Tender For Annual Maintenance Of 02 Nos. Generator Set Of 30 Kva Installed At Mcs Petrol Pump, Sector- 51 And Industrial Area Phase- Ii Under Sub Division No. 3, M.C. Chandigarh.
Tender Value
2.40 Lakhs
Estimated cost
Bid Submission
28 Aug 2026
3 days left
EMD
4810
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Annual Maintenance Of 02 Nos. Generator Set Of 30 Kva Installed At Mcs Petrol Pump, Sector- 51 And Industrial Area Phase- Ii Under Sub Division No. 3, M.C. Chandigarh.
BOQ
| Sl. No. | Item Description |
| 1 | The Annual Maintenance rate of Routine servicing and Mtc. of Generator Set & control panelof 30 KVA DG Set. The DG Set shall have to be tested twice a month or whenever required by the qualified and experienced staff. The job includes the cost of petty material required to complete the job. The job includes the cost of testing, cleaning, checking of battery oil, filters battery leads, temperature gauge, oil filters, air filter, engine oil, fuel filter, greasing of minor parts and other minor repair for proper working of the Gen set (Overhauling of Engine, Rewinding of Alternator, Repair of Self Starter is not covered in this contact). The other major components will be charged extras required at site on actual work done basis. The job includes checking control penal and checking of all connections etc. If Gen Set is in breakdown for more than 12 Hours then plenty of Rs. 400/per day will be imposed. The job includes checking control panel and checking of all connections etc. The Annual Maintenance includes Routine Checking and replacing of Coolant, air filter, oil filter, Diesel filter and o rings, ring gasket, Engine oil of approved make (Each DG set 2 services in a year).Both the DG Set at Petrol Pump Sec-51 & IA- Ph-2 must be in working condition in AMC Period as per the entire satisfaction of Engineer-in-Charge. (01 Set = 02 Nos. of DG set) |
| 2 | AMC Price as per Quotation:- 1st Year (2 DG Set) |
| 3 | S/I/T/C of PVC Insulated sheathed) Copper Conductor Cable ISI marked size single core 10 mm2.Supply & Erection of ISI Marked PVC insulated single core 10 mm2 cable of Copper Conductor (Sheathed) make Finolex/ Lapp/ Polycab/ Havell's/ left bare in pipe of suitable size excluding cost and erection of pipe/pole etc. (i) Cable size single core 10 mm2 Copper Conductor Grade. The work shall be executed to the entire satisfaction of Engineer-in-charge. |
| 4 | S/I/T/C of Battery 12 volt 100 AH Make Exide Drive and Dismantle the Battery. The work should be executed as per the entire satisfaction of Engineer in Charge. Including Buy Back |
| 5 | S/I/T/C of Battery Charges 12V/10Amp Make Tunica and Dismantle the Battery. The work should be executed as per the entire satisfaction of Engineer in Charge. Including Buy Back |
| 6 | S/I/T/C of AVR (automatic Voltage regulator) for escort model 30 KVA DG Set, Stamford alternator. The work should be executed as per the entire satisfaction of Engineer in Charge. Including Buy Back |
| 7 | S/I/T/C of Engine Stop Solenoid make Escort and Dismantle the Engine Stop Solenoid. The work should be executed as per the entire satisfaction of Engineer in Charge. Including Buy Back |
| 8 | S/I/T/C of Battery Water for 30 KVA escorts DG Set and Dismantle the old damaged Water pump. The work should be executed as per the entire satisfaction of Engineer in Charge. Set Each (12 Can x 5 Ltrs.) |
| 9 | S/I/T/C Repair of Fuel Pump, injector nozzles calibration and filment on DG Set at site till road trail Mico/ Bosh. The work should be executed as per the entire satisfaction of Engineer in Charge. |
| 10 | S/I/T/C of Door Locks areal type lock. The work should be executed as per the entire satisfaction of Engineer in Charge. |
| 11 | S/I/T/C of fresh pump fan belt V-Belt for 30 KVA escorts DG Set and Dismantle the old damaged pump fan belt. The work should be executed as per the entire satisfaction of Engineer in Charge. Including Buy Back |
| 12 | S/I/T/C of fresh Water pump for 30 KVA escorts DG Set and Dismantle the old damaged Water pump. The work should be executed as per the entire satisfaction of Engineer in Charge. Including Buy Back |
| 13 | S/I/T/C of fresh Radiator fan for 30 KVA escorts DG Set and Dismantle the old damaged Radiator fan. The work should be executed as per the entire satisfaction of Engineer in Charge. Including Buy Back Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysAug 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender