Petroleum and Natural Gas Boards / Undertakings / PSU Closing in 18 days TDR #57131386

Tender For For Supply And Application Of Pu Concrete Flooring In Old Lpg Pump House And Dielectric Epoxy Flooring In Vsd, Switch Gear Room At Ips Mansar Ura

Issued by Boards / Undertakings / PSU · Jaipur, Rajasthan
Tender Value
Ref. Documents
Estimated cost
Bid Submission
11 Sep 2026
18 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for For Supply And Application Of Pu Concrete Flooring In Old Lpg Pump House And Dielectric Epoxy Flooring In Vsd, Switch Gear Room At Ips Mansar Ura

BOQ

Name of Work:- FOR SUPPLY AND APPLICATION OF PU CONCRETE FLOORING IN OLD LPG PUMP HOUSE AND DIELECTRIC EPOXY FLOORING IN VSD, SWITCH GEAR ROOM AT IPS MANSAR URA
Sl. No. Item Description
1PU CONCRETE FLOORING SUPPLY AND APPLICATION OF HIGH-PERFROMANCE PU CONCRETE FLOORING: Supply and application of high‑performance PU concrete flooring (Ucrete) of minimum 3 mm finished thickness over existing concrete surfaces, complete in all respects, including the following sequential operations:1. Surface PreparationMechanical surface preparation of existing concrete surface by mechanical scarification, groove cutting, and thorough cleaning to remove all dust, dirt, laitance, grease, oil and loose particles, ensuring a sound, clean, and contamination-free substrate. All exisitng cracks, holes, grooves and other surface defects shall be properly filled and repaired using compatible Ucrete repair material.2. Scratch CoatApplication of a scratch coat of PU Concrete of 1 mm thickness shall be carried out. This shall be followed by an aggregate broadcasting process to ensure proper bonding and surface strength. allow to dry as per manufacturer specification.3. Final Top CoatThe final coat of PU Concrete shall be applied to a thickness of 2 mm. allow to dry per manufacturer specification.The system shall be prepared by properly mixing base resin, hardener, colour paste, and aggregates as per manufacturer’s specifications to achieve a durable and high‑performance finished floor.Technical Properties :Compressive Strength: ≥ 40 MPa (ASTM D695)Shore D Hardness: ≥70 (ASTM D2240)Abrasion Resistance: ≤ 50 mg (Taber Abrasion Test, CS‑17 wheel, 1 kg load, 1000 cycles, ASTM D4060)Note: Vendor shall submit test certificates from NABL accredited laboratory or Institute recognised by Government of India.
2DI-ELECTRIC EPOXY FLOORING SUPPLY AND APPLICATION OF HIGH-PERFORMANCE DI-ELECTRIC EPOXY FLOORING:Supply and application of high‑performance dielectric epoxy flooring of minimum 3.0 mm finished thickness over existing concrete surfaces, complete in all respects, including the following sequential operations:1. Surface PreparationMechanical surface preparation of existing concrete by grinding / shot‑blasting as required to remove laitance, loose particles, oil, grease, dirt, and contaminants, to achieve a clean, dry, sound, and suitably profiled substrate, in accordance with manufacturer’s specification. Any defects, cracks, or grooves shall be filled and repaired using compatible Ucrete repair material.2. Primer CoatApplication of epoxy primer coat by thoroughly mixing base and hardener in the specified ratio as per manufacturer’s technical data sheet, to ensure proper adhesion with the concrete substrate. Allow it to dry as per manufacturer's specification.3. Screed CoatApplication of epoxy screed coat by mixing epoxy base, hardener, and graded aggregates as per manufacturer’s specifications, laid to achieve the required thickness and mechanical strength. Broadcasting of aggregates over the screed coat shall be carried out as per manufacturer’s specification. Allow it to dry as per manufacturer's specification.4. Sealer CoatApplication of epoxy sealer coat over the cured screed layer to seal surface porosity and prepare the surface for the final finish. Allow it to dry as per manufacturer's specification.5. Final Dielectric Top CoatApplication of high‑performance dielectric epoxy top coat by mixing base resin, hardener, colour paste, and aggregates strictly as per manufacturer’s specifications, to obtain a uniform, durable, electrically insulating finish. Allow it to dry as per manufacturer's specification.Note: The dielectric epoxy top coat material shall be tested and certified by ERDA / NABL and shall have AC electric strength of more than 6.6 kV at the Top coat. A valid test certificate shall be submitted, clearly indicating the Flooring / coating material is suitable for more than 6.6 kV AC.
3EPOXY-BASED CONCRETE REPAIR MATERAIL SUPPLY AND APPLICATION OF EPOXY-BASED CONCRETE REPAIR MATERIAL : Epoxy‑based concrete repair material shall be supplied and applied for the repair of existing defects, cracks, and grooves on the concrete surface over which flooring is to be installed. The repair material shall be a three‑component system consisting of epoxy resin, hardener, and specially formulated fillers. All identified defects shall be properly prepared, filled, and rectified using this epoxy‑based concrete repair material in accordance with the manufacturer’s recommendations. Allow it to dry as per manufacturer's specification.Technical Properties :COMPRESSIVESTRENGTH ≥ 50 MPA (ASTM D 695)Shore D Hardness ≥ 55 (ASTM D2240)Unit of Measurement: kg (considering that a crack of 2‑inch width, 2 mm depth, and 20 m length shall consume approximately 6 kg of epoxy‑based concrete repair material).Note: Vendor shall submit test certificates from NABL accredited laboratory or Institute recognised by Government of India.
4CLOD ROAD MARKING COATING SUPPLY and APPLICATION OF COLD ROAD MARKING COATING: A 4 inch width yellow marking on Top coat of Dielectric Epoxy / PU concrete as per SCC, scope of work and instruction of EIC. Unit of measurement: Running meter of 4\\" wide marking strip (Each running meter of 4\\" marking is equivalent to 0.1 Sq.M of area) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57131386
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 11-09-2026
Authority
Authority Name Gas Authority Of India Limited
Work Description Tender for For Supply And Application Of Pu Concrete Flooring In Old Lpg Pump House And Dielectric Epoxy Flooring In Vsd, Switch Gear Room At Ips Mansar Ura
Basic Detail
Tender No GAIL/CnP/JPR26SA039/2026-27
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 21 Aug 2026
Submission Date 11 Sep 2026
Open Date 12 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
04850f77-284a-49d8-8133-40b5ec60078c.html
BOQ_336407.xls
TENDER.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Sep 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

04850f77-284a-49d8-8133-40b5ec60078c.html

xls

BOQ_336407.xls

pdf

TENDER.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders