Defence Statutory Bodies & Commissions/Committees Closing in 12 days TDR #57131046

Tender For Repair/Maint Of Internal Wiring And Replacement Of Unserviceable Mcb/Db, Submain And Junction Boxes Of Md Accn At Wokha Grn Of 24 Assam Rifles.

Issued by Statutory Bodies & Commissions/Committees · Phek, Nagaland
Tender Value
2.73 Lakhs
Estimated cost
Bid Submission
10 Sep 2026
12 days left
EMD
5500
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Phek → Nagaland
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Internal Wiring And Replacement Of Unserviceable Mcb/Db, Submain And Junction Boxes Of Md Accn At Wokha Grn Of 24 Assam Rifles.

BOQ

Name of Work:- Repair/maint of internal wiring and replacement of unserviceable MCB/DB, submain and junction boxes of Md Accn at Wokha Grn of 24 Assam Rifles.
Sl. No. Item Description
1SCHEDULE -'A' PART-I (REPAIR/MAINT OF INTERNAL WIRING AND REPALCEMENT OF UNSERVICEABLE MCB/DB, SUBMAIN JUNCTION BOXES)
2Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.Group A.
3Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire.
4Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch.
5Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 A socket outlet.
6Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
7Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 A socket outlet.
8Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.15/16 A switch.
9Supplying and fixing brass batten/ angle holder including connection etc. as required.
10Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
11Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).8 way , Double door
12Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole.
13Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole.
14Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A.
15Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
16Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire.
17S & F LED tubelight fittings 18/20 Watt with prewired all as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57131046
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 2.73 Lakhs
LAST DATE 10-09-2026
Authority
Authority Name Assam Rifles
Work Description Tender for Repair/Maint Of Internal Wiring And Replacement Of Unserviceable Mcb/Db, Submain And Junction Boxes Of Md Accn At Wokha Grn Of 24 Assam Rifles.
Basic Detail
Tender No VIII.28028/24 AR/Engr/MW/2026-27/31
Bidding Type Tender
Location
City Phek
State Nagaland
Key Dates
Publish Date 21 Aug 2026
Submission Date 10 Sep 2026
Open Date 11 Sep 2026
Finance
Tender Value 2.73 Lakhs
Tender Fee 1000
EMD 5500
Exemption Not Available
Document List
BOQ_970139.xls
ee7a9b39-9c67-4a76-b55e-ef35435b284b.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Sep 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_970139.xls

html

ee7a9b39-9c67-4a76-b55e-ef35435b284b.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders