Tender For special Repair Of Bldg No Tw/42, Cook House (Bldg No Ch-19) And Bldg No Te/368 (Jco Mess) At Mtn Arty Bde Camp Sig Coy Of Age B/R And Age E/M Under Ge Tenga
Tender Value
40.40 Lakhs
Estimated cost
Bid Submission
11 Sep 2026
19 days left
EMD
80800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
kameng → Arunachal Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair Of Bldg No Tw/42, Cook House (Bldg No Ch-19) And Bldg No Te/368 (Jco Mess) At Mtn Arty Bde Camp Sig Coy Of Age B/R And Age E/M Under Ge Tenga
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling plain or corrugated steel sheeting of any thickness as in roof coverings complete all as specified and directed. |
| 2 | Supply and Fix Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed (Note:- Item rate shall be include any height of Bldgs / Hangars for scaffolding as all arrangement.) |
| 3 | Supply and Fix Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed (Note:- Item rate shall be include any height of Bldgs / Hangars for scaffolding as all arrangement.) |
| 4 | Supply and Fix 0.63 mm thick galvanised, corrugated mild steel sheeting with two corrugation side lap, fixed with L-type or J-type or cranked hook bolts in lieu of screws and washers, in roofs, walls etc. with grade of zinc coating 275 gsm complete all as specified and as directed. |
| 5 | S & F 0.63 mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 complete, all as specified and directed. |
| 6 | S & F 0.80 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed. |
| 7 | M & L for applying two coat of synthetic enamel paint over a coat of red oxide primer to steel and iron surfaces of any description over 10 cm in width or girth not otherwise described including preparation of new steel surfaces. |
| 8 | Material and labour for preparation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed. |
| 9 | Material and labour for preparation of old painted steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint all as specified and directed. |
| 10 | Demolition of cement concrete (unreinforced) in ground floors and paving’s not exc 15 cm thickness (below or above ground level) |
| 11 | M&L for 75 mm thick PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) as in sub floor |
| 12 | M&L for 15 mm thick screed bed in CM 1:6 for laying floor tiles. |
| 13 | M&L for 20 mm thick screed bed in CM 1:6 for laying floor tiles. |
| 14 | M&L for Vitrified Ceramic tiles dark shade 8 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match |
| 15 | M&L for chequered cement concrete tiles 20cmx20cmx25mm/ 30cmx30cmx25mm thick set with grey cemnt and no pigment, jointed and pointed in neat cement slurry in floor as specified and directed. |
| 16 | Dismantling timber scantlings framed work 40 sq. cm and over in section, in any position |
| 17 | S&F for Second class hard-wood clean sawn timber framed & fixed in scantlings fixed with nails in any situation. |
| 18 | Dismantling of wall and ceiling board or insulation boards/slabs/blanckets/any thickness including cover fillets |
| 19 | S & F for anodixed aluminum snap grid of size 605 x 605 mm frame work for false celling with aluminum anodized section size, wall angle 40mm x 25mm x 2mm thick, main /crosstee-section 36.5mm x 25mm x 1.4mm and 23.5mm x 26.4mm x 1.4mm and suspended with 6mm dia GI wire respectively with and including 8mm thick liminated laminated Gypsum board fixd to aluminum snap grid all as per clause 10.38.1 of SSR Part-I and as per manufacturer's instructions complete all as specified and as directed by Engineer -in-charge make: (i) Aluminum section : VALCO, HINDALCO, JINDAL (ii) Gypsum board :- GYPSUM INDIA Ltd/LA Gyp Eco board, Armstrong, SaintGobain. |
| 20 | S&F 6 mm thick ply wood, grade BWR, type BB, fixed with nails to timber frame work on wall surfaces. |
| 21 | M&L for preparation of new wooden surfaces of any description, not other wise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer. |
| 22 | M & L preparation of Old wood/plywood or wood / plywood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint all as specified.. |
| 23 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exc 4 Sqm. |
| 24 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm |
| 25 | Taking down shutters of any description exc 1 Sqm and n exc 2 Sqm each complete all as specified. |
| 26 | S & F 2nd class hard wood plain solid straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered, put together with glue pinned at joints complete |
| 27 | S & F 2nd class hard wood plain framed panelled shutter 35mm thick (any number of panels) with panels of timber flat on both sides, feather edged or of veneered particle board medium density, wood particle board with commercial face veneer 30mm thick |
| 28 | S&F for 35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panel only) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces, The size of rail and stile as per IS-1003 (Part-I) (Larger size to be provided) kiln seasoned and chemically pressure treated fitted to chowkats all as specified and directed |
| 29 | S & F 2nd class hard wood 30mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted with cut and mitred beads for securing glass,etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats |
| 30 | S&F 30 mm thick second class hard wood Glazed and skeleton shutters for window and ventilators etc, open rebated and prepared to receive glass, gauze, etc. (with sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.24 (b) |
| 31 | S&F for 2nd class hard wood 35mm thick glazed and skeleton door shutters factory made, open rebated and prepared to receive glass or gauge etc with rounded, chamfered or mitred sash bars edges of framing plain chamfered or rounded fitted with cut and mitred beads and fitted to chowkats for securing glass/gauge, size of stiles rails and other parts as per clause 8.24 (a) of SSR Part-I 2009 (Larger size to be provided) complete all as specified and directed |
| 32 | S & F 100mm size mild steel butt hinges medium weight cold rolled and fixed. |
| 33 | S & F 75mm size mild steel butt hinges medium weight cold rolled and fixed. |
| 34 | S& F Aluminium anodised barrel tower bolts 150mm long of extruded section and fixed |
| 35 | S& F Aluminium anodised barrel tower bolts 100mm long of extruded section and fixed |
| 36 | S & F 150mm size extruded aluminium alloy handles, fabricated type anodised |
| 37 | S & F 100mm size extruded aluminium alloy handles, fabricated type anodised |
| 38 | S & F aluminium alloy, anodised, sliding door bolts 300mm size with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed |
| 39 | S&F pre coated mild steel floor door stopper ,tongue anodized 140mm length including vulcanised rubber piece |
| 40 | S & F GI steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm etc all as specified. |
| 41 | S & F for stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with stainless steel wire staples all as specified & directed. |
| 42 | S & F Sheet glass 3mm,ordinary quality and glazing with oil putty in square n exc 0.5sq. m in each pane all as specified. |
| 43 | S&F PVC coated 25mm dia mild steel chromium plated curtain rod of medium weight and including fixing brackets, finals and decorative end supports etc complete all as directed” |
| 44 | S&F in repair 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed (Helical door closer). |
| 45 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar . |
| 46 | M&L for PCC 1:3:6 type C-1(20 mm graded aggregate) precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in CM 1:6 etc complete. |
| 47 | M&L for Rendering 10mm thick in CM 1:3 work or concrete surfaces to recive wall tiles. |
| 48 | M&L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed. |
| 49 | M&L for cement concrete type C-2, 1:3:6 (using 40mm graded agg) as in plinth protection and paving 75mm thick laid in slope finished even and fair without using extra cement incl making joints every 2.5m and corner filled with bitumen 85/25 complete all as specified. |
| 50 | Dismantling wrought iron or mild steel work of any description not otherwise provided for as specified & directed. |
| 51 | M&L for Steel work in tubular trusses including special shaped washer etc. complete usingERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 as specified & directed. |
| 52 | M&L for preparation of new surfaces of walls and applying two coats of cement base paint over a coat of alkali resitent primer as specified & directed. |
| 53 | M&L for preparation of old surfaces of walls and applying one coat of OBD over a coat of alkali resitent primer as specified & directed. |
| 54 | S&F mild steel work, Grade Fe-410-0 or Fe- 310-0, as in flat iron (for holdfast) complete all as specified and as directed. |
| 55 | M&L in repair second class hard-wood plain fillets exc 13 and n exc 25 sq cm square, rectangular or triangular in section, clean sawn, secured with nails or brads. |
| 56 | Dismantling structural steel work in cluding doors, gates but excluding framed truss etc. |
| 57 | M & L for PCC 1:3:6 type D-2 (using 40mm graded stone aggregate) as in foundation filling or mass concrete complete all as specified and directed. |
| 58 | S & F in mild steel work conforming to Fe 290 Gde-E-165 in posts, wall & struts angle including cutting top to shape as directed, drilling holes, notching for wire, etc; flat iron fillets ( for securing wire mesh etc) including all necessary drilling, bolting or riveting etc complete all as specified & directed. |
| 59 | S&F for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. |
| 60 | M&L for 40 mm thick PCC 1:2:4, type B-1 ( 20 mm graded aggregate) in flooring cmplete all as specified and directed. |
| 61 | S&F for non skid coloured Ceramic tiles 07-08 mm thick (square/ rectangular) area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 62 | M&L for 100 mm thk PCC 1:4:8 type D-2 (40mm graded aggregate) as in subbase to flooring complete all as specified and as diretcted. |
| 63 | M&L Rendering 15mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:4) in two layers (5mm finishing layer over 10mm base layer) finished even and smooth without using extra cement complete all as specified and directed |
| 64 | M&L PCC 1:3:6 type C-1 (using 20mm graded aggr) as in surface channels & drains,benching of manholes complete allas spd and directed. |
| 65 | Extra for forming fair finished drain or channel 30cm inner grith in cement concrete, using extra cement, including forms, moulds, mitred/stop ends etc. |
| 66 | Material and labour for washing rubbing down and stopping of distempered and painted surfaces applying two coat of oil bound distemper over 3mm wall care putty on walls all as specified and directed. |
| 67 | Material and labour for preparation of old treatment on external surfaces of walls and applying one coat of cement base paint (colour and tint as approved) on walls etc complete all as specified and directed. |
| 68 | S&F in repairs vitreous china wash hand basin white flat back of size 550mmx400 mm including CI brackets and waste pipe complete all as specified and directed |
| 69 | Material & Labour for Light/fan point wiring with 1.5 sq mm (nominal area), PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including PVC casing capping of adequate size with all fittings and accessories including PVC boxes for housing the switches ( Make of box Prestoplast,Prestoteak), including PVC insulated and unsheathed (FRLSH)single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. |
| 70 | All as per item No. 69 here in before One 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5sq. mm size |
| 71 | All as per item No. 69 here in before but for one 3 pin socket outlet 5 Amps three pin controlled by one switch on independent board complete all as specified directed. |
| 72 | All as per item No. 69 here in before but for one 5 pin socket outlet 15 Amp and 5 Amp Multipurpose independent using 2.5 Sqmm copper conductor cable (multi-strand) PVC insulated and unsheathed cable and 2.5 sqmm copper (multistrand) PVC insulated and unsheathed earth wire with terminal box of size 175mm x 100mm x 3.15mm complete all as specified. |
| 73 | S&F Switch socket combination 2 in 1, 6 Amp flush type |
| 74 | S&F Socket outlet 2 in 1, 3 pin, 5 amp flush type |
| 75 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type |
| 76 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 15 Amp, 240 Volts complete all as specified & directed. |
| 77 | Supply and fixing ceiling rose, surface bakelite, 65mm x 50mm , two to three terminals complete all as specified & directed. |
| 78 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 5 Amp, 240 Volts complete all as specified & directed. |
| 79 | Supply and fixing LED light fitting 1 x 20 Watt 220 volt AC decorative box type with driver, holder including LED tub light connecting up with three core flexible copper conductor cable of size from ceiling rose complete all as directed. |
| 80 | Supply and fix LED light fitting 1 x10W bulkhead luminaires inculding LED light driver holder connecting up with three core flexible copper conductor cable of suitable size |
| 81 | S&F LED bulkhead fitting 10 watt (Endura Ruby) with all accessories and including connenting up with twin core twisted with flexible copper conductor cable with suitable size of 230 volts , 50 hz complete all as specified and directed. |
| 82 | S&F of new generation energy saving and environmental friendly long life LED building security light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 45 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including twisted 3 core copper cable of size 1.5 Sqmm dia for connecting phase, neutral and earth from ceiling rose to light length as required at site,GI bracket 32 mm dia pipe and 02 numbers clmaps, all fixing arrangements such as fastners, bilts, nuts washers etc all as specified and directed. |
| 83 | Supply and fix sheet metal enclosures for DBs, double door when MCBs to be used 230 volts 8 way 200 Amp rated busbar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board complete all as specified and directed. |
| 84 | S&F MCB SPN having braking capacity 10KA, 40-63 Amps, 240 V complete all as specified and directed. |
| 85 | S&F MCB SP having braking capacity 10KA, 6 to 32 Amps, 240 V complete all as specified and directed. |
| 86 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge. |
| 87 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric cables with stranded aluminium conductor, 1100 volts grade, of 16 Sqmm 4 core complete all as specified and directed. |
| 88 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric cables with stranded aluminium conductor, 1100 volts grade, of 10 Sqmm 2 core complete all as specified and directed. |
| 89 | S & F incl leakage testing galvanised steel water tubing medium grade 20 mm dia bore with all fittings such as bends, elbow, socket, reducer,clamps etc, laid under floor / trenches/wall for cable protection all as specified & directed. |
| 90 | Taking down point wiring carefully copper/ aluminum (light,fan, socket or power) complete (fittings such as switches ceiling rose, pendents, regulators, sockets etc) |
| 91 | Taking down main switches, DBs alongwith existing board and removing the same from the site and making good the disturb surfaces / Portion of the wall etc all specified and directed by EIC. |
| 92 | Taking down sub main wiring of any type and size and discription incl removal from DBs etc and removal of the same from site and making good the disturb surfaces or portion of wall/ceiling etc complete all as specified and directed by EIC. |
| 93 | Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles/fencing posts etc and getting out soil complete all as specified and as directed. |
| 94 | Returning filling in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed. |
| 95 | Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed. |
| 96 | M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning. |
| 97 | Supplying and laying un-reinforced precast concerete cable cover, class LV, type 1 flat size 250mm x150mm x 40mm for cable protection , laid flat ie length of cable cover shall be laid across the cable all as specified and directed |
| 98 | Supply and fix exhaust fan,steel body AC single phase, 230V of size 450mm sweep heavy duty with blades, and frame and louvers complete all as specifed and directed. |
| 99 | Supply and fixing, metal clad socket out let with MCB single pole 20 Amp, 240 V including sheet metal enclosure complete fixed on flat iron 32x6 mm or 2nd class hard wood wooden board including complete electrical connection by proper size of copper lugs complete all as specified. |
| 100 | Supply and fix electric water heater(Geyser), storage type steel body with copper inner tank and heating element up to 2 KW capacity 50 litre, BEE 5 star rated adjustable temprature setting 0-90 degree C complete with accessories such as safety wall, thermostate, NRV indication lamps, inlet outlet connections,air vent connections, connection pieces including all fixing arrangements such as fastners, bilts, nuts washers etc including making good disturbed wall surfaces matching with the existing surface and finishing complete all as specified and directed by Engr in charge. |
| 101 | S & F incl leakage testing galvanised steel water tubing medium grade 15 mm dia bore with all fittings such as bends, elbow, socket, reducer etc, laid under floor / trenches all as specified & directed. |
| 102 | S&F Stop valves, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe of size 15 mm. |
| 103 | S&F Bib tap cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified & as directed by engr-in-charge. |
| 104 | M & L for PVC connections 15mm size with PTMT nuts of length 450mm for hot and cold water connection complete |
| 105 | Supply and fix sheet metal enclosures for Double Door DBs when MCBs to be used 230 volts 12 way 200 Amp rated busbar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board. |
| 106 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, (warm/white), 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as directed. |
| 107 | S & F incl leakage testing galvanised steel water tubing medium grade 50 mm dia bore with all fittings such as bends, elbow, socket, reducer etc, laid under floor / trenches all as specified & directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysSep 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 26 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender