH / EU TECH INSTRUMENTS / DKK-TOA / METTLER TOLEDO - Specifications as per Tender Documents only |