Agriculture Boards / Undertakings / PSU Closing in 8 days TDR #57131038

Tender For Special Repair Work Of Electrical Installations At Flat 321, Fci Guest House, Khelgaon, New Delhi

Issued by Boards / Undertakings / PSU · Delhi, Delhi
Tender Value
6.51 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
8 days left
EMD
13040
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repair Work Of Electrical Installations At Flat 321, Fci Guest House, Khelgaon, New Delhi

BOQ

Name of Work:- Special repair work of Electrical installations at Flat 321, FCI Guest House, Khelgaon, New Delhi
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
2Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
3Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular DP MCB, \\"C\\" curve including connections, painting etc. as required.
4Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
56 Module (200 mm X 75 mm)
6Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
75/6 A switch
815/16 A switch
93 pin 5/6 A socket outlet
106 pin 15/16 A socket outlet
11Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
12Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
13Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
142 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
152 X 4 sq. mm + 1 X 4 sq. mm earth wire
16Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
1720 mm
18Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
19Supplying and fixing 8 way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, nterconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
208 way
21Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
228 way (4 + 24), Double door
23Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
24Single Pole (6 A-32 A)
25Double Pole (32 A)
26Triple pole and neutral
27Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
28Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
2924-26 Watt
30Supplying, Installation, Testing & Commissioning of LED surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning C42 Hours with 70% of initial Lumen maintained till life ends, CCT /4000°K / 5700°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim.
3112 -15 watt
32Supply, Installation, Testing and Commissioning (SITC) of LED Decorative Wall Light decorative wall mounted light fitting, suitable for 220–240 V AC, 50 Hz supply, complete with LED driver, having metal, polycarbonate, or premium fabric-based body/shade with opal glass or fabric diffuser, having CRI ≥80 and Power Factor ≥0.90 along with Led bulb E27. The fitting shall be securely fixed on the interior wall with all necessary mounting accessories, screws, raw plugs and hardware, including connection to the existing lighting point, testing and commissioning, complete as required and as directed by the Engineer-in-Charge.
3310–12 W
34Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
351200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 M/Min (Minimum)
36Supply and installation of 9'' ( sweep size, 200 mm) ventilation/exhaust Fan, 1400 RPM motor with all accessories suitable for single phase, AC 230 volts, 50 Hz supply.
37Supply, installation, testing and commissioning of Wall Mounted, T-Shape Canopy Hood Kitchen Chimney having a size of 600 mm / 900 mm width, fitted with high-efficiency Brushless Direct Current (BLDC) Motor of minimum 130W operating wattage, having a minimum suction capacity of 1250 m3/hr with low-noise operation (not exceeding 44 dB at low speed), equipped with Filterless Technology, Intelligent Dry/Thermal Auto-Clean system with detachable metal oil collector, and Smart Gesture/Touch Control with built-in LED lamps, including providing and fixing of 150 mm diameter flexible PVC/Aluminum exhaust ducting pipe with outer weather cowl/grill, heavy-duty wall-mounting brackets, anchor fasteners, necessary electrical connections to the nearest 16A plug socket, and making good all damages to the wall/surface to match the existing finish, complete in all respects as per the directions of the Engineer-in-Charge.
38Supply of 20 W, 2 Feet LED Tube Light Fitting, with extruded aluminium housing and front clamped opal polycarbonate diffuser, having minimum luminous efficacy of 100 lm/W, Power Factor ≥0.90, CRI ≥70, CCT around 6500 K (Cool Day Light), suitable for operation on 140–280 V AC, 50 Hz, complete with inbuilt electronic LED driver, mounting clips, end caps and all necessary accessories, conforming to relevant IS/IEC standards, complete as required.
3910 W mirror light
40Supply of 3*4 sq mm - Copper Armoured cable conductor, XLPE Insulated, cores laid up, PVC tape/Extruded Inner sheathed for Multicore Cables , Armour (galvanised steel strip), extruded PVC Type ST2 sheathed, 1100V grade as per IS 7098(Part 1) 1988 with upto date amendments for following sizes ( certified by NABL accredited lab as in case required by Engineer-in-charge). (Refer Clause 10 A for testing and quality of material)
41Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface/iron channel of platforms channel as required. Upto 35 sq. mm (clamped with 1.0 mm thick metal saddle clamps)
42Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
43Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
44Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted 275 DELHI SCHEDULE OF RATES (E&M)-2025 Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. 1 Run of cable
45Supply and installation of following capacity CO2 and ABC type fire extinguishers confirming to the latest IS standard including wall-mounting bracket, metallic anchor fasteners, photoluminescent location sign, inspection tag, and all accessories complete as per local fire authority guidelines.
462 kg CO2 Fire Extinguisher
474 kg ABC Fire Extinguisher
48Supplying and laying of following size HDPE pipe (PN 6, PE 63) ISI marked along with all accessories like socket, bend, couplers etc. as per latest standard IS Code, Part II complete with fitting and cutting, jointing etc. Direct in ground (125 cm below ground level) including excavation and refeling the trench but excluding sand cushioning and protective covering etc.complete as required. (63 mm dia)
49Dismantling of old switch sockets , conduits if required , MCB DBs, GI boxes , end boxes , Light fittings
50Credit for Old dismantled Electrical Iron scrap items ( Old light fitting, MCB DBs, GI boxes, GI Conduit, old wiring etc. ) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57131038
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 6.51 Lakhs
LAST DATE 31-08-2026
Authority
Authority Name Food Corporation Of India
Work Description Tender for Special Repair Work Of Electrical Installations At Flat 321, Fci Guest House, Khelgaon, New Delhi
Basic Detail
Tender No HQ/EM/03/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 21 Aug 2026
Submission Date 31 Aug 2026
Open Date 01 Sep 2026
Finance
Tender Value 6.51 Lakhs
Tender Fee Ref. Documents
EMD 13040
Exemption Not Available
Document List
0572b4c3-37b3-4c77-bec4-fb41c7aed603.html
BOQ_970137.xls
tenderdoc.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Sep 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

0572b4c3-37b3-4c77-bec4-fb41c7aed603.html

xls

BOQ_970137.xls

pdf

tenderdoc.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail