Tender For Provn Of Store Near Or Mess At Mtn Arty Bde Sig Coy, 02Xtoilet Alongwith Urinal At Ukdd Near Top/21/01 Of Maratha Li, 01Xtoilet Block With 04Xwestern Commodes And special Repair To Bldg No Lp-372 At Lower Dahung Of Age B/R And Age E/M Unde
Tender Overview
Project Description
Tender for Provn Of Store Near Or Mess At Mtn Arty Bde Sig Coy, 02Xtoilet Alongwith Urinal At Ukdd Near Top/21/01 Of Maratha Li, 01Xtoilet Block With 04Xwestern Commodes And special Repair To Bldg No Lp-372 At Lower Dahung Of Age B/R And Age E/M Under Ge Tenga
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches n, exc 1.5 mtr wide and n, exc 1.5 mtr depth and getting out hard /dence soil, complete all as directed. |
| 2 | Excavating over areas, n.exc 1.5 mtr in depth; for foundation etc. and getting out in hard/dense soil as directed and specified by Engr-in-charge. |
| 3 | Excavating over areas, exc 1.5 mtr but not exc 3.00 mtr in depth; for foundation etc. and getting out hard/dense soil as directed and specified by Engr-in-charge. |
| 4 | Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles/fencing posts etc and getting out soil complete all as specified and as directed. |
| 5 | Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in hard / dense soil complete all as specified and as directed. |
| 6 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in hard/dense soil. |
| 7 | Return/filling in including spreading, levelling, watering and well remming in layers n.exc 25 cm complete all specified and directed |
| 8 | Removing excavated material n.exc 50m and depositing where directed at a level n exc 1.5m above the starting point.complate all specified and directed |
| 9 | Removal of excavated soil to a distance exc.50 Mtr and n.exc. 150 Mtr and deposited as directed by Engineer-in-Charge. |
| 10 | M & L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation filling or mass concrete, complete all as specified and directed. |
| 11 | S&F 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws etc complete all as specified and directed. (Note:- Item rate shall be include any height of Bldgs / Hangars for scaffolding as all arrangement.) |
| 12 | S&F Pre-Painted galvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour havimg testile strenght of 550 Mpa as in roof covering/ cladding to wall , fixed with self tapping screws as specified and directed. |
| 13 | S&F for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe 410-W (Gde E-250) quality A |
| 14 | S & F in mild steel work conforming to Fe 290 Gde-E-165 in posts, wall & struts angle including cutting top to shape as directed, drilling holes, notching for wire, etc; flat iron fillets ( for securing wire mesh etc) including all necessary drilling, bolting or riveting etc complete all as specified & directed. |
| 15 | M&L for brick work with fly ash bricks old Size bricks straight or curved on plan exc 6 mtr mean radius built in CM (1:6) all as spd and directed |
| 16 | M&L for brickwork with flyash bricks old Size bricks straight or curved on plan to any radius in half brick thick walls,built in CM (1:4) all as spd and directed |
| 17 | M&L Rendering 15mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:4) in two layers (5mm finishing layer over 10mm base layer) finished even and smooth without using extra cement complete all as specified and directed |
| 18 | M&L Rendering 10mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and as directed. |
| 19 | M&L Preparation of newly plastered or concrete surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 20 | M&L for preparation of new steel surfaces / MS sheet of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer all as specified and directed. |
| 21 | M&L three coats of white wash on surface of wall including preparation of new plastered surface complete all as spd and directed. |
| 22 | M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc.15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 23 | M&L for hard core of gauge n exc 63mm broken stone boulders, deposited,spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface etc complete all as spd. |
| 24 | M&L for 75 mm thk PCC 1:4:8 type D-2 (40mm graded aggregate) as in subbase to flooring complete all as specified and as diretcted. |
| 25 | M&L for 25 mm thick Cement concrete type B-1,1:2:4 (20mm graded aggregate) as in subbase to flooring complete all as specified and as diretcted. |
| 26 | S&F for non skid coloured Ceramic tiles 07mm to 08mm thick (square/ rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 27 | M&L for coloured Glazed ceramic tiles in vertical surface of wall 350x250x7mm/ 450mmX 350mmX 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles over and including 10mm thick rough cement plaster to receive tiles in CM 1:3 complete all as specified and as directed. |
| 28 | M&L for Cement concrete type C-2, 1:3:6 (using 40mm graded aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and fair incl making joints at every 2.5 m and at corner filled with bitumen 85/25 and sand in ratio 1:2 by weight and complete all as specified |
| 29 | S&F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet & edges will be painted to match with printed sheet ,reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 30 | S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded wood grain printed PVC sheet PVC ‘C’ channel having a plain colour PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheet for top rail,lock rail & bottom rail on either side & as gap insert for top rail & bottom rail;Panelling of wood grain printed PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable & 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (900 ) used instead of exposed portion of PVC sheet beading suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 31 | S & F 2nd class hard wood plain solid straight chowkats and frame of wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed. |
| 32 | S&F mild steel work, Grade Fe-410-0 or Fe-310-0, as in flat iron (for holdfast) complete all as specified and as directed. |
| 33 | S & F for glazed and Skelton shutters 30mm thick of 2nd class hardwood,open rebated and prepared to receive glass, guaze etc (Without Sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc;sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); suppplied and fitted to chowkats. |
| 34 | S & F 30mm thick 2nd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass, gauze etc but divided into squares, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads etc for securing glass etc; sizes of members of shutters as specified in SSR Part I section 8 clause 8.24(a) supplied and fitted to chowkhats |
| 35 | M&L 3 mm thick plain glass sheets ordinary quality in squares n exc 0.5sqm each pane fixed with aluminium frame work etc all as specified and directed. |
| 36 | S & F 3mm thick figured glass, pin head glazing with oil putty /wooden beads in squares n exc 0.50 Sqm in each pane. |
| 37 | S&F for 100 mm long Butt hinges, medium weight, cold rolled mild steel, and fixed |
| 38 | S&F 100mm size Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed.complete all specified and directed |
| 39 | S&F 100mm size stainless steel butt hinges, medium weight, cold rolled complete with stainless steel screw etc. all as specified as directed. |
| 40 | S&F for 75 mm long Butt hinges, medium weight, cold rolled mild steel, and fixed |
| 41 | S&F for Aluminium, anodised, barrel tower bolts of extruded section and fixed, Length of bolt in 150mm complete all as specified and directed |
| 42 | S&F for Aluminium, anodised, barrel tower bolts of extruded section and fixed, Length of bolt in 100mm complete all as specified and directed |
| 43 | S & F 150mm size extruded aluminium alloy handles, fabricated type anodised |
| 44 | S & F 100mm size extruded aluminium alloy handles, fabricated type anodised |
| 45 | S & F aluminium alloy, anodised, sliding door bolts 300mm size with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed |
| 46 | S&F for 20mm bore Steel water tubing 'medium grade', galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed. |
| 47 | S&F 15mm bore tubes medium grade galvanized ISI marked with all fittings short pieces and fixed including concealed pipe to walls, floor, ceiling etc complete all as specified. |
| 48 | S & F for 15 mm bore Angle/ Stop valves, fancy type, chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 49 | S & F for 15 mm bore long body CP Bib taps cast copper alloy fancy type with capstan heads (chromium plated),and cup screwed down , high pressure for iron pipe mpete all as spd & directed. |
| 50 | S&F 15 mm dia bib taps, fancy type chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed. |
| 51 | S&F for 15mm dia 600 mm long PVC connection including brass check nut at both ends screwed both end for iron pipes. |
| 52 | S&F PVC connection of 15 mm size with PTMT nuts of length 450 mm |
| 53 | S & F for 32/40 mm bore PVC waste pipe flexible with minimum length 800mm complete all as specified and directed. |
| 54 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified |
| 55 | S&F for Vitreous China wash down water closet pan including P or S trap of bore 125/110 mm (pedestal pattern), white or in matching colour of tiles (excluding flushing cistern and flush pipe) including plastic water closet seat, white or in matching colour , closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device and wash down water closet complete all as specified and as directed. |
| 56 | S&F for CP Pillar taps fancy type 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks & fly-nuts, screwed for iron pipe complete all as specified and directed. |
| 57 | S&F for Viterous China wash basin, white, flat back, size 550x400mm excluding taps etc but including brackets,including cutting for and pinning in ends of brackets or erecting stand but including waste coupling of fixing of supply and waste pipe complete all as specfied and as directed. |
| 58 | S & F for Vitreous China Half stall urinal White complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete all as specified and directed |
| 59 | M&L for viterous china urinal partition white of size 310 x 700mm urinal partions slabs, terminating about 40cm above floor, fixed in repairs complete all as specified and directed. |
| 60 | S&F for 600 mm x 450 mm bevelled edge mirror of selected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as spd. |
| 61 | S&F for soap dish of size 160x160x90mm, fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 62 | S&F for PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors all as specified and directed. |
| 63 | S&F for PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors all as specified and directed. |
| 64 | S&F for PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls all as specified and directed. |
| 65 | S&F for PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls all as specified and directed.(ISI MARKED) |
| 66 | S&F for PVC (SWR) bends any radius 75mm dia all as specified and directed.(ISI MARKED) |
| 67 | S&F for PVC (SWR) bends any radius 110mm dia all as specified and directed.(ISI MARKED) |
| 68 | S&F PVC (SWR) junction single, (single T) equal or unequal with access door 110mm dia. |
| 69 | S&F PVC (SWR) vent cowl 110mm dia |
| 70 | S&F PVC (SWR) WC connector 110mm dia lip ring. |
| 71 | S&F 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement. |
| 72 | S&F PVC (SWR) bends any radius with access door, 75mm dia. |
| 73 | M&L for 20 mm thick screed bed in CM 1:6 for laying floor tiles . |
| 74 | M&L for chequered cement concrete tile 30cmX30cmX 20 to 25mm thick set jointed and pointed in neat cement siurry in floor with grey cement and pigments complete all as specified and as directed. |
| 75 | M & L TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 76 | M & L TMT 6 to 8 mm cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 77 | M&L for MS TMT bars but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to lenth, bend to shape required, including cranking, bending, sprially for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. |
| 78 | M&L for Reinforced cement concrete Type B1, 1:2:4 (Nominal Mix) (20 mm graded agreggate) slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like |
| 79 | Use & waste for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) |
| 80 | Use & waste for Formwork to edges of concrete flats, treads, breaks in floors,window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 10cm but n exc 20cm wide rough finish surface of concrete |
| 81 | Use & waste Form work to edges of concrete flat, tread, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5 cm but n.exc 10 cm wide for rough finish surfaces of concrete. |
| 82 | M&L Pre-cast cement concrete cover slab for manhole and drain cover in plain cement concrete 1:2:4 type B-1, (using 20 mm graded stone aggregate) set in cement mortar 1:4 with plain faces complete all as specified and as directed. (Note:- Reinforcement shall be measured and paid seperately) |
| 83 | M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces to be finished even and smooth without using extra cement mixed with intergral water proofing compound @ 3% by weight of cement (WPC measured and paid separately) all as specified and as directed. |
| 84 | Supply only integral water proofing compound all as specified and as directed. |
| 85 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 86 | S&F for rotational moulded polyethlene water storage tanks three layers of 1000 ltrs capacity ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed. |
| 87 | S&F ball brass valves high pressure with polythene float and fly nut complete screwed for iron pipes of 20 mm dia or brass ferrule and fixed, all as directed. |
| 88 | S&F ball brass valves high pressure with polythene float and fly nut complete screwed for iron pipes of 15 mm dia or brass ferrule and fixed, all as directed. |
| 89 | M&L cement concrete type B-1 (1:2:4) (20 mm graded aggregate) as in kerb stones ,coping, bed plates and the like including weathering, slightly roundered or chamfered angles and throating, as directed including necessary form work and finishing complete all as specified. |
| 90 | M&L PCC 1:3:6 type C-1 (using 20mm graded aggr) as in surface channels & drains,benching of manholes complete allas spd and directed. |
| 91 | Extra for forming fair finished drain or channel 30cm inner grith in cement concrete, using extra cement, including forms, moulds, mitred/stop ends etc. |
| 92 | Demolition of cement concrete (unreinforced) in ground floors and paving’s not exc 15 cm thickness (below or above ground level) |
| 93 | M&L for 15 mm thick screed bed in CM 1:4 for laying floor tiles . |
| 94 | M&L for light shade vitrified tiles 10mm thick (square/rectangular) polished, area of each tile not exceeding .36 sqm,in floors etc set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade. |
| 95 | M & L for 10mm thick rendering in CM 1:3 on fair faces of brick work or concrete surfaces finshed rough to receive tiles . |
| 96 | M&L for light shade vitrified tiles 10mm thick (square/rectangular) polished, area of each tile not exceeding .36 sqm,in skirting etc set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade. |
| 97 | Dismantling plain or corrugated steel sheeting of any thickness as in roof coverings complete all as specified and directed. |
| 98 | Dismantling wrought iron or mild steel work of any description |
| 99 | Demolition of precast cement concrete articles and precast concrete block walling built in cement mortar |
| 100 | M & L Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and using PCC type C-1, 1:3:6 (20mm graded agg) and setting in cement mortar 1:6 complete. |
| 101 | Material and labour for rendering 15 mm thick rendering in cement mortar 1:4 on brick or concrete surfaces finished fair and even without using extra cement complete all as specified and directed. |
| 102 | Material and labour for preparation of newly plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of alkali resistant primer all as specified. |
| 103 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 104 | Dismantling of wall and ceiling board or insulation boards/slabs/blanckets/any thickness including cover fillets |
| 105 | S&F for anodised aluminium snap grid of size 605X605X mm frame work for false ceiling with aluminium anodized section size, wall angle 40mm X25mmX2mm thk, main/cross tee-section 36.5 X 25 X 1.4mm and 23.5mm X 26.4mm X 1.4mm and susupended with 6mm dia GI wire respectively with and including 8mm thk laminated Gypssum board fixed to aluminium snap grid all as per clause 10.38.1 of SSR Part-I 2009 and as per manufacturer's instructions complete all as specified and as directed by Engineer -in-charge make:(i) Aluminium section : Valco,HINDALCO, JINDAL (iI) Gypsum Board: GYPSUM IND LTD,SAINT GOBLIN |
| 106 | M&L for preparation of new wooden surfaces of any description, not other wise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer. |
| 107 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exc 4 Sqm. |
| 108 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm |
| 109 | S&F 30mm flush shutters, solid core construction with particle board core and plywood face panels, commercial type on both side and both face is covered with decorative face veneer with lipping/frame tp match all as completed and specified as directed. |
| 110 | S&F MS window grills, window frames etc articles confirming to o Fe.290.Gde-E-165 |
| 111 | S&F pre coated mild steel floor door stopper ,tongue anodized 140mm length including vulcanised rubber piece |
| 112 | S & F GI steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm etc all as specified. |
| 113 | S&F PVC coated 25mm dia mild steel chromium plated curtain rod of medium weight and including fixing brackets, finals and decorative end supports etc complete all as directed” |
| 114 | M&L for cement concrete type D-2, 1:4:8 (40mm graded aggregate) in Cement concrete in foundations, filling and mass concrete complate all specified and directed |
| 115 | M&L for Reinforced cement concrete nominal mix type B0 1:2:4 (12.5mm graded aggregate) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all specified and directed |
| 116 | M&L for Reinforced cement concrete nominal mix type B0 1:2:4 using 12.5mm stone aggreggate for Columns, pillars, piers, posts and struts complete all specified and directed |
| 117 | M&L for Reinforced cement concrete nominal mix type B0 1:2:4 using 12.5mm stone aggregate for Beams, cantilevers, bressumm ers, lintels over 1.5m complete all specified and directed |
| 118 | S&F of Formwork square or rectangular to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. |
| 119 | S&F of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter |
| 120 | S&F of Formwork square or rectangular to sides of pillars, posts, struts, piers, columns and stanchions complete all specified and direceted |
| 121 | Supply and fixed 6 mm thick plywood , graded BWR, type BB fixed with nails to timber frame work fixed to walls surface etc complete all as specified and directed. |
| 122 | Supply and fixed 4 mm thick plywood , graded BWR, type BB fixed with nails to timber frame work fixed to walls surface etc complete all as specified and directed. |
| 123 | M&L for 40 mm thick PCC 1:2:4, type B-1 ( 20 mm graded aggregate) in flooring cmplete all as specified and directed. |
| 124 | S&F for non skid coloured Ceramic tiles 07-08 mm thick (square/ rectangular) area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 125 | M&L rolled mild steel for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe- 290 (Gde E- 165).complate all specified and directed |
| 126 | M&L for Preparation of new steel Surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of black japan paint over a coat of red oxide complete all specified and directed. |
| 127 | S&F for 35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panel only) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces, The size of rail and stile as per IS-1003 (Part-I) (Larger size to be provided) kiln seasoned and chemically pressure treated fitted to chowkats all as specified and directed |
| 128 | M&L for rendering 15 mm in CM (1:6) over concrete wall surfaces finished even and smooth without using extra cement. |
| 129 | M&L Preparing newly plastered surfaces of walls and applying two coats of white wash. |
| 130 | M&L for 75 mm thick PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as cement concrete in Sub-base floors, sub-bases floors and pavings etc complete all as specified. |
| 131 | M&L for 20 mm thick screed bed in CM 1:4 for laying floor tiles . |
| 132 | M & L for Non-skid ceramic tiles 7 to 8 mm thick coloured tiles( square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match. |
| 133 | S & F 10 litres PVC, Syphonic action type, Flushing cistern low level, white with inlet ball valve float chain and pull and brackets complete. |
| 134 | S&F brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between fllanges. |
| 135 | S&F 32 mm bore Low density poly ethylene pipes of pressure rating 6kgf/cm2 fixed complete to walls,ceiling or in floors etc. |
| 136 | S & F Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. conforming to e 410-W (GdeE- 250) qualityA complete as specified. |
| 137 | S&F Gun metal globe or gate valve with Iron wheel head, screwed both ends for 20 mm dia of pipe and fixed. |
| 138 | M&L for construction of 1.20 m dia x 3.00 m deep soakage well, excavation in hard/dense soil foundation PCC 1:3:6 ,wells of honey combed solid block masonry wall, including intercepting chamber, screen chamber, RCC cover slab, filling with brick bats etc complete all as specified in drawing and respective PS. |
| 139 | Material & Labour for Light Point/fan wiring with 1.5 sq mm (nominal area), PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including PVC casing capping of adequate size with all fittings and accessories including PVC boxes for housing the switches ( Make of box Prestoplast,Prestoteak), including PVC insulated and unsheathed (FRLSH)single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. |
| 140 | All as per item No. 139 here in before One 3 pin socket outlet, 6 Amps on the same board with other switches, with cables 1.5sq. mm size |
| 141 | All as per item No. 139 here in before but for one 3 pin socket outlet 6 Amps three pin controlled by one switch on independent board complete all as specified directed. |
| 142 | All as per item No. 139 here in before but for one 5 pin socket outlet 16 Amp and 6 Amp Multipurpose independent using 2.5 Sqmm copper conductor cable (multi-strand) PVC insulated and unsheathed cable and 2.5 sqmm copper (multistrand) PVC insulated and unsheathed earth wire with terminal box of size 175mm x 100mm x 3.15mm complete all as specified. |
| 143 | S&F Socket outlet 2 in 1, 3 pin, 6 amp flush type |
| 144 | S&F Socket outlet 2 in 1, 3 pin, 6 and 16 amp flush type |
| 145 | S&F Switch Socket combination 2 in 1, 3 pin, 6 amp flush type |
| 146 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 16 Amp, 240 Volts complete all as specified & directed. |
| 147 | Supply and fixing ceiling rose, surface bakelite, 65mm x 50mm , two to three terminals complete all as specified & directed. |
| 148 | Supply & fixing switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified & directed. |
| 149 | Supply and fixing LED light fitting 1 x 20 Watt 220 volt AC decorative box type with driver, holder including LED tubelight connecting up with three core flexible copper conductor cable of size from ceiling rose complete all as directed. |
| 150 | Supply and fixing LED light fitting 1 x 10 Watt bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as directed. |
| 151 | S&F LED bulkhead fitting 10 watt (Endura Ruby) with all accessories and including connecting up with twin core twisted with flexible copper conductor cable with suitable size of 230 volts , 50 Hz complete all as specified and directed. |
| 152 | S&F of new generation energy saving and environmental friendly long life LED building security light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 35 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including twisted 3 core copper cable of size 1.5 Sqmm dia for connecting phase, neutral and earth from ceiling rose to light length as required at site,GI bracket 32 mm dia pipe and 02 numbers clamps, all fixing arrangements such as fastners, bolts, nuts washers etc all as specified and directed. |
| 153 | Supply and fix sheet metal enclosures for double door DBs when MCBs to be used 230 volts 8 way 200 Amp rated busbar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board. |
| 154 | S&F MCB SPN having braking capacity 10KA, 'C' curve, 40 Amps, 240 V complete all as specified and directed. |
| 155 | S&F MCB SPN having braking capacity 10KA, 'C' curve, 32 Amps, 240 V complete all as specified and directed. |
| 156 | S&F MCB SP having breaking capacity 10KA,'C' curve, 6 to 32 Amps, 240 V complete all as specified and directed. |
| 157 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge. |
| 158 | S & F incl leakage testing galvanised steel water tubing medium grade 40 mm dia bore with all fittings such as bends, elbow, socket, reducer etc, laid under floor / trenches all as specified & directed. |
| 159 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric cables with stranded aluminium conductor, 1100 volts grade, of 10 Sqmm 2 core complete all as specified and directed. |
| 160 | M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning. |
| 161 | Supplying and laying un-reinforced precast concerete cable cover, class LV, type 1 flat size 250mm x150mm x 40mm for cable protection , laid flat ie length of cable cover shall be laid across the cable complete all as specified and directed. |
| 162 | Taking down point wiring carefully copper/ aluminum (light,fan, socket or power) complete (fittings such as switches ceiling rose, pendents, regulators, sockets etc) |
| 163 | Taking down main switches, DBs alongwith existing board and removing the same from the site and making good the disturb surfaces / Portion of the wall etc all specified and directed by EIC. |
| 164 | Taking down sub main wiring/cable of any type and size and discription incl removal from DBs etc and removal of the same from site and making good the disturb surfaces or portion of wall/ceiling etc complete all as specified and directed by EIC. |
| 165 | S&F exhaust fan steel body AC single phase, 230V of size 250mm sweep heavy duty with blades, and frame and louvers complete all as specified and directed. |
| 166 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. complete all as directed. |
| 167 | Supply and fix sheet metal enclosures for DBs when MCBs to be used 230 volts 4 way 200 Amp rated busbar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board. |
| 168 | Supply and fix in replacement exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 26 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender